973 resultados para Valve Replacement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Valvuloplasty of the aortic valve is currently used in selected patients for severe calcified aortic valve disease, but clinical effectiveness is low and complication rate remains high. In this study, the total particle load after valvuloplasty and the embolization risk of calcific debris into the coronary arteries was analyzed in an in vitro model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The perioperative risk for redo surgical aortic valve replacement (S-AVR) in patients with severe aortic stenosis and prior coronary artery bypass grafting (CABG) is increased. Transcatheter aortic valve implantation (TAVI) represents an alternative. We assessed the perioperative and mid-term clinical outcome of patients undergoing S-AVR or TAVI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper was to evaluate gender-related differences in patients undergoing mechanical aortic valve replacement with the CarboMedics valve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aortic stenosis has become the most frequent type of valvular heart disease in Europe and North America and presents in the large majority of patients as calcified aortic stenosis in adults of advanced age. Surgical aortic valve replacement has been recognized to be the definitive therapy which improves considerably survival for severe aortic stenosis since more than 40 years. In the most recent period, operative mortality of isolated aortic valve replacement for aortic stenosis varies between 1–3% in low-risk patients younger than 70 years and between 4 and 8% in selected older adults. Long-term survival following aortic valve replacement is close to that observed in a control population of similar age. Numerous observational studies have consistently demonstrated that corrective surgery in symptomatic patients is invariably followed by a subjective improvement in quality of life and a substantial increase in survival rates. More recently, transcatheter aortic valve implantation (TAVI) has been demonstrated to be feasible in patients with high surgical risk using either a retrograde transfemoral or transsubclavian approach or an antegrade, transapical access. Reported 30-day mortality ranges between 5 and 15%) and is acceptable when compared to the risk predicted by the logistic EuroSCORE (varying between 20 and 35%) and the STS Score, although the EuroScore has been shown to markedly overestimate the effective operative risk. One major concern remains the high rate of paravalvular regurgitation which is observed in up to 85% of the patients and which requires further follow-up and critical evaluation. In addition, long-term durability of these valves with a focus on the effects of crimping remains to be addressed, although 3-5 year results are promising. Sutureless biological valves were designed to simplify and significantly accelerate the surgical replacement of a diseased valve and allow complete excision of the calcified native valve. Until now, there are 3 different sutureless prostheses that have been approved. The 3f Enable valve from ATS-Medtronic received CE market approval in 2010, the Perceval S from Sorin during Q1 of 2011 and the intuity sutureless prosthesis from Edwards in 2012. All these devices aim to facilitate valve surgery and therefore have the potential to decrease the invasivness and to shorten the conventional procedure without compromise in term of excision of the diseased valve. This review summarizes the history and the current knowledge of sutureless valve technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aortic valve replacement using a tissue valve is controversial for patients younger than 60 years old. The long-term survival in this age group, the expected event rates during long-term follow-up, and valve-related complications are not clearly determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atrioventricular conduction abnormalities (AVCA) may complicate transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR). The aim of this study was to prospectively evaluate AVCA after TAVI and SAVR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To compare health-related quality of life (QoL) in patients undergoing transcatheter aortic valve implantation via transapical access (TA TAVI) with patients undergoing surgical aortic valve replacement (SAVR). METHODS One hundred and forty-four high-risk patients referred for aortic valve replacement underwent TAVI screening and were assigned to either TA TAVI (n = 51, age 79.7 ± 9.2 years, logistic EuroSCORE 26.5 ± 16.1%, 51% males) or SAVR (n = 93, age 81.1 ± 5.3 years, logistic EuroSCORE 12.1 ± 9.3%, 42% males) by the interdisciplinary heart team. QoL was assessed using the Short Form 36 (SF-36) Health Survey Questionnaire and the Hospital Anxiety and Depression Scale. Furthermore, current living conditions and the degree of independence at home were evaluated. RESULTS Patients undergoing TA TAVI were at higher risk as assessed by EuroSCORE (26.5 ± 16 vs. 12.1 ± 9, P < 0.001) and STS score (6.7 ± 4 vs. 4.4 ± 3, P < 0.001) compared with SAVR patients. At the 30-day follow-up, the rate of mortality was similar and amounted to 7.8% for TA TAVI and 7.5% for SAVR patients and raised to 25.5% in TA TAVI and 18.3% in SAVR patients after a follow-up period of 15 ± 10 months. Assessment of QoL revealed no differences in terms of anxiety and depression between TA TAVI and SAVR patients. The SF-36 mental health metascore was similar in both groups (65.6 ± 19 vs. 68.8 ± 22, P = 0.29), while a significant difference was observed in the physical health metascore (49.7 ± 21 vs. 62.0 ± 21, P = 0.015). After adjustment for baseline characteristics, this difference disappeared. However, every added point in the preoperative risk assessment with the STS score decreased the SF-36 physical health dimension by two raw points at the follow-up assessment. CONCLUSIONS Selected high-risk patients undergoing TAVI by using a transapical access achieve similar clinical outcomes and QoL compared with patients undergoing SAVR. Increased STS scores predict worse QoL outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to characterize aortic root dimensions of patients with aortic valve stenosis undergoing transcatheter aortic valve replacement (TAVR) and to evaluate sex differences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim of this study was to elucidate if postoperative neurocognitive function after biological aortic valve replacement (AVR) can be influenced by temperature management during cardiopulmonary bypass (CPB).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) offers a new treatment option for patients with aortic stenosis, but costs may play a decisive role in decision making. Current studies are evaluating TAVR in an intermediate-risk population. We assessed the in-hospital and 1-year follow-up costs of patients undergoing TAVR and surgical aortic valve replacement (SAVR) at intermediate operative risk and identified important cost components.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we show the use of three-dimensional printing models for preoperative planning of transcatheter valve replacement in a patient with an extreme porcelain aorta. A 70-year-old man with severe aortic stenosis and a porcelain aorta was referred to our center for transcatheter aortic valve replacement. Unfortunately, the patient died after the procedure because of a potential ischemic event. Therefore, we decided to fabricate three-dimensional models to evaluate the potential effects of these constructs for previous surgical planning and simulation of the transcatheter valve replacement.