938 resultados para Surgical-correction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eyebrow positions differ in many ways. They vary in shape, thickness, length, and distance between the eyebrows, making the face more or less harmonious. When a large distance exists between the eyebrows and the medial brow is slanting downward, the glabellar area is larger, giving the face an awkward appearance. To correct this deformity, the authors propose using two Z-plasties to allow transposition of flaps in the region of the medial brow. The Z-shaped flap is outlined at the medial third of the brow, in the glabellar region, with the eyebrow centered in the lower portion of the ""Z"" and the hairless skin in the upper portion. The flaps then are transposed and sutured. Transposition of the flaps, lifting the brow flap to the glabellar region, results in horizontal positioning of the medial and central third of the eyebrow. The proposed transpositioning of ""Z"" flaps in this region corrects this type of deformity of the medial and central portions of the eyebrows, with an aesthetically satisfactory result.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The no. 0-14 cleft involves the midline of the face and cranium. It may include both a true and a false median cleft lip, with or without associated hypotelorism or hypertelorism. The no. 0 cleft is the most common of the craniofacial clefts. The objective of this study was to review the functional outcome and aesthetic results of the different techniques applied for each case. We have conducted a retrospective analysis of our series consisting of 32 cases of Tessier no. 0 cleft, in the period between 1997 and 2007. The patients were divided into 2 groups: those with the true median cleft and those with the false median cleft. The clinical findings, lip malformation, alveolar cleft, nasal appearance, septal involvement, associated deformities, and surgical procedures, were all reviewed. Holoprosencephaly was present in 9 cases, with a false median cleft upper lip and an absence of the premaxilla, septum, and columella (only 1 patient underwent lip and columella reconstruction at 2 years of age). Nine patients had an incomplete median cleft lip. Seven of these cases had associated median alveolar cleft, and 1 had an intranasal tumor, associated with lipoma of corpus callosum, characteristic of the Pai syndrome. Six cases of a bifid nose were seen, 2 of which were associated with an alveolar median cleft and hypertelorism. An isolated median alveolar cleft was present in 7 cases, 2 of them associated with a no. 30 cleft. This article presents a large series of Tessier no. 0 cleft, describing the differences between the false and the true median cleft. The surgical procedures may vary in relation to the type of involvement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Individuals with dentofacial deformities have masticatory muscle changes. The objective of the present study was to determine the effect of interdisciplinary treatment in patients with dentofacial deformities regarding electromyographic activity (EMG) of masticatory muscles three years after surgical correction. Thirteen patients with class III dentofacial deformities were studied, considered as group PI (before surgery) and group P3 (3 years to 3 years and 8 months after surgery). Fifteen individuals with no changes in facial morphology or dental occlusion were studied as controls. The participants underwent EMG examination of the temporal and masseter muscles during mastication and biting. Evaluation of the amplitude interval of EMG activity revealed a difference between P1 and P3 and no difference between P3 and the control group. In contrast, evaluation of root mean square revealed that, in general, P3 values were higher only when compared with PI and differed from the control group. There was an improvement in the EMG activity of the masticatory muscles, mainly observed in the masseter muscle, with values close to those of the control group in one of the analyses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To analyse the effect of integrated orthodontic treatment, orthognathic surgery and orofacial myofunctional therapy on masseter muscle thickness in patients with class III dentofacial deformity three years after orthognathic surgery. Design: A longitudinal study was conducted on 13 patients with class III dentofacial deformities, denoted here as group P1 (before surgery) and group P3 (same patients 3 years to 3 years and 8 months after surgery). Fifteen individuals with no changes in facial morphology or dental occlusion were assigned to the control group (CG). Masseter muscle ultrasonography was performed in the resting and biting situations in the three groups. Data were analysed statistically by a mixed-effects linear model considering a level of significance of P < 0.05. Results: Significantly higher values (P < 0.01) of masseter muscle thickness (cm) were detected in group P3 (right rest: 0.82 +/- 0.16, left rest: 0.87 +/- 0.21, right bite: 1 +/- 0.22, left bite: 1.04 +/- 0.28) compared to group P1 (right rest: 0.63 +/- 0.19, left rest: 0.64 +/- 0.15, right bite: 0.87 +/- 0.16, left bite: 0.88 +/- 0.14). Between P3 and CG (right rest: 1.02 +/- 0.19, left rest: 1 +/- 0.19, right bite: 1.18 +/- 0.22, left bite: 1.16 +/- 0.22) there was a significant difference on the right side of the muscle (P < 0.05) in both situations and on the left side at rest. Conclusion: The proposed treatment resulted in improved masseter muscle thickness in patients with class III dentofacial deformity. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pectus carinatum (PC) is a chest deformity caused by a disproportionate growth of the costal cartilages compared to the bony thoracic skeleton, pulling the sternum towards, which leads to its protrusion. There has been a growing interest on using the ‘reversed Nuss’ technique as minimally invasive procedure for PC surgical correction. A corrective bar is introduced between the skin and the thoracic cage and positioned on top of the sternum highest protrusion area for continuous pressure. Then, it is fixed to the ribs and kept implanted for about 2–3 years. The purpose of this work was to (a) assess the stresses distribution on the thoracic cage that arise from the procedure, and (b) investigate the impact of different positioning of the corrective bar along the sternum. The higher stresses were generated on the 4th, 5th and 6th ribs backend, supporting the hypothesis of pectus deformities correction-induced scoliosis. The different bar positioning originated different stresses on the ribs’ backend. The bar position that led to lower stresses generated on the ribs backend was the one that also led to the smallest sternum displacement. However, this may be preferred, as the risk of induced scoliosis is lowered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A previously developed model is used to numerically simulate real clinical cases of the surgical correction of scoliosis. This model consists of one-dimensional finite elements with spatial deformation in which (i) the column is represented by its axis; (ii) the vertebrae are assumed to be rigid; and (iii) the deformability of the column is concentrated in springs that connect the successive rigid elements. The metallic rods used for the surgical correction are modeled by beam elements with linear elastic behavior. To obtain the forces at the connections between the metallic rods and the vertebrae geometrically, non-linear finite element analyses are performed. The tightening sequence determines the magnitude of the forces applied to the patient column, and it is desirable to keep those forces as small as possible. In this study, a Genetic Algorithm optimization is applied to this model in order to determine the sequence that minimizes the corrective forces applied during the surgery. This amounts to find the optimal permutation of integers 1, ... , n, n being the number of vertebrae involved. As such, we are faced with a combinatorial optimization problem isomorph to the Traveling Salesman Problem. The fitness evaluation requires one computing intensive Finite Element Analysis per candidate solution and, thus, a parallel implementation of the Genetic Algorithm is developed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe the case of a 40-day-old female patient with a history of breathlessness since birth who was referred to our hospital for surgical correction of common arterial trunk. The invasive investigation disclosed a Fallot¢s tetralogy anatomy associated with an anomalous origin of the left pulmonary artery from the ascending aorta. Immediately after diagnosis, the patient underwent a successful total surgical correction of the defect, including simultaneous anastomosis of the left pulmonary artery to the pulmonary trunk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate whether left ventricular end-systolic (ESD) diameters £ 51mm in patients (pt) with severe chronic mitral regurgitation (MR) are predictors of a poor prognosis after mitral valve surgery (MVS). METHODS: Eleven pt (aged 36±13 years) were studied in the preoperative period (pre), median of 36 days; in the early postoperative period (post1), median of 9 days; and in the late postoperative period (post2), mean of 38.5±37.6 months. Clinical and echocardiographic data were gathered from each pt with MR and systolic diameter ³51mm (mean = 57±4mm) to evaluate the result of MVS. Ten patients were in NYHA Class III/IV. RESULTS: All but 2 pt improved in functional class. Two pt died from heart failure and infectious endocarditis 14 and 11 months, respectively, after valve replacement. According to ejection fraction (EF) in post2, we identified 2 groups: group 1 (n=6), whose EF decreased in post1, but increased in post2 (p=0.01) and group 2 (n=5), whose EF decreased progressively from post1 to post2 (p=0.10). All pt with symptoms lasting £ 48 months had improvement in EF in post2 (p=0.01). CONCLUSION: ESD ³51mm are not always associated with a poor prognosis after MVS in patients with MR. Symptoms lasting up to 48 months are associated with improvement in left ventricular function.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Abnormal ECG findings suggestive of cardiac disease are frequent in patients with funnel chest, although structural heart disease is rare. Electrocardiographic characteristics and changes following new surgical treatments in young adults are not described so far. The aim of the study was to analyze electrocardiographic characteristics of patients with funnel chest before and after minimally invasive funnel chest correction by the Nuss procedure. METHODS Twenty-six patients with surgical correction of funnel chest using pectus bar were included. Twelve-lead ECGs before and later than one year after surgery were analyzed. RESULTS In postoperative ECGs, amplitude of P wave in lead II and negative terminal amplitude of P wave in lead V1 decreased from 0.13 to 0.10mV (p=0.03), and from 0.10 to 0.04mV (p<0.001), respectively. Mean QRS