928 resultados para Total coliforms
Resumo:
The present work evaluated the performance of two treatment systems in reducing indicators of biological contamination in swine production wastewater. System I consisted of two upflow anaerobic sludge blanket (UASB) reactors, with 510 and 209 L in volume, being serially arranged. System II consisted of a UASB reactor, anaerobic filter, trickling filter, and decanter, being also organized in series, with volumes of 300, 190, 250, and 150 L, respectively. Hydraulic retention times (HRT) applied in the first UASB reactors were 40, 30, 20, and 11 h in systems I and II. The average removal efficiencies of total and thermotolerant coliforms in system I were 92.92% to 99.50% and 94.29% to 99.56%, respectively, and increased in system II to 99.45% to 99.91% and 99.52% to 99.93%, respectively. Average removal rates of helminth eggs in system I were 96.44% to 99.11%, reaching 100% as in system II. In reactor sludge, the counts of total and thermotolerant coliforms ranged between 10(5) and 10(9) MPN (100 mL)(-1), while helminth eggs ranged from 0.86 to 9.27 eggs g(-1) TS.
Resumo:
SUMMARY The aim of this work was to compare, from a parasitological ( Cryptosporidiumspp. and Giardia duodenalis), bacteriological (total and thermotolerants coliforms) and physicochemical perspective, water sources used for drinking and irrigation of vegetables intended to be sold for human consumption. From January 2010 to May 2011, samples of different water sources from vegetable producing properties were collected; 100 liters for parasitological analysis, 200 mL for bacteriological analysis, and five liters for physicochemical analysis. Water samples were filtered under vacuum with a kit containing a cellulose acetate membrane filter, 1.2 µm (Millipore(r), Barueri, SP, Brazil). The material retained on the membrane was mechanically extracted and analyzed by direct immunofluorescence (Merifluor(r)kit). From 20 rural properties investigated, 10 had artesian wells (40 samples), 10 had common wells (40 samples), and one had a mine (four samples), the latter contaminated by Cryptosporidiumspp. In samples from artesian wells, 90 to 130 meters depth, 42.5% were positive for total coliforms and 5.0% were identified to have abnormal coloration. From the samples of common wells, 14 to 37 meters depth, 87.5% were contaminated with total coliforms, 82.5% were positive for thermotolerant coliforms, and 12.5% had color abnormalities. We did not detect the presence of Giardiaspp. or Cryptosporidiumspp. in artesian and common wells. The use of artesian or common wells is an important step in the control of the spreading of zoonoses, particularly Cryptosporidiumspp. and Giardiaspp., as well as artesian wells for coliform control in local production of vegetables to be marketed.
Resumo:
The performance of two upflow anaerobic sludge blanket (UASB) reactors was evaluated in pilot scale (908 and 188 L), installed in series (R1 and R2), fed with swine wastewater with TSS around 5 and 13 g L-1. The UASB reactors were submitted to HDT of 36 and 18 h with VOL of 5.5 to 34.4 g COD (L d)-1 in the R1 and HDT of 7.5 e 3.7 h with VOL from 5.1 to 45.2 g COD (L d)-1 in the R2. The average removal efficiencies of COD ranged from 55 to 85% in the R1 and from 43 to 57% in the R2, resulting in values from 82 to 93% in the UASB reactors in two stage. Methane concentrations in the biogas were 69 to 74% with specific production from 0.05 to 0.27 L CH4 (g removedCOD)-1 in the R1 and of 0.10 to 0.12 L CH4 (g removedCOD)-1 in the R2. The average removal efficiencies were 61 to 75% for totalP, 39 to 69% for KN, 82 to 93% for orgN and 20 to 94% for Fe, Zn, Cu and Mn. The amN concentration were not reduced indicating the need to post-treatment for effluent disposal into water bodies. There were reductions of total coliforms from 99.8123 to 99.9989% and of thermotolerant coliforms from 99.9725 to 99.9999%. The conditions imposed to the UASB reactors in two stage provided high conversions of removedCOD into methane (up to 77%) and reductions of organic an inorganic pollution loads from swine wastewater.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Water remains a predominant vector for human enteric pathogens not just for developing countries but also developed nations, where numerous infectious disease outbreaks, linked to the contamination of drinking water have been documented. Private drinking water wells are a source of drinking water that is largely unstudied even though a significant percentage of the population in Ontario relies on wells as their primary water source. As there exists little to no systematic surveillance for enteric infections or outbreaks related to well water sources, these individuals may be at higher risk of waterborne infectious diseases. The relationships between various fecal indicators in the water of private drinking water wells, including E. coli, Total Coliforms (TC) and Bacteroides, and enteric pathogens, including Campylobacter jejuni, Salmonella spp., and Shiga toxin producing E. coli, were studied. Convenience private well water samples collected from various regions of interest during the summer of 2014 underwent membrane filtration and culture to determine quantities of E. coli and TC colony forming units. 