1000 resultados para Spirometry [methods]
The European Respiratory Society spirometry tent: a unique form of screening for airway obstruction.
Resumo:
In order to raise public awareness of the importance of early detection of airway obstruction and to enable many people who had not been tested previously to have their lung function measured, the European Lung Foundation and the European Respiratory Society (ERS) organised a spirometry testing tent during the annual ERS Congresses in 2004-2009. Spirometry was performed during the ERS Congresses in volunteers; all participants answered a simple, brief questionnaire on their descriptive characteristics, smoking and asthma. Portable spirometers were freely provided by the manufacturer. Nurses and doctors from pulmonary departments of local hospitals/universities gave their service for free. Lower limit of normal (LLN) and Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria for diagnosing and grading airway obstruction were used. Of 12,448 participants in six congress cities, 10,395 (83.5%) performed acceptable spirometry (mean age 51.0 ± 18.4 yrs; 25.5% smokers; 5.5% asthmatic). Airway obstruction was present in 12.4% of investigated subjects according to LLN criteria and 20.3% according to GOLD criteria. Through multinomial logistic regression analysis, age, smoking habits and asthma were significant risk factors for airway obstruction. Relative risk ratio and 95% confidence interval for LLN stage I, for example, was 2.9 (2.0-4.1) for the youngest age (≤ 19 yrs), 1.9 (1.2-3.0) for the oldest age (≥ 80 yrs), 2.4 (2.0-2.9) for current smokers and 2.8 (2.2-3.6) for reported asthma diagnosis. In addition to being a useful advocacy tool, the spirometry tent represents an unusual occasion for early detection of airway obstruction in large numbers of city residents with an important public health perspective.
Resumo:
BackgroundThis is an update of a Cochrane Review first published in The Cochrane Library 2008, Issue 3.Upper abdominal surgical procedures are associated with a high risk of postoperative pulmonary complications. The risk and severity of postoperative pulmonary complications can be reduced by the judicious use of therapeutic manoeuvres that increase lung volume. Our objective was to assess the effect of incentive spirometry compared to no therapy or physiotherapy, including coughing and deep breathing, on all-cause postoperative pulmonary complications andmortality in adult patients admitted to hospital for upper abdominal surgery.ObjectivesOur primary objective was to assess the effect of incentive spirometry (IS), compared to no such therapy or other therapy, on postoperative pulmonary complications and mortality in adults undergoing upper abdominal surgery.Our secondary objectives were to evaluate the effects of IS, compared to no therapy or other therapy, on other postoperative complications, adverse events, and spirometric parameters.Search methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8), MEDLINE, EMBASE, and LILACS (from inception to August 2013). There were no language restrictions. The date of the most recent search was 12 August 2013. The original search was performed in June 2006.Selection criteriaWe included randomized controlled trials (RCTs) of IS in adult patients admitted for any type of upper abdominal surgery, including patients undergoing laparoscopic procedures.Data collection and analysisTwo authors independently assessed trial quality and extracted data.Main resultsWe included 12 studies with a total of 1834 participants in this updated review. The methodological quality of the included studies was difficult to assess as it was poorly reported, so the predominant classification of bias was 'unclear'; the studies did not report on compliance with the prescribed therapy. We were able to include data from only 1160 patients in the meta-analysis. Four trials (152 patients) compared the effects of IS with no respiratory treatment. We found no statistically significant difference between the participants receiving IS and those who had no respiratory treatment for clinical complications (relative risk (RR) 0.59, 95% confidence interval (CI) 0.30 to 1.18). Two trials (194 patients) IS compared incentive spirometry with deep breathing exercises (DBE). We found no statistically significant differences between the participants receiving IS and those receiving DBE in the meta-analysis for respiratory failure (RR 0.67, 95% CI 0.04 to 10.50). Two trials (946 patients) compared IS with other chest physiotherapy. We found no statistically significant differences between the participants receiving IS compared to those receiving physiotherapy in the risk of developing a pulmonary condition or the type of complication. There was no evidence that IS is effective in the prevention of pulmonary complications.Authors' conclusionsThere is low quality evidence regarding the lack of effectiveness of incentive spirometry for prevention of postoperative pulmonary complications in patients after upper abdominal surgery. This review underlines the urgent need to conduct well-designed trials in this field. There is a case for large RCTs with high methodological rigour in order to define any benefit from the use of incentive spirometry regarding mortality.
