995 resultados para Surface Contamination


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resuspended soil and other airborne particles adhered to the leaf surface affect the chemical composition of the plant. A well-defined cleaning procedure is necessary to avoid this problem, providing a correct assessment of the inherent chemical composition of bromeliads. To evaluate the influence of a washing procedure, INAA was applied for determining chemical elements in the leaves of bromeliads from Vriesea carinata species, both non-washed and washed with Alconox, EDTA and bi-distilled water. Br, Ce, Hg, La, Sc, Se, Sm and Th showed higher mass fractions in non-washed leaves. The washing procedure removed the exogenous material without leaching chemical elements from inside the tissues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present investigation was to gain an understanding of the nature of the carbon contamination on the surface of standard steel transmission electron spectroscopy (TEM) specimens, the effect of exposure of a clean specimen to normal laboratory air, and the efficacy of plasma-cleaning treatments. This knowledge is a necessary prerequisite to the development of appropriate specimen preparation and/or specimen cleaning methods. X-ray photoelectron spectroscopy in combination with argon ion beam profiling was used to characterize the specimen surfaces of X65 steel and 316 stainless steel. The only clean carbon-free surface obtained was that during argon etching of the sample in the surface analysis chamber. Any exposure of a previously cleaned sample to laboratory air resulted in a rapid carbon (hydrocarbon) contamination of the sample surface and the development of surface oxidation, Plasma cleaning with subsequent exposure of the specimen to the laboratory air also resulted in a carbon-contaminated surface. This suggests that procedures of preparation of TEM specimens of steels outside an ultrahigh vacuum chamber are unlikely to result in the lowering of contamination rates on specimens to levels where measurements for carbon in the grain boundaries are possible. What is needed is a cleaning system as an integral part of the specimen insertion system into the field-emission scanning transmission electron microscope. This cleaning could be carried out by argon ion etching. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Switzerland, individuals exposed to the risk of activity intake are required to perform regular monitoring. Monitoring consists in a screening measurement and is meant to be performed using commonly available laboratory instruments. More particularly, iodine intake is measured using a surface contamination monitor. The goal of the present paper is to report the calibration method developed for thyroid screening instruments. It consists of measuring the instrument response to a known activity located in the thyroid gland of a standard neck phantom. One issue of this procedure remains that the iodine radioisotopes have a short half-life. Therefore, the adequacy and limitations to simulate the short-lived radionuclides with so-called mock radionuclides of longer half-life were also evaluated. In light of the results, it has been decided to use only the appropriate iodine sources to perform the calibration.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Filamentous fungi from genus Aspergillus were previously detected in wastewater treatment plants (WWTP) as being Aspergillus flavus (A. flavus), an important toxigenic fungus producing aflatoxins. This study aimed to determine occupational exposure adverse effects due to fungal contamination produced by A. flavus complex in two Portuguese WWTP using conventional and molecular methodologies. Air samples from two WWTP were collected at 1 m height through impaction method. Surface samples were collected by swabbing surfaces of the same indoor sites. After counting A. flavus and identification, detection of aflatoxin production was ensured through inoculation of seven inoculates in coconut-milk agar. Plates were examined under long-wave ultraviolet (UV; 365 nm) illumination to search for the presence of fluorescence in the growing colonies. To apply molecular methods, air samples were also collected using the impinger method. Samples were collected and collection liquid was subsequently used for DNA extraction. Molecular identification of A. flavus was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR detection system (Corbett). Among the Aspergillus genus, the species that were more abundant in air samples from both WWTP were Aspergillus versicolor (38%), Aspergillus candidus (29.1%), and Aspergillus sydowii (12.7%). However, the most commonly species found on surfaces were A. flavus (47.3%), Aspergillus fumigatus (34.4%), and Aspergillus sydowii (10.8%). Aspergillus flavus isolates that were inoculated in coconut agar medium were not identified as toxigenic strains and were not detected by RT-PCR in any of the analyzed samples from both plants. Data in this study indicate the need for monitoring fungal contamination in this setting. Although toxigenic strains were not detected from A. flavus complex, one cannot disregard the eventual presence and potential toxicity of aflatoxins.