1000 resultados para Validação de métodos
Resumo:
Plastic packaging materials intended for use in food packaging is an area of great interest from the scientific and economic point of view due to the irreversible internationalization and globalization process of food products. Nevertheless, a debate related to food safety aspects has emerged within the scientific community. Therefore, the development of analytical methods that allow identifying and quantifying chemical substances of toxicological potential in the packaging is considered essential. This article focuses on the main analytical methods, including validation parameters, as well as extraction and quantification techniques for determination of volatile organic compounds from food packaging materials.
Resumo:
OBJETIVO: Validar métodos de estimativas da gordura corporal (somatória de espessura de dobras cutâneas, circunferência da cintura (CC) e razão cintura-quadril (RCQ)) em portadores do HIV/Aids, tendo como padrão ouro a absortometria por dupla emissão de raios-X (Dexa) e a tomografia computadorizada de abdômen (TCA). MÉTODOS: Foram estudados 15 portadores do HIV/Aids tratados em uma unidade de saúde coligada a um hospital público universitário, São Paulo. Foram medidas a gordura subcutânea total (GST) mediante a somatória da espessura de sete dobras (bíceps, tríceps, subescapular, axilar média, supra-ilíaca, abdominal e panturrilha medial), a gordura subcutânea central (GSC) (somatória da espessura de quatro dobras) e a gordura subcutânea de membros (GSM) (somatória da espessura de três dobras). A GST, GSC e GSM foram comparadas com as medidas de gordura obtidas pela Dexa. A CC, a RCQ e a GSC foram comparadas com as medidas de gordura obtidas pela TCA. Na análise estatística, utilizou-se o coeficiente de correlação de Pearson (r) e foi utilizado o teste de Mann-Whitney. RESULTADOS: A gordura medida pela Dexa foi correlacionada com GST, a GSC e GSM, mesmo após o ajuste pela idade (r>0,80 para todos). A gordura total de abdômen medida pela TCA foi correlacionada com a CC, RCQ e a GSC após o ajuste pela idade (r>0,80 para todos). CONCLUSÕES: Os métodos de estimativa da gordura corporal devem ser escolhidos de acordo com o tipo de gordura a ser avaliada e podem ser utilizados em pesquisas e nos serviços de saúde como alternativa à Dexa e TCA para portadores do HIV/Aids.
Resumo:
The validation of an analytical method is fundamental to implementing a quality control system in any analytical laboratory. As the separation techniques, GC, HPLC and CE, are often the principal tools used in such determinations, procedure validation is a necessity. The objective of this review is to describe the main aspects of validation in chromatographic and electrophoretic analysis, showing, in a general way, the similarities and differences between the guidelines established by the different Brazilian and international regulatory agencies.
Resumo:
This work presents the VALIDATION SPREADSHEET, a public domain tool that can be used to evaluate the figures of merit for univariate analytical methods. A real example of BTEX determination in environmental samples is included to illustrate its use. The spreadsheet has been developed for Excel® and Open Office®, and is available on the internet at http//lqta.iqm.unicamp.br.
Resumo:
Complex B vitamins are present in some cereal foods and the ingestion of enriched products contributes to the recommended dietary intake of these micronutrients. To adapt the label of some products, it is necessary to develop and validate the analytical methods. These methods must be reliable and with enough sensitivity to analyze complex B vitamins naturally present in food at low concentration. The purpose of this work is to evaluate, with validated methods, the content of vitamins B1, B2, B6 and niacin in five cereal flours used in food industry (oat, rice, barley, corn and wheat).
Resumo:
Different agencies that supply validation guidelines worldwide establish almost the same parameters to be evaluated in the validation process of bioanalytical methods. However, they recommend different procedures, as well as establish different acceptance criteria. The present review delineates and discusses the stages involved in the validation procedures of bioanalytical methods designed for determining veterinary residues in food, explaining the main differences in the guidelines established for this purpose by the main regulatory agencies in the world.
Resumo:
Plastic packaging materials intended for use in food packaging is an area of great interest from the scientific and economic point of view due to the irreversible internationalization and globalization process of food products. Nevertheless, a debate related to food safety aspects has emerged within the scientific community. Therefore, the development of analytical methods that allow identifying and quantifying chemical substances of toxicological potential in the packaging is considered essential. This article focuses on the main analytical methods, including validation parameters, as well as extraction and quantification techniques for determination of volatile organic compounds from food packaging materials.
Resumo:
A UV spectrophotometric method was developed and validated and a chromatographic method was adapted from the American Pharmacopeia for the analysis of Fluoxetine Hydrochloride capsules. Ethanol was used as solvent for the spectrophotometric method, with detection and determination at 276 nm. The separation for the chromatographic method was carried out using the reversed-phase column LC-8, triethylamine buffer, stabilizer free tetrahydrofuran and methanol (5:3.5:1.5), pH 6.0 as mobile phase and detection at 227 nm. The results obtained for both methods showed to be accurate, precise, robust and linear over the concentration range 100.00 - 300.00 µg/mL and 40.00 - 80.00 µg/mL of fluoxetine hydrochloride for the spectrophotometric and chromatographic methods, respectively. The accuracy of the methods was evaluated by a recovery test and showed results between 98.89 and 101.10%.