289 E. coli positive and 230 TC-only waters were successfully analyzed by individual qPCR assays for the aforementioned enteric pathogens. Microbial source tracking methods targeted to specific Bacteroides were used to determine the source of fecal contamination as either human or bovine. The source of fecal contamination varied by geographic region and is thought to be due to such things as differences in septic tank density and underlying geology, among others. Fecal indicators, E. coli and Bacteroides, were significantly correlated. E. coli as measured by qPCR was more strongly correlated to both total and human-specific Bacteroides genetic markers than culturable E. coli. Lastly, 1.9% of samples showed molecular evidence of contamination with enteric pathogens. Although low, this finding is significant given the limited volume of water available for testing, and suggests a potential health risk to consumers. Knowing the extent of contamination, as well as the biologic source, can better inform risk assessment and the development of potential intervention strategies for private well water in specific regions of Ontario.
Resumo:
The purpose of this study was to present a methodology with superior efficiency for inactivating pathogenic indicators commonly found in domestic sewage. The adopted method was based on synergistic effect resulting from the introduction of a UV radiation pre-disinfection stage of sewage followed by secondary treatment. A pilot unit was installed in the sewage treatment plant of the University of Sao Paulo to simulate the combined system in full-scale operational conditions. Its performance was evaluated through microbiological examinations for determining Escherichia coli, total coliforms and coliphages. The application of UV radiation at 5.1mW/cm(2) for 10 s of exposure in the first disinfection stage was enough to reduce the surviving number of E. coli around 100 times, in comparison to the conventional method. Therefore, based on experimental data, it is possible to conclude that combining treatment and pre-disinfection stage is an effective potential technique to produce effluents with lower degree of contamination by pathogenic organisms.
Resumo:
Minimally processed vegetables (MPV) may be important vehicles of Salmonella spp. and cause disease. This study aimed at detecting and enumerating Salmonella spp. in MPV marketed in the city of Sao Paulo, Brazil. A total of 512 samples of MPV packages collected in retail stores were tested for Salmonella spp. and total coliforms and Escherichia coil as indication of the hygienic status. Salmonella spp. was detected in four samples, two using the detection method and two using the counting method, where the results were 8.8 x 10(2) CFU/g and 2.4 x 10(2) CFU/g. The serovars were Salmonella Typhimurium (three samples) and Salmonella enterica subsp. enterica O:47:z4,z23:- (one sample). Fourteen samples (2.7%) presented counts of E. coli above the maximum limit established by the Brazilian regulation for MPV (10(2) CFU/g). Therefore, tightened surveillance and effective intervention strategies are necessary in order to address consumers and governments concerns on safety of MPV. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
This study aimed to verify the occurrence of Listeria monocytogenes and Salmonella spp. in raw milk produced in Brazil. On account of the poor microbiological quality of this product, possible interference from the indigenous microbiota in these pathogens was also evaluated. Two-hundred and ten raw milk samples were collected in four important milk-producing areas in Brazil, tested for L. monocytogenes and Salmonella spp. presence, and for enumeration of indicator microorganisms: mesophilic aerobes, total coliforms and Escherichia coli. The interference of the indigenous microbiota in the isolation procedures was also tested, as well the frequency of naturally occurring raw milk strains with antagonistic activity against both pathogens. The pathogens were not isolated in any raw milk sample, but poor microbiological quality was confirmed by the high levels of indicator microorganisms. When present at high levels, the indigenous microbiota generated an evident interference in the methodologies of L. monocytogenes and Salmonella spp. isolation, mainly when the pathogens appeared at low levels. Three-hundred and sixty raw milk strains were tested for antagonistic activity against both pathogens, and 91 (25.3%) showed inhibitory activity against L. monocytogenes and 33 (9.2%) against Salmonella spp. The majority of the antagonistic strains were identified as Lactic Acid Bacteria species, mainly Lactococcus lactis subsp. lactis and Enterococcus faecium, known by antimicrobial substance production.
