271 resultados para TIMS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Few articles deal with lead and strontium isotopic analysis of water samples. The aim of this study was to define the chemical procedures for Pb and Sr isotopic analyses of groundwater samples from an urban sedimentary aquifer. Thirty lead and fourteen strontium isotopic analyses were performed to test different analytical procedures. Pb and Sr isotopic ratios as well as Sr concentration did not vary using different chemical procedures. However, the Pb concentrations were very dependent on the different procedures. Therefore, the choice of the best analytical procedure was based on the Pb results, which indicated a higher reproducibility from samples that had been filtered and acidified before the evaporation, had their residues totally dissolved, and were purified by ion chromatography using the Biorad® column. Our results showed no changes in Pb ratios with the storage time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since 1964, the Center for Geochronological Research - CPGeo, one of the interdepartmental centers of the Instituto de Geociências (IG) of São Paulo University, has developed studies related to several geological processes associated with different rock types. Thermal Ionization Mass Spectrometry Isotopic Dilution (ID-TIMS) has been the technique widely used in the CPGeo U-Pb Laboratory. It provides reliable and accurate results in age determination of superposed events. However, the open-system behavior such as Pb-loss, the inheritance problem and metamictization processes allow and impel us to a much richer understanding of the power and limitations of U-Pb geochronology and thermochronology. In this article, we present the current methodology used at the CPGeo-IGc-USP U-Pb laboratory, the improvements on ID-TIMS method, and report high-precision U-Pb data from zircon, monazite, epidote, titanite, baddeleyite and rutile from different rock types of several domains of the Brazilian south-southeast area, Argentina and Uruguay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Projecte de recerca elaborat a partir d’una estada l’ Osservatorio Vesuviano (Nàpols, Italia) entre novembre del 2006 i març del 2007. Un dels objectius principals de l’estada ha estat conèixer la tècnica analítica Thermal Ionisation Mass Spectrometry (TIMS ) per l’anàlisi d’isòtops radiogènics (Sr i Nd). Aquesta estada ha permès aprendre tant la part de preparació de les mostres, com la part d’utilització i programació de l’instrument. Inicialment en el projecte es va programar l’anàlisi dels isòtops radiogènics en laves i xenòlits de l’illa de Gran Canaria (Illes Canàries) amb l’objectiu de modelar geoquímicament el mantell terrestre sota les illes Canàries. Finalment, i a part de les mostres inicials de Gran Canaria, es van incloure mostres del volcà Vesuvi per tal de concloure un projecte iniciat el 2003 amb el Professor Giovanni Orsi i la Professora Lucia Civetta. L’estudi dels isòtops radiogènics en contextes geodinàmics tant diferents ha permès comparar la variació dels isòtops radiogènics de Sr i Nd que existeix entre volcanisme d’ intraplaca (Illes Canàries) i volcanisme en zones convergents (Vesuvi).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Few articles deal with lead and strontium isotopic analysis of water samples. The aim of this study was to define the chemical procedures for Pb and Sr isotopic analyses of groundwater samples from an urban sedimentary aquifer. Thirty lead and fourteen strontium isotopic analyses were performed to test different analytical procedures. Pb and Sr isotopic ratios as well as Sr concentration did not vary using different chemical procedures. However, the Pb concentrations were very dependent on the different procedures. Therefore, the choice of the best analytical procedure was based on the Pb results, which indicated a higher reproducibility from samples that had been filtered and acidified before the evaporation, had their residues totally dissolved, and were purified by ion chromatography using the Biorad® column. Our results showed no changes in Pb ratios with the storage time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumen basado en el de la publicaci??n

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents static measurements of the Ca isotopic composition of standard reference materials SRM 915 a/b on a Triton Plus™ thermal ionization mass spectrometer with a specially developed Faraday cup array allowing simultaneous measurement of 40Ca and 48Ca. The total amount of Ca in all analyses was kept < 1 µg. With this setup the measurement uncertainties were 0.06 ‰ for 40Ca/44Ca and 0.12 ‰ for 48Ca/40Ca. Measuring all isotopes simultaneously better allows to test the internal consistency of different Ca isotope abundances reported in the literature. The exponential law was observed to correct incompletely instrumental mass fractionation. An improved fractionation correction based on the exponential law is proposed. It changes the 40Ca/44Ca ratio of SRM 915a (corrected relative to 42Ca/44Ca = 0.31221; 48Ca/44Ca = 0.08871) from 47.1635 ± 0.0028 to 47.1649 ± 0.0047. The measurements of SRM 915b were performed with different analytical conditions (runs were prolonged till complete filament load depletion). Even if the 40Ca/44Ca ratio of SRM 915b, when corrected with the simple exponential law, appears different (47.1532 ± 0.0038) from that of SRM 915a, it becomes coincident (47.1613 ± 0.0028) when corrected with a second-order refinement. This supports the use of the improved exponential law to obtain internally consistent Ca isotope ratio for natural samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The isotope composition of selenium (Se) can provide important constraints on biological, geochemical, and cosmochemical processes taking place in different reservoirs on Earth and during planet formation. To provide precise qualitative and quantitative information on these processes, accurate and highly precise isotope data need to be obtained. The currently applied ICP-MS methods for Se isotope measurements are compromised by the necessity to perform a large number of interference corrections. Differences in these correction methods can lead to discrepancies in published Se isotope values of rock standards which are significantly higher than the acclaimed precision. An independent analytical approach applying a double spike (DS) and state-of-the-art TIMS may yield better precision due to its smaller number of interferences and could test the accuracy of data obtained by ICP-MS approaches. This study shows that the precision of Se isotope measurements performed with two different Thermo Scientific™ Triton™ Plus TIMS is distinctly deteriorated by about ±1‰ (2 s.d.) due to δ80/78Se by a memory Se signal of up to several millivolts and additional minor residual mass bias which could not be corrected for with the common isotope fractionation laws. This memory Se has a variable isotope composition with a DS fraction of up to 20% and accumulates with increasing number of measurements. Thus it represents an accumulation of Se from previous Se measurements with a potential addition from a sample or machine blank. Several cleaning techniques of the MS parts were tried to decrease the memory signal, but were not sufficient to perform precise Se isotope analysis. If these serious memory problems can be overcome in the future, the precision and accuracy of Se isotope analysis with TIMS should be significantly better than those of the current ICP-MS approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tang sancai is one of the most important types of Chinese ceramics. To determine the provenance of Tang sancai is important to study ancient trade and other issues. In this paper we compare ICP-MS trace elements and TIMS Sr-Nd isotopes of visibly similar Tang sancai from two major production centres Gongxian and Yaozhou. The variation in contents/ratios of many of > 40 trace elements is small for samples from Gongxian, yet is considerably bigger for that from Yaozhou. However, the variation in Sr-87/Sr-86 and Nd-143/Nd-144 isotopic ratios is very small for samples from both places. Gongxian and Yaozhou samples have distinctive Sr-Nd isotopic and trace element features despite their similarity in major elements, and these analysis data can be interpreted with geochemistry, indicating that Sr and Nd isotopes have great potential in ceramic provenance studies. The distinct characterisation of these samples provides valuable criteria for identifying provenance of Tang sancai of uncertain origin. Two modern fakes are also analysed, and they can as well be distinguished from antique Tang sancai using above criteria. (c) 2005 Published by Elsevier Ltd.