Resumo:
Chromatographic methods are commonly used for analysis of small molecules in different biological matrices. An important step to be considered upon a bioanalytical method's development is the capacity to yield reliable and reproducible results. This review discusses validation procedures adopted by different governmental agencies, such as Food and Drug Administration (USA), European Union (EU) and Agência Nacional de Vigilância Sanitária (BR) for quantification of small molecules by bioanalytical chromatographic methods. The main parameters addressed in this review are: selectivity, linearity, precision, accuracy, quantification and detection limits, recovery, dilution integrity, stability and robustness. Also, the acceptance criterions are clearly specified.
Resumo:
The validation of analytical methods is an important step in quality control. The main objective of this study is to propose an HPLC experiment to verify the parameters of validation of chromatographic methods, based on green chemistry principles, which can be used in experimental courses of chemistry and related areas.
Resumo:
Three analytical methods for the determination of BTEX in water were optimized and validated. With the best method the analytes were extracted of 10 mL of sample with 2.50 g of NaCl in headspace vial of 20 mL by HS and SPME to 40 ºC for 30 min for adsorption and to 250 ºC for 4 min for desorption and were analyzed by GC-MS. The recovery was between 97.9% and 104.3%, and the limit of detection was 2.4 ng L-1 for o-xylene. This method was using to analyze BTEX in water supply and surface water in Ouro Preto city. No sample had concentrations of BTEX above the legislation.
Resumo:
The present work consists of the development and validation of analytical method for evaluation of glycyrrhizic acid, salicylic acid, and caffeine in chitosan-alginate nanoparticles by high performance liquid chromatography. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The methods were applied to nanoparticles suspensions containing the drugs and were able to determine the entrapment efficiency successfully. The best entrapment efficiency was achieved with the glycyrrhizic acid (95.4%).
Resumo:
A eficiência de métodos para análise de 5-hidroximetilfurfural por cromatografia líquida de alta eficiência com detecção na região do ultravioleta e determinação de sacarose, glicose e frutose por cromatografia líquida com detecção por índice de refração foi avaliada. Após otimização das condições analíticas, os principais parâmetros de validação (linearidade, limite de quantificação, limite de detecção, recuperação, sensibilidade e precisão) foram determinados e demonstraram que os procedimentos analíticos podem ser aplicados para o controle do processo de produção de poli(3-hidroxibutirato).
Resumo:
Considerando a composição da multimistura distribuída em Belo Horizonte/MG (trigo, fubá, casca de ovo e folha de mandioca), as metodologias de detecção e/ou quantificação dos fitatos e oxalatos foram validadas. A purificação em coluna de troca aniônica forte do ácido fítico e seus derivados desfosforilados extraídos da multimistura apresentou baixos valores de recuperação (49%) nas concentrações menores do fitato adicionado, em relação às mais elevadas (101%), sugerindo a interferência de minerais presentes em altas concentrações, principalmente cálcio. Dos métodos avaliados para a determinação do ácido oxálico, a cromatografia de exclusão iônica foi a que apresentou os melhores resultados, com boas recuperações nos níveis mais altos de adição (88%), apresentando, contudo, recuperação mais baixa nos níveis inferiores de adição (61%). Os teores de ácido fítico nas amostras variaram de 1,61 g/100 g a 2,25 g/100 g e, para o ácido oxálico, de 0,044 g/100 g a 0,057 g/100 g. Os critérios de validação dos métodos analíticos por cromatografia líquida de alta eficiência foram considerados satisfatórios quanto a seletividade e especificidade, linearidade, repetitividade e limites de detecção e quantificação. Contudo, o de recuperação não foi atendido satisfatoriamente, visto que as porcentagens obtidas foram inferiores ao esperado, levando-se em conta a concentração adicionada nas amostras.
Resumo:
A leflunomida é um pró-fármaco anti-reumático encontrado na forma de comprimidos revestidos com nome comercial ARAVA que, in vivo, é rápida e extensamente convertida a seu metabólito ativo A77 1726. Considerando a ausência de metodologia de controle de qualidade na literatura para a leflunomida, foram desenvolvidos métodos de caracterização e quantificação da leflunomida matéria-prima e na forma de comprimido, além de estudo preliminar de sua estabilidade. As técnicas de ponto de fusão, espectroscopia no IV, RMN 1H e 13C e CLAE associada a detector de arranjo de diiodos foram utilizadas para identificação e caracterização da leflunomida. O A77 1726 foi sintetizado e caracterizado pelas técnicas de espectroscopia no IV, RMN 1H e 13C, CLAE e DSC. Foi desenvolvido e validado método analítico para quantificação da leflunomida em comprimidos por CLAE utilizando coluna C18, ACN:água (50:50) como fase móvel e detecção em 254 nm. O método apresentou parâmetros cromatográficos adequados e parâmetros de desempenho analítico satisfatórios, com limite de detecção de 10 ng/mL. Método por espectroscopia derivada no UV foi desenvolvido e validado como alternativa para quantificação da leflunomida em comprimidos. A comparação do método por UV derivada com a CLAE, para determinação da leflunomida em comprimidos, mostrou que os métodos são intercambiáveis, creditando a técnica de UV para testes de controle de qualidade de rotina. Foram realizados estudos de degradação forçada dos comprimidos de leflunomida submetendo amostras à temperatura de 80 ºC ou exposição à radiação UV a 254 nm com lâmpada germicida. O principal produto de degradação encontrado foi o A77 1726. Além disso, outro produto de degradação, com tempo de retenção de 5,5 min (CLAE), apresentou quantidades significativas no estudo de degradação térmica.