1000 resultados para Termografia de infravermelho


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aimed to study the relationship between scrotal temperature on semen quality by use of infrared thermography in Nelore bulls bred extensively. There were scrotal thermography and semen collection. Climatic data were collected by means of globe thermometer. The thermograms of the scrotum were obtained by digital infrared thermography. We carried out ejaculates through electroejaculation for analysis of quantitative and qualitative characteristics. For the data, we used analysis of variance and subsequently applied the Tukey test at 5%. (p <0.05) between animals for sperm vigor, sperm motility between animals and between crops, sperm concentration, total sperm and total viable sperm between groups, between harvests for the scrotum temperatures and climate data. It was concluded that the surface temperatures of the scrotum and climatic factors influence the quality of semen. Thermography is recommended as a complementary test in the evaluation of reproductive bulls.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Desde que saiu do secretismo militar, nas últimas décadas do século passado, a termografia infravermelha, tem vindo a ampliar a sua aplicação em todas as áreas. A experiência de obtenção de assinaturas térmicas de equipamentos militares e de toda a actividade militar, foram transpostas para outras áreas de actividade e com elas todas as ferramentas de análise. O desenvolvimento e vulgarização da informática e a concorrência entre marcas, com a consequente diminuição de custos, facilitou a sua divulgação. Na manutenção preventiva, quando correctamente utilizada, a termografia infravermelha, é um excelente auxiliar, tendo a vantagem de ser uma ferramenta segura, versátil, de não contacto e que proporciona grande rapidez de observação. No presente trabalho é passado em revisão o estado da arte no campo específico do tema da dissertação e foram estudados os princípios da termografia. Foram realizados três trabalhos de campo, traduzidos por outras tantas inspecções termográficas em empresas metolomecânicas e foram recolhidas imagens de exterior do edifício do ISEL e do parque de estacionamento. Foram ainda realizados ensaios de laboratório sobre desalinhamento angular onde foram obtidas imagens termográficas da fase de arranque até ao aquecimento do modelo com os veios alinhados a duas rotações distintas e com dois desalinhamentos angulares diferentes. Foi ainda executado um terceiro ensaio com os veis desalinhados, para confirmação de valores. Face aos resultados, o natural desenvolvimento deste trabalho aponta para a continuação dos ensaios neste campo de forma a confirmar os valores obtidos e estabelecer factores de correcção para diferentes condições de desalinhamento e temperatura ambiente.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Em Portugal a execução de coberturas planas é muito corrente. No entanto, apesar das evoluções positivas que, nas últimas décadas, este tipo de coberturas tem tido a nível de materiais e soluções construtivas, continuam a surgir anomalias associadas à impermeabilização que resultam, em geral, em infiltrações de água através da cobertura. Para detectar precocemente estas anomalias desenvolveu-se uma metodologia de análise não destrutiva através da utilização de termografia de infravermelhos (TIV). A metodologia permite, através da medição da radiação emitida pela superfície da cobertura, identificar heterogeneidades de temperatura que podem resultar da presença de espaços de ar e/ou água sob o sistema de revestimento da impermeabilização. Neste artigo apresentam-se os principais resultados obtidos no âmbito desta investigação, que permitiram comprovar a sensibilidade do método da TIV na detecção e mapeamento das anomalias no sistema de impermeabilização de coberturas planas

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Poultry facilities must provide an environment that ensures thermal comfort allowing the animal to express its genetic potential for production; and new tools are being applied to measure the thermal comfort, especially thermal cameras. The objective of this study was to evaluate the association of the surface temperature of the birds with those from the facilities, and estimate the sensible heat transfer. For this, the thermal conditions of rearing in two aviaries with different ventilation systems, during the period of March to April 2011 were recorded. The aviaries were divided into six quadrants for the registration of surface temperatures obtained using an infrared thermal camera. In each quadrant the ambient temperature, relative humidity and wind velocity during the obtention of images were also recorded. It was observed that the surface temperatures of birds are associated with the surface temperature of the rearing facilities (side curtains, roof and litter). In aviary with negative pressure higher wind speeds compared to the conventional one were recorded and; therefore, allowed a higher sensible heat transfer by birds, suggesting that this provided better conditions for thermal comfort.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A Temperatura da Superfície Terrestre (TST), além de ser uma componente importante no balanço de energia na superfície, modula a temperatura do ar nas camadas mais baixas da atmosfera. O objetivo do presente trabalho foi analisar a variação da temperatura de superfície em Diferentes Usos e Cobertura do Solo na Floresta Nacional do Tapajós e seu Entorno. Utilizou-se sensores ?Thermal Infrared Sensor? dos satélites Ladsat 5 e 8 através dos ?softwares? PCI Geomatica 2015 e o QGis 2.8. Fez-se campanha de campo para obtenção de imagens termogéficas no infravermelho (câmera ThermoVision, modelo A320). Os resultados apontaram maior variabilidade espacial de TST em função da heterogeneidade do uso da terra como a agricultura anual, pecuária extensiva, dentre outros. Os resultados evidenciaram uma amplitude térmica de 13ºC na FNT+ZA. Em área de Floretas, vegetação secundária, pasto, agricultura anual as maiores variações térmicas (TST) chegaram a valores de 25ºC, 26ºC, 35ºC e 33ºC, respectivamente. A amplitude térmica na FNT foi de 5ºC e na Zona de Amortecimento de 20º, indicando perdas na cobertura vegetal, principalmente na porção nordeste da ZA. Nas áreas de proteção legal a variação de TST foi entre 19ºC a 29ºC. Conclui-se que na FLONA Tapajós a manutenção da cobertura florestal reduz as amplitudes térmicas. Por outro lado, as extensas áreas com pastagens e cultivos anuais na porção nordeste da FLONA apresentam as maiores variações espaciais da TST na Zona de Amortecimento que podem comprometer o microclima na FNT+ZA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Infrared spectroscopy (IR spectroscopy) explores the infrared region of the electromagnetic spectrum. Like any other spectroscopic technique, it can be used to identify a compound or the composition of investigate a sample. Spectroscopy (IR) is a very important technique in qualitative chemical analysis, widely used in the chemistry of natural products, organic synthesis and transformations. In this work we study of the theoretical foundations of infrared spectroscopy, the different vibration modes, experimental techniques, and the identification and characterization of solids. Were studied as applications: their use in thermograph and remote sensing satellites

