944 resultados para Venous blood sample


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to compare the glycemic values obtained with a glucometer with those determined by a colorimetric enzymatic assay in venous blood as well as to evaluate the possibility of using capillary blood samples of dogs with diabetes mellitus. A group with 30 diabetic dogs was formed and from each dog three blood samples were obtained for glycemic evaluations by different methods and blood collection sites. The mean glycemic values showed no significant difference between the different sites of blood collection and methods (P=0.90). Venous, pinna and carpal pad blood glucose showed excellent correlation with the colorimetric enzymatic assay (r=0.98; r=0.95 and r=0.96 respectively) and the obtained values fit properly the clinically acceptable intervals in the error grid analysis. The present study revealed that carpal pad, venous and pinna glucose measurements are clinically acceptable and this method is feasible for use in hospitalized diabetic dogs. The sample attainment of carpal pad proved to be effective and a viable alternative. Further work is necessary to assess the utility of this technique in a home environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer (PCA) and reference analyzer (RA).Animals-Clinically normal animals (24 cattle, 22 horses, and 22 sheep).Procedures-pH; Pco(2); Po(2); total carbon dioxide concentration; oxygen saturation; base excess; concentrations of HCO(3)(-), Na(+), K(+), and ionized calcium; Hct; and hemoglobin concentration were determined with a PCA. Results were compared with those obtained for the same blood sample with an RA. Bias (mean difference) and variability (95% confidence interval) were determined for all data reported. Data were also subjected to analyses by Deming regression and Pearson correlation.Results-Analysis of Bland-Altman plots revealed good agreement between results obtained with the PCA and those obtained with the RA for pH and total carbon dioxide concentration in cattle, K(+) concentration in horses and sheep, and base excess in horses. Except for Na(+) concentration and Hct in horses and sheep, correlation was good or excellent for most variables reported.Conclusions and Clinical Relevance-Data from blood gas and electrolyte analyses obtained by use of the PCA can be used to evaluate the health status of cattle, horses, and sheep. Furthermore, the handheld PCA device may have a great advantage over the RA device as a result of the ability to analyze blood samples on farms that may be located far from urban centers. (Am J Vet Res 2010;71:515-521)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anemia screening before blood donation requires an accurate, quick, practical, and easy method with minimal discomfort for the donors. The aim of this study was to compare the accuracy of two quantitative methods of anemia screening: the HemoCue 201(+) (Aktiebolaget Leo Diagnostics) hemoglobin (Hb) and microhematocrit (micro-Hct) tests. Two blood samples of a single fingerstick were obtained from 969 unselected potential female donors to determine the Hb by HemoCue 201(+) and micro-Hct using HemataSTAT II (Separation Technology, Inc.), in alternating order. From each participant, a venous blood sample was drawn and run in an automatic hematology analyzer (ABX Pentra 60, ABX Diagnostics). Considering results of ABX Pentra 60 as true values, the sensitivity and specificity of HemoCue 201(+) and micro-Hct as screening methods were compared, using a venous Hb level of 12.0 g per dL as cutoff for anemia. The sensitivities of the HemoCue 201(+) and HemataSTAT II in detecting anemia were 56 percent (95% confidence interval [CI], 46.1%-65.5%) and 39.5 percent (95% CI, 30.2%-49.3%), respectively (p < 0.001). Analyzing only candidates with a venous Hb level lower than 11.0 g per dL, the deferral rate was 100 percent by HemoCue 201(+) and 77 percent by HemataSTAT II. The specificities of the methods were 93.5 and 93.2 percent, respectively. The HemoCue 201(+) showed greater discriminating power for detecting anemia in prospective blood donors than the micro-Hct method. Both presented equivalent deferral error rates of nonanemic potential donors. Compared to the micro-Hct, HemoCue 201(+) reduces the risk of anemic female donors giving blood, specially for those with lower Hb levels, without increasing the deferral of nonanemic potential donors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a case of human T-lymphotropic virus type I associated myelopathy in a 50-year old woman in Nigeria. The patient presented with progressive loss of tone to the two lower limbs and later inability to walk. The HTLV-I antibody presence in the plasma collected from the patient was repeatedly detected by enzyme immunoassays (Abbott HTLV-I EIA and Coulter SELECT-HTLV I/II) and confirmed by Western blot technique. In addition, HTLV-I DNA was amplified from the genomic DNA isolated from the peripheral blood mononuclear cells of the patient by the polymerase