990 resultados para Stents and prostheses
Resumo:
Commercial stents, especially metallic ones, present several disadvantages, and this gives rise to the necessity of producing or coating stents with different materials, like natural polymers, in order to improve their biocompatibility and minimize the disadvantages of metallic ones. This review paper discusses some applications of natural-based polymers in stents, namely polylactic acid (PLA) for stent development and chitosan for biocompatible coatings of stents . Furthermore, some effective stent functionalization techniques will be discussed, namely Layer by Layer (LBL) technique.
Resumo:
Cancer is regarded as the abnormal cellular multiplication; it is not controlled by the organism; and its cells present a differentiated DNA. Initially, the disease does not show clinical signs, but it can be diagnosed by laboratorial examinations. When tumors are present in the maxillofacial area, they can entail the loss of these area organs, which become responsible for the carrier's social environment exclusion. This paper aimed at showing, through a literature review, the cancers that more commonly happen in the face and the possibilities of regenerating in the patient mutilated through surgical reconstruction and prostheses.
Resumo:
BACKGROUND Newer generation everolimus-eluting stents (EES) improve clinical outcome compared to early generation sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES). We investigated whether the advantage in safety and efficacy also holds among the high-risk population of diabetic patients during long-term follow-up. METHODS Between 2002 and 2009, a total of 1963 consecutive diabetic patients treated with the unrestricted use of EES (n=804), SES (n=612) and PES (n=547) were followed throughout three years for the occurrence of cardiac events at two academic institutions. The primary end point was the occurrence of definite stent thrombosis. RESULTS The primary outcome occurred in 1.0% of EES, 3.7% of SES and 3.8% of PES treated patients ([EES vs. SES] adjusted HR=0.58, 95% CI 0.39-0.88; [EES vs. PES] adjusted HR=0.29, 95% CI 0.13-0.67). Similarly, patients treated with EES had a lower risk of target-lesion revascularization (TLR) compared to patients treated with SES and PES ([EES vs. SES], 5.6% vs. 11.5%, adjusted HR=0.68, 95% CI: 0.55-0.83; [EES vs. PES], 5.6% vs. 11.3%, adjusted HR=0.51, 95% CI: 0.33-0.77). There were no differences in other safety end points, such as all-cause mortality, cardiac mortality, myocardial infarction (MI) and MACE. CONCLUSION In diabetic patients, the unrestricted use of EES appears to be associated with improved outcomes, specifically a significant decrease in the need for TLR and ST compared to early generation SES and PES throughout 3-year follow-up.
Resumo:
INTRODUCTION Aim of this multicentric study:to compare the short-and mid-term results of bare metal stents(BMS)and covered stents(CS)in the Kissing Stent(KS)technique. METHODS Patients undertaking a KS with BMS or CS between January 2017-August 2021 included. Morphological features of plaques were classified as per the extension of calcifications and thrombosis. Every endpoint and outcome was compared in relation to BMS or CS. All patients included received dual anti-platelets DAPT)for at least one month. RESULTS Thirty-four patients enrolled,17 treated with BMS and 17 with CS. Average age 66 years. The 80% of patients were part of TASC C-D categories. DAPT was administered to 82.4%(28/34)of patients with a mean duration of 4.4±1.6 months. Mean follow-up 32.1±17.8 months. Technical Success was 100%. Immediate Clinical Success was reached in 29 cases(85.3%). Immediate and 30-day Clinical Success was higher in CS(64.7% vs 100%, p=.01). Overall Clinical Success at 1-year follow-up was 91.2%,and resulted significantly higher in CS(82.4% vs 100%,p .04). Overall Primary Patency,Assisted Patency,and Secondary Patency at 30 days were 97.1%,97.1%,and 100%,without differences between BMS and CS(94.1% vs 100%,94.1% vs 100%,and 100% vs 100%;p =.7). Two cases(5.9%)of thrombosis were registered,and both occurred within 3 months after the procedure and both in the BMS,without statistical differences with the CS group(11.8% vs 0%,p .48). Both cases of thrombosis occurred in patients who were not treated with dual antiplatelet therapy(33.3% vs 0%,p .027). Survival statistically differed only at the mean follow-up in favour of CS(70.6% and 100%,p .04). CONCLUSIONS The endovascular approach is currently safe and effective in the treatment of AIOD,and KS offers excellent results in particular if performed with CS; however,no statistically significant differences emerged between the two types of stents in terms of patency,reintervention,and complications. DAPT seems to warrant the best results in terms of patency,although there is still no consensus about the ideal duration of administration.
Resumo:
Videolaparoscopy has been widely used in the treatment of pathologies as cholelithiasis, appendicitis and adrenal tumor. Nowadays, has also been used to treat type II endoleaks after endovascular repair of abdominal aortic aneurysms. The goal of this work is to report one case of inferior mesenteric artery endoleak treated by videolaparoscopy.
Resumo:
The relative safety of drug-eluting stents and bare-metal stents, especially with respect to stent thrombosis, continues to be debated. In view of the overall low frequency of stent thrombosis, large sample sizes are needed to accurately estimate treatment differences between stents. We compared the risk of thrombosis between bare-metal and drug-eluting stents.