Resumo:
Background Pulmonary function tests (PFT), particularly spirometry and lung diffusing capacity for carbon monoxide (DL(CO)), have been considered useful methods for the detection of the progression of interstitial asbestos abnormalities as indicated by high-resolution computed tomography (HRCT). However, it is currently unknown which of these two tests correlates best with anatomical changes over time. Methods In this study, we contrasted longitudinal changes (3-9 years follow-up) in PFTs at rest and during exercise with interstitial abnormalities evaluated by HRCT in 63 ex-workers with mild-to-moderate asbestosis. Results At baseline, patients presented with low-grade asbestosis (Huuskonen classes I-II), and most PFT results were within the limits of normality. In the follow-up, most subjects had normal spirometry, static lung volumes and arterial blood gases. In contrast, frequency of DL(CO) abnormalities almost doubled (P < 0.05). Twenty-three (36.5%) subjects increased the interstitial marks on HRCT. These had significantly larger declines in DL(CO) compared to patients who remained stable (0.88 vs. 0.31 ml/min/mm Hg/year and 3.5 vs. 1.2%/year, respectively; P < 0.05). In contrast, no between-group differences were found for the other functional tests, including spirometry (P > 0.05). Conclusions These data demonstrate that the functional consequences of progression of HRCT abnormalities in mild-to-moderate asbestosis are better reflected by decrements in DL(CO) than by spirometric changes. These results might have important practical implications for medico-legal evaluation of this patient population. Am. J. Ind. Med. 54:185-193, 2011. (c) 2010 Wiley-Liss, Inc.
Resumo:
Background: Impairment in pulmonary capacity due to pleural effusion compromises daily activity. Removal of fluid improves symptoms, but the impact, especially on exercise capacity, has not been determined. Methods: Twenty-five patients with unilateral pleural effusion documented by chest radiograph were included. The 6-min walk test, Borg modified dyspnea score, FVC, and FEV, were analyzed before and 48 h after the removal of large pleural effusions. Results: The mean fluid removed was 1,564 +/- 695 mL. After the procedure, values of FVC, FEV and 6-min walk distance increased (P<.001), whereas dyspnea decreased (P<.001). Statistical correlations (P<.001) between 6-min walk distance and FVC (r=0.725) and between 6-min walk distance and FEV, (r=0.661) were observed. Correlations also were observed between the deltas (prethoracentesis X postthoracentesis) of the 6-min walk test and the percentage of FVC (r=0.450) and of FEV, (r=0.472) divided by the volume of fluid removed (P<.05). Conclusion: In addition to the improvement in lung function after thoracentesis, the benefits of fluid removal are more evident in situations of exertion, allowing better readaptation of patients to routine activities. CHEST 2011; 139(6):1424-1429
Resumo:
OBJECTIVES: Age- and height-adjusted spirometric lung function of South Asian children is lower than those of white children. It is unclear whether this is purely genetic, or partly explained by the environment. In this study, we assessed whether cultural factors, socioeconomic status, intrauterine growth, environmental exposures, or a family and personal history of wheeze contribute to explaining the ethnic differences in spirometric lung function. METHODS: We studied children aged 9 to 14 years from a population-based cohort, including 1088 white children and 275 UK-born South Asians. Log-transformed spirometric data were analyzed using multiple linear regressions, adjusting for anthropometric factors. Five different additional models adjusted for (1) cultural factors, (2) indicators of socioeconomic status, (3) perinatal data reflecting intrauterine growth, (4) environmental exposures, and (5) personal and family history of wheeze. RESULTS: Height- and gender-adjusted forced vital capacity (FVC) and forced expired volume in 1 second (FEV1) were lower in South Asian than white children (relative difference -11% and -9% respectively, P < .001), but PEF and FEF50 were similar (P ≥ .5). FEV1/FVC was higher in South Asians (1.8%, P < .001). These differences remained largely unchanged in all 5 alternative models. CONCLUSIONS: Our study confirmed important differences in lung volumes between South Asian and white children. These were not attenuated after adjustment for cultural and socioeconomic factors and intrauterine growth, neither were they explained by differences in environmental exposures nor a personal or family history of wheeze. This suggests that differences in lung function may be mainly genetic in origin. The implication is that ethnicity-specific predicted values remain important specifically for South Asian children.
