959 resultados para Urine samples


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A kinetic spectrophotometric method with aid of chemometrics is proposed for the simultaneous determination of norfloxacin and rifampicin in mixtures. The proposed method was applied for the simultaneous determination of these two compounds in pharmaceutical formulation and human urine samples, and the results obtained are similar to those obtained by high performance liquid chromatography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultra-performance LC coupled to quadrupole TOF/MS (UPLC-QTOF/MS) in positive and negative ESI was developed and validated to analyze metabolite profiles for urine from healthy men during the day and at night. Data analysis using principal components analysis (PCA) revealed differences between metabolic phenotypes of urine in healthy men during the day and at night. Positive ions with mass-to-charge ratio (m/z) 310.24 (5.35 min), 286.24 (4.74 min) and 310.24 (5.63 min) were elevated in the urine from healthy men at night compared to that during the day. Negative ions elevated in day urine samples of healthy men included m/z 167.02 (0.66 min), 263.12 (2.55 min) and 191.03 (0.73 min), whilst ions m/z 212.01 (4.77 min) were at a lower concentration in urine of healthy men during the day compared to that at night. The ions m/z 212.01 (4.77 min), 191.03 (0.73 min) and 310.24 (5.35 min) preliminarily correspond to indoxyl sulfate, citric acid and N-acetylneuraminic acid, providing further support for an involvement of phenotypic difference in urine of healthy men in day and night samples, which may be associated with notably different activities of gut microbiota, velocity of tricarboxylic acid cycle and activity of sialic acid biosynthesis in healthy men as regulated by circadian rhythm of the mammalian bioclock.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bisphenol A (BPA) is used extensively in food-contact materials and has been detected routinely in populations worldwide, and this exposure has been linked to a range of negative health outcomes in humans. There is some evidence of an association between BPA and different socioeconomic variables which may be the result of different dietary patterns. The aim of this study was to conduct a preliminary investigation of the association between BPA and socioeconomic status in Australian children using pooled urine specimens and an area level socioeconomic index. Surplus pathology urine specimens collected from children aged 0-15 years in Queensland, Australia as samples of convenience (n = 469) were pooled by age, sex and area level socioeconomic index (n = 67 pools), and analysed for total BPA using online solid phase extraction LC-MS/MS. Concentration ranged from 1.08-27.4 ng/ml with geometric mean 2.57 ng/ml, and geometric mean exposure was estimated as 70.3 ng/kg d-1. Neither BPA concentration nor excretion was associated with age or sex, and the authors found no evidence of an association with socioeconomic status. These results suggest that BPA exposure is not associated with socioeconomic status in the Australian population due to relatively homogenous exposures in Australia, or that the socioeconomic gradient is relatively slight in Australia compared with other OECD countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Integrated exposure to polycyclic aromatic hydrocarbons (PAHs) can be assessed through monitoring of urinary mono-hydroxylated PAHs (OH-PAHs). The aim of this study was to provide the first assessment of exposure to PAHs in a large sample of the population in Queensland, Australia including exposure to infant (0-4. years). De-identified urine specimens, obtained from a pathology laboratory, were stratified by age and sex, and pooled (n. =. 24 pools of 100) and OH-PAHs were measured by gas chromatography-isotope dilution-tandem mass spectrometry. Geometric mean (GM) concentrations ranged from 30. ng/L (4-hydroxyphenanthrene) to 9221. ng/L (1-naphthol). GM of 1-hydroxypyrene, the most commonly used PAH exposure biomarker, was 142. ng/L. The concentrations of OH-PAHs found in this study are consistent with those in developed countries and lower than those in developing countries. We observed no association between sex and OH-PAH concentrations. However, we observed lower urinary concentrations of all OH-PAHs in samples from infants (0-4. years), children (5-14. years) and the elderly (>. 60. year old) compared with samples from other age groups (15-29, 30-44 and 45-59. years) which may be attributed to age-dependent behaviour-specific exposure sources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The illegal use of anabolic substances in the meat producing industry is an ongoing problem due to the continual production of new synthetic compounds and/or the practice of low-level cocktail administration to avoid detection by the surveillance schemes of EU member states National Plan surveillance systems.

We present a highly sensitive reporter gene assay and sample extraction procedure based on a two step solid phase extraction and high performance liquid chromatography, developed for the detection of glucocorticoid abuse in bovine urine. The assay is capable of detecting compounds with glucocorticoid bioactivity and is extremely sensitive with an EC50 of 0.79 ng mL-1 for dexamethasone. New or unknown compounds with glucocorticoid bioactivity and low-level cocktail mixtures are detectable by this assay.