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a fast method for the determination of the total sugar levels in samples of raw coffee was developed using the near infrared spectroscopy technique and multivariate regression. The sugar levels were initially obtained using gravimety as the reference method. Later on, the regression models were built from the near infrared spectra of the coffee samples. The original spectra were pre-treated according to the Kubelka-Munk transformation and multiplicative signal correction. The proposed analytical method made possible the direct determination of the total sugar levels in the samples with an error lower by 8% with respect to the conventional methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical chemical sensors with detection in the near and mid infrared region are reviewed. Fundamental concepts of infrared spectroscopy and optical chemical sensors are briefly described, before presenting some aspects on optical chemical sensors, such as synthesis of NIR and IR reagents, preparation of new materials as well as application in determinations of species of biological, industrial and environmental importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This manuscript aims to show the basic concepts and practical application of Principal Component Analysis (PCA) as a tutorial, using Matlab or Octave computing environment for beginners, undergraduate and graduate students. As a practical example it is shown the exploratory analysis of edible vegetable oils by mid infrared spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the use of Raman and infrared techniques for the qualitative and quantitative analysis of plasticizers in polyvinylchloride (PVC) commercial films. FT-Raman marker bands were indentified for di-2-ethyl-hexyl adipate (DEHA) and di-2-ethyl-hexyl phthalate (DEHP), allowing for the rapid identification of these species in the commercial film. Quantitative analysis by FT-IR resulted in plasticizers concentrations ranging from 11 to 27% (w/w). Considering the little sample preparation and the low cost of the techniques, FT-IR and FT-Raman are viable techniques for a first assessment of plasticizers in commercial samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As imagens térmicas são uma forma simples de identificar diferenças de temperatura em circuitos de sistemas trifásicos, comparando com a sua operação em condições normais. Inspecionando o gradiente térmico das três fases juntas, podemos rapidamente detetar anomalias, numa das fases, devido a desequilíbrios ou sobrecargas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A civilização contemporânea, pelas suas características, é muito exigente em tudo o que diz respeito ao conforto dos edifícios, para trabalho ou habitação, e à necessidade de economizar e racionalizar o uso de energia. A térmica dos edifícios assume, por isso, uma importância acrescida na atividade profissional e no ensino. Para se conduzir ao aperfeiçoamento de soluções na envolvente dos edifícios a este nível, o trabalho aqui realizado centrou-se no estudo do funcionamento da termografia de infravermelhos e da importância da sua utilização na inspeção térmica de edifícios. Descoberta no início do século XIX e desenvolvendo os primeiros sistemas operativos desde a 1ª Guerra Mundial, a fim de determinar heterogeneidades de temperatura superficial, esta técnica não destrutiva permite identificar anomalias que não são visualizadas a olho nu. Com a análise dessas variações de temperatura é possível conhecer os problemas e a localização de irregularidades. Este trabalho baseia-se substancialmente no estudo de edifícios. A análise realizada teve como finalidade executar inspeções termográficas – visuais, com duas abordagens. Por um lado, avaliar salas pertencentes a estabelecimentos de ensino secundário, reabilitadas e não reabilitadas, todas construídas entre as décadas de 60 e 90, com o intuito de diagnosticar patologias construtivas, recorrendo à termografia. Por outro, a análise de edifícios de habitação, com a intenção de avaliar a necessidade de um equipamento complementar às inspeções termográficas – o sistema de porta ventiladora. As inspeções foram regidas pelas diretrizes da norma europeia EN 13187. A termografia é uma técnica importante na realização de ensaios in situ que requerem rapidez de execução, aliada à vantagem de disponibilizar resultados em tempo real, permitindo assim uma primeira análise das leituras no local. A inspeção termográfica complementada com o sistema de porta ventiladora permitiu, também, revelar a importância da necessidade de meios auxiliares em certos casos. A conjugação destas diferentes técnicas permite reduzir a subjetividade da análise in situ e aumentar a fiabilidade do diagnóstico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissertação apresentada tem como objetivo primordial testar e validar as potencialidades da termografia na obtenção de dados para reduzir as perdas ou ganhos térmicos em equipamentos e processos, tornando-os mais eficientes. Realizada em estágio curricular, em ambiente empresarial, na empresa Ecoinside, tem como caso de estudo principal uma indústria de tratamento de alumínios. O processo e os equipamentos escolhidos para o estudo foram estudados e compreendidos. Nas imperfeições detetadas foram apontadas medidas corretivas simples e de fácil execução. Mostrou-se, ainda, algumas das poupanças energéticas concedidas por essas retificações. As capacidades da termografia foram testadas noutros ambientes, que não o industrial, pois um dos objectivos era perceber se a câmara termográfica é uma mais-valia a fornecer dados na realização de uma qualquer auditoria energética, confirmando-se que sim. Dá-se, ainda, a conhecer os princípios por detrás da termografia e um pouco da sua história. Ainda no passado, percebem-se as razões do surgimento das auditorias energéticas antes da presente preocupação ambiental e da eficiência energética.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Civil - Perfil Construção