Resumo:
OBJETIVO: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. MÉTODOS: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. RESULTADOS: Obteve-se as acurácias: tTE - 86%, TC6 - 80%, PTE - 71%, VEF1(L) - 67%, VEF1% - 63%. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5% e em série, especificidade de 96,4%. CONCLUSÃO: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100%. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.
Resumo:
OBJECTIVES Age- and height-adjusted spirometric lung function of South Asian children is lower than those of white children. It is unclear whether this is purely genetic, or partly explained by the environment. In this study, we assessed whether cultural factors, socioeconomic status, intrauterine growth, environmental exposures, or a family and personal history of wheeze contribute to explaining the ethnic differences in spirometric lung function. METHODS We studied children aged 9 to 14 years from a population-based cohort, including 1088 white children and 275 UK-born South Asians. Log-transformed spirometric data were analyzed using multiple linear regressions, adjusting for anthropometric factors. Five different additional models adjusted for (1) cultural factors, (2) indicators of socioeconomic status, (3) perinatal data reflecting intrauterine growth, (4) environmental exposures, and (5) personal and family history of wheeze. RESULTS Height- and gender-adjusted forced vital capacity (FVC) and forced expired volume in 1 second (FEV1) were lower in South Asian than white children (relative difference -11% and -9% respectively, P < .001), but PEF and FEF50 were similar (P ≥ .5). FEV1/FVC was higher in South Asians (1.8%, P < .001). These differences remained largely unchanged in all 5 alternative models. CONCLUSIONS Our study confirmed important differences in lung volumes between South Asian and white children. These were not attenuated after adjustment for cultural and socioeconomic factors and intrauterine growth, neither were they explained by differences in environmental exposures nor a personal or family history of wheeze. This suggests that differences in lung function may be mainly genetic in origin. The implication is that ethnicity-specific predicted values remain important specifically for South Asian children.
Resumo:
METHODS Spirometry datasets from South-Asian children were collated from four centres in India and five within the UK. Records with transcription errors, missing values for height or spirometry, and implausible values were excluded(n = 110). RESULTS Following exclusions, cross-sectional data were available from 8,124 children (56.3% male; 5-17 years). When compared with GLI-predicted values from White Europeans, forced expired volume in 1s (FEV1) and forced vital capacity (FVC) in South-Asian children were on average 15% lower, ranging from 4-19% between centres. By contrast, proportional reductions in FEV1 and FVC within all but two datasets meant that the FEV1/FVC ratio remained independent of ethnicity. The 'GLI-Other' equation fitted data from North India reasonably well while 'GLI-Black' equations provided a better approximation for South-Asian data than the 'GLI-White' equation. However, marked discrepancies in the mean lung function z-scores between centres especially when examined according to socio-economic conditions precluded derivation of a single South-Asian GLI-adjustment. CONCLUSION Until improved and more robust prediction equations can be derived, we recommend the use of 'GLI-Black' equations for interpreting most South-Asian data, although 'GLI-Other' may be more appropriate for North Indian data. Prospective data collection using standardised protocols to explore potential sources of variation due to socio-economic circumstances, secular changes in growth/predictors of lung function and ethnicities within the South-Asian classification are urgently required.
Resumo:
The aim of this clinical study was to determine the efficacy of Uncaria tomentosa (cat's claw) against denture stomatitis (DS). Fifty patients with DS were randomly assigned into 3 groups to receive 2% miconazole, placebo, or 2% U tomentosa gel. DS level was recorded immediately, after 1 week of treatment, and 1 week after treatment. The clinical effectiveness of each treatment was measured using Newton's criteria. Mycologic samples from palatal mucosa and prosthesis were obtained to determinate colony forming units per milliliter (CFU/mL) and fungal identification at each evaluation period. Candida species were identified with HiCrome Candida and API 20C AUX biochemical test. DS severity decreased in all groups (P < .05). A significant reduction in number of CFU/mL after 1 week (P < .05) was observed for all groups and remained after 14 days (P > .05). C albicans was the most prevalent microorganism before treatment, followed by C tropicalis, C glabrata, and C krusei, regardless of the group and time evaluated. U tomentosa gel had the same effect as 2% miconazole gel. U tomentosa gel is an effective topical adjuvant treatment for denture stomatitis.
