995 resultados para Specular microscopy


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background - The study of corneal endothelium, by specular microscopy, in patients with anterior uveitis has largely been restricted to observations on the endothelial cells. In this prospective study 'keratic precipitates' (KP) in different types of uveitis were examined in different stages of the disease process and the endothelial changes occurring in the vicinity of the KP were evaluated in comparison with the endothelium of the uninvolved eye. Methods - 13 patients with active unilateral uveitis were recruited. The mean age was 42.9 years (range 20-76 years). A Tomey-1100 contact wide field specular (x10) microscope was used to capture endothelial images and KP until the resolution of uveitis. Data regarding type of uveitis, number, size, and nature of KP were recorded. Automated morphometric analysis was done for cell size, cell density and coefficient of variation, and statistical comparisons of cell size and cell density were made (Student's t test) between the endothelium in the vicinity of fresh and resolving KP, fresh KP and normal endothelium, and resolving KP and normal endothelium. Results - On specular microscopy, fresh KP were seen as dense, white glistening deposits occupying 5-10 endothelial cells in diameter and fine KP were widely distributed and were one or two endothelial cells in diameter. The KP in Posner-Schlossman syndrome had a distinct and different morphology. With clinical remission of uveitis, the KP were observed to undergo characteristic morphological changes and old KP demonstrated a large, dark halo surrounding a central white deposit and occasionally a dark shadow or a 'lacuna' replaced the site of the original KP. Endothelial blebs were noted as dark shadows or defects in the endothelial mosaic in patients with recurrent uveitis. There was significant statistical difference in the mean cell size and cell density of endothelial cells in the vicinity of fresh KP compared with normal endothelium of the opposite eye. Conclusion - This study elucidated the different specular microscopic features of KP in anterior uveitis. Distinct morphological features of large and fine KP were noted. These features underwent dramatic changes on resolution of uveitis. The endothelium was abnormal in the vicinity of KP, which returned to near normal values on resolution of uveitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foram estudados 20 olhos de 10 cães sem raça definida, machos e fêmeas com 6 anos de idade. A morfologia das células do endotélio da córnea foi analisada utilizando-se microscópio especular de contato. Foram estudadas as regiões central e periférica da córnea. de cada região da córnea foram realizadas três micrografias. de cada micrografia foram analisadas no mínimo 100 células endoteliais. Foram obtidos os valores do polimegatismo e pleomorfismo. O endotélio corneano de cães caracterizou-se por uma monocamada de células poligonais uniformes em tamanho e forma. A forma predominante das células endoteliais foi hexagonal. O índice de polimegatismo foi 0.22. Este estudo demonstrou que a morfologia das células do endotélio da córnea de cães é semelhante à observada em humanos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effect of age on endothelial morphology and morphometry in cats. The corneal endothelium was studied using a contact specular microscope. A total of 18 cats (Felis catus Linnaeus, 1758) were evaluated in this study. The subjects were divided into three groups of six cats each in function of age: G1 (1 to 3 months old), G2 (5 to 12 months old), and G3 (24 to 40 months old). The examination presented data as endothelial cell density (ECD), average cell area, corneal thickness, polymegathism, and pleomorphism. Results revealed ECD decrease in corneas of normal cats with age, as well as a corresponding increase in endothelial cell area and pleomorphism. The present work suggests that the endothelial parameters evaluated change with advancing age.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to evaluate and correlate intraocular pressure (IOP), endothelial cell density (CD), and hexagonality (HEX), and the aqueous humor prostaglandin E-2 (PGE(2)) concentration in dogs with mature (MG, n = 8) and hypermature (HG, n = 8) cataracts. Eight laboratory beagles with no ocular abnormalities were included as a control group (CG). The IOP was measured using a digital applanation tonometer. Noncontact specular microscopy was used to evaluate CD and HEX. Samples of aqueous humor were used to determine prostaglandin E-2 concentration using enzyme-linked immunoassay. Data were compared by ANOVA and Bonferroni's multiple comparison test, and possible correlations among the PGE(2) aqueous concentration and corneal endothelium cell parameters were assessed by Person's test (P < 0.05). Average values of IOP (P = 0.45) and CD (P = 0.39) were not significantly different between MG, HM, and CG. Average values of HEX were lower, and PGE(2) concentration was increased in the MG and HG in comparison with CG (P < 0.05); however, such parameters did not change significantly between MG and HG (P > 0.05). PGE(2) values did not correlate with IOP, CD, and HEX in any group (P > 0.05). Although there were a small number of dogs studied, our results demonstrated that cataract progression from mature to hypermature did not have a significant change in PGE(2) aqueous concentration, IOP, corneal endothelial cell count, or morphology. In addition, PGE(2) concentration was not correlated with parameters of the corneal endothelium or IOP in dogs with mature or hypermature cataracts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. Methods: One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab(US Patent). A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE<0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Results: Bio-Optics: sample size, 97 +/- 22 cells; RE, 6.52 +/- 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 162 +/- 34 cells. CSO: sample size, 110 +/- 20 cells; RE, 5.98 +/- 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 