1000 resultados para Styloid process


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Association between the presence of an elongated styloid process, vascular calcification (atheroma) and the potential risk factor for osteoporosis was studied. Presence of an elongated styloid process was found to be correlated with systemic osteoporosis and also between elongated styloid process and atheroma. The association between the presences of an elongated styloid process and vascular calcification (atheroma) with the potential risk factor assessment for osteoporosis was studied. Bone mineral density obtained by dual energy X-ray absorptiometry diagnosed osteopenia/osteoporosis on at least two of three sites (column, hips, and forearm) of 50 female patients. Panoramic maxillomandibular radiographs were taken and analyzed. Elongation of the styloid processes was measured and the presence of atheromas in the carotid was investigated. Eighty percent of the patients presented at least one side with elongated styloid process and the highest prevalence (87.5%) occurred in individuals between 60 and 69 years. Atheroma was found in four patients, three of which presented elongated styloid on at least one side and had diagnosed osteoporosis on at least two of the evaluated sites. Correlation was found between the elongation of the styloid process and systemic osteoporosis, and between elongated styloid process and atheroma. The method in this study might be used as part of a method for osteopenia/osteoporosis and atheroma risk assessment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

70 human temporal bones were analyzed with the aid of an otologic microscope. The styloid prominence was found to be extremely variable in shape, location and occurrence. Depending on the degree of development, the prominence establishes important relationships with the sinus tympani, with the fossula of the cochlear fenestra, and with the suprapyramidal recess. Serial sections were used to study the relationship of the styloid process with the facial nerve inside the bony mass of the mastoid portion of the temporal bone.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Styloid syndrome is characterized by an elongated styloid process or calcification of the stylomandibular and stylohyoid ligament. This study describes a case of a 65-year-old woman who presented to the Stomatology Clinic, University of Marilia with temporomandibular joint pain, ear ringing and a reduced ability to open the mouth. Panoramic and posteroanterior digital radiographs showed bilateral elongation of the styloid processes, especially of the right side, whose length extended beyond the mandible angle. The diagnosis was confirmed with the association of clinical data and image examinations. The treatment options for styloid Syndrome include clinical follow-up, surgical removal of the styloid process or fracture of the elongated process. The case was managed by providing prosthetic rehabilitation and clinical follow-up, observing the level of discomfort and the benefit that could be achieved by the therapy, and avoiding surgical intervention.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The objective of our study was to report the MRI findings in dorsal fractures of the triquetrum, with an emphasis on dorsal carpal ligament injuries. MATERIALS AND METHODS: A total of 21 patients (16 men, five women; mean age, 41.9 years) with acute or subacute (≤ 6 weeks) dorsal triquetral fractures on radiography and MRI were included in this two-center retrospective study. MRI of the wrist was performed on 3-T units with transverse T1-weighted, coronal or transverse (or both) fat-suppressed T2weighted, transverse gadolinium-enhanced fat-suppressed T1-weighted turbo spin-echo, and 3D gadolinium-enhanced fat-suppressed T1-weighted gradient-recalled echo sequences. Three musculoskeletal radiologists evaluated the ulnar styloid process index (USPI) on radiographs and the following MRI features: fracture pattern (types 1-6), bone fragment size and displacement, bone marrow edema distribution, and dorsal carpal ligament tears. RESULTS: Eight type 1, one type 2, six type 3, five type 4, and one type 5 fractures were identified. These fractures were associated with 14 (66.7%), 17 (81.0%), and 16 (76.2%) tears of the dorsal radiocarpal, ulnotriquetral, and intercarpal ligaments, respectively. There was no correlation between bone marrow edema distribution and dorsal carpal ligament injuries (all p > 0.05). The mean (± SD) bone fragment volume and displacement were 205 ± 157 mm(3) and 1.0 ± 1.1 mm, respectively. The mean USPI was 0.21 ± 0.10. CONCLUSION: Dorsal fractures of the triquetrum are frequently associated with dorsal carpal ligament injuries. Bone marrow edema distribution is not correlated with these ligament tears.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The main objective of this research was to examine the relationship between surface electromyographic (SEMG) spike activity and force. The secondary objective was to determine to what extent subcutaneous tissue impacts the high frequency component of the signal, as well as, examining the relationship between measures of SEMG spike shape and their traditional time and frequency analogues. A total of96 participants (46 males and 50 females) ranging in age (18-35 years), generated three 5-second isometric step contractions at each force level of 40, 60, 80, and 100 percent of maximal voluntary contraction (MVC). The presentation of the contractions was balanced across subjects. The right arm of the subject was positioned in the sagittal plane, with the shoulder and elbow flexed to 90 degrees. The elbow rested on a support in a neutral position (mid pronation/mid