duration decreased from 108ms to 98ms (p=0.003) after correction. A pathological left and right Sokolow-Lyon index was observed in 35% and 23% of patients before, versus 8% (p=0.04) and 0% (p=0.01) after correction, respectively. In contrast, the rate of patients with J wave pattern in precordial leads V4-V6 increased from 8% before to 42% after surgery (p=0.004). CONCLUSIONS ECG abnormalities in patients with funnel chest are frequent, and can normalize after surgical correction by the Nuss procedure. De novo J wave pattern in precordial leads V4-V6 is a frequent finding after surgical funnel chest correction using pectus bar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High levels of corneal astigmatism are prevalent in a significant proportion of the population. During cataract surgery pre-existing astigmatism can be corrected using single or paired incisions on the steep axis of the cornea, using relaxing incisions or with the use of a toric intraocular lens. This review provides an overview of the conventional methods of astigmatic correction during cataract surgery and in particular, discusses the various types of toric lenses presently available and the techniques used in determining the correct axis for the placement of such lenses. Furthermore, the potential causes of rotation in toric lenses are identified, along with techniques for assessing and quantifying the amount of rotation and subsequent management options for addressing post-operative rotation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Presbyopia is an age-related eye condition where one of the signs is the reduction in the amplitude of accommodation, resulting in the loss of ability to change the eye's focus from far to near. It is the most common age-related ailments affecting everyone around their mid-40s. Methods for the correction of presbyopia include contact lens and spectacle options but the surgical correction of presbyopia still remains a significant challenge for refractive surgeons. Surgical strategies for dealing with presbyopia may be extraocular (corneal or scleral) or intraocular (removal and replacement of the crystalline lens or some type of treatment on the crystalline lens itself). There are however a number of limitations and considerations that have limited the widespread acceptance of surgical correction of presbyopia. Each surgical strategy presents its own unique set of advantages and disadvantages. For example, lens removal and replacement with an intraocular lens may not be preferable in a young patient with presbyopia without a refractive error. Similarly treatment on the crystalline lens may not be a suitable choice for a patient with early signs of cataract. This article is a review of the options available and those that are in development stages and are likely to be available in the near future for the surgical correction of presbyopia.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. A minimally invasive surgical correction is commonly carried out to remodel the anterior chest wall by using an intrathoracic convex prosthesis in the substernal position. The process of prosthesis modeling and bending still remains an area of improvement. The authors developed a new system, i3DExcavatum, which can automatically model and bend the bar preoperatively based on a thoracic CT scan. This article presents a comparison between automatic and manual bending. The i3DExcavatum was used to personalize prostheses for 41 patients who underwent pectus excavatum surgical correction between 2007 and 2012. Regarding the anatomical variations, the soft-tissue thicknesses external to the ribs show that both symmetric and asymmetric patients always have asymmetric variations, by comparing the patients’ sides. It highlighted that the prosthesis bar should be modeled according to each patient’s rib positions and dimensions. The average differences between the skin and costal line curvature lengths were 84 ± 4 mm and 96 ± 11 mm, for male and female patients, respectively. On the other hand, the i3DExcavatum ensured a smooth curvature of the surgical prosthesis and was capable of predicting and simulating a virtual shape and size of the bar for asymmetric and symmetric patients. In conclusion, the i3DExcavatum allows preoperative personalization according to the thoracic morphology of each patient. It reduces surgery time and minimizes the margin error introduced by the manually bent bar, which only uses a template that copies the chest wall curvature.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pectus excavatum is the most common congenital deformity of the anterior thoracic wall. The surgical correction of such deformity, using Nuss procedure, consists in the placement of a personalized convex prosthesis into sub-sternal position to correct the deformity. The aim of this work is the CT-scan substitution by ultrasound imaging for the pre-operative diagnosis and pre-modeling of the prosthesis, in order to avoid patient radiation exposure. To accomplish this, ultrasound images are acquired along an axial plane, followed by a rigid registration method to obtain the spatial transformation between subsequent images. These images are overlapped to reconstruct an axial plane equivalent to a CT-slice. A phantom was used to conduct preliminary experiments and the achieved results were compared with the corresponding CT-data, showing that the proposed methodology can be capable to create a valid approximation of the anterior thoracic wall, which can be used to model/bend the prosthesis