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Despite the classification as known or suspected human carcinogens, by the International Agency for Research on Cancer, the antineoplastic drugs are extensively used in cancer treatment due to their specificity and efficacy. As human carcinogens, these drugs represent a serious threat to the healthcare workers involved in their preparation and administration. This work aims to contribute to better characterize the occupational exposure of healthcare professionals to antineoplastic drugs, by assessing workplace surfaces contamination of pharmacy and administration units of two Portuguese hospitals. Surface contamination was assessed by the determination of cyclophosphamide, 5-fluorouracil, and paclitaxel. These three drugs were used as surrogate markers for surfaces contamination by cytotoxic drugs. Wipe samples were taken and analyzed by HPLCDAD. From the total of 327 analyzed samples, in 121 (37%) was possible to detect and quantify at least one drug. Additionally, 28 samples (8.6 %) indicate contamination by more than one antineoplastic drug, mainly in the administration unit, in both hospitals. Considering the findings in both hospitals, specific measures should be taken, particularly those related with the promotion of good practices and safety procedures and also routine monitoring of surfaces contamination in order to guarantee the appliance of safety measures.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objectives of this research were (1) to study the effect of contact pressure, compression time, and liquid (moisture content of the fabric) on the transfer by sliding contact of non-fixed surface contamination to protective clothing constructed from uncoated, woven fabrics, (2) to study the effect of contact pressure, compression time, and liquid content on the subsequent penetration through the fabric, and (3) to determine if varying the type of contaminant changes the effect of contact pressure, compression time, and liquid content on the transfer by sliding contact and penetration of non-fixed surface contamination. ^ It was found that the combined influence of the liquid (moisture content of the fabric), load (contact pressure), compression time, and their interactions significantly influenced the penetration of all three test agents, sucrose- 14C, triolein-3H, and starch-14C through 100% cotton fabric. The combined influence of the statistically significant main effects and their interactions increased the penetration of triolein- 3H by 32,548%, sucrose-14C by 7,006%, and starch- 14C by 1,900%. ^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A new surface analysis technique has been developed which has a number of benefits compared to conventional Low Energy Ion Scattering Spectrometry (LEISS). A major potential advantage arising from the absence of charge exchange complications is the possibility of quantification. The instrumentation that has been developed also offers the possibility of unique studies concerning the interaction between low energy ions and atoms and solid surfaces. From these studies it may also be possible, in principle, to generate sensitivity factors to quantify LEISS data. The instrumentation, which is referred to as a Time-of-Flight Fast Atom Scattering Spectrometer has been developed to investigate these conjecture in practice. The development, involved a number of modifications to an existing instrument, and allowed samples to be bombarded with a monoenergetic pulsed beam of either atoms or ions, and provided the capability to analyse the spectra of scattered atoms and ions separately. Further to this a system was designed and constructed to allow incident, exit and azimuthal angles of the particle beam to be varied independently. The key development was that of a pulsed, and mass filtered atom source; which was developed by a cyclic process of design, modelling and experimentation. Although it was possible to demonstrate the unique capabilities of the instrument, problems relating to surface contamination prevented the measurement of the neutralisation probabilities. However, these problems appear to be technical rather than scientific in nature, and could be readily resolved given the appropriate resources. Experimental spectra obtained from a number of samples demonstrate some fundamental differences between the scattered ion and neutral spectra. For practical non-ordered surfaces the ToF spectra are more complex than their LEISS counterparts. This is particularly true for helium scattering where it appears, in the absence of detailed computer simulation, that quantitative analysis is limited to ordered surfaces. Despite this limitation the ToFFASS instrument opens the way for quantitative analysis of the 'true' surface region to a wider range of surface materials.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Healthcare associated infections may arise from many sources, including patient?s own skin flora and the clinical environment, and inflict a significant burden within the health service. Adequate and effective skin antisepsis and surface disinfection are therefore essential factors in infection control. Current EPIC guidelines recommend 2 % chlorhexidine (CHG) in 70 % isopropyl alcohol (IPA) for skin antisepsis however poor penetration has been reported. Eucalyptus oil (EO) is a known permeation enhancer, producing synergistic antimicrobial activity when combined with CHG. In this current study, the antimicrobial efficacy of EO and its main constituent 1,8-cineole were assessed against a panel of clinically relevant microorganisms, alone and in combination with CHG. The superior antimicrobial efficacy of EO compared with 1,8-cineole, and synergistic effects with CHG against planktonic and biofilm cultures, confirmed its suitability for use in subsequent studies within this thesis. Impregnation of EO, CHG and IPA onto prototype hard surface disinfectant wipes demonstrated significantly improved efficacy compared with CHG/IPA wipes, with clear reductions in the time required to eliminate biofilms. Optimisation of the