supination) and placed within a wrist cuff, fastened below the styloid process. The wrist cuff was attached to a load cell (JR3 Inc., Woodland, CA) recording the force produced. Biceps brachii activity was monitored with a pair of Ag/AgCI recording electrodes (Grass F-E9, Astro-Med Inc., West Warwick, RI) placed in a bipolar configuration, with an interelectrode distance (lED) of 2cm distal to the motor point. Data analysis was performed on a I second window of data in the middle of the 5-second contraction. The results indicated that all spike shape measures exhibited significant (p < 0.01) differences as force increase~ from 40 to 100% MVC. The spike shape measures suggest that increased motor unit (MU) recruitment was responsible for increasing force up to 80% MVC. The results suggested that further increases in force relied on MU III synchronization. The results also revealed that the subcutaneous tissue (skin fold thickness) had no relationship (r = 0.02; P > 0.05) with the mean number of peaks per spike (MNPPS), which was the high frequency component of the signal. Mean spike amplitude (MSA) and mean spike frequency (MSF) were highly correlated with their traditional measures root mean square (RMS) and mean power frequency (MPF), respectively (r = 0.99; r = 0.97; P < 0.01).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To analyze the effect of arm bracing posture on respiratory muscle strength and pulmonary function in patients with Chronic Obstructive Pulmonary Disease (COPD).Methods: 20 patients with COPD (11 male; 67 +/- 8 years; BMI 24 +/- 3 Kg . m(-2)) were submitted to assessments of Maximal Inspiratory and Expiratory Pressures (MIP and MEP, respectively) and spirometry with and without arm bracing in a random order. The assessment with arm bracing was done on standing position and the height of the support was adjusted at the level of the ulnar styloid process with elbow flexion and trunk anterior inclination of 30 degrees promoting weight discharge in the upper limbs. Assessment without arm bracing was also performed on standing position, however with the arms relaxed alongside the body. The time interval between assessments was one week.Results: MIP, MEP and maximal voluntary ventilation (MW) were higher with arm bracing than without arm bracing (MIP 64 +/- 22 cmH(2)O versus 54 +/- 24 cmH(2)O, p = 0,00001; MEP 104 +/- 37 cmH(2)O versus 92 +/- 37 cmH(2)O, p = 0,00001 and MW 42 +/- 20 L/min versus 38 +/- 20 L/min, p = 0,003). Other variables did not show statistical significant difference.Conclusion: The arm bracing posture resulted in higher capacity to generate force and endurance of the respiratory muscles in patients with COPD. (C) 2009 Published by Elsevier Espana, S.L. on behalf of Sociedade Portuguesa de Pneumologia. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Eagle syndrome is symptomatic elongation of the styloid process, or calcification of the stylomandibular ligament. Difficulty with deglutition. phonation. cervical movement. and the sensation of a foreign body in the oropharynx are all symptoms of this syndrome. Its treatment consists of partial removal of the styloid process. leaving it within the range of normality. We describe the technique, report it case, and point Out Sortie of the advantages. such as the simplicity of the procedure, reduced operating time, and lack risks of operative complications. (C) 2008 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Gegenstand der Arbeit: Die distale Radiusfraktur ist der häufigste Bruch des Menschen. Neben etablierten Verfahren wie der dorsalen und palmaren Plattenosteosynthese gibt es seit Kurzem neuartige minimalinvasive Osteosynthesesysteme. Gegenstand der vorliegenden Arbeit ist die Untersuchung der biomechanischen Stabilität von zwei neuartigen Implantaten für die distale extraartikuläre Radiusfraktur. rnMethodik: Es handelt sich einerseits um das System XSCREW (Zimmer, Freiburg i. Br., Deutschland), eine kanülierte Schraube, die über den Processus styloideus eingeführt wird und mit bis zu neun Bohrdrähten im Knochen fixiert werden kann. Das Vergleichsimplantat DorsalNailPlate (HandInnovations, Miami, Florida, USA) ist ein Hybrid aus einer dorsalen Platte und einem Marknagel. Beide Systeme wurden an 8 paarigen frischen unfixierten Leichenradii unter Axialbelastung bis 100 N und Torsionsbelastung bis 1,5 Nm getestet. Die A3-Fraktur wurde durch eine standardisierte Keilosteotomie simuliert. Das Biomaterial wurde prä- und postinterventionell sowie nach einem Dauerbelastungstest unter 1000 Zyklen in Rotation mit 0,5 Hz untersucht. Ein Versagenstest mit steigendem Drehmoment beendete das Experiment. rnErgebnisse: Die XSCREW erreichte eine Axialsteifigkeit von 136 N/mm und eine Torsionssteifigkeit von 0,16 Nm/°. Die DNP erzielte hingegen axial 70 N/mm und torsional 0,06 Nm/°. Der Unterschied zwischen beiden Verfahren war nur für die Torsion eindeutig statistisch auffällig (p=0,012), jedoch nicht für die Axialsteifigkeit (p=0,054). Die ursprüngliche Axial- und Torsionssteifigkeit wurde durch die XSCREW signifikant besser wiederhergestellt als durch die DNP (p=0,012). Beide Verfahren erzielten nach der Intervention signifikant niedrigere Steifigkeiten als die intakten Knochen (p=0,012). Ein Präparat der DNP-Gruppe und vier Präparate der XSCREW-Gruppe überstanden den Dauerbelastungstest. Das Drehmoment bei Versagen war mit der XSCREW höher als mit der DNP, der Unterschied zwischen den Verfahren war signifikant (p=0,043). Die Schwachstellen beider Systeme lagen vorwiegend in der proximalen Verankerung im Knochen. Kirschner-Drähte bzw. Verriegelungsschrauben führten unter andauernder Belastung zu einer Spaltung der Kortikalis im Schaftbereich. Bedingt durch die Ausrichtung der distalen