Resumo:
OBJECTIVES This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. METHODS Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. RESULTS Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. CONCLUSIONS Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.
Resumo:
BACKGROUND Histologic experimental studies have reported incomplete neointimal healing in overlapping with respect to nonoverlapping segments in drug-eluting stents (DESs), but these observations have not been confirmed in human coronary arteries hitherto. On the contrary, angiographic and optical coherence tomography studies suggest that DES overlap elicits rather an exaggerated than an incomplete neointimal reaction. METHODS Optical coherence tomography studies from 2 randomized trials including sirolimus-eluting, biolimus-eluting, everolimus-eluting, and zotarolimus-eluting stents were analyzed at 9- to 13-month follow-up. Coverage in overlapping segments was compared versus the corresponding nonoverlapping segments of the same stents, using statistical pooled analysis. RESULTS Forty-two overlaps were found in 31 patients: 11 in sirolimus-eluting stents, 3 in biolimus-eluting stents, 17 in everolimus-eluting stents, and 11 in zotarolimus-eluting stents. The risk ratio of incomplete coverage was 2.35 (95% CI 1.86-2.98) in overlapping versus nonoverlapping segments. Thickness of coverage in overlaps was only 85% (95% CI 81%-90%) of the thickness in nonoverlaps. Significant heterogeneity of the effect was observed, especially pronounced in the comparison of thickness of coverage (I(2) = 90.31). CONCLUSIONS The effect of overlapping DES on neointimal inhibition is markedly heterogeneous: on average, DES overlap is associated with more incomplete and thinner coverage, but in some cases, the overlap elicits an exaggerated neointimal reaction, thicker than in the corresponding nonoverlapping segments. These results might help to understand why overlapping DES is associated with worse clinical outcomes, both in terms of thrombotic phenomena and in terms of restenosis and revascularization.
Resumo:
Purpose: To assess the 5-year survival rate and number of technical, biologic, and esthetic complications involving implant abutments. Materials and Methods: Electronic (Medline) and hand searches were performed to assess studies on metal and ceramic implant abutments. Relevant data from a previous review were included. Two reviewers independently extracted the data. Failure and complication rates were analyzed, and estimates of 5-year survival proportions were calculated from the relationship between event rate and survival function. Multivariable robust Poisson regression was used to compare abutment characteristics. Results: The search yielded 1,558 titles and 274 abstracts. Twenty-four studies were selected for data analysis. The survival rate for ceramic abutments was 97.5% (95% confidence interval [CI]): 89.6% to 99.4%) and 97.6% (95% CI: 96.2% to 98.5%) for metal abutments. The overall 5-year rate for technical complications was 11.8% (95% CI: 8.5% to 16.3%), 8.9% (95% CI: 4.3% to 17.7%) for ceramic and 12.0% (95% CI: 8.5% to 16.8%) for metal abutments. Biologic complications occurred with an overall rate of 6.4% (95% CI: 3.3% to 12.0%), 10.4% (95% CI: 1.9% to 46.7%) for ceramic, and 6.1% (95% CI: 3.1% to 12.0%) for metal abutments. Conclusions: The present meta-analysis on single-implant prostheses presents high survival rates of single implants, abutments, and prostheses after 5 years of function. No differences were found for the survival and failure rates of ceramic and metal abutments. No significant differences were found for technical, biologic, and esthetic complications of internally and externally connected abutments.
Resumo:
BACKGROUND Newer-generation drug-eluting stents that release zotarolimus or everolimus have been shown to be superior to the first-generation drug-eluting stents. However, data comparing long-term safety and efficacy of zotarolimus- (ZES) and everolimus-eluting stents (EES) are limited. RESOLUTE all-comers (Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) trial compared these 2 stents and has shown that ZES was noninferior to EES at 12-month for the primary end point of target lesion failure. We report the secondary clinical outcomes at the final 5-year follow-up of this trial. METHODS AND RESULTS RESOLUTE all-comer clinical study is a prospective, multicentre, randomized, 2-arm, open-label, noninferiority trial with minimal exclusion criteria. Patients (n=2292) were randomly assigned to treatment with either ZES (n=1140) or EES (n=1152). Patient-oriented composite end point (combination of all-cause mortality, myocardial infarction, and any revascularizations), device-oriented composite end point (combination of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization), and major adverse cardiac events (combination of all-cause death, all myocardial infarction, emergent coronary bypass surgery, or clinically indicated target lesion revascularization) were analyzed at 5-year follow-up. The 2 groups were well-matched at baseline. Five-year follow-up data were available for 98% patients. There were no differences in patient-oriented composite end point (ZES 35.3% versus EES 32.0%, P=0.11), device-oriented composite end point (ZES 17.0% versus EES 16.2%, P=0.61), major adverse cardiac events (ZES 21.9% versus EES 21.6%, P=0.88), and definite/probable stent thrombosis (ZES 2.8% versus EES 1.8%, P=0.12). CONCLUSIONS At 5-year follow-up, ZES and EES had similar efficacy and safety in a population of patients who had minimal exclusion criteria. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00617084.