EO/CHG/IPA formulation resulted in the development of Euclean® wipes, with simulated-use and time kill studies confirming their ability to remove microbial surface contamination, prevent cross contamination and eliminate biofilms within 10 minutes. The employment of isothermal calorimetry provided additional information on the type and rate of antimicrobial activity possessed by Euclean® wipes. A clinical audit of the Euclean® wipes at Birmingham Children?s Hospital, Birmingham, U.K. revealed divided staff opinion, with the highest cited advantage and disadvantage concerning the odour. Finally, skin penetration and cell toxicity studies of EO/CHG biopatches and Euclean® solution developed during this study, revealed no permeation into human skin following biopatch application, and no significant toxicity. These current studies enhance the knowledge regarding EO and its potential applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237°C, 75%/287°C, Castorit Super C (CS)-100%/70°C, 75%/141°C and Rematitan Plus (RP)- 100%/430°C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (α = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (α = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 μm (204.03 VHN). The group CS 75%/141°C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 μm. The castings made with CS - 100%/70°C presented the lowest levels of marginal misfit, followed by RE -100%/237°C. The conventional investments CS (100%) and RE (100%) showed better marginal fit than RP, but the CS (75%) had higher surface contamination.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The extensive use of antineoplastic agents in chemotherapy may be at risk to health care workers involved in the preparation and administration of these drugs. In this study cyclophosphamide, a drug classified as a human carcinogen, was quantified by adapting a previous analytical method using gas chromatography coupled to mass spectrometry (GC-MS) after solid phase extraction with diatomaceous earth. The drug was measured by analysis in surfaces (wipe samples) and gloves, collected from four different hospitals, before and after the practice of cleaning procedures, and the use of a closed-system device for the preparation and administration. Validation results were satisfactory and cyclophosphamide levels ranging from below the quantification limit to 141000 ng. Our findings demonstrated that surfaces and materials contamination was found in all hospitals during the traditional open technique for preparation and administration of cyclophosphamide and a significant reduction in contamination when a closed-system device was used. However, some values were considered unexpected, especially those obtained from samples collected after the cleaning surfaces.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purposes: To evaluate the dosimetric effect of outpatient radioiodine therapy for thyroid cancer in members of a patient`s family and their living environment, when using iodine-131 doses reaching 7.4 GBq. The following parameters were thus defined: (a) whole-body radiation doses to caregivers, (b) the production of contaminated solid waste, and (c) radiation potential and surface contamination within patients` living quarters. Methods: In total, 100 patients were treated on an outpatient basis, taking into consideration their acceptable living conditions, interests, and willingness to comply with medical and radiation safety guidelines. Both the caregivers and the radiation dose potentiality inside patients` residences were monitored by using thermoluminescent dosimeters. Surface contamination and contaminated solid wastes were identified and measured with a Geiger-Muller detector. Results: A total of 90 monitored individuals received a mean dose of 0.27 (+/- 0.28) mSv, and the maximum dose registered was 1.6 mSv. The mean value for the potential dose within all living quarters was 0.31(+/- 0.34) mSv, and the mean value per monitored surface was 5.58 Bq/cm(2) for all the 1659 points measured. The overall production of contaminated solid wastes was at a low level, being about 3 times less than the exemption level indicated by the International Atomic Energy Agency. Conclusions: This study indicates that the treatment of thyroid cancer by applying radioiodine activities up to 7.4 GBq, on an outpatient basis, is a safe procedure, especially when supervised by qualified professionals. This alternative therapy should be a topic for careful discussion considering the high potential for reducing costs in healthcare and improving patient acceptance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives The first objective of this study was to evaluate the radiological impact on relatives and the environment because of outpatient treatment of differentiated thyroid carcinoma with 3.7 and 5.55 GBq of ((131)I)NaI. The second objective was to determine, analyze, and evaluate whole-body radiation dose to caregivers, the production of contaminated solid waste, and the potentiality of radiation dose and surface contamination existing inside patients` households. Methods Twenty patients were treated on an outpatient basis, taking into consideration their acceptable living conditions, interests, and willingness to comply with medical and radiation-safety guidelines. The caregivers themselves, as well as the potentiality of the radiation dose inside patients` residences, were monitored with a thermo-luminescence dosimeter. Surface contamination and contaminated solid wastes were identified and measured by using a Geiger-Muller detector. Results and discussion Twenty-six monitored individuals received accumulated effective radiation