chain reaction technique. This finding is significant being the first report of association of HTLV-I with myelopathy in Nigeria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Arterial base excess and lactate levels are key parameters in the assessment of critically ill patients. The use of venous blood gas analysis may be of clinical interest when no arterial blood is available initially. METHODS: Twenty-four pigs underwent progressive normovolaemic haemodilution and subsequent progressive haemorrhage until the death of the animal. Base excess and lactate levels were determined from arterial and central venous blood after each step. In addition, base excess was calculated by the Van Slyke equation modified by Zander (BE(z)). Continuous variables were summarized as mean +/- SD and represent all measurements (n = 195). RESULTS: Base excess according to National Committee for Clinical Laboratory Standards for arterial blood was 2.27 +/- 4.12 versus 2.48 +/- 4.33 mmol(-l) for central venous blood (P = 0.099) with a strong correlation (r(2) = 0.960, P < 0.001). Standard deviation of the differences between these parameters (SD-DIFBE) did not increase (P = 0.355) during haemorrhage as compared with haemodilution. Arterial lactate was 2.66 +/- 3.23 versus 2.71 +/- 2.80 mmol(-l) in central venous blood (P = 0.330) with a strong correlation (r(2) = 0.983, P < 0.001). SD-DIFLAC increased (P < 0.001) during haemorrhage. BE(z) for central venous blood was 2.22 +/- 4.62 mmol(-l) (P = 0.006 versus arterial base excess according to National Committee for Clinical Laboratory Standards) with strong correlation (r(2) = 0.942, P < 0.001). SD-DIFBE(z)/base excess increased (P < 0.024) during haemorrhage. CONCLUSION: Central venous blood gas analysis is a good predictor for base excess and lactate in arterial blood in steady-state conditions. However, the variation between arterial and central venous lactate increases during haemorrhage. The modification of the Van Slyke equation by Zander did not improve the agreement between central venous and arterial base excess.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Ischemia-reperfusion injury is believed to be a major cause of transferred skin flap failure. Cigarette smoking is known to be associated with endogenous antioxidant depletion, hypercoagulability, and cutaneous vasoconstriction. This investigation was carried out to study possible effects of pentoxyfilline or heparin on rat skin reperfusion injury under tobacco exposure. Materials and Methods. Thirty-six rats were randomized into two major groups: 18 were exposed to cigarette smoke during a 4 wk period prior to surgery; the remaining 18 underwent a sham smoking procedure. Each group was further divided into three equal subgroups: heparin, pentoxyfilline, and saline solution. One identical skin flap was raised in each animal. The vasculature of the flap was clamped for 3 h and reperfused for 5 min. A venous blood sample was obtained from the flap after reperfusion for serum malondialdehyde (MDA) and myeloperoxidase (MPO) analysis. Flap survival was assessed 7 d after the procedure. Results. The lipid peroxidation levels and flap necrosis were significantly higher in the cigarette-smoking group skin flaps. There was also a decrease of MPO activity in this group compared with the nonsmoking group. Heparin-treated rats had significantly lower MDA levels and showed the most viable percent area among smoking rats. Conclusions. These data suggest that heparin had a significant beneficial effect both on flap survival and on the lipid peroxidation reduction after smoke exposure in the rat axial-pattern skin flap subjected to ischemia and reperfusion injury. Pharmacologic therapy may represent an alternative way to counteract tobacco effects in flap surgery in emergency situations. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neonatal mortality is greater in commercial porcine genotypes, compared with the ancient Meishan breed that rapidly lay down adipose tissue; this may be related to hormones, such as triiodothyronine (T3) or leptin. Leptin is present in maternal milk; however, the extent to which this supply provides the neonate with leptin is unknown, but may play a role in growth and development. We investigated whether thyroid hormones and leptin concentrations in maternal milk differed between genotypes; and whether this influenced piglet concentrations or expression of genes involved in adipose tissue regulation. Eight Meishan and six commercial sows were entered into the study and milk samples from the day of parturition to day 4 postpartum was taken daily. The median birth weight piglet in each litter had a daily venous blood sample taken and was euthanised on day 4. Gene expressions of IGF-I, IGF-binding protein 3 (IGFBP-3), peroxisome proliferators activated receptor (PPAR) and glucocorticoid receptor (GR) were measured in adipose tissue using real-time PCR. T3 was increased in Meishan milk, but not in piglet plasma. Milk thyroxine was similar between breeds but commercial