Clinical agreement among glaucoma experts in the detection of glaucomatous changes of the optic disk using simultaneous stereoscopic photographs
Data(s) |
01/11/2003
|
---|---|
Resumo |
PURPOSE: To evaluate the clinical agreement in the detection of optic disk changes in patients with glaucoma using simultaneous stereophotographs. DESIGN: Masked-observer variability study. METHODS: Ten glaucoma specialists examined pairs of simultaneous stereophotographs of glaucomatous and control optic disks to determine whether there were changes compatible with progression of glaucomatous damage. RESULTS: Intraobserver agreement had a kappa value ranging from 0.55 to 0.78. Interobserver agreement among the glaucoma specialists had a kappa value ranging from 0.34 to 0.68. CONCLUSION: Clinical examination of stereophotographs to detect optic disk changes in glaucoma patients has limitations associated with suboptimal reproducibility. © 2003 by Elsevier Inc. All rights reserved. |
Identificador | |
Idioma(s) |
eng |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Azuara-Blanco , A , Katz , L J , Spaeth , G L , Vernon , S A , Spencer , F & Lanzl , I M 2003 , ' Clinical agreement among glaucoma experts in the detection of glaucomatous changes of the optic disk using simultaneous stereoscopic photographs ' American Journal of Ophthalmology , vol 136 , no. 5 , pp. 949-950 . DOI: 10.1016/S0002-9394(03)00480-X |
Tipo |
article |