Cross-reactivity data for a range of 11ß-hydroxyglucocorticoids has been provided. This assay shows low interference from the 11-keto prohormones and other steroidal hormones. The assay may be suitable for application in other matrices such as hair. In conclusion this screening assay offers advantages over existing analytical techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel stir bar sorptive extraction (SBSE) method coupled with high performance liquid chromatography (HPLC) and UV detection for the extraction of diclofenac (DIC) from paediatric urine samples has been developed and validated. Selectivity and sensitivity being the prime objectives of the bioanalytical method for clinical samples, an optimised SBSE protocol was developed that selectively extracted DIC from various concurrently administered drugs. The validated assay was found to be linear (r=0.9999) over a concentration range of 100-2000 ng mL(-1). SBSE showed consistent recoveries (similar to 70%) of DIC across the validated linearity range. Overall, the method exhibited excellent accuracy and precision across all QC concentrations, tested over three days. Calculated LOD and LOQ were found to be 12.03 ng mL(-1) and 36.37 ng mL(-1), respectively, however, for the experimental purposes, 100 ngmL(-1) was considered as the validated LOQ(accuracy and precision at this LQC was

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND. To use spectra acquired by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) from pre- and post-digital rectal examination (DRE) urine samples to search for discriminating peaks that can adequately distinguish between benign and malignant prostate conditions, and identify the peaks’ underlying biomolecules. METHODS. Twenty-five participants with prostate cancer (PCa) and 27 participants with a variety of benign prostatic conditions as confirmed by a 10-core tissue biopsy were included. Pre- and post-DRE urine samples were prepared for MALDI MS profiling using an automated clean-up procedure. Following mass spectra collection and processing, peak mass and intensity were extracted and subjected to statistical analysis to identify peaks capable of distinguishing between benign and cancer. Logistic regression was used to combine markers to create a sensitive and specific test. RESULTS. A peak at m/z 10,760 was identified as b-microseminoprotein (b-MSMB) and found to be statistically lower in urine from PCa participants using the peak’s average areas. By combining serum prostate-specific antigen (PSA) levels with MALDI MS-measured b-MSMB levels, optimum threshold values obtained from Receiver Operator characteristics curves gave an increased sensitivity of 96% at a specificity of 26%. CONCLUSIONS. These results demonstrate that with a simple sample clean-up followed by MALDI MS profiling, significant differences of MSMB abundance were found in post-DRE urine samples. In combination with PSA serum levels, obtained from a classic clinical assay led to high classification accuracy for PCa in the studied sample set. Our results need to be validated in a larger multicenter prospective randomized clinical trial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human papillomavirus is a DNA virus that includes 118 genotypes. HPV16 is responsible for 80% of cervical cancer in women. Men are important reservoirs and major transmitters of HPV to their partners. The aim of this study was to detect HPV DNA and to determine the prevalence of HPV types 6, 11, 16, and 18 in urine samples of men infected with HIV-1. This study included 223 patients infected with HIV-1 from the Center of Reference on HIV/AIDS (CRT-SP) and an outpatient clinic of HIV. Urine samples were collected and after DNA extraction real-time PCR was performed for detection of HPV DNA. Positive samples were then tested by conventional PCR using type-specific primers for the four HPV types. A total of 223 men infected with HIV-1 were tested, 81% of whom were on HAART. Four (5.8%) were positive for HPV6, 18 (26.1%) were positive for HPV11, 22 (31.9%) were positive for HPV16 and five (7.2%) were positive for HPV18 by conventional PCR. Twenty (29%) patients had other HPV types and five patients (1.5%) had multiple types. The mean T CD4+cells count was 517 and 441 cells/mm(3) (P=0.30), in HPV negative and positive men, respectively. The HIV viral load was higher in the HPV negative group than for in the men with HPV (P=0.0002). A 30.9% prevalence of HPV was found in asymptomatic urine samples of men infected with HIV-1. This study suggests that urine may be a useful specimen for HPV screening. J. Med. Virol 81:2007-2011, 2009. (C) 2009 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes an efficient, fast, and reliable analytical methodology for mercury determination in urine samples using stripping chronopotentiometry at gold film electrodes. The samples were sonicated in the presence of concentrated HCl and H2O2 for 15 min in order to disrupt the organic ligands and release the mercury. Thirty samples can be treated over the optimized region of the ultrasonic bath. This sample preparation was enough to allow the accurate stripping chronopotentiometric determination of mercury in the treated samples. No background currents and no passivation of the gold film electrode due to the sample matrix were verified. The samples were also analyzed by cold vapour atomic absorption spectrometry (CV-AAS) and good agreement between the results was verified. The analysis of NIST SRM 2670 (Toxic Metals in Freeze-Dried Urine) also validated the proposed electroanalytical method. Finally, this method was applied for mercury evaluation in urine of workers exposed to hospital waste incinerators. