956 resultados para Thermal Simulation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper aims at assessing the performance of a program of thermal simulation (Arquitrop) in different households in the city of Sao Paulo, Brazil. The households were selected for the Wheezing Project which followed up children under 2 years old to monitor the occurrence of respiratory diseases. The results show that in all three study households there is a good approximation between the observed and the simulated indoor temperatures. It was also observed a fairly consistent and realistic behavior between the simulated indoor and the outdoor temperatures, describing the Arquitrop model as an efficient estimator and good representative of the thermal behavior of households in the city of Sao Paulo. The worst simulation is linked to the poorest type of construction. This may be explained by the bad quality of the construction, which the Architrop could not simulate adequately.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Die in dieser Arbeit durchgeführten Untersuchungen zeigen, daß es möglich ist, komplexe thermische Systeme, unter Verwendung der thermisch-, elektrischen Analogien, mit PSpice zu simulieren. Im Mittelpunkt der Untersuchungen standen hierbei Strangkühlkörper zur Kühlung von elektronischen Bauelementen. Es konnte gezeigt werden,daß alle Wärmeübertragungsarten, (Wärmeleitung, Konvektion und Wärmestrahlung) in der Simulation berücksichtigt werden können. Für die Berechnung der Konvektion wurden verschiedene Methoden hergeleitet. Diese gelten zum einen für verschiedene Kühlkörpergeometrien, wie z.B. ebene Flächen und Kühlrippenzwischenräume, andererseits unterscheiden sie sich, je nachdem, ob freie oder erzwungene Konvektion betrachtet wird. Für die Wärmestrahlung zwischen den Kühlrippen wurden verschiedenen Berechnungsmethoden entwickelt. Für die Simulation mit PSpice wurde die Berechnung der Wärmestrahlung zwischen den Kühlrippen vereinfacht. Es konnte gezeigt werden, daß die Fehler, die durch die Vereinfachung entstehen, vernachlässigbar klein sind. Für das thermische Verhalten einer zu kühlenden Wärmequelle wurde ein allgemeines Modell entworfen. Zur Bestimmung der Modellparameter wurden verschiedene Meßverfahren entwickelt. Für eine im Fachgebiet Elektromechanik entwickelte Wärmequelle zum Test von Kühlvorrichtungen wurde mit Hilfe dieser Meßverfahren eine Parameterbestimmung durchgeführt. Die Erstellung des thermischen Modells eines Kühlkörpers für die Simulation in PSpice erfordert die Analyse der Kühlkörpergeometrie. Damit diese Analyse weitestgehend automatisiert werden kann, wurden verschiedene Algorithmen unter Matlab entwickelt. Es wurde ein Algorithmus entwickelt, der es ermöglicht, den Kühlkörper in Elementarzellen zu zerlegen, die für die Erstellung des Simulationsmodells benötigt werden. Desweiteren ist es für die Simulation notwendig zu wissen, welche der Elementarzellen am Rand des Kühlkörpers liegen, welche der Elementarzellen an einem Kühlrippenzwischenraum liegen und welche Kühlkörperkanten schräg verlaufen. Auch zur Lösung dieser Aufgaben wurden verschiedene Algorithmen entwickelt. Diese Algorithmen wurden zu einem Programm zusammengefaßt, das es gestattet, unterschiedliche Strangkühlkörper zu simulieren und die Simulationsergebnisse in Form der Temperaturverteilung auf der Montagefläche des Kühlkörpers grafisch darzustellen. Es können stationäre und transiente Simulationen durchgeführt werden. Desweiteren kann der thermische Widerstand des Kühlkörpers RthK als Funktion der Verlustleistung der Wärmequelle dargestellt werden. Zur Verifikation der Simulationsergebnisse wurden Temperaturmessungen an Kühlkörpern durchgeführt und mit den Simulationsergebnissen verglichen. Diese Vergleiche zeigen, daß die Abweichungen im Bereich der Streuung der Temperaturmessung liegen. Das hier entwickelte Verfahren zur thermischen Simulation von Strangkühlkörpern kann somit als gut bewertet werden.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The general aim of this work is to contribute to the energy performance assessment of ventilated façades by the simultaneous use of experimental data and numerical simulations. A significant amount of experimental work was done on different types of ventilated façades with natural ventilation. The measurements were taken on a test building. The external walls of this tower are rainscreen ventilated façades. Ventilation grills are located at the top and at the bottom of the tower. In this work the modelling of the test building using a dynamic thermal simulation program (ESP-r) is presented and the main results discussed. In order to investigate the best summer thermal performance of rainscreen ventilated skin façade a study for different setups of rainscreen walls was made. In particular, influences of ventilation grills, air cavity thickness, skin colour, skin material, orientation of façade were investigated. It is shown that some types of rainscreen ventilated façade typologies are capable of lowering the cooling energy demand of a few percent points.