950 resultados para Test results
Resumo:
This study reports on a sample of normal Australian elderly who were assessed for naming ability using the Boston Naming Test (BNT). The study aimed to examine and compare the changes in naming ability, using both longitudinal and cross-sectional analysis, and determine the relationships between naming ability and age, educational level, visual acuity and gender and cultural relevance. Contradictory findings were produced regarding age and were dependent on the research design. Longitudinal analysis showed no age-related change in naming ability in subjects over a four-period. In contrast, cross-sectional analysis showed a weak but significant correlation between age and naming ability. Educational level, visual acuity and gender were unrelated to changes in naming ability over time, and unrelated to naming ability across the cohort of elderly. The Australian elderly performed better on the modified Australian version of the BNT than on the original American version. Thus, clinicians need to be cautious when interpreting the results of the BNT for elderly and for populations outside North America. The results of this study also indicate a need for further longitudinal research of a greater duration to establish age-related decline in naming ability.
Resumo:
OBJECTIVE: To assess individual and/or health service factors associated with patients returning for results of HIV or sexually transmitted infection (STI) tests in mental health centers. METHODS: Cross-sectional national multicenter study among 2,080 patients randomly selected from 26 Brazilian mental health centers in 2007. Multilevel logistic regression was used to assess the effect of individual (level 1) and mental health service characteristics (level 2) on receipt of test results. RESULTS: The rate of returning HIV/STI test results was 79.6%. Among health service characteristics examined, only condom distribution was associated with receiving HIV/STI test results, whereas several individual characteristics were independently associated including living in the same city where treatment centers are; being single; not having heard of AIDS; and not having been previously HIV tested. CONCLUSIONS: It is urgent to expand HIV/STI testing in health services which provide care for patients with potentially increased vulnerability to these conditions, and to promote better integration between mental health and health services.
Resumo:
Latent tuberculosis was studied in a research laboratory. A prevalence of positive tuberculin skin test results (> 15mm) of 20% was found and the main predictors were place of birth in a foreign country with high prevalence of tuberculosis and a history of contact with patients with untreated active tuberculosis.
Resumo:
This leaflet is used to support the Northern Ireland breast screening programme and is issued to the one in 20 women who are called back after their initial breast x-ray for further tests at a breast assessment clinic
Resumo:
Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.
Resumo:
All noncomplying penetration and absolute viscosity results must be verified before being reported. This verification of test results is done by reheating and retesting the identical sample that is suspect. The District Laboratories are required to submit penetration and absolute viscosity correlation samples to the Central Laboratory. These samples are the identical ones tested by the District Laboratories. When the Central laboratory tests these correlation samples they are also considered to be reheated and retested. Reheating a sample will harden the asphalt to some degree and possibly cause a change in the test results. This investigation was conducted to determine how much change in penetration and absolute viscosity could be expected by reheating and retesting asphalt samples.
Resumo:
Currently, no standard mix design procedure is available for CIR-emulsion in Iowa. The CIR-foam mix design process developed during the previous phase is applied for CIR-emulsion mixtures with varying emulsified asphalt contents. Dynamic modulus test, dynamic creep test, static creep test and raveling test were conducted to evaluate the short- and long-term performance of CIR-emulsion mixtures at various testing temperatures and loading conditions. A potential benefit of this research is a better understanding of CIR-emulsion material properties in comparison with those of CIR-foam material that would allow for the selection of the most appropriate CIR technology and the type and amount of the optimum stabilization material. Dynamic modulus, flow number and flow time of CIR-emulsion mixtures using CSS- 1h were generally higher than those of HFMS-2p. Flow number and flow time of CIR-emulsion using RAP materials from Story County was higher than those from Clayton County. Flow number and flow time of CIR-emulsion with 0.5% emulsified asphalt was higher than CIR-emulsion with 1.0% or 1.5%. Raveling loss of CIR-emulsion with 1.5% emulsified was significantly less than those with 0.5% and 1.0%. Test results in terms of dynamic modulus, flow number, flow time and raveling loss of CIR-foam mixtures are generally better than those of CIR-emulsion mixtures. Given the limited RAP sources used for this study, it is recommended that the CIR-emulsion mix design procedure should be validated against several RAP sources and emulsion types.
Resumo:
Interferon-gamma release assays for the diagnosis of tuberculosis (TB) can give indeterminate results. The prevalence of indeterminate test results (ITRs) among T-SPOT.TB tests was assessed. A retrospective analysis of samples processed in 2005 was performed. ITRs were assessed by age, sex, immunosuppression, distance to the laboratory and season. A subgroup of tests performed for specific indications (contact tracing, migrants with positive tuberculin skin test, TB suspects and immunosuppression) were analysed separately. Of a total of 1,429 tests, 49 (3.4%) were indeterminate. ITRs were significantly associated with old age (>75 versus 5-75 yrs; odds ratio (OR) 7.97, 95% confidence interval (CI) 3.968-15.438) and the season during which samples were transported (autumn and winter versus spring and summer; OR 3.47, 95% CI 1.753-7.514). The incidence of ITR was 302 (2.0%) among TB contacts, 75 (1.6%) among immigrants, 156 (3.0%) in TB suspects and 32 (3.0%) among immunosuppressed patients. Sex, young age and distance to the laboratory were not associated with the rate of ITR. Of the 13 tests with ITR that were repeated, 10 gave a clear positive or negative result. Indeterminate test results with T-SPOT.TB under routine conditions were infrequent and more common in individuals aged >75 yrs than in children and younger adults. The incidence of indeterminate test results was low and similar among healthy tuberculosis contacts, immigrants with a positive tuberculin skin test, tuberculosis suspects and the immunosuppressed. The conditions of transportation may influence the incidence of indeterminate test results.