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ceftazidime shows two main polarographic reduction peaks at pH 4.0, that at -0.45 V owing to reduction of the C=N bond in the methylethoxyimino group and that at -1.00 V owing to the reductive elimination of pyridine: the first peak is particularly suitable for the determination of ceftazidime. Ceftazidime can also be determined indirectly using the tensammetric peak at -0.60 V (in Britton-Robinson buffer pH 9.5) of pyridine liberated on hydrolysis. Ceftazidime can be determined in urine using the direct method only after Cls solid phase extraction, but it can be determined directly in the urine by hydrolysing it and using the pyridine peak. (C) 1997 Elsevier B.V. B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective - To evaluate the reliability of urine carnitine concentrations measured in single postprandial samples, compared with carnitine concentrations measured in 24-hour urine samples. Animals - 19 healthy Beagles. Procedure - After emptying the urinary bladder by catheterization, dogs were fed a canned canine maintenance diet. Approximately 8 hours later, urine, plasma, and serum samples were obtained for determination of urinary carnitine fractional excretion and urine carnitine-to-creatinine concentration ratio. Results were compared with 24-hour urinary carnitine excretion rate. Results - Fractional excretion of carnitine and urine carnitine-to-creatinine ratios correlated poorly with 24-hour urinary carnitine excretion. Conclusion - Determination of 24-hour urinary carnitine excretion is recommended to measure urine carnitine concentrations in dogs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study is to develop a new enzymeless electroanalytical method for the indirect quantification of creatinine from urine sample. This method is based on the electrochemical monitoring of picrate anion reduction at a glassy carbon electrode in an alkaline medium before and after it has reacted with creatinine (Jaffe's reaction). By using the differential pulse voltammetry technique under the optimum experimental conditions (step potential, amplitude potential, reaction time, and temperature), a linear analytical curve was obtained for concentrations of creatinine ranging from 1 to 80 mu mol L-1, with a detection limit of 380 nmol L-1. This proposed method was used to measure creatinine in human urine without the interference of most common organic species normally present in biological fluids (e.g., uric acid, ascorbic acid, glucose, and phosphocreatinine). The results obtained using urine samples were highly similar to the results obtained using the reference spectrophotometric method (at a 95% confidence level). (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The specific gravity of urine (SG) indicates the number and weight of solute particles in urine; its measurement is helpful in interpreting proteinuria detected by dipstick tests and in monitoring adequate hydration in patients with nephrolithiasis. Four methods for measuring SG or osmolality of urine are currently available (depression of the freezing-point, urometry, refractometry, cation exchange on a reagent strip). Using a recently developed reagent strip, we have measured SG in morning urines of 340 non-selected outpatients and compared the results with SG measurements by refractometry of the same urines. In 86.2% of all urines, a good positive correlation between SG measured by reagent strip and refractometry was noted (r = 0.913, p = 0.0001). In 13.8% of the urines, however, the SG measured by reagent strip deviated by more than +/- 5 from the value obtained by refractometry; in 90% of these urines, glucosuria (reagent strip values too low or too high), proteinuria (values too high), or bacteriuria/leukocyturia (values too low or too high) could be found. In alkaline urine (pH > 7.0), SG values obtained by reagent strip have to be corrected by +5.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel approach is presented to determine mercury in urine samples, employing vortex-assisted ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction to prepare samples, and screen-printed electrodes modified with gold nanoparticles for voltammetric analysis. Mercury was extracted directly from non-digested urine samples in a water-immiscible ionic liquid, being back-extracted into an acidic aqueous solution. Subsequently, it was determined using gold nanoparticle-modified screen-printed electrodes. Under optimized microextraction conditions, standard addition calibration was applied to urine samples containing 5, 10 and 15 μg L−1 of mercury. Standard addition calibration curves using standards between 0 and 20 μg L−1 gave a high level of linearity with correlation coefficients ranging from 0.990 to 0.999 (N = 5). The limit of detection was empirical and statistically evaluated, obtaining values that ranged from 0.5 to 1.5 μg L−1, and from 1.1 to 1.3 μg L−1, respectively, which are significantly lower than the threshold level established by the World Health Organization for normal mercury content in urine (i.e., 10–20 μg L−1). A certified reference material (REC-8848/Level II) was analyzed to assess method accuracy finding 87% and 3 μg L−1 as the recovery (trueness) and standard deviation values, respectively. Finally, the method was used to analyze spiked urine samples, obtaining good agreement between spiked and found concentrations (recovery ranged from 97 to 100%).