Resumo:
The aim of the project was to determine the extent and quality of the groundwater in Tipperary South Riding with a view to developing a groundwater protection plan which would allow the Local Authority to manage, protect and develop the groundwater as efficiently as possible. The geology of the area varies with topography. The low-lying areas of the county comprise mainly Carboniferous limestones while the elevated regions consist of sandstones and shales of Upper Carboniferous, Devonian and Silurian ages. Deformation of these rocks decreases in magnitude moving northwards over the area; the Southern Synclines having suffered the effects of the Hercynian orogeny and the northern region exhibiting Caledonian orogenic trends. Quaternary (subsoil) deposits are found throughout the area and are of variable thickness and permeability. Till is the most widespread deposit with discontinuous pockets of sand and gravel in various proportions, and some marl, alluvium and peat in places. The principal aquifers of the area are the Kiltorcan sandstone formation and various limestone units within the Carboniferous succession. 50 % of south Tipperary constitutes either regionally or locally important aquifers. Secondary permeabilities created by structural deformation, dolomitisation, karstification and weathering processes create high transmissivities and often have large well yields. Specific baseflow analysis highlighted the complexity of the aquifers and proved that the lower part of the Suir river system is a major groundwater resource region. The hydrochemistry and water quality of the local authority groundwater sources was examined briefly. The majority of south Tipperary is underlain by limestone or Quaternary deposits derived from limestone and, consequently, calcium/magnesium bicarbonate waters predominate. The quality of the groundwater in south Tipperary demonstrates that the main concern originates from the presence of E.coli, and Total coliforms. The primary sources of contamination are from farmyard wastes and septic tanks. The vulnerability of groundwater to diffuse and point sources of pollution has been found to be dependent on the overlying soil, subsoil and the thickness of the unsaturated zone. A conceptual rather than quantitative approach is used and it is found that approximately 60% of south Tipperary is designated as being extremely or highly vulnerable. The groundwater protection plan was devised subsequent to an understanding of the aquifer systems, an assessment of the vulnerability, and a review of the Irish planning system and environmental law. It is recommended that the plan be integrated into the county development plan for legislative purposes. A series of acceptability matrices were devised to restrict potentially polluting activities in vulnerable areas while maintaining a balance between protection of the groundwater resource and the need to site essential developments.
Resumo:
Background. Determine the presence and evolution of indicators microorganisms of water pollution in “Conde del Guadalhorce” reservoir, Málaga city, Spain. A second objective was to analyze pollution degree and evaluate the sanitary quality of bathing water and compliance with European Directive 76/160/CE. Method. A total of 120 water samples were collected in two bathing freshwater sites during May to September sampling period between 2000 to 2005, and the numbers of total coliforms (CT), faecal coliforms (CF) and faecal streptococci (EF) were enumerated using the membrane filtration method. We used the log-normal distribution method and calculate the logarithmic means, percentile points, ratios CF:EF, ANOVA and Pearson correlations. Results. Only two samples overcome CF limit values at Camping sampling station during 2000 year. Ratios CF:EF values were higher (> 4) during 2000 to 2002, and lower (< 0,7) during 2003 to 2005. Significant differences (ANOVA F = 3,41, ∝ < 0,01) was only observed with EF during evaluated period. There was no significant difference between concentration means at bathing water sites (ANOVA, F = 3,395, ∝ < 0,01). The counts of CT and CF were significantly correlated in Kiosko water samples, while in Camping water, significant correlation (t = 0,632, p < 0,05) was only observed with EF at the Camping station during 2000, 2003 and 2005 years. Conclusions. “Conde del Guadalhorce” reservoir showed hygienic conditions for safety bathing. Globally, water bathing quality is good. CT, CF y EF indicators were agreed with UE Directive during 2000- 2005, with exception CF at Camping station in 2000 year. CT y CF concentrations at Camping were frecuently higher than Kiosko, it could be caused to swimmers abundance and recreational activities. There was a trend towards rising EF, it could be caused to faecal pollution source of animal origin, needed to research it.
