952 resultados para Ultrasonography, Doppler, Color


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine the usefulness of computed tomography (CT), magnetic resonance imaging (MRI), and Doppler ultrasonography (US) in providing specific images of gouty tophi. METHODS: Four male patients with chronic gout with tophi affecting the knee joints (three cases) or the olecranon processes of the elbows (one case) were assessed. Crystallographic analyses of the synovial fluid or tissue aspirates of the areas of interest were made with polarising light microscopy, alizarin red staining, and x ray diffraction. CT was performed with a GE scanner, MR imaging was obtained with a 1.5 T Magneton (Siemens), and ultrasonography with colour Doppler was carried out by standard technique. RESULTS: Crystallographic analyses showed monosodium urate (MSU) crystals in the specimens of the four patients; hydroxyapatite and calcium pyrophosphate dihydrate (CPPD) crystals were not found. A diffuse soft tissue thickening was seen on plain radiographs but no calcifications or ossifications of the tophi. CT disclosed lesions containing round and oval opacities, with a mean density of about 160 Hounsfield units (HU). With MRI, lesions were of low to intermediate signal intensity on T(1) and T(2) weighting. After contrast injection in two cases, enhancement of the tophus was seen in one. Colour Doppler US showed the tophi to be hypoechogenic with peripheral increase of the blood flow in three cases. CONCLUSION: The MR and colour Doppler US images showed the tophi as masses surrounded by a hypervascular area, which cannot be considered as specific for gout. But on CT images, masses of about 160 HU density were clearly seen, which correspond to MSU crystal deposits.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La placenta ácreta es la implantación anómala de la placenta en la pared uterina. Se presenta en 0.9% de todos los embarazos; actualmente es una de las causas más importantes de morbimortalidad materna. Ecografía 2D y Doppler placentario son métodos diagnósticos de primera y segunda línea. Objetivo: Evaluar la utilidad diagnóstica de ecográfica 2D y Doppler color Placentario para diagnóstico de acretismo placentario en gestantes con factores de riesgo comparándolos con diagnóstico clínico e histopatológico; y determinar incidencia de acretismo placentario en población asistente a Clínica Universitaria Colombia. Metodología: Estudio de evaluación de tecnología diagnóstica. Entre Agosto a Noviembre de 2010 se incluyeron 53 gestantes entre 24 y 40 semanas de gestación con factores de riesgo para acretismo placentario. El desempeño diagnóstico de las pruebas se determinará por sensibilidad, especificidad, valores predictivos positivo y negativo. Las características demográficas de las pacientes y resultados neonatales se analizaron mediante proporción, media y rango. Resultados: Se determinó incidencia de acretismo placentario en 4,54% de las gestantes con presencia de factores de riesgo para esta patología. Los datos hasta el momento no nos permiten calcular valores de desempeño diagnóstico. Un caso termino en histerectomía por acretismo placentario. Conclusión: Con los datos preliminares registramos una incidencia de acretismo placentario de 1 en 22 pacientes. Revisión de literatura sustenta la necesidad de realización diagnostica prenatal que impacte en la morbimortalidad materna y fetal, haciendo necesario la evaluación diagnostica valida de herramientas como el Eco 2D y Doppler color en población a riesgo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La placenta ácreta es la implantación anómala de la placenta en la pared uterina. Se presenta en 0.9% de todos los embarazos; actualmente es una de las causas más importantes de morbimortalidad materna. Ecografía 2D y Doppler placentario son métodos diagnósticos de primera y segunda línea. Objetivo: Evaluar la utilidad diagnóstica de ecográfica 2D y Doppler color Placentario para diagnóstico de acretismo placentario en gestantes con factores de riesgo comparándolos con diagnóstico clínico e histopatológico; y determinar incidencia de acretismo placentario en población asistente a Clínica Universitaria Colombia. Metodología: Estudio de evaluación de tecnología diagnóstica. Entre Agosto a octubre 2011 se incluyeron 137 gestantes entre 24 y 40 semanas de gestación con factores de riesgo para acretismo placentario. El desempeño diagnóstico de las pruebas se determinará por sensibilidad, especificidad, valores predictivos positivo y negativo. Las características demográficas de las pacientes y resultados neonatales se analizaron mediante proporción, media y rango. Resultados: En un grupo de 137 pacientes con factores de riesgo de acretismo placentario analizadas se obtuvo el dato de 119 en cuanto a la finalización del embarazo. Se observaron 4 casos con diagnóstico clínico e histopatológico de acretismo placentario, evidenciando una prevalencia del 2,9%. La ecografía 2D y Doppler en la detección de acretismo placentario con un nivel de confianza del 95%, presentaron sensibilidad del 100% (IC95% 87,5-100) y especificidad de 100% (IC95% 99,6-100). Conclusión: Con los datos analizados registramos una incidencia de acretismo placentario de 4 en 132 pacientes. Revisión de literatura sustenta la necesidad de realización diagnostica prenatal que impacte en la