6 resultados para Videokeratography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the repeatability within anterior corneal topography measurements and agreement between measurements with the Pentacam HR rotating Scheimpflug camera and with a previously validated Placido disk–based videokeratoscope (Medmont E300). ------ SETTING: Contact Lens and Visual Optics Laboratory, School of Optometry, Queensland University of Technology, Brisbane, Queensland, Australia. ----- METHODS: Normal eyes in 101 young adult subjects had corneal topography measured using the Scheimpflug camera (6 repeated measurements) and videokeratoscope (4 repeated measurements). The best-fitting axial power corneal spherocylinder was calculated and converted into power vectors. Corneal higher-order aberrations (HOAs) (up to the 8th Zernike order) were calculated using the corneal elevation data from each instrument. ----- RESULTS: Both instruments showed excellent repeatability for axial power spherocylinder measurements (repeatability coefficients <0.25 diopter; intraclass correlation coefficients >0.9) and good agreement for all power vectors. Agreement between the 2 instruments was closest when the mean of multiple measurements was used in analysis. For corneal HOAs, both instruments showed reasonable repeatability for most aberration terms and good correlation and agreement for many aberrations (eg, spherical aberration, coma, higher-order root mean square). For other aberrations (eg, trefoil and tetrafoil), the 2 instruments showed relatively poor agreement. ----- CONCLUSIONS: For normal corneas, the Scheimpflug system showed excellent repeatability and reasonable agreement with a previously validated videokeratoscope for the anterior corneal axial curvature best-fitting spherocylinder and several corneal HOAs. However, for certain aberrations with higher azimuthal frequencies, the Scheimpflug system had poor agreement with the videokeratoscope; thus, caution should be used when interpreting these corneal aberrations with the Scheimpflug system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. To evaluate the performance of the dynamic-area high-speed videokeratoscopy technique in the assessment of tear film surface quality with and without the presence of soft contact lenses on eye. Methods. Retrospective data from a tear film study using basic high-speed videokeratoscopy, captured at 25 frames per second, (Kopf et al., 2008, J Optom) were used. Eleven subjects had tear film analysis conducted in the morning, midday and evening on the first and seventh day of one week of no lens wear. Five of the eleven subjects then completed an extra week of hydrogel lens wear followed by a week of silicone hydrogel lens wear. Analysis was performed on a 6 second period of the inter-blink recording. The dynamic-area high-speed videokeratoscopy technique uses the maximum available area of Placido ring pattern reflected from the tear interface and eliminates regions of disturbance due to shadows from the eyelashes. A value of tear film surface quality was derived using image rocessing techniques, based on the quality of the reflected ring pattern orientation. Results. The group mean tear film surface quality and the standard deviations for each of the conditions (bare eye, hydrogel lens, and silicone hydrogel lens) showed a much lower coefficient of variation than previous methods (average reduction of about 92%). Bare eye measurements from the right and left eyes of eleven individuals showed high correlation values (Pearson’s correlation r = 0.73, p < 0.05). Repeated measures ANOVA across the 6 second period of measurement in the normal inter-blink period for the bare eye condition showed no statistically significant changes. However, across the 6 second inter-blink period with both contact lenses, statistically significant changes were observed (p < 0.001) for both types of contact lens material. Overall, wearing hydrogel and silicone hydrogel lenses caused the tear film surface quality to worsen compared with the bare eye condition (repeated measures ANOVA, p < 0.0001 for both hydrogel and silicone hydrogel). Conclusions. The results suggest that the dynamic-area method of high-speed videokeratoscopy was able to distinguish and quantify the subtle, but systematic worsening of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Elliptical Scanning Algorithm is an effective method to individually detect and label the projected rings. It consecutively defines an elliptical annulus of one pixel wide which grows pixel by pixel and sweeps the image, from centre to periphery, until it detects and labels each whole ring. In a way, it works like a snake-annealing algorithm. Active contour models (snakes) are energy-minimising curves that deform to fit image features. Elliptical Scanning Algorithm changes its geometry in order to label reflected rings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Antecedentes La ectasia corneal post-lasik (ECPL) es una complicación infrecuente, pero devastadora en la cirugía lasik (queratomileusis asistida con éxcimer láser) para el tratamiento de la miopía con o sin astigmatismo. Con base en la tomografía corneal por elevación por imágenes de Scheimpflug (Sistema Pentacam HR, Oculus Wetzlar, Alemania), se propone un novedoso índice acumulativo de riesgo para ser utilizado como prueba diagnóstica de tamizaje y así prevenir esta complicación. Metodología Se realizó un estudio observacional analítico, de corte transversal tipo pruebas diagnósticas, con el fin de evaluar las características operativas del índice NICE teniendo como estándar de referencia el módulo de Belin-Ambrosio (Pentacam HR) utilizando un modelo de regresión logística binaria, tablas de contingencia y estimando el área bajo la curva ROC. Resultados Se evaluaron 361 ojos de los cuales el 59,3% provenían de pacientes de sexo femenino, la edad media global fue de 30 años (RIC 11,0). El modelo logístico binario aplicado se construyó con base en cuatro variables independientes cuantitativas (K2, PAQUI, EP e I-S) y una cualitativa (SEXO), y se determinó su relación con la variable dependiente, NICE (puntaje final). Las variables predictoras fueron estadísticamente significativas clasificando adecuadamente el 92,9% de los ojos evaluados según presencia o ausencia de riesgo. El coeficiente de Nagelkerke fue de 74,4%. Conclusiones El índice acumulativo de riesgo NICE es una herramienta diagnóstica novedosa en la evaluación de candidatos a cirugía refractiva lasik para prevenir la ectasia secundaria.