895 resultados para Steel-Concrete Composite Structure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite experimental evidences, the contributions of the concrete slab and composite action to the vertical shear strength of simply supported steel-concrete composite beams are not considered in current design codes, which lead to conservative designs. In this paper, the finite element method is used to investigate the flexural and shear strengths of simply supported composite beams under combined bending and shear. A three-dimensional finite element model has been developed to account for geometric and material nonlinear behavior of composite beams, and verified by experimental results. The verified finite element model is than employed to quantify the contributions of the concrete slab and composite action to the moment and shear capacities of composite beams. The effect of the degree of shear connection on the vertical shear strength of deep composite beams loaded in shear is studied. Design models for vertical shear strength including contributions from the concrete slab and composite action and for the ultimate moment-shear interaction ate proposed for the design of simply supported composite beams in combined bending and shear. The proposed design models provide a consistent and economical design procedure for simply supported composite beams.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho académico com o objetivo do autor desenvolver um estudo prévio e um projeto de uma travessia sobre o rio Lima, na cidade de Viana do Castelo constituída por uma ponte de tirantes rodoferroviária. O projeto académico visa, também, desenvolver e compreender: os conceitos básicos, as metodologias de conceção, e o funcionamento de estruturas desse género. O motivo principal da escolha do tema é a necessidade de uma alternativa à ponte Eiffel em Viana do Castelo, e juntando o facto de em Portugal não existir nenhuma obra de arte de tirantes rodoferroviária até ao presente, seria interessante estudar e projetar uma estrutura rodoferroviária de tirantes. Das diversas possibilidades de sistemas estruturais estudados, adotou-se uma ponte que acomodará 4 vias rodoviárias e 2 vias ferroviárias, com um desenvolvimento total de 660 metros, constituída por dois vãos laterais com 165 metros cada um, e com um vão central de 330 metros. A obra de arte será em semi-leque com dois planos de tirantes, ancorados a duas torres de betão em Y invertido de altura aproximadamente de 110 metros. O tabuleiro será duplo misto aço-betão, constituído por duas vigas trianguladas do tipo Warren, e por carlingas, afastadas entre si de 15 metros com secções tubulares metálicas de espessura variável. As carlingas ao nível superior suportam a laje de betão, que constitui a rodovia, e inferiormente, suportam outra laje de betão para a parte ferroviária. O trabalho inicia-se com o enquadramento conceptual geral da envolvente da obra de arte, seguidamente com apresentação da evolução histórica ao longo do tempo das pontes de tirantes, e à apresentação de algumas pontes rodoferroviárias de tirantes. É realizada uma análise preliminar, onde se estudam as restrições, as condicionantes, o local de implantação, e o sistema da configuração geométrica a adotar na conceção estrutural. São descritos todos os tipos de materiais, equipamentos a utilizar, bem como as suas características mecânicas necessárias para o cálculo estrutural. A quantificação das ações e das combinações de cálculo efetuaram-se de acordo com as normas em vigor nacionais e europeias, designadamente os Eurocódigos das várias especialidades e o Regulamento de Segurança e Ações para Estruturas de Edifícios e Pontes. Efetuou-se um pré-dimensionamento e uma otimização de vários sistemas estruturais possíveis de todos os elementos estruturais, tendo em conta variáveis de estudo como a economia e a resistência estrutural das secções, por forma a chegar à solução final. A estrutura foi discretizada e analisada num modelo estático tridimensional num programa de cálculo automático. A análise de resultados foi efetuada longitudinalmente para a verificação dos Estados Limites Últimos e Estados Limites de Utilização dos elementos estruturais que constituem a ponte. Foi ainda efetuada uma estimativa orçamental da ponte no rio Lima na cidade de Viana do Castelo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper shows the results of an experimental investigation carried out on a connection element of glulam and concrete composite structures, through double-sided push-out shear tests. The connection system was composed of perforated steel plates glued with epoxy adhesive. Five specimens were made and tested under shear forces. This innovative connection system showed an average initial slip modulus equivalent to 339.4 kN/mm. In addition, the connection system was evaluated by means of numerical simulations and the software ANSYS was used for this purpose. The numerical simulations demonstrated good agreement with the experimental data, especially in the regime of elastic-linear behavior of materials. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an investigation of design code provisions for steel-concrete composite columns. The study covers the national building codes of United States, Canada and Brazil, and the transnational EUROCODE. The study is based on experimental results of 93 axially loaded concrete-filled tubular steel columns. This includes 36 unpublished, full scale experimental results by the authors and 57 results from the literature. The error of resistance models is determined by comparing experimental results for ultimate loads with code-predicted column resistances. Regression analysis is used to describe the variation of model error with column slenderness and to describe model uncertainty. The paper shows that Canadian and European codes are able to predict mean column resistance, since resistance models of these codes present detailed formulations for concrete confinement by a steel tube. ANSI/AISC and Brazilian codes have limited allowance for concrete confinement, and become very conservative for short columns. Reliability analysis is used to evaluate the safety level of code provisions. Reliability analysis includes model error and other random problem parameters like steel and concrete strengths, and dead and live loads. Design code provisions are evaluated in terms of sufficient and uniform reliability criteria. Results show that the four design codes studied provide uniform reliability, with the Canadian code being best in achieving this goal. This is a result of a well balanced code, both in terms of load combinations and resistance model. The European code is less successful in providing uniform reliability, a consequence of the partial factors used in load combinations. The paper also shows that reliability indexes of columns designed according to European code can be as low as 2.2, which is quite below target reliability levels of EUROCODE. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper was evaluated, using the software ANSYS, the stiffness (El) of the log-concrete composite beams, of section T, with connectors formed by bonded-in steel rods, type CA-50, disposed in X, with application of cyclical load. The stiffness of the system was evaluated through the simulation of bending tests, considered 1/2 beam, with cyclical shipment varying among 40 % and 5 % of the strength of the connection with the load relationship R=0,125, for a total of 10 load cycles applied. The numeric results show a good agreement with experimental tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an experimental analysis of the confinement effects in steel-concrete composite columns regarding two parameters: concrete compressive strength and column slenderness. Sixteen concrete-filled steel tubular columns with circular cross section were tested under axial loading. The tested columns were filled by concrete with compressive strengths of 30, 60. 80, and 100 MPa, and had length/diameter ratios of 3, 5, 7, and 10. The experimental values of the columns` ultimate load were compared to the predictions of 4 code provisions: the Brazilian Code NBR 8800:2008, Eurocode 4 (EN 1994-1-1:2004), AINSI/AISC 360:2005, and CAN/CSA S16-01:2001. According to the results, the load capacity of the composite columns increased with increasing concrete strength and decreased with increasing length/diameter ratio. In general, the code provisions were highly accurate in the prediction of column capacity. Among them, the Brazilian Code was the most conservative, while Eurocode 4 presented the values closest to the experimental results. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of mechanical shear connectors, mainly headed stud bolts, is the most common way to achieve steel-concrete composite action. The encasement of the steel beam in the depth slab results in increase of strength and stiffness, reducing the total height of the floor. In this investigation, three partially encased composite beams were tested under flexural conditions and the main objective was to investigate some alternative positions for the headed studs. To provide longitudinal shear resistance between the I-shaped beam and the concrete, two positions of the,studs were investigated: vertically welded on the bottom flange and horizontally welded on the faces of the web. The experimental results have shown that the headed studs are effective to provide the composite action and increase the bending strength. Furthermore, the headed studs welded vertically on the bottom flange proved to be the most reliable position.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we present two Partial Least Squares Regression (PLSR) models for compressive and flexural strength responses of a concrete composite material reinforced with pultrusion wastes. The main objective is to characterize this cost-effective waste management solution for glass fiber reinforced polymer (GFRP) pultrusion wastes and end-of-life products that will lead, thereby, to a more sustainable composite materials industry. The experiments took into account formulations with the incorporation of three different weight contents of GFRP waste materials into polyester based mortars, as sand aggregate and filler replacements, two waste particle size grades and the incorporation of silane adhesion promoter into the polyester resin matrix in order to improve binder aggregates interfaces. The regression models were achieved for these data and two latent variables were identified as suitable, with a 95% confidence level. This technological option, for improving the quality of GFRP filled polymer mortars, is viable thus opening a door to selective recycling of GFRP waste and its use in the production of concrete-polymer based products. However, further and complementary studies will be necessary to confirm the technical and economic viability of the process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"NRC FIN no. B5688."