doses of less than 1.0 mSv, and only one 2.8 mSv, throughout the 7 days of measurement. The maximum registered value for the potential of radiation dose inside all living areas was 1.30 mSv. The monitored surface contamination inside patients` dwellings showed a mean value of 4.2 Bq/cm(2) for all surfaces found to be contaminated. A total of 2.5l of contaminated solid waste was generated by the patients with 3.33 MBq of all estimated activity. Conclusion This study revealed that the treatment of differentiated thyroid carcinoma with 3.7 and 5.55 GBq of ((131)I)NaI, on an outpatient basis, can be safe when overseen by qualified professionals and with an adapted radiation-protection guideline. Even considering the radioiodine activity level and the dosimetric methodology applied here, negligible human exposure and a nonmeasurable radiological impact to the human environment were found. Nucl Med Commun 30:533-541 (C) 2009 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thermally unaltered conodont elements, brachiopods. and vertebrates were analyzed with reverse phase high profile liquid chromatography to locate and quantify amino acid remnants of the original organic matrix in the fossils. No consistent similarities in amino acid content were found in conodont taxa. and criteria based on organic residues appear to have no taxonomic significance in the fossils tested from these localities. However, hydroxyproline. an amino acid that is found in the collagen molecules of animals. as well as in the glycoproteins in the cell walls and reproductive tissues of certain plants, is represented in most taxa. The organic matter retained in the impermeable crowns of conodont elements might have been derived originally from a form of collagen. Biochemical analyses. correlated with histochemical tests, demonstrate that organic matter is an integral part of the hyaline tissue of the element crown and not the result of surface contamination. Tests of a range of vertebrate and invertebrate fossil hard tissues produced similar results. The analyses indicate that hyaline tissue in the conodont element crown is not a form of vertebrate enamel. which contains no collagen. Albid tissue. with little or no organic content. is not a form of vertebrate bone or dentine, both based on collagen and low in mineral. Although these results do not help to determine the phylogenetic affinities of conodont animals, they indicate teat conodont elements do not contain hard tissues characteristic of vertebrate animals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução – No caso de uma eventual contaminação radioativa esta deve ser quantificada, pelo que é necessário garantir que as condições de funcionamento de um monitor de contaminação de superfícies se encontrem adequadamente caracterizadas, através da determinação da sua eficiência de deteção. Este estudo tem como objetivo determinar a eficiência de deteção de um monitor de contaminação e analisar a influência da distância e da atividade. Metodologia – O monitor de contaminação Thermo Mini 900E e as fontes radioativas planas de referência de Carbono – 14 (C-14), Césio – 137 (Cs-137), Estrôncio – 90 (Sr-90), Cloro – 36 (Cl-36) e Amerício – 241 (Am-241) com débito de emissão superficial rastreável ao Physikalish Technischen Bundesanstalt (PTB) foram utilizadas. Fontes de Sr-90 e C-14 com dois débitos de emissão distintos para cada e distâncias de 1 a 20mm foram usados para estudar a sua influência na eficiência de deteção. Resultados – Verificou-se que as fontes radioativas emissoras de partículas de maior energia apresentam uma maior eficiência de deteção e que esta diminui com o aumento da distância do detetor à fonte, sendo que os radioisótopos de maior energia apresentam um decréscimo na eficiência de 15% ao longo de 20mm, enquanto os radioisótopos de menor energia apresentam um decréscimo de 10%. Não se verificou uma influência expressiva do débito de emissão na eficiência de deteção deste monitor de contaminação. Conclusão – A eficiência de deteção de um monitor de contaminação portátil é dependente da distância deste à contaminação bem como do tipo de radiação emitida e energia dos radioisótopos presentes na contaminação. - ABSTRACT - Introduction – A radioactive contamination needs to be quantified in case it eventually occurs. Therefore it is necessary to ensure that the operating conditions of a surface contamination monitor are characterized by determining its detection efficiency. This experimental study aims to determine the detection efficiency of a contamination monitor and evaluate the distance and surface emission rate influence on the detection efficiency. Methodology – A contamination monitor Thermo Mini 900E was tested with reference radiation sources of Carbon – 14 (C-14), Cesium – 137 (Cs-137), Strontium – 90 (Sr-90), Chlorine – 36 (Cl-36) and Americium – 241 (Am-241) with its emission rate traced to the Physikalish Technischen Bundesanstalt (PTB). Sources of Sr-90 and C-14 with two different emission rates for each one and distances of 1 to 20mm were used to study its influence in the detection efficiency. Results – With the increasing of distance, the detection efficiency decreases. The most energetic radiation sources have higher detection efficiency, boasting a 15% decrease over 20mm whereas the sources bearing a smaller efficiency decrease 10%. No influence of the surface emission rate in the detection efficiency was verified. Conclusion – Thus, it is concluded that the detection efficiency of a contamination monitor is dependent of the distance between it and the contamination as well as the type and energy of the radioisotopes present in the contamination.