Resumo:
INTRODUCTION & OBJECTIVES: Urothelial tumors of upper urinary tract are ranked among the most common types of cancers worldwide. The current standard therapy to prevent recurrence is intravesical Bacillus Calmetteâ Guerin (BCG) immunotherapy, but it presents several disadvantages such as BCG failure and intolerance. Another way is to use chemotherapy, which is generally better tolerated that BCG. In this case, drugs such as epirubicin, doxorubicin, paclitaxel and gemcitabine are used. Nevertheless, intravesical chemotherapy only prevents recurrence in the short-term. These failings can be partially attributed to the short residence time and low bioavailability of the drug within the upper urinary tract and the cancer cells, resulting in a need for frequent drug instillation. To avoid these problems, biodegradable ureteral stents impregnated by supercritical fluid CO2 (SCF) with each of the four anti-cancer drugs were produced. MATERIAL & METHODS: Four formulations with different concentrations of gelatin and alginate and crosslink agent were tested and bismuth was added to confer radiopaque properties to the stent. The preliminary in vivo validation studies in female domestic pigs was conducted at the University of Minho, Braga, after formal approval by the institutionâ s review board and in accordance with its internal ethical protocol for animal experiments. Paclitaxel, epirubicin, doxorubicin and gemcitabine were impregnated in the stents and the release kinetics was measured in artificial urine solution (AUS) for 9 days by UV spectroscopy in a microplate reader. The anti-tumoral effect of the developed stents in transitional cell carcinoma (TCC) and HUVEC primary cells, used as control, was evaluated. RESULTS: The in vivo validation of this second-generation of ureteral stents performed was herein demonstrated. Biodegradable ureteral stents were placed in the ureters of a female pigs, following the normal surgical procedure. The animals remained asymptomatic, with normal urine flow. The in vitro release study in AUS of the stent impregnated showed a higher release in the first 72h for the four anti-cancer drugs impregnated after this time the plateau was achieved and the stent degraded after 9 days. The direct and indirect contact of the anti-cancer biodegradable stents with the TCC and HUVEC cell lines confirm the anti-tumor effect of the stents impregnated with the four anti-cancer drugs, reducing around 75% of the viability of the TCC cell line after 72h and no killing effect in the HUVEC cells. CONCLUSIONS: The use of biodegradable ureteral stent in urology clinical practice not only reduce the stent-related symptoms but also open new treatment therapyâ s, like in urothelial tumors of upper urinary tract. Furthermore, we have demonstrated the clinical validation in vivo pig model. This study has thus shown the killing efficacy of the anti-cancer drug eluting biodegradable stents in vitro for the TCC cell line, with no toxicity observed in the control, non-cancerous cells.The direct and indirect contact of the anti-cancer biodegradable stents with the TCC and HUVEC cell lines confirm the anti-tumor effect of the stents impregnated with the four anti-cancer drugs, reducing around 75% of the viability of the TCC cell line after 72h and no killing effect in the HUVEC cells. This study has thus shown the killing efficacy of the anti-cancer drug eluting biodegradable stents in vitro for the TCC cell line, with no toxicity observed in the control, non-cancerous cells.
Resumo:
Background: The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective: To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods: This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Results: Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Conclusions: Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.
Resumo:
PURPOSE: The perioperative treatment of patients on dual antiplatelet therapy after myocardial infarction, cerebrovascular event or coronary stent implantation represents an increasingly frequent issue for urologists and anesthesiologists. We assess the current scientific evidence and propose strategies concerning treatment of these patients. MATERIALS AND METHODS: A MEDLINE and PubMed search was conducted for articles related to antiplatelet therapy after myocardial infarction, coronary stents and cerebrovascular events, as well as the use of aspirin and/or clopidogrel in the context of surgery. RESULTS: Early discontinuation of antiplatelet therapy for secondary prevention is associated with a high risk of coronary thrombosis, which is further increased by the hypercoagulable state induced by surgery. Aspirin has recently been recommended as a lifelong therapy. Clopidogrel is mandatory for 6 weeks after myocardial infarction and bare metal stents, and for 12 months after drug-eluting stents. Surgery must be postponed beyond these waiting periods or performed with patients receiving dual antiplatelet therapy because withdrawal therapy increases 5 to 10 times the risk of postoperative myocardial infarction, stent thrombosis or death. The shorter the waiting period between revascularization and surgery the greater the risk of adverse cardiac events. The risk of surgical hemorrhage is increased approximately 20% by aspirin and 50% by clopidogrel. CONCLUSIONS: The risk of coronary thrombosis when antiplatelet agents are withdrawn before surgery is generally higher than the risk of surgical hemorrhage when antiplatelet agents are maintained. However, this issue has not yet been sufficiently evaluated in urological patients and in many instances during urological surgery the risk of bleeding can be dangerous. A thorough dialogue among surgeon, cardiologist and anesthesiologist is essential to determine all risk factors and define the best possible strategy for each patient.