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This thesis presents a methodology for measuring thermal properties in situ, with a special focus on obtaining properties of layered stack-ups commonly used in armored vehicle components. The technique involves attaching a thermal source to the surface of a component, measuring the heat flux transferred between the source and the component, and measuring the surface temperature response. The material properties of the component can subsequently be determined from measurement of the transient heat flux and temperature response at the surface alone. Experiments involving multilayered specimens show that the surface temperature response to a sinusoidal heat flux forcing function is also sinusoidal. A frequency domain analysis shows that sinusoidal thermal excitation produces a gain and phase shift behavior typical of linear systems. Additionally, this analysis shows that the material properties of sub-surface layers affect the frequency response function at the surface of a particular stack-up. The methodology involves coupling a thermal simulation tool with an optimization algorithm to determine the material properties from temperature and heat flux measurement data. Use of a sinusoidal forcing function not only provides a mechanism to perform the frequency domain analysis described above, but sinusoids also have the practical benefit of reducing the need for instrumentation of the backside of the component. Heat losses can be minimized by alternately injecting and extracting heat on the front surface, as long as sufficiently high frequencies are used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Vertical vegetation is vegetation growing on, or adjacent to, the unused sunlit exterior surfaces of buildings in cities. Vertical vegetation can improve the energy efficiency of the building on which it is installed mainly by insulating, shading and transpiring moisture from foliage and substrate. Several design parameters may affect the extent of the vertical vegetation's improvement of energy performance. Examples are choice of vegetation, growing medium geometry, north/south aspect and others. The purpose of this study is to quantitatively map out the contribution of several parameters to energy savings in a subtropical setting. The method is thermal simulation based on EnergyPlus configured to reflect the special characteristics of vertical vegetation. Thermal simulation results show that yearly cooling energy savings can reach 25% with realistic design choices in subtropical environments. Heating energy savings are negligible. The most important parameter is the aspect of walls covered by vegetation. Vertical vegetation covering walls facing north (south for the northern hemisphere) will result in the highest energy savings. In making plant selections, the most significant parameter is Leaf Area Index (LAI). Plants with larger LAI, preferably LAI>4, contribute to greater savings whereas vertical vegetation with LAI<2 can actually consume energy. The choice of growing media and its thickness influence both heating and cooling energy consumption. Change of growing medium thickness from 6cm to 8cm causes dramatic increase in energy savings from 2% to 18%. For cooling, it is best to use a growing material with high water retention, due to the importance of evapotranspiration for cooling. Similarly, for increased savings in cooling energy, sufficient irrigation is required. Insufficient irrigation results in the vertical vegetation requiring more energy to cool the building. To conclude, the choice of design parameters for vertical vegetation is crucial in making sure that it contributes to energy savings rather than energy consumption. Optimal design decisions can create a dramatic sustainability enhancement for the built environment in subtropical climates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The refractive indices of crystalline phase-change films are usually obtained by thermal-induced crystallization. However, this is not accurate, because the crystallization of phase-change film in rewritable optical disks is laser induced. In this study, we use the initializer to crystallize the phase-change films. The dependence of the refractive index n and the extinction coefficient k of the phase-change films on the initialization conditions are studied. Remarkable changes of the refractive indices (especially k) are found when the initialization laser power density is 6.63 mW/mum(2) and the initialization velocity is 4.0 m/s. At the same time, the structure changes of the phase-change films are also studied. This dependence is explained by the structure change of the films. These results are significant in improving the accuracy of optical design and the thermal simulation of phase-change optical disks, as well as in the study of phase-change optical disks at shorter wavelengths. (C) 2003 Society of Photo-Optical Instrumentation Engineers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Neste trabalho é apresentado o desenvolvimento de um programa computacional que simula o desempenho térmico de um sistema de aquecimento solar de água com circulação forçada, adequado para uso em edificações. O programa trabalha realizando o balanço de massa e de