Resumo:
Se realizaron 2 evaluaciones, en agosto y noviembre-diciembre 2010, entre la desembocadura del Dren 1000 (Bodegones) y la del río Zaña. En el intermareal se registró la mayor temperatura superficial del mar, se registró anomalías de hasta +8,1°C (desembocadura del Dren 1000). En agosto en el submareal, la temperatura promedio fue 16,3 °C; en noviembre-diciembre fue 15,9 °C. Similar tendencia en superficie y fondo se observó en el oxígeno disuelto. Mayor cantidad de sólidos suspendidos totales (SST) se registró alrededor de la desembocadura del Dren 4000 (137,93 mg/L), sobrepasando los límites permisibles para aguas de CEMC y AMC. Aceites y grasas fluctuaron entre 0 y 0,3 mg/L encontrándose dentro de los límites permisibles de CEMC y AMC. En el submareal, los Coliformes Totales (CT) y coliformes Termotolerantes (CTT) cumplieron con la Ley General de Aguas para la clase V y VI; en el intermareal la demanda bioquímica de oxigeno (DBO5) en la desembocadura del Dren 3100, sobrepasó los límites permisibles de calidad de agua. En agosto se registraron 39 especies en el bentos, en noviembre y diciembre fueron 27 especies. Los índices de diversidad de Shannon Wiener y riqueza de especies del macrobentos submareal, se incrementaron de norte a sur, debido al predominio del sustrato fango-arenoso. Los puntos de alteración ambiental fueron las desembocaduras de los drenes 1000, 3100 y 4000, que reciben aguas servidas y desechos orgánicos e industriales de los centros poblados de Lambayeque, Pimentel y Santa Rosa, respectivamente.
Resumo:
Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of "salt". Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of "salt", 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.
Resumo:
In this work, TiO2 photocatalysis was used to disinfect domestic wastewaters previously treated by different biological treatment systems: Upward-flow Anaerobic Sludge Blanket (UASB), facultative pond, and duckweed pond. The microorganisms monitored were E. coli, total coliforms, Shigella species, and Salmonella species. Photocatalytic experiments were carried out using two light sources: a solar simulator (UV intensity: 68-70 W m-2) and black-light lamps (BLL UV intensity: 17-20 W m-2). Samples were taken after each treatment stage. Results indicate that bacterial photocatalytic inactivation is affected by characteristics of the effluent, including turbidity, concentration of organic matter, and bacterial concentration, which depend of the type of biological pretreatment previously used.
Resumo:
The aim of this study was to identify, by multivariate statistical technique, the physic, chemical and biological variables that best characterize the quality of surface waters in two small rural catchments with different land uses (eucalyptus silviculture (SC) vs. pasture and extensive livestock (LC)) located in Rosário do Sul, RS - Brazil. Monitoring was conducted during the months of August 2011 to August 2012 and the following parameters were analyzed: Ca2+, Mg2+, K+, SO42-, Cl-, pH, electrical conductivity, turbidity, alkalinity, suspended and dissolved solids, biochemical oxygen demand , total coliforms, Escherichia coli and temperature, flow and rainfall. Through the use of FA/PCA, it was found that the model best fit to express water quality of in LC that was composed of five factors which account for 83.5% of the total variance, while for SC, four factors accounted for 85.12% of the variance. In LC, the five main factors were, respectively, soluble salts, diffuse pollution, solid, and both anthropogenic and organic factors. In SC, the four factors were namely: soluble salts, mineral, nutritional and diffuse pollution factors. The results of this study showed that by replacing the traditional soil usage (pasture and livestock) with planted forest, diffuse pollution was attenuated but, however, it did not result in major changes in the physical-chemical and biological characteristics of the water. Another point to note is that factorial analysis did not result in a large reduction in the number of variables, once the best model fit occurred with the addition of 15 of 18 analyzed variables (LC) and 17 of 18 analyzed variables (SC).
Resumo:
In this article it was evaluated the quality of water in the Cascavel river, in the city of Cascavel - Paraná using microbiological indicators, physical and chemical pollution and susceptibility / resistance in strains of Escherichia coli isolated antimicrobial trade. The water sampling was conducted between 2010-July and 2011-June at three points: a) near the source, b) urban area, c) rural area. The samples were analyzed for physical, chemical and microbiological variables: temperature, pH, color, turbidity, electrical conductivity, total nitrogen and total phosphorus, total coliforms (CT), fecal coliform (CTe) and Escherichia coli. Tests were also performed to nine antimicrobial commercial resistances. The variables studied indicated that the Cascavel river water was presented at disagreement with the resolution 357/2005 CONAMA (class I), ranking in the index as regular water quality. The physical, chemical and rainfall did not affect the growth of CT and CTe, with higher counts of E. coli in the urban area. The greatest resistance profiles of the strains of E. coli isolated from Cascavel river water was found in section 2, the urban area as a probable consequence of human influence on water quality.