1000 resultados para Stability
Resumo:
High resolution thermogravimetry has been used to evaluate the carbonaceous content in a commercial sample of single-walled carbon nanotube (SWNT). The content of SWNTs in the sample was found to be at least 77mass% which was supported by images obtained with scanning and transmission electron microscopies (SEM and TEM). Furthermore, the influence of SWNT addition on the thermal stability of graphite in mixtures of SWNT/graphite at different proportions was investigated. The graphite stability decreased with the increased of SWNT content in the overall range of composition. This behavior could be due to the close contact between these carbonaceous species as determined by SEM analysis.
Resumo:
This paper analyzes the performance of some of the widely used voltage stability indices, namely, singular value, eigenvalue, and loading margin with different static load models. Well-known ZIP model is used to represent loads having components with different power to voltage sensitivities. Studies are carried out on a 10-bus power system and the New England 39-bus power system models. The effects of variation of load model on the performance of the voltage stability indices are discussed. The choice of voltage stability index in the context of load modelling is also suggested in this paper.
Resumo:
In this paper, the stability of an autonomous microgrid with multiple distributed generators (DG) is studied through eigenvalue analysis. It is assumed that all the DGs are connected through Voltage Source Converter (VSC) and all connected loads are passive. The VSCs are controlled by state feedback controller to achieve desired voltage and current outputs that are decided by a droop controller. The state space models of each of the converters with its associated feedback are derived. These are then connected with the state space models of the droop, network and loads to form a homogeneous model, through which the eigenvalues are evaluated. The system stability is then investigated as a function of the droop controller real and reac-tive power coefficients. These observations are then verified through simulation studies using PSCAD/EMTDC. It will be shown that the simulation results closely agree with stability be-havior predicted by the eigenvalue analysis.
Resumo:
This paper presents findings from an Australian study examining the behavioral correlates and stability of social status for preschool-aged children. The social status of an initial sample of 187 (94 boys and 93 girls) preschool children (mean age 62.4 months, SD = 4.22) was determined through sociometric assessment. Children classified as rejected, neglected and popular (n = 70) were selected for observation. Children were observed for a total of 25 minutes over a three-month period engaging in free play within their preschool centers. Results indicated that children classified as popular were more likely than rejected or neglected children to engage in cooperative play, ongoing connected conversation and to display positive affect. Popular children were less likely than rejected or neglected children to engage in parallel play, onlooker behavior or alone directed behavior. Six months after initial sociometric classification, sociometric interviews were repeated to test for stability and change. Results indicated that preschool-aged children’s social status classifications showed a moderate to high rate of stability for those children classified as popular, rejected and neglected.
Resumo:
This article investigates work related learning and development amongst mature aged workers from a lifespan developmental psychology perspective. The current study follows on from research regarding the construction and revision of the Learning and Development Survey (LDS; Tones & Pillay, 2008). Designed to measure adaptive development for work related learning, the revised LDS (R-LDS) encompasses goal selection, engagement and disengagement from individual and organisational perspectives. Previous survey findings from a mixed age sample of local government workers suggest that mature aged workers aged over 45 years are less likely to report engagement in learning and development goals than younger workers, which is partly due to insufficient opportunities at work. In the current paper, exploratory factor analysis was used to investigate responses to the R-LDS amongst two groups of mature aged workers from a local government (LG) and private healthcare (PH) organisation to determine the stability of the R-LDS. Organisational constraints to development accounted for almost a quarter of the variance in R-LDS scores for both samples, while remaining factors emerged in different orders for each data set. Organisational opportunities for development explained about 17% of the variance in R-LDS scores in the LG sample, while the individual goal disengagement factor contributed a comparable proportion of variance to R-LDS scores for the PH sample. Findings from the current study indicate that opportunities for learning and development at work may be age structured and biased towards younger workers. Implications for professional practice are discussed and focus on improving the engagement of mature aged workers.
Resumo:
Investigated the psychometric properties of the original and alternate sets of the Trail Making Test (TMT) and the Controlled Oral Word Association Test (COWAT; A. L. Benton and D. Hamsher, 1978) in 50 orthopedic and 15 closed head injured (1 yr after trauma) patients (aged 15–59 yrs). Although the alternate forms of both measures proved to be stable and consistent with each other in both groups, only the parallel sets of TMT reliably discriminated the clinical group from controls. Practice effects in the head injured were significant only for Trail B of TMT. Factor analysis of the control group's results identified Verbal Knowledge as a major contributor to performance on COWAT, whereas TMT was more dependent on Rapid Visual Search and Visuomotor Sequencing.
Resumo:
In this paper, we consider the variable-order nonlinear fractional diffusion equation View the MathML source where xRα(x,t) is a generalized Riesz fractional derivative of variable order View the MathML source and the nonlinear reaction term f(u,x,t) satisfies the Lipschitz condition |f(u1,x,t)-f(u2,x,t)|less-than-or-equals, slantL|u1-u2|. A new explicit finite-difference approximation is introduced. The convergence and stability of this approximation are proved. Finally, some numerical examples are provided to show that this method is computationally efficient. The proposed method and techniques are applicable to other variable-order nonlinear fractional differential equations.
Resumo:
In this paper, we consider the following non-linear fractional reaction–subdiffusion process (NFR-SubDP): Formula where f(u, x, t) is a linear function of u, the function g(u, x, t) satisfies the Lipschitz condition and 0Dt1–{gamma} is the Riemann–Liouville time fractional partial derivative of order 1 – {gamma}. We propose a new computationally efficient numerical technique to simulate the process. Firstly, the NFR-SubDP is decoupled, which is equivalent to solving a non-linear fractional reaction–subdiffusion equation (NFR-SubDE). Secondly, we propose an implicit numerical method to approximate the NFR-SubDE. Thirdly, the stability and convergence of the method are discussed using a new energy method. Finally, some numerical examples are presented to show the application of the present technique. This method and supporting theoretical results can also be applied to fractional integrodifferential equations.
Resumo:
This paper proposes a method of enhancing system stability with a distribution static compensator (DSTATCOM) in an autonomous microgrid with multiple distributed generators (DG). It is assumed that there are both inertial and non-inertial DGs connected to the microgrid. The inertial DG can be a synchronous machine of smaller rating while inertia less DGs (solar) are assumed as DC sources. The inertia less DGs are connected through Voltage Source Converter (VSC) to the microgrid. The VSCs are controlled by either state feedback or current feedback mode to achieve desired voltage-current or power outputs respectively. The power sharing among the DGs is achieved by drooping voltage angle. Once the reference for the output voltage magnitude and angle is calculated from the droop, state feedback controllers are used to track the reference. The angle reference for the synchronous machine is compared with the output voltage angle of the machine and the error is fed to a PI controller. The controller output is used to set the power reference of the synchronous machine. The rate of change in the angle in a synchronous machine is restricted by the machine inertia and to mimic this nature, the rate of change in the VSCs angles are restricted by a derivative feedback in the droop control. The connected distribution static compensator (DSTATCOM) provides ride through capability during power imbalance in the microgrid, especially when the stored energy of the inertial DG is not sufficient to maintain stability. The inclusion of the DSATCOM in such cases ensures the system stability. The efficacies of the controllers are established through extensive simulation studies using PSCAD.