Verriegelungen können mit beiden Implantaten Schäden an der radiocarpalen bzw. radioulnaren Gelenkfläche entstehen. rnZusammenfassung: Die XSCREW ermöglicht insgesamt eine höhere mechanische Stabilität als die DNP. Beide Verfahren sind jedoch einer winkelstabilen palmaren Plattenosteosynthese insbesondere unter rotatorischer Dauerbelastung unterlegen und erreichen nicht die Stabilität eines anderen neuartigen minimalinvasiven Systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A non-invasive in vivo technique was developed to evaluate changes in wrist joint stability properties induced by increased co-activation of the forearm muscles in a gripping task. Mechanical vibration at 45, 50 and 55 Hz was applied to the radial head in ten healthy volunteers. Vibrations of the styloid process of the radius and the distal end of the metacarpal bone of the index finger were measured with triaxial accelerometers. Joint stability properties were quantified by the transfer function gain between accelerations on either side of the wrist-joint. Gain was calculated with the muscles at rest and at five force levels ranging from 5% to 25% of maximum grip force (%MF). During contraction the gain was significantly greater than in control trial (0%MF) for all contractions levels at 45 and 50 Hz and a trend for 15%MF and higher at 55 Hz. Group means of contraction force and gain were significantly correlated at 45 (R-2 = 0.98) and 50 Hz (R-2 = 0.72), but not at 55 Hz (R-2 = 0.10). In conclusion, vibration transmission gain may provide a method to evaluate changes in joint stability properties. (c) 2005 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Systemic lupus erythematosus is an autoimmune disease that causes many psychological repercussions that have been studied through qualitative research. These are considered relevant, since they reveal the amplitude experienced by patients. Given this importance, this study aims to map the qualitative production in this theme, derived from studies of experiences of adult patients of both genders and that had used as a tool a semi-structured interview and/or field observations, and had made use of a sampling by a saturation criterion to determine the number of participants in each study. The survey was conducted in Pubmed, Lilacs, Psycinfo e Cochrane databases, searching productions in English and Portuguese idioms published between January 2005 and June 2012. The 19 revised papers that have dealt with patients in the acute phase of the disease showed themes that were categorized into eight topics that contemplated the experienced process at various stages, from the onset of the disease, extending through the knowledge of the diagnosis and the understanding of the manifestations of the disease, drug treatment and general care, evolution and prognosis. The collected papers also point to the difficulty of understanding, of the patients, on what consists the remission phase, revealing also that this is a clinical stage underexplored by psychological studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

20

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the facial symmetry of rats submitted to experimental mandibular condyle fracture and with protein undernutrition (8% of protein) by means of cephalometric measurements. METHODS: Forty-five adult Wistar rats were distributed in three groups: fracture group, submitted to condylar fracture with no changes in diet; undernourished fracture group, submitted to hypoproteic diet and condylar fracture; undernourished group, kept until the end of experiment, without condylar fracture. Displaced fractures of the right condyle were induced under general anesthesia. The specimens were submitted to axial radiographic incidence, and cephalometric mensurations were made using a computer system. The values obtained were subjected to statistical analyses among the groups and between the sides in each group. RESULTS: There was significative decrease of the values of serum proteins and albumin in the undernourished fracture group. There was deviation of the median line of the mandible relative to the median line of the maxilla, significative to undernutrition fracture group, as well as asymmetry of the maxilla and mandible, in special in the final period of experiment. CONCLUSION: The mandibular condyle fracture in rats with proteic undernutrition induced an asymmetry of the mandible, also leading to consequences in the maxilla.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of specimens' design and manufacturing process on microtensile bond strength, internal stress distributions (Finite Element Analysis - FEA) and specimens' integrity by means of Scanning Electron Microscopy (SEM) and Laser Scanning Confocal Microscopy (LCM). Excite was applied to flat enamel surface and a resin composite build-ups were made incrementally with 1-mm increments of Tetric Ceram. Teeth were cut using a diamond disc or a diamond wire, obtaining 0.8 mm² stick-shaped specimens, or were shaped with a Micro Specimen Former, obtaining dumbbell-shaped specimens (n = 10). Samples were randomly selected for SEM and LCM analysis. Remaining samples underwent microtensile test, and results were analyzed with ANOVA and Tukey test. FEA dumbbell-shaped model resulted in a more homogeneous stress distribution. Nonetheless, they failed under lower bond strengths (21.83 ± 5.44 MPa)c than stick-shaped specimens (sectioned with wire: 42.93 ± 4.77 MPaª; sectioned with disc: 36.62 ± 3.63 MPa b), due to geometric irregularities related to manufacturing process, as noted in microscopic analyzes. It could be concluded that stick-shaped, nontrimmed specimens, sectioned with diamond wire, are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.