Resumo:
Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.
Resumo:
What is the contribution of the provision, at no cost for users, of long acting reversible contraceptive methods (LARC; copper intrauterine device [IUD], the levonorgestrel-releasing intrauterine system [LNG-IUS], contraceptive implants and depot-medroxyprogesterone [DMPA] injection) towards the disability-adjusted life years (DALY) averted through a Brazilian university-based clinic established over 30 years ago. Over the last 10 years of evaluation, provision of LARC methods and DMPA by the clinic are estimated to have contributed to DALY averted by between 37 and 60 maternal deaths, 315-424 child mortalities, 634-853 combined maternal morbidity and mortality and child mortality, and 1056-1412 unsafe abortions averted. LARC methods are associated with a high contraceptive effectiveness when compared with contraceptive methods which need frequent attention; perhaps because LARC methods are independent of individual or couple compliance. However, in general previous studies have evaluated contraceptive methods during clinical studies over a short period of time, or not more than 10 years. Furthermore, information regarding the estimation of the DALY averted is scarce. We reviewed 50 004 medical charts from women who consulted for the first time looking for a contraceptive method over the period from 2 January 1980 through 31 December 2012. Women who consulted at the Department of Obstetrics and Gynaecology, University of Campinas, Brazil were new users and users switching contraceptive, including the copper IUD (n = 13 826), the LNG-IUS (n = 1525), implants (n = 277) and DMPA (n = 9387). Estimation of the DALY averted included maternal morbidity and mortality, child mortality and unsafe abortions averted. We obtained 29 416 contraceptive segments of use including 25 009 contraceptive segments of use from 20 821 new users or switchers to any LARC method or DMPA with at least 1 year of follow-up. The mean (± SD) age of the women at first consultation ranged from 25.3 ± 5.7 (range 12-47) years in the 1980s, to 31.9 ± 7.4 (range 16-50) years in 2010-2011. The most common contraceptive chosen at the first consultation was copper IUD (48.3, 74.5 and 64.7% in the 1980s, 1990s and 2000s, respectively). For an evaluation over 20 years, the cumulative pregnancy rates (SEM) were 0.4 (0.2), 2.8 (2.1), 4.0 (0.4) and 1.3 (0.4) for the LNG-IUS, the implants, copper IUD and DMPA, respectively and cumulative continuation rates (SEM) were 15.1 (3.7), 3.9 (1.4), 14.1 (0.6) and 7.3 (1.7) for the LNG-IUS, implants, copper IUD and DMPA, respectively (P < 0.001). Over the last 10 years of evaluation, the estimation of the contribution of the clinic through the provision of LARC methods and DMPA to DALY averted was 37-60 maternal deaths; between 315 and 424 child mortalities; combined maternal morbidity and mortality and child mortality of between 634 and 853, and 1056-1412 unsafe abortions averted. The main limitations are the number of women who never returned to the clinic (overall 14% among the four methods under evaluation); consequently the pregnancy rate could be different. Other limitations include the analysis of two kinds of copper IUD and two kinds of contraceptive implants as the same IUD or implant, and the low number of users of implants. In addition, the DALY calculation relies on a number of estimates, which may vary in different parts of the world. LARC methods and DMPA are highly effective and women who were well-counselled used these methods for a long time. The benefit of averting maternal morbidity and mortality, child mortality, and unsafe abortions is an example to health policy makers to implement more family planning programmes and to offer contraceptive methods, mainly LARC and DMPA, at no cost or at affordable cost for the underprivileged population. This study received partial financial support from the Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP), grant # 2012/12810-4 and from the National Research Council (CNPq), grant #573747/2008-3. B.F.B., M.P.G., and V.M.C. were fellows from the scientific initiation programme from FAPESP. Since the year 2001, all the TCu380A IUD were donated by Injeflex, São Paulo, Brazil, and from the year 2006 all the LNG-IUS were donated by the International Contraceptive Access Foundation (ICA), Turku, Finland. Both donations are as unrestricted grants. The authors declare that there are no conflicts of interest associated with this study.