energia no reservatório térmico a cada hora, tendo como valores de entrada dados do ano meteorológico típico da localidade selecionada e a vazão de água quente de consumo. Os componentes do sistema são o reservatório térmico de água quente com aquecedor auxiliar interno, o coletor solar e a bomba de circulação. A base de dados meteorológicos escolhida foi a do projeto SWERA, que contém arquivos no formato padrão TMY disponíveis na internet para um número considerável de cidades, incluindo diversas localidades brasileiras. Foi proposto um modelo de temperatura de água da rede de abastecimento relacionado com a temperatura do solo, dado disponível nos arquivos de entrada utilizados. O programa utilizou como referência para a validação dos modelos de cálculo resultados obtidos pelo programa comercial de simulação TRNSYS. Foram comparados resultados para os modelos de irradiação incidente em superfície inclinada, do coletor solar e do sistema completo. Para isto foram simulados sistemas localizados em quatro cidades distintas com climas diferentes. O tempo total usado nas simulações foi de um ano e os resultados das comparações dos valores resultantes foram considerados satisfatórios.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta dissertação apresenta a avaliação térmica, econômica e ambiental de um sistema de aquecimento solar (SHS) que é usado em uma usina de asfalto, através de simulação computacional com TRNSYS. O processo escolhido é o aquecimento do betume a partir da temperatura de armazenamento até a temperatura de mistura, usando óleo mineral como fluido de transferência de calor (HTF). Os componentes do sistema são o trocador de calor HTF-betume, o coletor concentrador solar parabólico composto (CPC), o aquecedor auxiliar e a bomba de circulação. A simulação no TRNSYS calcula os balanços de massa e energia no circuito fechado do HTF a cada hora. Dados horários do Ano Meteorológico Típico (TMY) do Rio de Janeiro foram utilizados para executar este trabalho. Em muitos casos, a temperatura do HTF ultrapassou 238C, mostrando que o CPC é apropriado para esta aplicação. Economia de combustível e emissões evitadas foram consideradas para as análises economica e ambiental. Este trabalho descreve as fontes renováveis de energia, os tipos de usinas de asfalto e de aquecedores de betume. Ele também mostra a fração brasileira de algumas destas fontes. Os resultados, portanto, mostram ser possível encorajar políticas públicas ambientalmente corretas para incentivar o uso de energia solar na indústria de asfalto. Além disso, este trabalho pode ajudar na redução da elevada emissão dos gases de efeito estufa a partir da utilização dos combustíveis fósseis nesta indústria.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Time-dependent thermal simulation of ridge-geometry InGaN laser diodes is carried out with a two-dimensional model. A high temperature in the waveguide layer and a large temperature step between the regions under and outside the ridge are generated due to the poor thermal conductivity of the sapphire substrate and the large threshold current and voltage. The temperature step is thought to have a strong influence on the characteristics of the laser diodes. Time-resolved measurements of light-current curves,spectra, and the far-field pattern of the InGaN laser diodes under pulsed operation are performed. The results show that the thermal lensing effect improves the confinement of the higher order modes and leads to a lower threshold current and a higher slope efficiency of the device while the high temperature in the active layer results in a drastic decrease in the slope efficiency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Natural gas pays more important role in the society as clean fuel. Natural gas exploration has been enhanced in recent years in many countries. It also has prospective future in our country through "85" and "95" national research. Many big size gas fields have been discovered in different formations in different basins such as lower and upper Paleozoic in Erdos basin, Tertiary system in Kuche depression in Tarim basin, Triassic system in east of Sichuan basin. Because gas bearing basins had been experienced multiple tectogenesis. The characteristics of natural gases usually in one gas field are that they have multiple source rocks and are multiple maturities and formed in different ages. There has most difficult to research on the gas-rock correlation and mechanism of gas formation. Develop advanced techniques and methods and apply them to solve above problems is necessary. The research is focused on the critical techniques of geochemistry and physical simulation of gas-rock correlation and gas formation. The lists in the following are conclusions through research and lots of experiments. I 8 advanced techniques have been developed or improved about gas-rock correlation and gas migration, accumulation and formation. A series of geochemistry techniques has been developed about analyzing inclusion enclave. They are analyzing gas and liquid composition and biomarker and on-line individual carbon isotope composition in inclusion enclave. These techniques combing the