5 resultados para Stereophotographs.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the clinical agreement in the detection of optic disk changes in patients with glaucoma using simultaneous stereophotographs. DESIGN: Masked-observer variability study. METHODS: Ten glaucoma specialists examined pairs of simultaneous stereophotographs of glaucomatous and control optic disks to determine whether there were changes compatible with progression of glaucomatous damage. RESULTS: Intraobserver agreement had a kappa value ranging from 0.55 to 0.78. Interobserver agreement among the glaucoma specialists had a kappa value ranging from 0.34 to 0.68. CONCLUSION: Clinical examination of stereophotographs to detect optic disk changes in glaucoma patients has limitations associated with suboptimal reproducibility. © 2003 by Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study was designed to evaluate the clinical agreement in the detection of optic disc changes and the ability of computerized image analysis to detect glaucomatous deterioration of the optic disc. Methods: Pairs of stereophotographs of 35 glaucomatous optic discs taken 5 years apart and of 5 glaucomatous discs photographed twice on the same day. Two glaucoma specialists examined the pairs of stereophotographs (35 cases and 5 controls) in a masked manner and judged whether the optic disc showed changes in the optic disc compatible with progression of glaucomatous damage. The stereophotographs of the five optic discs photographed twice on the same day (which by definition did not change) and of five cases judged to have deteriorated by both glaucoma specialists were analyzed by computerized image analysis with the Topcon ImageNet system. Intra- and inter-observer agreement in the detection of optic disc changes (evaluated using kappa statistic), and changes in the rim area to disc area ratio (evaluated using descriptive statistics and paired t-test). Results: Intra-observer agreement had a kappa value of 0.75 for observer 1 and 0.60 for the observer 2. Inter-observer agreement between the glaucoma specialists had a kappa value of 0.60. The image analyzer did not discriminate between controls and cases with clinically apparent glaucomatous change of the optic disc. Conclusion: Clinical agreement in detecting changes in the optic disc was moderate to substantial. Computerized image analysis with the Topcon ImageNet system appeared not to be useful in detecting glaucomatous changes of the optic disc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To characterize optic nerve head (ONH) anatomy related to the clinical optic disc margin with spectral domain-optical coherence tomography (SD-OCT). Design: Cross-sectional study. Participants: Patients with open-angle glaucoma with focal, diffuse, and sclerotic optic disc damage, and age-matched normal controls. Methods: High-resolution radial SD-OCT B-scans centered on the ONH were analyzed at each clock hour. For each scan, the border tissue of Elschnig was classified for obliqueness (internally oblique, externally oblique, or nonoblique) and the presence of Bruch's membrane overhanging the border tissue. Optic disc stereophotographs were co-localized to SD-OCT data with customized software. The frequency with which the disc margin identified in stereophotographs coincided with (1) Bruch's membrane opening (BMO), defined as the innermost edge of Bruch's membrane; (2) Bruch's membrane/border tissue, defined as any aspect of either outside BMO or border tissue; or (3) border tissue, defined as any aspect of border tissue alone, in the B-scans was computed at each clock hour. Main Outcome Measures: The SD-OCT structures coinciding with the disc margin in stereophotographs. Results: There were 30 patients (10 with each type of disc damage) and 10 controls, with a median (range) age of 68.1 (42-86) years and 63.5 (42-77) years, respectively. Although 28 patients (93%) had 2 or more border tissue configurations, the most predominant one was internally oblique, primarily superiorly and nasally, frequently with Bruch's membrane overhang. Externally oblique border tissue was less frequent, observed mostly inferiorly and temporally. In controls, there was predominantly internally oblique configuration around the disc. Although the configurations were not statistically different between patients and controls, they were among the 3 glaucoma groups. At most locations, the SD-OCT structure most frequently identified as the disc margin was some aspect of Bruch's membrane and border tissue external to BMO. Bruch's membrane overhang was regionally present in the majority of patients with glaucoma and controls; however, in most cases it was not visible as the disc margin. Conclusions: The clinically perceived disc margin is most likely not the innermost edge of Bruch's membrane detected by SD-OCT. These findings have important implications for the automated detection of the disc margin and estimates of the neuroretinal rim. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2012;119:738-747 (C) 2012 by the American Academy of Ophthalmology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mode of access: Internet.