Evaluation of perforated steel plates as connection in glulam-concrete composite structures
Contribuinte(s) |
UNIVERSIDADE DE SÃO PAULO |
---|---|
Data(s) |
23/10/2013
23/10/2013
2012
|
Resumo |
This paper shows the results of an experimental investigation carried out on a connection element of glulam and concrete composite structures, through double-sided push-out shear tests. The connection system was composed of perforated steel plates glued with epoxy adhesive. Five specimens were made and tested under shear forces. This innovative connection system showed an average initial slip modulus equivalent to 339.4 kN/mm. In addition, the connection system was evaluated by means of numerical simulations and the software ANSYS was used for this purpose. The numerical simulations demonstrated good agreement with the experimental data, especially in the regime of elastic-linear behavior of materials. (C) 2011 Elsevier Ltd. All rights reserved. CNPq (Conselho Nacional de Desenvolvimento Cientifico e Tecnologico) Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) |
Identificador |
CONSTRUCTION AND BUILDING MATERIALS, OXFORD, v. 28, n. 1, pp. 216-223, MAR, 2012 0950-0618 http://www.producao.usp.br/handle/BDPI/35693 10.1016/j.conbuildmat.2011.08.045 |
Idioma(s) |
eng |
Publicador |
ELSEVIER SCI LTD OXFORD |
Relação |
CONSTRUCTION AND BUILDING MATERIALS |
Direitos |
restrictedAccess Copyright ELSEVIER SCI LTD |
Palavras-Chave | #GLULAM-CONCRETE JOINTS #SHEAR STRENGTH #PUSH-OUT #PERFORATED STEEL PLATES #EXPERIMENTAL EVALUATION #NUMERICAL EVALUATION #FLOORS #BEAMS #CONSTRUCTION & BUILDING TECHNOLOGY #MATERIALS SCIENCE, MULTIDISCIPLINARY |
Tipo |
article original article publishedVersion |