morbimortalidad materna y fetal, haciendo necesario la evaluación diagnostica valida de herramientas como el Eco 2D y Doppler color en población a riesgo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim. Extrinsic compression of the popliteal artery and absence of surrounding anatomical abnormalities characterize the functional popliteal artery entrapment syndrome (PAES). The diagnosis is confirmed to individuals who have typical symptoms of popliteal entrapment and occlusion or important stenosis of the popliteal artery with color duplex sonography (CDS), magnetic resonance imaging (MRI) or arteriography during active plantar flexion-extension maneuvers. However, variable result findings in normal asymptomatic subjects have raised doubts as to the validity of these tests. The purpose of this study was to compare the frequency of popliteal artery compression in 2 groups of asymptomatic subjects, athletes and non-athletes.Methods. Forty-two individuals were studied. Twenty-one subjects were indoor soccer players, and 21 were sedentary individuals. Physical activity was evaluated through questionnaires, anthropometric measurements, and cardiopulmonary exercise test. Evaluation of popliteal artery compression was performed in lower limbs with CDS, ankle-brachial index (ABI) measurements and continuous wave Doppler of the posterior tibial artery.Results. The athletes studied fulfilled the criteria of high level of physical activity whereas sedentary subjects met the criteria of low level of activity. Popliteal artery compression was observed with CDS in 6 (14.2%) studied subjects; 2 of whom (4.7%) were athletes and 4 (9.5%) were non-athletes. This difference was not statistically significant (p=0.21). Doppler of the tibial arteries and ABI measurements gave good specificity and sensibility in the identification of popliteal artery compression.Conclusion. The frequency of popliteal artery compression during maneuvers in normal subjects was 14.2% irrespective of whether or not they performed regular physical activities. Both Doppler and ABI showed good agreement with CDS and should be considered in screening popliteal arteries in individuals suspected of PAES.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: (i) To investigate whether pulsatility index (PI) and mean flow velocities (MFV) are altered in glaucoma patients. (ii) To evaluate the significance of PI in retrobulbar autoregulation capacity. METHODS: Patients with primary open-angle glaucoma (POAG; n = 49), normal tension glaucoma (NTG; n = 62) and healthy controls (n = 48) underwent colour Doppler imaging measurements of the retrobulbar vasculature. Kruskal-Wallis test was used to compare variables between the three diagnostic groups. Restricted cubic splines were used to determine nonlinearities between the resistive index (RI) and PI correlations. RESULTS: Mean flow velocities (MFV) were lower in both short posterior ciliary arteries (SCPA) and central retinal arteries (CRA) from the two glaucoma groups (p < 0.04 versus healthy controls). No differences were detected in RI or PI in any arteries of the three diagnostic groups (p > 0.08). In healthy individuals, correlations between RI and PI were linear in all arteries. In both POAG and NTG patients, CRA presented a nonlinear curve with a cutpoint at RI 0.77 (p < 0.001) and 0.61 (p = 0.03), respectively, above which the slope increased nearly five- and tenfold (POAG: 1.96 to 10.06; NTG: -0.46-4.06), respectively. A nonlinear correlation in the ophthalmic artery was only observed in NTG patients, with a cutpoint at RI 0.82 (p < 0.001), above which the slope increased from 3.47 to 14.03. CONCLUSIONS: Glaucoma patients do not present the linear relationships between RI and PI observed in healthy individuals. Their nonlinear relations may be indicative of an altered autoregulation and suggest a possible threshold RI could be determined above which autoregulatory disturbances become more relevant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Recently, the absence of spontaneous venous pulsation (SVP) has been suggested as a vascular risk factor for primary open-angle glaucoma (POAG). As the mechanism behind this phenomenon is still unknown, the authors have studied this vascular component using colour Doppler imaging (CDI). METHODS: A total of 236 patients were divided into three diagnostic groups: healthy controls (81), POAG (86) and normal tension glaucoma (NTG; 69). All subjects were submitted to CDI studies of the retrobulbar circulation, intraocular pressure measurements and assessment of SVP existence. Mann-Whitney, chi-square contingency tables and Spearman correlations were used to explore differences and correlations between variables in the diagnostic groups. RESULTS: Eighty-two percent of healthy controls had SVP (66/81), while a smaller numbers were registered in both glaucoma groups: POAG - 50% (43/86); NTG - 51% (35/69). In NTG patients, but not in POAG patients, the prevalence of the SVP phenomenon decreases with increased glaucoma damage (p = 0.04; p = 0.55, respectively). Overall glaucoma patients from both groups had lower central retinal vein (CRV) velocities than the healthy controls (p < 0.05). NTG patients with SVP had less severe visual field defects (mean defect -6.92 versus -11.1, p < 0.05), higher [correction added after online publication 21 September 2012; the word 'higher' has been inserted to replace the word 'lower'] peak systolic and mean flow velocities in the central retinal artery (p < 0.01; p < 0.05, respectively) as well as higher [correction added after online publication 21 September 2012; the word higher has been inserted to replace the word lower] maximal velocities and RI of the CRV (p < 0.02; p < 0.05, respectively). CONCLUSIONS: Glaucoma patients have a decrease in CRV velocities. SVP is less prevalent in glaucoma patients than in healthy individuals. This phenomenon apparently reflects different hemodynamic patterns in the central retinal vessels. This variable may be of particular importance in NTG patients, where it may be associated with more advanced functional damage.