inclusion homogeneous temperature can be applied to study on gas-rock correlation directly and gas migration, filling and formation ages. Technique of on-line determination individual gas carbon isotope composition in kerogen and bitumen thermal pyrolysis is developed. It is applied to determine the source of natural is kerogen thermal degradation or oil pyrolysis. Method of on-line determination individual gas carbon isotope composition in rock thermal simulation has being improved. Based on the "95"former research, on-line determination individual gas carbon isotope composition in different type of maceral and rocks thermal pyrolys is has been determined. The conclusion is that carbon isotope composition of benzene and toluene in homogenous texture kerogen thermal degradation is almost same at different maturity. By comparison, that in mixture type kerogen thermal pyrolysis jumps from step to step with the changes of maturity. This conclusion is a good proof of gas-rock dynamic correlation. 3. Biomarker of rock can be determined directly through research. It solves the problems such as long period preparing sample, light composition losing and sample contamination etc. It can be applied to research the character of source rock and mechanism of source rock expulsion and the path of hydrocarbon migration etc. 4. The process of hydrocarbon dynamic generation in source rock can be seen at every stage applying locating observation and thermal simulation of ESEM. The mechanism of hydrocarbon generation and expulsion in source rock is discussed according to the experiments. This technique is advanced in the world. 5. A sample injection system whose character is higher vacuum, lower leaks and lower blank has been built up to analyze inert gas. He,Ar,Kr and Xe can be determined continuously on one instrument and one injection. This is advanced in domestic. 7. Quality and quantity analysis of benzene ring compounds and phenolic compounds and determination of organic acid and aqueous gas analysis are applied to research the relationship between compounds in formation water and gas formation. This is another new idea to study the gas-rock correlation and gas formation. 8. Inclusion analysis data can be used to calculate the Paleo-fluid density, Paleo-geothermal gradient and Paleo-geopressure gradient and then to calculate the Paleo-fluid potential. It's also a new method to research the direction of hydrocarbon migration and accumulation. 9. Equipment of natural gas formation simulation is produced during the research to probe how the physical properties of rock affect the gas migration and accumulation and what efficiency of gas migrate and factors of gas formation and the models of different type of migration are. II study is focused on that if the source rocks of lower Paleozoic generated hydrocarbon and what the source rocks of weathered formation gas pool and the mechanism of gas formation are though many advanced techniques application. There are four conclusions. 1.The maturity of Majiagou formation source rocks is higher in south than that in north. There also have parts of the higher maturity in middle and east. Anomalous thermal pays important role in big size field formation in middle of basin. 2. The amount of gas generation in high-over maturity source rocks in lower Paleozoic is lager than that of most absorption of source rocks. Lower Paleozoic source rocks are effective source rocks. Universal bitumen exists in Ordovician source rocks to prove that Ordovician source rocks had generated hydrocarbon. Bitumen has some attribution to the middle gas pool formation. 3. Comprehensive gas-rock correlation says that natural gases of north, west, south of middle gas field of basin mainly come from lower Paleozoic source rocks. The attribution ratio of lower Paleozoic source rocks is 60%-70%. Natural gases of other areas mainly come from upper Paleozoic. The attribution ratio of upper Paleozoic source rocks is 70%. 4. Paleozoic gases migration phase of Erdos basin are also interesting. The relative abundance of gasoline aromatic is quite low especially toluene that of which is divided by that of methyl-cyclohexane is less than 0.2 in upper Paleozoic gas pool. The migration phase of upper Paleozoic gas may be aqueous phase. By comparison, the relative abundance of gasoline aromatic is higher in lower Paleozoic gas. The distribution character of gasoline gas is similar with that in source rock thermal simulation. The migration phase of it may be free phase. IH Comprehensive gas-rock correlation is also processed in Kuche depression Tarim basin. The mechanism of gas formation is probed and the gas formation model has been built up. Four conclusions list below. 1. Gases in Kuche depression come from Triassic-Jurassic coal-measure source rocks. They are high-over maturity. Comparatively, the highest maturity area is Kelasu, next is Dabei area, Yinan area. 2. Kerogen thermal degradation is main reason of the dry gas in Kuche depression. Small part of dry gas comes from oil pyrolysis. VI 3.The K12 natural gas lays out some of hydro-gas character. Oil dissolved in the gas. Hydro-gas is also a factor making the gas drier and carbon isotope composition heavier. 