22 resultados para Stethoscope
Resumo:
A telehealth stethoscope would make it possible for doctors to perform physical examinations on patients at great distances. In order to develop a useful and usable telehealth stethoscope we have conducted fieldwork observations of existing anaesthetic preadmission clinics to understand how stethoscopes are currently used. Both face-to-face consultations and videoconference consultations have been studied. Our results indicate that the stethoscope plays a minor role in the consultation and that consultations are mediated by the administrative work that is the reason for the consultation. We suggest that a stethoscope plays an infrastructural role in the consultation. The implications of considering stethoscopes as infrastructure are explored and considered in the context of a future telehealth stethoscope.
Resumo:
Background This research addresses the development of a digital stethoscope for use with a telehealth communications network to allow doctors to examine patients remotely (a digital telehealth stethoscope). A telehealth stethoscope would allow remote auscultation of patients who do not live near a major hospital. Travelling from remote areas to major hospitals is expensive for patients and a telehealth stethoscope could result in significant cost savings. Using a stethoscope requires great skill. To design a telehealth stethoscope that meets doctors’ expectations, the use of existing stethoscopes in clinical contexts must be examined. Method Observations were conducted of 30 anaesthetic preadmission consultations. The observations were video- taped. Interaction between doctor, patient and non-human elements in the consultation were “coded” to transform the video into data. The data were analysed to reveal essential aspects of the interactions. Results The analysis has shown that the doctor controls the interaction during auscultation. The conduct of auscultation draws heavily on the doctor’s tacit knowledge, allowing the doctor to treat the acoustic stethoscope as infrastructure – that is, the stethoscope sinks into the background and becomes completely transparent in use. Conclusion Two important, and related, implications for the design of a telehealth stethoscope have arisen from this research. First, as a telehealth stethoscope will be a shared device, doctors will not be able to make use of their existing expertise in using their own stethoscopes. Very simply, a telehealth stethoscope will sound different to a doctor’s own stethoscope. Second, the collaborative interaction required to use a telehealth stethoscope will have to be invented and refined. A telehealth stethoscope will need to be carefully designed to address these issues and result in successful use. This research challenges the concept of a telehealth stethoscope by raising questions about the ease and confidence with which doctors could use such a device.
Resumo:
We investigated the collaboration of ten doctor-nurse pairs with a prototype digital telehealth stethoscope. Doctors could see and hear the patient but could not touch them or the stethoscope. The nurse in each pair controlled the stethoscope. For ethical reasons, an experimenter stood in for a patient. Each of the ten interactions was video recorded and analysed to understand the interaction and collaboration between the doctor and nurse. The video recordings were coded and transformed into maps of interaction that were analysed for patterns of activity. The analysis showed that as doctors and nurses became more experienced at using the telehealth stethoscope their collaboration was more effective. The main measure of effectiveness was the number of corrections in stethoscope placement required by the doctor. In early collaborations, the doctors gave many corrections. After several trials, each doctor and nurse had reduced corrections and all pairs reduced their corrections. The significance of this research is the identification of the qualities of effective collaboration in the use of the telehealth stethoscope and telehealth systems more generally.
Resumo:
This article outlines the correct procedure for respiratory assessments using a stethoscope, how to use a stethoscope and how to interpret your findings.
Resumo:
In the absence of telehealth technology, rural patients must travel to a regional or metropolitan hospital for a preadmission consultation one week before their surgery. Currently, examination of the patient’s chest using a stethoscope (auscultation) is not possible over a telehealth network as existing digital stethoscopes have been designed for in-person auscultation. We report on the initial phase of research which ultimately aims to design a digital stethoscope for use in the telehealth context. This initial research phase describes the complexity of the activity of preadmission clinics and the implications for the design of the stethoscope. The research is conducted through field studies of existing face-to-face and remote consultations.
Resumo:
Objective: A literature review to examine the incorporation of respiratory assessment into everyday surgical nursing practice; possible barriers to this; and the relationship to patient outcomes. Primary argument: Escalating demands on intensive care beds have led to highly dependent patients being cared for in general surgical ward areas. This change in patient demographics has meant the knowledge and skills required of registered nurses in these areas has expanded exponentially. The literature supported the notion that postoperative monitoring of vital signs should include the fundamental assessment of respiratory rate; depth and rhythm; work of breathing; use of accessory muscles and symmetrical chest movement; as well as auscultation of lung fields using a stethoscope. Early intervention in response to changes in a patient's respiratory health status impacts positively on patient health outcomes. Substantial support exists for the contention that technologically adept nurses who also possess competent respiratory assessment skills make a difference to respiratory care. Conclusions: Sub-clinical respiratory problems have been demonstrated to contribute to adverse events. There is a paucity of research knowledge as to whether respiratory education programs and associated inservice make a difference to nursing clinical practice. Similarly, the implications for associated respiratory educational needs are not well documented, nor has a research base been sufficiently developed to guide nursing practice. Further research has the potential to influence the future role and function of the registered nurse by determining the importance of respiratory education programs on post-operative patient outcomes.