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The contributions of the concrete slab and composite action to the vertical shear strength of continuous steel-concrete composite beams are ignored in current design codes, which result in conservative designs. This paper investigates the ultimate strength of continuous composite beams in combined bending and shear by using the finite element analysis method. A three-dimensional finite element model has been developed to account for the geometric and material nonlinear behaviour of continuous composite beams. The finite element model is verified by experimental results and then used to study the effects of the concrete slab and shear connection on the vertical shear strength. The moment-shear interaction strength of continuous composite beams is also investigated by varying the moment/ shear ratio. It is shown that the concrete slab and composite action significantly increase the ultimate strength of continuous composite beams. Based on numerical results, design models are proposed for the vertical shear strength and moment-shear interaction of continuous composite beams. The proposed design models, which incorporates the effects of the concrete slab, composite action, stud pullout failure and web shear buckling, are compared with experimental results with good agreement. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este relatório é elaborado no âmbito do estágio curricular no regime de parceria entre o Instituto Superior de Engenharia do Porto e o gabinete de projetos SE2P – Sociedade de Engenharia, Projetos e Planeamento, Lda. O tema do estágio é o estudo de colunas mistas aço-betão na vertente de projeto, mais concretamente através da criação dum processo de cálculo automático integrado com o modelo estrutural global. Aplicam-se os métodos de dimensionamento dos eurocódigos estruturais na avaliação da segurança dos estados limites. Avaliam-se as propriedades geométricas, determina-se a curva de interação, calcula-se a posição do eixo neutro donde se inferem os estados de tensão em flexão desviada ao nível da secção, necessários às verificações de segurança. O processo de cálculo tem por base uma folha de cálculo desenvolvida em Excel que, com ajuda do Visual Basic for Applications, comunica com o software de modelação e cálculo estrutural Autodesk Robot Professional Analisys. Cria-se fluxos de informação que possibilitam o cálculo iterativo de colunas mistas permitindo ajustar e por esta via otimizar as soluções de dimensionamento. A exportação de relatórios de cálculo detalhados para cada coluna constitui uma mais-valia para gabinetes de engenharia quando comparada com outras soluções de dimensionamento existentes no mercado. A aplicação do processo de cálculo desenvolvido a múltiplas combinações de soluções de colunas mistas permitiu analisar comparativamente os resultados obtidos e a criação de tabelas e ábacos que poderão ser úteis em cenários de pré-dimensionamento e de anteprojeto.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Vicario Viaduct is located in the A-44 motorway, in the South-East part of Spain. It crosses a natural gorge, near the town of Ízbor in the province of Granada. A single continuous steel concrete composite deck, 24 m wide and 175 m long, divided in two 87,5 m spans, has been built. The cross section is a single structural steel box, 8,00 m wide and 4,52 m deep. The total width of 24 m is reached adding a strut and tie system each 4,375 m on both sides of the box. The steel parts of the deck were entirely constructed in the workshop and then they were erected on site just behind one of the abutments. Finally a 27.5 m long steel nose was connected to launch the deck. The main problems have been the curved shape of the deck (1420 m radius in plan) producing a non symmetric transverse distribution of reactions on each support and the cantilever reaching 87,5 m long, producing a maximum deflection of 1500 mm

Relevância:

100.00% 100.00%

Publicador:

Resumo:

GFRP pultruded profiles have shown to be structural profiles with great stiffness, strenght and very low specific weight, making it a great candidate for the rehabilitation of damaged strucutres. To further enhance the strucutral mechanism of these type of beams, the Slimflor composite structural system has lead as basis for this analysis; by replacing the steel beam with a GFRP pultruded profile. To further increase its composite action, a continuous shear connector has been set as part of the beam cross section as well as its needed reinforcement and fire protection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The growing demand for knowledge about the effect of high temperatures on structures has stimulated increasing research worldwide. This article presents experimental results for short composite steel and concrete columns subjected to high temperatures in ovens with or without an axial compression load, numerically analyzes the temperature distribution in these columns after 30 and 60 minutes and compares them with experimental results. The models consist of concrete-filled tubes of three different thicknesses and two different diameters, and the concrete fill has conventional properties that remained constant for all of the models. The stress-strain behavior of the composite columns was altered after exposure to high temperatures relative to the same columns at room temperature, which was most evident in the 60-minute tests due to the higher temperatures reached. The computational analysis adopted temperature rise curves that were obtained experimentally.