Resumo:
The microabrasion technique of enamel consists of selectively abrading the discolored areas or causing superficial structural changes in a selective way. In microabrasion technique, abrasive products associated with acids are used, and the evaluation of enamel roughness after this treatment, as well as surface polishing, is necessary. This in-vitro study evaluated the enamel roughness after microabrasion, followed by different polishing techniques. Roughness analyses were performed before microabrasion (L1), after microabrasion (L2), and after polishing (L3).Thus, 60 bovine incisive teeth divided into two groups were selected (n=30): G1- 37% phosphoric acid (37%) (Dentsply) and pumice; G2- hydrochloric acid (6.6%) associated with silicon carbide (Opalustre - Ultradent). Thereafter, the groups were divided into three sub-groups (n=10), according to the system of polishing: A - Fine and superfine granulation aluminum oxide discs (SofLex 3M); B - Diamond Paste (FGM) associated with felt discs (FGM); C - Silicone tips (Enhance - Dentsply). A PROC MIXED procedure was applied after data exploratory analysis, as well as the Tukey-Kramer test (5%). No statistical differences were found between G1 and G2 groups. L2 differed statistically from L1 and showed superior amounts of roughness. Differences in the amounts of post-polishing roughness for specific groups (1A, 2B, and 1C) arose, which demonstrated less roughness in L3 and differed statistically from L2 in the polishing system. All products increased enamel roughness, and the effectiveness of the polishing systems was dependent upon the abrasive used.
Resumo:
Silk fibroin has been widely explored for many biomedical applications, due to its biocompatibility and biodegradability. Sterilization is a fundamental step in biomaterials processing and it must not jeopardize the functionality of medical devices. The aim of this study was to analyze the influence of different sterilization methods in the physical, chemical, and biological characteristics of dense and porous silk fibroin membranes. Silk fibroin membranes were treated by several procedures: immersion in 70% ethanol solution, ultraviolet radiation, autoclave, ethylene oxide, and gamma radiation, and were analyzed by scanning electron microscopy, Fourier-transformed infrared spectroscopy (FTIR), X-ray diffraction, tensile strength and in vitro cytotoxicity to Chinese hamster ovary cells. The results indicated that the sterilization methods did not cause perceivable morphological changes in the membranes and the membranes were not toxic to cells. The sterilization methods that used organic solvent or an increased humidity and/or temperature (70% ethanol, autoclave, and ethylene oxide) increased the silk II content in the membranes: the dense membranes became more brittle, while the porous membranes showed increased strength at break. Membranes that underwent sterilization by UV and gamma radiation presented properties similar to the nonsterilized membranes, mainly for tensile strength and FTIR results.
Resumo:
Frankfurters are widely consumed all over the world, and the production requires a wide range of meat and non-meat ingredients. Due to these characteristics, frankfurters are products that can be easily adulterated with lower value meats, and the presence of undeclared species. Adulterations are often still difficult to detect, due the fact that the adulterant components are usually very similar to the authentic product. In this work, FT-Raman spectroscopy was employed as a rapid technique for assessing the quality of frankfurters. Based on information provided by the Raman spectra, a multivariate classification model was developed to identify the frankfurter type. The aim was to study three types of frankfurters (chicken, turkey and mixed meat) according to their Raman spectra, based on the fatty vibrational bands. Classification model was built using partial least square discriminant analysis (PLS-DA) and the performance model was evaluated in terms of sensitivity, specificity, accuracy, efficiency and Matthews's correlation coefficient. The PLS-DA models give sensitivity and specificity values on the test set in the ranges of 88%-100%, showing good performance of the classification models. The work shows the Raman spectroscopy with chemometric tools can be used as an analytical tool in quality control of frankfurters.
Resumo:
The aim of the present study was to compare four methods of fixation in mandibular body fractures. Mechanical and photoelastic tests were performed using polyurethane and photoelastic resin mandibles, respectively. The study groups contained the following: (I), two miniplates of 2.0 mm; (II) one 2.0 mm plate and an Erich arch bar; (III) one 2.4 mm plate and an Erich arch bar, and (IV) one 2.0 mm plate and one 2.4 mm plate. The differences between the mean values were analyzed using Tukey's test, the Mann-Whitney test and the Bonferroni correction. Group II recorded the lowest resistance, followed by groups I, IV and III. The photoelastic test confirmed the increase of tension in group II. The 2.4 mm system board in linear mandibular body fractures provided more resistance and the use of only one 2.0 mm plate in the central area of the mandible created higher tension.