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A precise knowledge of arterial, portal, hepatic and biliary anatomical variations is mandatory when a liver intervention is planned. However, only certain variations must be searched when a precise intervention is planned. The basic liver anatomy as well as the most relevant malformations will be precised.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O processo de recanalização das veias dos membros inferiores, após um episódio de trombose venosa profunda aguda em pacientes anticoagulados com heparina e inibidores da vitamina K, faz parte da evolução natural da remodelagem do trombo venoso. Esse complexo processo de remodelagem envolve a adesão do trombo à parede da veia, à resposta inflamatória da parede do vaso, levando à organização e subsequente contração do trombo, à neovascularização e à lise espontânea de áreas no interior do trombo. A presença de fluxo arterial espontâneo em veias com trombose recanalizada tem sido descrita como secundária à neovascularização e se caracteriza pelo desenvolvimento de fluxo com padrão de fístulas arteriovenosas, identificadas por meio de mapeamento dúplex colorido. Nesta revisão, são discutidos alguns aspectos controversos da história natural da trombose venosa profunda, para uma melhor compreensão da sua evolução e do seu impacto sobre a doença venosa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To establish reference values for the first trimester uterine artery resistance index (UtA-RI) and pulsatility index (UtA-PI) in healthy singleton pregnant women from Northeast Brazil. METHODS: A prospective observational cohort study including 409 consecutive singleton pregnancies undergoing routine early ultrasound screening at 11 - 14 weeks of gestation was performed. The patients responded to a questionnaire to assess maternal epidemiological characteristics. The left and right UtA-PI and UtA-RI were examined by color and pulsed Doppler by transabdominal technique and the mean UtA-PI, mean UtA-RI and the presence of bilateral protodiastolic notching were recorded. Quartile regression was used to estimate reference values. RESULTS: The mean±standard deviation UtA-RI and UtA-PI were 0.7±0.1 and 1.5±0.5, respectively. When segregated for gestation age, mean UtA-PI was 1.6±0.5 at 11 weeks, 1.5±0.6 at 12 weeks, 1.4±0.4 at 13 weeks and 1.3±0.4 at 14 weeks' gestation and mean UtA-RI was 0.7±0.1 at 11 weeks, 0.7±0.1 at 12 weeks, 0.6±0.1 at 13 weeks and 0.6±0.1 at 14 weeks' gestation. Uterine artery bilateral notch was present in 261 (63.8%) patients. We observed that the 5th and 95th percentiles of the UtA-PI and UtA-RI uterine arteries were 0.7 and 2.3 and, 0.5 and 0.8, respectively. CONCLUSION: Normal reference range of uterine artery Doppler in healthy singleton pregnancies from Northeast Brazil was established. The 95th percentile of UtA-PI and UtA-RI values may serve as a cut-off for future prediction of pregnancy complications studies (i.e., pre-eclampsia) in Northeast Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims to describe the uterine and ovarian ultrasonographic characteristics and Doppler velocimetric features of their arteries in bitches during the periovulatory period. Fifteen estrous cycles in 10 animals were evaluated. The ultrasonographic characteristics, resistance indices (RI) and pulsatility indices (PI) of the uterus and ovaries in each animal were recorded 5 days before and after ovulation (D0). The data were statistically analyzed, and the results were expressed as the mean ± standard error of mean (P<0.05). In results the ultrasonographic features of the uterus were the same on all of the cycles and evaluated days. The uterus had an average diameter of 0.85±0.02cm. An increase in the volume of the ovaries and the diameter of the ovarian follicles were measured. Ovaries had a volume of 0.64±0.06cm³, and the follicles cavities had a diameter of 0.46 ± 0.01 cm on the day of ovulation. After ovulation, it was observed that some follicles not collapse in some cycles. Two days prior to ovulation, the uterine blood perfusion decreased. This decrease remained unchanged until ovulation. Following ovulation, we measured a gradual increase in the uterine perfusion and in the ovarian artery. This artery directed blood flow to the ovaries and increased the intra-ovarian perfusion on the day after ovulation. In conclusion, specific features are observed in the uterus and ovarian ultrasound image and Doppler values of their arteries presented on the periovulatory days and when associated allow to estimate more accurately the date of ovulation.