Avaliação (em escala laboratorial) da aplicação do processo eletrolítico em efluente de lagoa de estabilização de esgoto urbano


Autoria(s): Claro,Elis Marina Turini; Otenio,Marcelo Henrique; Bidóia,Edério Dino; Silva,Natália Maria Maciel Guerra; Santos,Valdecir dos
Data(s)

01/01/2010

Resumo

Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of "salt". Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of "salt", 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000300012

Idioma(s)

pt

Publicador

Sociedade Brasileira de Química

Fonte

Química Nova v.33 n.3 2010

Palavras-Chave #electrolysis #treatment of effluent #disinfection
Tipo