piglet levels were significantly higher. Leptin was higher in commercial sow milk throughout the study. Milk leptin was strongly correlated to plasma leptin during the first postnatal days and also to organ and body weight in Meishan piglets that also had significantly higher expression of GR, but not IGF-I, IGFBP-3 or PPAR. In conclusion, we have found a significant disparity in the provision of thyroid hormones in Meishan and commercial sow’s milk. These changes are not always translated to plasma concentrations of hormone in the piglet. Leptin appears to have a stronger role in growth and development in the Meishan genotype compared with commercial; along with the increased GR expression, this may also represent a potential mechanism behind the rapid accumulation of adipose tissue in Meishan piglets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Assessing CYP2E1 phenotype in vivo may be important to predict individual susceptibility to those chemicals, including benzene, which are metabolically activated by this isoenzyme. Chlorzoxazone (CHZ), a specific CYP2E1 substrate, is readily hydroxylated to 6-OH-chlorzoxazone (6-OH-CHZ) by liver CYP2E1 and the metabolic ratio 6-OH-CHZ/CHZ in serum (MR) is a specific and sensitive biomarker of CYP2E1 activity in vivo in humans. We used this MR as a potential biomarker of effect in benzene-treated rats and, also, in humans occupationally exposed to low levels of benzene. Male Sprague-Dawley rats (375-400 g b.w.) were treated i.p. for 3 days with either a 0.5 ml solution of benzene (5 mmol/kg b.w.) in corn oil, or 0.5 ml corn oil alone. Twenty-four hours after the last injection, a polyethylene glycol (PEG) solution of CHZ (20 mg/kg b.w.) was injected i.p. in both treated and control animals. After 2, 5.10,15, 20,30,45, 60, 90, 120, 180, and 240 min from injection, 0.2 ml blood was taken from the tip tail and stored at -20 degrees C until analysis. A modified reverse phase HPLC method using a 5 mu m Ultrasphere C18 column equipped with a direct-connection ODS guard column, was used to measure CHZ and its metabolite 6-OH-CHZ in serum. No statistically significant difference in the MR was observed, at any sampling time, between benzene-treated and control rats. The concentration-versus-time area under the curve (AUC), however, was lower (p < 0.05, Mann-Whitney test), whereas the systemic clearance was higher (p < 0.05) in treated than in control rats. Eleven petrochemical workers occupationally exposed to low levels of airborne benzene (mean +/- SD, 25.0 +/- 24.4 mu g/m(3)) and 13 non-exposed controls from the same factory (mean +/- SD, 6.7 +/- 4.0 mu g/m(3)) signed an informed consent form and were administered 500 mg CHZ p.o. Two hours later a venous blood sample was taken for CHZ and 6-OH-CHZ measurements. Despite exposed subjects showed significantly higher levels of t,t-MA and S-PMA, two biomarkers of exposure to benzene, than non-exposed workers, no difference in the MR mean values +/- SD was found between exposed (0.59 +/- 0.29) and non-exposed (0.57 +/- 0.23) subjects. So, benzene was found to modify CHZ disposition, but not CYP2E1 phenotype in benzene-treated rats, nor in workers exposed to benzene, probably due to the levels of exposure being too low. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Susceptibility Weighted Image (SWI) is a Magnetic Resonance Imaging (MRI) technique that combines high spatial resolution and sensitivity to provide magnetic susceptibility differences between tissues. It is extremely sensitive to venous blood due to its iron content of deoxyhemoglobin. The aim of this study was to evaluate, through the SWI technique, the differences in cerebral venous vasculature according to the variation of blood pressure values. 20 subjects divided in two groups (10 hypertensive and 10 normotensive patients) underwent a MRI system with a Siemens® scanner model Avanto of 1.5T using a synergy head coil (4 channels). The obtained sequences were T1w, T2w-FLAIR, T2* and SWI. The value of Contrast-to-Noise Ratio (CNR) was assessed in MinIP (Minimum Intensity Projection) and Magnitude images, through drawing free hand ROIs in venous structures: Superior Sagittal Sinus (SSS) Internal Cerebral Vein (ICV) and Sinus Confluence (SC). The obtained values were presented in descriptive statistics-quartiles and extremes diagrams. The results were compared between groups. CNR shown higher values for normotensive group in MinIP (108.89 ± 6.907) to ICV; (238.73 ± 18.556) to SC and (239.384 ± 52.303) to SSS. These values are bigger than images from Hypertensive group about 46 a.u. in average. Comparing the results of Magnitude and MinIP images, there were obtained lower CNR values for the hypertensive group. There were differences in the CNR values between both groups, being these values more expressive in the large vessels-SSS and SC. The SWI is a potential technique to evaluate and characterize the blood pressure variation in the studied vessels adding a physiological perspective to MRI and giving a new approach to the radiological vascular studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the field of thrombosis and haemostasis, many preanalytical variables influence the results of coagulation assays and measures to limit potential results variations should be taken. To our knowledge, no paper describing the development and maintenance of a haemostasis biobank has been previously published. Our description of the biobank of the Swiss cohort of elderly patients with venous thromboembolism (SWITCO65+) is intended to facilitate the set-up of other biobanks in the field of thrombosis and haemostasis. SWITCO65+ is a multicentre cohort that prospectively enrolled consecutive patients aged ≥65 years with venous thromboembolism at nine Swiss hospitals from 09/2009 to 03/2012. Patients will be followed up until December 2013. The cohort includes a biobank with biological material from each participant taken at baseline and after 12 months of follow-up. Whole blood from all participants is assayed with a standard haematology panel, for which fresh samples are required. Two buffy coat vials, one PAXgene Blood RNA System tube and one EDTA-whole blood sample are also collected at baseline for RNA/DNA extraction. Blood samples are processed and vialed within 1 h of collection and transported in batches to a central laboratory where they are stored in ultra-low temperature archives. All analyses of the same type are performed in the same laboratory in batches. Using multiple core laboratories increased the speed of sample analyses and reduced storage time. After recruiting, processing and analyzing the blood of more than 1,000 patients, we determined that the adopted methods and technologies were fit-for-purpose and robust.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background To identify the most appropriate cut-off points of fasting glycemia for the screening of diabetes mellitus type 2 (DM2) with the comparison of the properties of capillary glycemia (CG) and venous blood plasma glycemia (PG) in a population of Japanese origin from the community of Mombuca, Guatapará - SP, Brazil. Methods This was a population-based descriptive cross-sectional study conducted on a sample of 131 individuals of both genders aged 20 years or more (66.8% of the target population). CG was measured with a glucometer in a blood sample obtained from the fingertip and PG was determined by an enzymatic method (hexokinase) in venous blood plasma, after a 10-14 hour fast in both cases. Data were analyzed by the receiver operating characteristic (ROC) curve in order to identify the best cut-off point for fasting glycemia (CG and PG) for the diagnosis of DM, using the 2-hour plasma glycemia > 200 mg/dl as gold - standard. Results The ROC curve revealed that the best cut-off point for the screening of DM was 110 mg/dl for CG and 105 mg/dl for PG, values that would optimize the relation between individuals with positive and false-positive results. The area under the ROC curve was 0.814 for CG (p < 0.01) and 0.836 for PG (p < 0.01). Conclusions The cut-off points of 105 mg/dl(5.8 mmol/l) for PG and of 110 mg/dl(6.1 mmol/l) for CG appear to be the most appropriate for the screening of DM2 in the population under study, with emphasis on the fact that the value recommended for CG is 5 mg/dl higher than that for PG, in contrast to WHO recommendations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the field of thrombosis and haemostasis, many preanalytical variables influence the results of coagulation assays and measures to limit potential results variations should be taken. To our knowledge, no paper describing the development and maintenance of a haemostasis biobank has been previously published. Our description of the biobank of the Swiss cohort of elderly patients with venous thromboembolism (SWITCO65+) is intended to facilitate the set-up of other biobanks in the field of thrombosis and haemostasis. SWITCO65+ is a multicentre cohort that prospectively enrolled consecutive patients aged ≥65 years with venous thromboembolism at nine Swiss hospitals from 09/2009 to 03/2012. Patients will be followed up until December 2013. The cohort includes a biobank with biological material from each participant taken at baseline and after 12 months of follow-up. Whole blood from all participants is assayed with a standard haematology panel, for which fresh samples are required. Two buffy coat vials, one PAXgene Blood RNA System tube and one EDTA-whole blood sample are also collected at baseline for RNA/DNA extraction. Blood samples are processed and vialed within 1 h of collection and transported in batches to a central laboratory where they are stored in ultra-low temperature archives. All analyses of the same type are performed in the same laboratory in batches. Using multiple core laboratories increased the speed of sample analyses and reduced storage time. After recruiting, processing and analyzing the blood of more than 1,000 patients, we determined that the adopted methods and technologies were fit-for-purpose and robust.