Resumo:
Coronary artery disease (CAD) is a worldwide leading cause of death. The standard method for evaluating critical partial occlusions is coronary arteriography, a catheterization technique which is invasive, time consuming, and costly. There are noninvasive approaches for the early detection of CAD. The basis for the noninvasive diagnosis of CAD has been laid in a sequential analysis of the risk factors, and the results of the treadmill test and myocardial perfusion scintigraphy (MPS). Many investigators have demonstrated that the diagnostic applications of MPS are appropriate for patients who have an intermediate likelihood of disease. Although this information is useful, it is only partially utilized in clinical practice due to the difficulty to properly classify the patients. Since the seminal work of Lotfi Zadeh, fuzzy logic has been applied in numerous areas. In the present study, we proposed and tested a model to select patients for MPS based on fuzzy sets theory. A group of 1053 patients was used to develop the model and another group of 1045 patients was used to test it. Receiver operating characteristic curves were used to compare the performance of the fuzzy model against expert physician opinions, and showed that the performance of the fuzzy model was equal or superior to that of the physicians. Therefore, we conclude that the fuzzy model could be a useful tool to assist the general practitioner in the selection of patients for MPS.
Resumo:
Objective: To compare results from various tapping tests with diary responses in advanced PD. Background: A home environment test battery for assessing patient state in advanced PD, consisting of diary assessments and motor tests was constructed for a hand computer with touch screen and mobile communication. The diary questions: 1. walking, 2. time in off , on and dyskinetic states, 3. off at worst, 4. dyskinetic at worst, 5. cramps, and 6. satisfied with function, relate to the recent past. Question 7, self-assessment, allows seven steps from -3 ( very off ) to +3 ( very dyskinetic ) and relate to right now. Tapping tests outline: 8. Alternately tapping two fields (un-cued) with right hand 9. Same as 8 but using left hand 10. Tapping an active field (out of two) following a system-generated rhythm (increasing speed) with the dominant hand 11. Tapping an active field (out of four) that randomly changes location when tapped using the dominant hand Methods: 65 patients (currently on Duodopa, or candidates for this treatment) entered diary responses and performed tapping tests four times per day during one to six periods of seven days length. In total there were 224 test periods and 6039 test occasions. Speed for tapping test 10 was discardedand tests 8 and 9 were combined by taking means. Descriptive statistics were used to present the variation of the test variables in relation to self assessment (question 7). Pearson correlation coefficients between speed and accuracy (percent correct) in tapping tests and diary responses were calculated. Results: Mean compliance (percentage completed test occasions per test period) was 83% and the median was 93%. There were large differences in both mean tapping speed and accuracy between the different self-assessed states. Correlations between diary responses and tapping results were small (-0.2 to 0.3, negative values for off-time and dyskinetic-time that had opposite scale directions). Correlations between tapping results were all positive (0.1 to 0.6). Conclusions: The diary responses and tapping results provided different information. The low correlations can partly be explained by the fact that questions related to the past and by random variability, which could be reduced by taking means over test periods. Both tapping speed and accuracy reflect the motor function of the patient to a large extent.
Resumo:
A single-phase superconducting Fault Current Limiter using a bifilar coil of BSCCO-2212 tube was tested in 220 V-60 Hz line during fault current between 1 kA to 4 kA, operating in 77 K. In this work are presented the critical current dependence as a function of an external magnetic field applied and the results can be used to predict the current limiter performance. The experimental setup is described and the test results are presented for the unit conducting a steady nominal AC current of 200 A, and also during the fault time (1 to 6 cycles). The performance of the bifilar coil to provide the limiting impedance associated with the dynamic resistance developed during the beginning of the fault was analyzed and compared with other types of superconducting current limiters.
Resumo:
A single-phase superconducting fault current limiter (SFCL) using a 0.9 m length of YBCO coated conductor (CC) tape was tested in 220 V-60 Hz line for fault current up to 1 kA, operating in 77 K. In this work are presented the IN experimental curves measured under DC and AC currents for the electrical characterization of the CC tape in order to design a low voltage current limiter. The experimental setup is described and the test results are presented for a unit conducting a steady nominal AC current of 50 A and also during the fault time (I to 5 cycles.) the performance of the CC-based SFCL providing the limiting resistance developed in the whole tape length after few milliseconds of the beginning of the fault was analyzed.
Resumo:
A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper. © 2010 IOP Publishing Ltd.