157 +/- 45 cells. Konan: sample size, 80 +/- 27 cells; RE, 10.6 +/- 3.67; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 336 +/- 131 cells. Topcon: sample size, 87 +/- 17 cells; RE, 10.1 +/- 2.52; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 382 +/- 159 cells. Conclusions: A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose. To describe endothelial changes associated with emulsified silicone oil. Methods. Report of a case. Results. A 77-year-old man had multiple and diffuse clear vesicles on the endothelium of his left eye (LE). The cornea was clear and thin. He had undergone pars plana vitrectomy and intraocular silicone oil injection 5 years before presentation. Specular microscopy revealed numerous small bubbles of emulsified silicone oil and a mild degree of endothelial damage. Conclusion. Emulsified silicone oil can adhere to the endothelium and induce an apparent droplet-like endotheliopathy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Corneal endothelial cells from normal and traumatized human, primate, cat and rabbit eyes were studied by specular microscopy. Morphometric analysis was performed on micrographs of corneal endothelium using a semi-automated image analysis system. The results showed that under normal conditions the corneal endothelium of all four species exhibit major morphological similarities (mean cell areas: human 317 +/- 32 microns 2, primate 246 +/- 22 microns2, cat 357 +/- 25 microns 2, rabbit 308 +/- 35 microns 2). The normal corneal endothelium in man was found to be more polymegethous than that of the other species. Trauma to cat, primate and human corneas resulted in a long-term reduction in endothelial cell density and enhanced polymegethism. In contrast, the reparative response of the rabbit ensured the reformation of an essentially normal monolayer following injury. Endothelial giant cells were a normal inclusion in the rabbit corneal endothelium but were only significant in cat, primate and man following trauma. The presence of corneal endothelial giant cells in amitotic corneas may therefore represent a compensatory response in the absence of mitotic potential.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O endotélio corneal é uma monocamada de células poligonais. A integridade e saúde dessa camada são essenciais para a manutenção da transparência corneal normal. Este estudo reportou pela primeira vez, de forma detalhada, a morfologia ultra-estrutural e a morfometria do endotélio corneal de suínos adultos mestiços à microscopia eletrônica de varredura (MEV). A superfície endothelial corneal apresentou um padrão regular de células poligonais, com predomínio da forma hexagonal e de bordas celulares nítidas. O núcleo foi observado como protuberância arredondada no centro da célula. Também foram observados os cílios (2-4) em apenas algumas células da região periférica da córnea, as aberturas das vesículas pinocitóticas na proximidade dos cílios, as microvilosidades, as varas da borda e as bordas celulares em formato de zigzag. A área celular média foi significativamente maior (P<0,05) no centro da córnea do que na periferia, com um coeficiente de variação menor no centro da córnea. A densidade celular média foi significativamente maior na periferia (P<0,05) e 43,9% maior que os dados reportados por outros autores na microscopia especular, o que demonstra o efeito da retração celular durante o processamento das amostras. O valor médio do número de lados das células (pleomorfismo) foi de 5,9, o que evidencia um predomínio do formato hexagonal. A percentagem de células hexagonais foi significativamente maior no centro (P<0,001). Os parâmetros obtidos nesta pesquisa servirão de base para estudos futuros sobre o efeito de medicamentos, cirurgias intracamerulares ou soluções para armazenamento de córneas para transplantes no endotélio corneal do suíno.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Avaliaram-se as células endoteliais, a espessura corneana e a pressão intraocular (PIO) de cães portadores de catarata madura, empregando-se viscoelástico à base de hialuronato de sódio 3% e sulfato de condroitina 4% e hidroxipropilmetilcelulose 2%, utilizando-se 20 cães, distribuídos entre os dois grupos dos viscoelásticos. A técnica cirúrgica adotada foi a da facoemulsificação bimanual. As avaliações tonométricas foram efetuadas antes e após o ato cirúrgico, aos 1, 7, 14, 21, 28 e 60 dias de pós-operatório, e a microscopia especular, antes e após 7, 28 e 60 dias. Não houve diferença estatística entre os grupos quanto à PIO, com exceção aos 14 dias, em que se observou maior PIO com o uso de hialuronato de sódio 3% e sulfato de condroitina 4%. Não houve diferença entre os grupos quanto aos parâmetros relacionados ao endotélio, com diminuição discreta da densidade celular endotelial e aumento da área celular com a utilização de hidroxipropilmetilcelulose 2%. A utilização de ambos os dispositivos viscoelásticos analisados é recomendada para o procedimento de facoemulsificação em cães.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to examine the endothelial surface and to perform a morphometric analysis of the corneal endothelial cells in normal eyes of dogs using specular microscopy. Morphometric analysis with regard mean cell area and cell density was performed. Both eyes of ten mixed-breed, males and females, with 6 years of age, weighing about 15 kg euthanatized for reasons unrelated to this study were evaluated. Eyes were examined to determine that they did not have visible ocular disease and transported to the laboratory in moist chamber. Using a contact specular microscope the corneal endothelium was examined. Three images of the central corneal endothelium of each eye were obtained. The mean cell area and the cell density of the corneal endothelial cells were obtained using software for corneal endothelium analysis and density measurement. The mean cell area was 395 ± 36 μm 2 and the endothelial cell density was 2555 ± 240 cells/mm2. The present work demonstrates that the normal corneal endothelium of dog is similar to those described in human.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV