998 resultados para Variação dental


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cervical enamel projection (CEP) is an anatomic variation that can be found in the cement enamel junction, it´s recognition and early diagnosis improves outcome the tooth involved, allowing greater efficiency in treatment. The knowledge of the location, grade and incidence of CEP is decisive on prevention and treatment of periodontal disease. It were studied 1200 molars (600 mandibular molars and 600 maxillary molars) separated from the collection of teeth on the Discipline of Anatomy in FOSJCampos - UNESP. Each group of 600 teeth was separated from the second side (300 teeth) and the second type (first, second or third molar). Each tooth had thoroughly inspected the cervical region, in all their faces, in order to verify the incidence and the grade of CEP in each surface. It was found that the CEP covered in 278 (23,17%) teeth was 146 (52,52%) mandibular molars and 132 (47,48%) maxillary molars. The CEPs were concentrated on a tooth surface in 222 (79,86%) teeth, in two surfaces 53 (19,06%) teeth, and in three surfaces in three (1,08%) teeth. From the total of 4.800 surfaces examined the CEPs were found in 337 surfaces, and 228 (67,66%) surfaces of the grade I, 60 (17,8%) grade II and 49 (14,54%) grade III. The buccal surface presented 207 (61,42%) CEP, the lingual surface in 57 (16,91%), the mesial surface in 35 (10,39%) and the distal surface in 38 (11,28%) CEP. The results of this study demonstrated that the CEPs have focused more on the mandibular teeth on only one surface of the tooth, the grade I was the most found and the buccal surface the most involved

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Muscle activity has been studied indirectly through analyses of temperature variation in skin surface temperature on the masticatory muscles. These procedure may be an important tool for clinical evaluation and assessment of the evolution of temporomandibular disorders, as well as monitoring the adopted protocol. Thus, its utilization for identified pathological alterations on blood circulation and/or on metabolic activity in subcutaneous tissues, such as the masticatory muscles, is justified. The aim of this study was to investigate the effect of occlusal splints’ thickness on the variation of surface temperature of the anterior temporal and masseter muscles during rest and clenching. It were analyzed 20 symptomatic subjects (10 males and 10 females) selected through the Research Diagnostic Criteria (RDC) questionnaire. Temperature expressed in degrees Celsius (ºC) was measured on the surface of both muscles measured with the aid of a digital thermometer with an infrared radiation reading system. The surface temperature of the anterior temporal and masseter muscles presented significant reduction during teeth clenching in relation to the mandibular rest position. However, there were no significant differences between conditions with and without occlusal splint or between the different thicknesses of splints analyzed. Masticatory muscles showed a considerable similar behavior for both sides, and no significant distinctions were observed between male and female patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste estudo in vivo foi avaliar comparativamente três técnicas de clareamento de dentes polpados quanto ao grau de cor final alcançado, sensibilidade dental e satisfação pessoal de operadores e pacientes. Indivíduos jovens de mesma faixa etária e padrão de higiene bucal foram selecionados e divididos aleatoriamente entre os grupos (G1; n=7) caseiro, com regime de uso de 8 h/dia/4 semanas; (G2; n=7) consultório, com regime de clareamento de 4 sessões semanais de 2 aplicações de 15 min cada e; (G3; n=6) associado, com caseiro e consultório combinados. Para as técnicas caseira e de consultório foram utilizados peróxido de carbamida a 16% (WhitegoldHome/Dentsply) e peróxido de hidrogênio a 35% (Whitegold Office/Dentsply), respectivamente. Os registros de cor foram obtidos por um único operador antes e após o emprego da cada técnica utilizando escala de cores Vita Bleachedguide 3D-Master e máquina fotográfica digital profissional (EOS Rebel XT Canon), com ajustes de iluminação, flash e distância focal padronizados. O nível de clareamento foi avaliado por unidades de mudança de cor (luminosidade) na escala de cores, além do número de tons alcançados nas imagens digitais e mudança de cor no sistema CIE L*a*b* por meio do software ScanWhite. Os dados foram tratados estatisticamente pelos testes não paramétricos de Kruskal Wallis e dos sinais (p≤0,05). Os registros de sensibilidade dental trans e pós operatória e da satisfação pessoal dos operadores e pacientes foram preenchidos individualmente em questionário unidimensional ao final de cada sessão. Foram atribuídos escores para a avaliação final da sensibilidade dental, conforme: 0=ausente; 1=leve; 2=moderada e; 3=severa. Os dados foram tratados estatisticamente pelo teste Kruskal Wallis. As médias das variações de unidades de mudança de cor da escala Vita e do software foram, respectivamente: G1) 4,57 (IC1,34), 27,14 (IC12,03); G2) 2,86 (IC0,99), 21,29 (IC14,27); G3) 4 (IC1,82), 25,33 (IC10,70). Na comparação entre os métodos de avaliação de cor, os p-valores do teste dos sinais foram 0,453, 0,453 e 0,687 para os grupos 1, 2 e 3, respectivamente. As médias da variação total de cor (∆E) foram, respectivamente: G1) 8,79(IC4,18), G2) 7,10(IC3,53) e G3) 9,74 (IC4,07). Não foi determinada diferença estatisticamente significante entre os grupos. Os postos médios do nível de sensibilidade foram: G1 = 9,64; G2 = 11,58; e G3 = 10,43, e o p-valor = 0,807. Não houve diferença estatisticamente significante entre grupos. Conclui-se que as técnicas caseiro, consultório e associada foram igualmente eficazes quanto ao nível de cor final, de acordo com os métodos objetivos e subjetivos utilizados. O nível de sensibilidade dental foi o mesmo independentemente da técnica utilizada. Todos os indivíduos registraram satisfação ao final do clareamento.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Even nowadays there is in Brasil a large number of edentulous and a precarious financial condition of most of the population. In addition, World Health Organization aims for oral health, which consists on the maintenance of a natural dentition, functional and aesthetic composed of at least 20 teeth, without need of prosthetic intervention throughout life. From this and considering the lack of researches about the permanence of edentulous spaces in the oral cavity, and also avoiding overtreatment, this research has been proposed. Thus, the aim was to evaluate the effect of different lengths of the shortened lower dental arch in the presence or absence of a removable partial denture (RPD) on masticatory function, quality of life and occurrence of temporomandibular dysfunction. To achieve this goal, we compared the masticatory efficiency (colorimetric test), the oral comfort through the analysis of the impact of oral health in quality of life (OHIP-14), the presence of temporomandibular dysfunction (RDC/TMD) and the general quality of life (WHOQOL) of patients with shortened dental arches (SDA) (n=60), which is an arch with a reduction of teeth starting posteriorly, and patients with complete dental arch (Complete DA) (n = 34). The group of patients whit SDA was divided among PPR wears (PPD + SDA) (n = 17) and non-wears (n = 43). The population of this study consisted on patients who received or looked for treatment at the clinics of the Department of Dentistry of UFRN, from clinical analysis and records. The sample was chosen by convenience. For statistical analysis, it was a database in SPSS 17.0, followed by descriptive analysis with frequencies, absolute values, tests of central tendency and variability. The statistical tests used were chi-squared and analysis of variance as well as Tukey s post test, when applicable, all with a 95% confidence level. The results shown a prevalence of TMD of 47,1% among patients using PRP and 69,8% among those who didn t, but this result wasn t statistically significant. The mean of the results of masticatory efficiency, WHOQOL and OHIP didn t show association to the presence or absence of PPR and to the lower number of occlusal units of the patients (0, 1, 2 or more occlusal). The association only occurred among the different groups of SDA and the patients with complete dental arch. Taking into account the results, it could be observed that studied patients with low posterior support using lower PRP didn t have better masticatory efficiency, general quality of life, less impacts of their oral conditions in quality of life or not even less temporomandibular dysfunction or better masticatory efficiency when compared to those who didn t use the prosthesis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Avaliar se fontes de luz aumentam a eficácia do peróxido de hidrogênio na técnica de clareamento profissional. METODOLOGIA: Foram empregados 60 dentes incisivos bovinos, com dimensões coronárias e radiculares padronizadas a partir do limite amelo-cementário, sendo descartada a porção lingual. Os corpos-de-prova (cp) foram limpos em ultra-som por 20 min e a dentina condicionada com H3PO4 a 38% por 15 s, sendo os (cp) imersos em solução de café solúvel a 25% por duas semanas. A dentina foi impermeabilizada com esmalte e os (cp) divididos em 5 grupos, sendo a cor inicial mensurada através do espectofotômetro-EasyShade (VITA). Todos os (cp) receberam três aplicações por 10 min do gel clareador Opalescence Xtra-Boost (Ultradent) conforme segue: Grupo 1 - controle, não recebeu fotoativação, Grupo 2 - ativado com luz halôgena, Grupo 3 - ativado com LED azul/LASER, Grupo 4 - ativado com LED verde/LASER e Grupo 5 - ativado com LED vermelho. Após o clareamento foi mensurada a variação de cor E, a*, b*e L* e as referentes à escala de cor Vita Clássico. Os dados foram submetidos à análise de variância, teste de Tukey e de Dunn (α=5%). RESULTADOS: A diferença geral da cor foi reduzida quando se empregou LED Azul e Luz Halógena, sendo que o desempenho do peróxido de hidrogênio a 38% foi intensificado dependendo da fonte de luz utilizada. A avaliação quantitativa de cor, obtida por espectrofotômetro e pela escala de cor Vita Clássico, foram coincidentes. CONCLUSÃO: O tipo de fonte de luz empregada interfere na eficácia do agente clareador.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of sodium bicarbonate jet (Profident System) on the gingival tissue was tested with comparison of application from 2 different angles: the angulation recommended by the manufacturer and ponted to the occlusal surface. The results showed a definite influence of the angulation on tissue trauma, with lesser degrees of injury when the modified angulation was applied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Ciência Odontólogica - FOA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)