4. The mechanism and genesis of KL2 gas pool list as below. Overpressure has being existed in Triassic-Jurassic source rocks since Keche period. Natural gases were expulsed by episode style from overpressure source rocks. Hetero-face was main migration style of gas, oil and water at that time. The fluids transferred the pressure of source rocks when they migrated and then separated when they got in reservoir. After that, natural gas migrated up and accumulated and formed with the techno-genesis. Tectonic extrusion made the natural gas overpressure continuously. When the pressure was up to the critical pressure, the C6-C7 composition in natural gas changed. The results were that relative abundance of alkane and aromatic decreased while cycloalkane and isoparaffin increased. There was lots of natural gas filling during every tectonic. The main factors of overpressure of natural gas were tectonic extrusion and fluid transferring pressure of source rocks. Well preservation was also important in the KL2 gas pool formation. The reserves of gas can satisfy the need of pipeline where is from west to east. IV A good idea of natural gas migration and accumulation modeling whose apparent character is real core and formation condition is suggested to model the physical process of gas formation. Following is the modeling results. 1. Modeling results prove that the gas accumulation rule under cap layer and gas fraction on migration path. 2. Natural gas migration as free phase is difficult in dense rock. 3. Natural gases accumulated easily in good physical properties reservoirs where are under the plugging layer. Under the condition of that permeability of rock is more than 1 * 10~(-3)μm~(-1), the more better the physical properties and the more bigger pore of rock, the more easier the gas accumulation in there. On the contrary, natural gas canonly migrate further to accumulate in good physical properties of rock. 4. Natural gas migrate up is different from that down. Under the same situation, the amount of gas migration up is lager than that of gas migration down and the distance of migration up is 3 times as that of migration down. 5. After gas leaks from dense confining layer, the ability of its dynamic plug-back decreased apparently. Gas lost from these arils easily. These confining layer can confine again only after geology condition changes. 6. Water-wetted and capillary-blocking rocks can't block water but gases generally. The result is that water can migrate continuously through blocking rocks but the gases stay under the blocking rocks then form in there. The experiments have proved the formation model of deep basin gas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dado o panorama de conservação de energia a nível nacional e mundial, torna-se hoje em dia muito importante, que seja possível controlar e estimar o consumo energético nos edifícios. Assim, atendendo à actual problemática energética e ao crescente consumo energético nos edifícios, é importante parametrizar, avaliar e comparar este consumo. Neste sentido, nas últimas décadas, têm sido efectuados desenvolvimentos técnicos, quer ao nível do equipamento de campo para efectuar monitorização e medição, quer ao nível da simulação dinâmica de edifícios. Com esta dissertação de mestrado, pretendeu-se efectuar a simulação dinâmica de um edifício escolar existente a funcionar em pleno, e efectuar uma análise de sensibilidade relativamente ao grau de variação dos resultados obtidos através da aplicação de dois programas de cálculo térmico e energético. Foram utilizados, o programa VE-Pro da IES (Integrated Environmental Solutions) e o programa Trace 700 da TRANE. Ambos os programas foram parametrizados com os mesmos dados de entrada, tendo em atenção as opções de simulação disponibilizadas por ambos. Posteriormente, utilizaram-se os dados retirados da simulação para calcular a classificação energética no âmbito do sistema de certificação energética (SCE), através de uma folha de cálculo desenvolvida para o efeito. Foram ainda consideradas várias soluções de eficiência energética para o edifício, com vista a poupanças reais de energia, tendo sempre atenção ao conforto térmico dos ocupantes. Dessas medidas fazem parte, medidas relacionadas com a iluminação, como a substituição da iluminação existente por luminárias do tipo LED (Light Emitting Diode), soluções de energias renováveis, como a instalação de colectores solares para aquecimento das águas quentes sanitárias, e painéis fotovoltaicos para produção de energia, bem como medidas ligadas aos equipamentos de climatização. Posteriormente, recalculou-se a classificação energética afectada das melhorias. Os resultados obtidos nas duas simulações foram analisados sob o ponto de vista do aquecimento, arrefecimento, ventilação, iluminação e equipamentos eléctricos. A comparação das duas simulações para cada parâmetro acima referido, apresentaram variações inferiores a 5%. O desvio maior verificou-se na ventilação, com o valor de aproximadamente 4,9%. Transpondo estes resultados para o cálculo do IEE (Índice de Eficiência Energética), verificou-se um desvio inferior a 2%.