942 resultados para TORSION UNITS
Resumo:
Using the Luthar-Passi method, we investigate the classical Zassenhaus conjecture for the normalized unit group of the integral group ring of the Suzuki sporadic simple group Suz. As a consequence, for this group we confirm the Kimmerle`s conjecture on prime graphs.
Resumo:
Analogous to *-identities in rings with involution we define *-identities in groups. Suppose that G is a torsion group with involution * and that F is an infinite field with char F not equal 2. Extend * linearly to FG. We prove that the unit group U of FG satisfies a *-identity if and only if the symmetric elements U(+) satisfy a group identity.
Resumo:
Let F be an infinite field of characteristic different from 2, G a group and * an involution of G extended by linearity to an involution of the group algebra FG. Here we completely characterize the torsion groups G for which the *-symmetric units of FG satisfy a group identity. When * is the classical involution induced from g -> g(-1), g is an element of G, this result was obtained in [ A. Giambruno, S. K. Sehgal, A. Valenti, Symmetric units and group identities, Manuscripta Math. 96 (1998) 443-461]. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
OBJECTIVE: To determine stiffness and load-displacement curves as a biomechanical response to applied torsion and shear forces in cadaveric canine lumbar and lumbosacral specimens. STUDY DESIGN: Biomechanical study. ANIMALS: Caudal lumbar and lumbosacral functional spine units (FSU) of nonchondrodystrophic large-breed dogs (n=31) with radiographically normal spines. METHODS: FSU from dogs without musculoskeletal disease were tested in torsion in a custom-built spine loading simulator with 6 degrees of freedom, which uses orthogonally mounted electric motors to apply pure axial rotation. For shear tests, specimens were mounted to a custom-made shear-testing device, driven by a servo hydraulic testing machine. Load-displacement curves were recorded for torsion and shear. RESULTS: Left and right torsion stiffness was not different within each FSU level; however, torsional stiffness of L7-S1 was significantly smaller compared with lumbar FSU (L4-5-L6-7). Ventral/dorsal stiffness was significantly different from lateral stiffness within an individual FSU level for L5-6, L6-7, and L7-S1 but not for L4-5. When the data from 4 tested shear directions from the same specimen were pooled, level L5-6 was significantly stiffer than L7-S1. CONCLUSIONS: Increased range of motion of the lumbosacral joint is reflected by an overall decreased shear and rotational stiffness at the lumbosacral FSU. CLINICAL RELEVANCE: Data from dogs with disc degeneration have to be collected, analyzed, and compared with results from our chondrodystrophic large-breed dogs with radiographically normal spines.
Resumo:
The behavior of the hydroxyl units of synthetic goethite and its dehydroxylated product hematite was characterized using a combination of Fourier transform infrared (FTIR) spectroscopy and X-ray diffraction (XRD) during the thermal transformation over a temperature range of 180-270 degrees C. Hematite was detected at temperatures above 200 degrees C by XRD while goethite was not observed above 230 degrees C. Five intense OH vibrations at 3212-3194, 1687-1674, 1643-1640, 888-884 and 800-798 cm(-1), and a H2O vibration at 3450-3445 cm(-1) were observed for goethite. The intensity of hydroxyl stretching and bending vibrations decreased with the extent of dehydroxylation of goethite. Infrared absorption bands clearly show the phase transformation between goethite and hematite: in particular. the migration of excess hydroxyl units from goethite to hematite. Two bands at 536-533 and 454-452 cm(-1) are the low wavenumber vibrations of Fe-O in the hematite structure. Band component analysis data of FTIR spectra support the fact that the hydroxyl units mainly affect the a plane in goethite and the equivalent c plane in hematite.
Resumo:
Communities of practice (CoPs) may be defined as groups of people who are mutually bound by what they do together (Wenger, 1998, p. 2), that is, they “form to share what they know, to learn from one another regarding some aspects of their work and to provide a social context for that work” (Nickols, 2000, para. 1). They are “emergent” in that the shape and membership emerges in the process of activity (Lees, 2005, p. 7). People in CoPs share their knowledge and experiences freely with the purpose of finding inventive ways to approach new problems (Wenger & Snyder, 2000, p. 2). They can be seen as “shared histories of learning” (Wenger, 1998, p. 86). For some time, QUT staff have been involved in a number of initiatives aimed at sharing ideas and resources for teaching first year students such as the Coordinators of Large First Year Units Working Party. To harness these initiatives and maximise their influence, the leaders of the Transitions In Project (TIP)1 decided to form a CoP around the design, assessment and management of large first year units.
Resumo:
The composition of many professional services firms in the Urban Development area has moved away from a discipline specific ‘silo’ structure to a more multidisciplinary environment. The benefits of multidisciplinarity have been seen in industry by providing synergies across many of the related disciplines. Similarly, the Queensland University of Technology, Bachelor of Urban Development degree has sought to broaden the knowledge base of students and achieve a greater level of synergy between related urban development disciplines through the introduction of generic and multidisciplinary units. This study aims to evaluate the effectiveness of delivering core property units in a multidisciplinary context. A comparative analysis has been undertaken between core property units and more generic units offered in a multidisciplinary context from introductory, intermediate and advanced years within the property program. This analysis was based on data collected from course performance surveys, student performance results, a student focus group and was informed by a reflective process from the student perspective and lecturer/ tutor feedback. The study showed that there are many benefits associated with multidisciplinary unit offerings across the QUT Urban Development program particularly in the more generic units. However, these units require a greater degree of management. It is more difficult to organise, teach and coordinate multidisciplinary student cohorts due to a difference in prior knowledge and experience between each of the discipline groups. In addition, the interaction between lecturers/ tutors and the students frequently becomes more limited. A perception exists within the student body that this more limited face to face contact with academic staff is not valuable which may be exacerbated by the quality of complimentary online teaching materials. For many academics, non-attendance at lectures was coupled with an increase in email communication. From the limited data collected during the study there appears to be no clear correlation between large multidisciplinary student classes and student academic performance or satisfaction.
Resumo:
The ICU is an integral part of any hospital and is under great load from patient arrivals as well as resource limitations. Scheduling of patients in the ICU is complicated by the two general types; elective surgery and emergency arrivals. This complicated situation is handled by creating a tentative initial schedule and then reacting to uncertain arrivals as they occur. For most hospitals there is little or no flexibility in the number of beds that are available for use now or in the future. We propose an integer programming model to handle a parallel machine reacting system for scheduled and unscheduled arrivals.
Resumo:
This paper presents a high voltage pulsed power system based on low voltage switch-capacitor units connected to a current source for several applications such as plasma systems. A buck-boost converter topology is used to utilize the current source and a series of low voltage switch-capacitor units is connected to the current source in order to provide high voltage with high voltage stress (dv/dt) as demanded by loads. This pulsed power converter is flexible in terms of energy control, in that the stored energy in the current source can be adjusted by changing the current magnitude to significantly improve the efficiency of various systems with different requirements. Output voltage magnitude and stress (dv/dt) can be controlled by a proper selection of components and control algorithm to turn on and off switching devices.