Resumo:
We report a blood pressure evaluation methodology by recording the radial arterial pulse waveform in real time using a fiber Bragg grating pulse device (FBGPD). Here, the pressure responses of the arterial pulse in the form of beat-to-beat pulse amplitude and arterial diametrical variations are monitored. Particularly, the unique signatures of pulse pressure variations have been recorded in the arterial pulse waveform, which indicate the systolic and diastolic blood pressure while the patient is subjected to the sphygmomanometric blood pressure examination. The proposed method of blood pressure evaluation using FBGPD has been validated with the auscultatory method of detecting the acoustic pulses (Korotkoff sounds) by an electronic stethoscope. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)
Resumo:
This article considers national policy drivers promoting the development of advanced assessment skills and practical procedures for the safe and effective use of the stethoscope in the clinical area. The evidence base underpinning effective use of the stethoscope in clinical practice is explored, including the preparation of the patient and the environment, applying infection control policies, and placing an emphasis on privacy and dignity. This is followed by a practical guide to auscultation technique of the respiratory system for nurses developing advanced practice skills.
Resumo:
Introduction: Lower Respiratory Tract Infections (LRTIs) are highly prevalent in institutionalised people with dementia, constituting an important cause of morbidity and mortality. Computerised auscultation of Adventitious Lung Sounds (ALS) has shown to be objective and reliable to assess and monitor respiratory diseases, however its application in people with dementia is unknown. Aim: This study characterised ALS (crackles and wheezes) in institutionalised people with dementia. Methods: An exploratory descriptive study, including 6 long-term care institutions was conducted. The sample included a dementia group (DG) of 30 people with dementia and a match healthy group (HG) of 30 elderly people. Socio-demographic and anthropometric data, cognition, type and severity of dementia, cardio-respiratory parameters, balance, mobility and activities and participation were collected. Lung sounds were recorded with a digital stethoscope following Computerised Respiratory Sound Analysis (CORSA) guidelines. Crackles’ location, number (N), frequency (F), two-cycle duration (2CD), initial deflection width (IDW) and largest deflection width (LDW) and wheezes’ number (N), ratio (R) and frequency (F) were analysed per breathing phase. Statistical analyses were performed using PASW Statistics(v.19). Results: There were no significant differences between the two groups in relation to the mean N of crackles during inspiration and expiration in both trachea and thorax. DG trachea crackles had significant higher F during inspiration and lower IDW, 2CD and LDW during expiration when compared with HG. At the thorax, the LDW during inspiration was also significantly lower in the DG. A significant higher N of inspiratory wheezes was found in the HG. Both groups had a low ratio of high frequency wheezes. Conclusion: Computerised analyses of ALS informed on the respiratory system and function of people with dementia and elderly people. Hence, this could be the step towards prevention, early diagnosis and continuous monitoring of respiratory diseases in people with cognitive impairment.
Resumo:
Os equipamentos de medição utilizados nos hospitais têm uma função muito importante na deteção e diagnóstico de doenças como é o caso da pressão arterial. Entre esses equipamentos encontram-se os esfigmomanómetros digitais portáteis que são em muitos casos os primeiros a serem utilizados e a fornecerem um primeiro diagnóstico da pressão arterial do doente como é no caso das urgências hospitalares. Para que os diagnósticos prescritos pelos profissionais de saúde - médicos e enfermeiros seja o mais correto é necessário conhecer as condições de trabalho em que se encontram os esfigmomanómetros digitais existentes nas unidades de saúde. Sendo os esfigmomanómetros digitais equipamentos com uma importância relevante na vida do ser humano, estes deveriam fazer parte da lista de equipamentos que estão englobados na metrologia legal, situação que neste momento ainda não foi concretizada e cada hospital toma a decisão espontânea se efetua a calibração ou verificação internamente dos seus esfigmomanómetros digitais. Pretende-se com este trabalho dar a conhecer o estado ao nível dos erros de alguns esfigmomanómetros digitais existentes nos hospitais envolvidos no trabalho e desenvolver um procedimento de verificação interna dos mesmos com auxílio de um manómetro analógico calibrado e um estetoscópio duplo – método de medição auscultatório - e comparar esses resultados com a utilização de um simulador – método de medição oscilométrico.
Resumo:
JUSTIFICATIVA E OBJETIVOS: A separação de gêmeos unidos causa grande interesse devido à complexidade da anestesia e cirurgia, à raridade da patologia e às poucas chances de sobrevida. O objetivo desta descrição é o de contribuir para a literatura existente, relatando os desafios encontrados por nossa equipe no atendimento à cirurgia-anestesia de separação de gêmeos isquiópagos. RELATO do CASO: Pacientes gêmeos, nascidos a termo, de parto cesariano, pesando juntos 5.100 g, classificados como isquiópagus tetrapus. Duas equipes anestésico-cirúrgicas estavam presentes, sendo o procedimento anestésico esquematizado com aparelho de anestesia, cardioscópio, capnógrafo, oxímetro de pulso, termômetro elétrico, estetoscópio esofágico, todos em dobro. Realizou-se indução anestésica com halotano e fentanil, com os gêmeos em posição lateral e com rotação da cabeça em 45º para facilitar a intubação traqueal. Os recém-nascidos foram mantidos em ventilação controlada manualmente, utilizando o sistema de Rees-Baraka. A anestesia foi mantida com halotano, oxigênio e fentanil. Durante o per-operatório, foram encontrados órgãos abdominais duplos, com exceção do cólon, que era único. As bexigas e os ísquios estavam ligados. Ao final da cirurgia as duas crianças apresentavam-se com sinais vitais estáveis. Os gêmeos permaneceram na Unidade de Terapia Intensiva (UTI) Neonatal por quatro semanas e receberam alta em bom estado geral. CONCLUSÕES: Ressalta-se a importância do entrosamento da equipe, do estudo retrospectivo multidisciplinar, da monitorização adequada e acurada observação clínica; todos esses fatores contribuíram para a boa evolução e alta dos gêmeos.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Engenharia Mecânica - FEG