995 resultados para Spectrally-resolved fluorescence decays


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resonance energy transfer (RET) from the visible emission of core−shell ZnO:MgO nanocrystals to Nile Red chromophores, following band gap excitation in the UV, has been investigated for four different nanocrystal sizes. With use of steady state and time-resolved fluorescence spectroscopic measurements the wavelength dependent RET efficiencies have been determined. The RET process in ZnO:MgO nanocrystals occurs from emissions involving trap state recombination. There are two such processes with different RET efficiencies for the same particle size. This is shown to be a consequence of the fact that the recombination processes giving rise to the two emissions are located at different distances from the center of the particle so that the donor−acceptor distances for the two are different, even for the same particle size.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-resolved fluorescence studies were carried out on a series of free-base and zinc(II) derivatives of meso-tetraphenylporphyrins covalently linked to either 1,3-dinitrobenzene (DNB) or 1,3,5-trinitrobenzene (TNB) acceptor units. These acceptor units were linked at different sites (at the ortho, meta or para positions of one of the phenyl groups of meso-tetraphenylporphyrin) to the donor porphyrins such that the resulting isomeric intramolecular donor-acceptor complexes exhibit different centre-to-centre (ctc) distances and relative orientations. Biexponential fluorescence decay profiles observed for several of these covalently linked complexes were rationalized in terms of the presence of ''closed'' and ''extended'' conformers. Detailed analyses of the fluorescence decay data have provided a comprehensive understanding of the photoinduced electron transfer (PET) reactions occurring in systems containing zinc(II) porphyrin donors. It is observed that although DNB-linked zinc(II) complexes follow the trends predicted for the efficiency of PET with respect to donor-acceptor distance, the TNB-linked zinc(II) porphyrins exhibit a behaviour which is dictated by steric effects. Similarly, although the thermodynamic criteria predict a greater efficiency of charge separation in TNB-linked complexes compared with DNB-linked complexes, the reverse trend observed has been attributed to orientational effects. In the complexes containing free-base porphyrin donors, PET is expected to be less efficient from a thermodynamic viewpoint. In a few of these cases, fluorescence quenching seems to occur by parallel mechanisms other than PET.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal resistance and thermal rise-time are two basic parameters that affect most of the performances of a laser diode greatly. By measuring waveforms received after a spectroscope at wavelengths varied step-by-step, the spectrally resolved waveforms can be converted to calculate the thermal rise-time. Basic formulas for the spectrum variation of a laser diode and the measurement set-up by using a Boxcar are described in the paper. As an example, the thermal rise-time of a p-side up packaged short-pulse laser diode was measured by the method to be 390 mu s. The method will be useful in characterizing diode lasers and LID modules in high-power applications. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: A time-resolved fluorescence immunoassay (TRFIA), based on anti-microcystin-LR (MCLR) monoclonal antibodies (MAbs) and europium-labeled antimouse IgG conjugate, was first developed for microcystin detection. Methods: Anti-MCLR MAbs were prepared by a standard method, and the attained MAbs showed a good cross reactivity with MCLR, MCRR and MCYR. The TRFIA was performed in an indirect competitive mode. The detection method of TRFIA was compared with indirect competitive enzyme-linked immunosorbent assay (ELISA) and high-performance liquid chromatography (HPLC). Results: The TRFIA exhibited a typical sigmoidal response for MCLR at concentrations of 0.005-50 ng/ml, with a wide quantitative range between 0.01 and 10 ng/ml, indicating the broadest detective range and the most sensitive of all the methods for microcystins (MCs) detection. Additionally, the TRFIA maintained good reliability through its quantitative range, as evidenced by low coefficients of variation (1.6-12.2%). The toxin data of algal samples assayed from TRFIA were in the same range as those with ELISA and HPLC, implying that the method was reliable and practical for the detection of MCs. Conclusions: The TRFIA may offer a valuable alternative or a substitute for conventional ELISA for microcystin detection. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we report on a solid phase time-resolved fluorescence immunoassay chelate reagent-4,7-bis(chlorosulfophenyl)1, 10-phenanthroline-2,9-dicarboxylic acid (BCPDA), which is suitable as a fluorescent labeling agent. The five step synthesis product of BCPDA was presented for improving the purity of the product based on the three step synthesis product. The approach involves chlorization, hydrolyzing the ester, preparing disodium, carboxylate to diacid, sulfonation. The yield of five step product is 99 %, 45 %, 94 %, 95 %, 80 % respectively. The structure and purity of product was characterized by the melting point, IR,H-1 NMR, UV spectrum, element analysis, and proved to be consistent with the structure predictal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper described a laser-excited time-resolved fluoroimmunoassay set. It made lanthanide ion to couple the anhydrde of diethylenetriaminepentaacetic acid (DTPAA) for labeling antibodies. The experiment used polystyrene tap coated with HCV antigen as the solid phase and a chelate of the rare earth metal europium as fluorescent label. A nitrogen laser beam was used to excite the Eu3+ chelates and after 60 ys delay time,the emission fluorescence was measured. Background fluorescence of short lifetimes caused by serum components and Raman scattering can be eliminated by set the delay rime. In the system condition, fluorescent spectra and fluorescent lifetimes of Eu3+ beta-naphthoyltrifluroacetone (NTA) chelates were measured. The fluorescent lifetime value is 650 mu s. The maximum emssion wavelength is 613 nm. The linear range of europium ion concentration is 1 x 10(-7)- 1 x 10(-11) g.mL(-1) and the detection limit is 1 x 10(-13) g.mL(-1). The relative standard deviation of determination ( n = 12) for samples at 0.01 ng.mL(-1) magnitude is 6.4%. Laser-TRFIA was also found to be suitable for diagnosis of HCV. The sensitvity and specificity were comparable to enzyme immunoassay. The result was obtained with laser-TRFIA for 29 human correlated well with enzyme immunoassay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complexation of acenaphthene and fluoranthene with beta-cyclodextrin (CD) in aqueous solutions in the presence and absence of ethanol was investigated by means of the time-resolved fluorescence technique. The appearance of a longer lifetime component and the increase of its fraction relative to that of the shorter lifetime component with increasing CD concentration demonstrate the formation of inclusion complex between the guest molecule and CD. The formation constants for complexation were derived from the pre-exponential factor A(i) of fluorescence decay curves. The presence of ethanol in the reaction systems enhanced the inclusion to a large extent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel wide angle spectrometer has been implemented with a highly oriented pyrolytic graphite crystal coupled to an image plate. This spectrometer has allowed us to look at the energy resolved spectrum of scattered x rays from a dense plasma over a wide range of angles ( ~ 30°) in a single shot. Using this spectrometer we were able to observe the temporal evolution of the angular scatter cross section from a laser shocked foil. A spectrometer of this type may also be useful in investigations of x-ray line transfer from laser-plasmas experiments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A quantitative duplex time-resolved fluorescence assay, dissociation-enhanced lanthanide fluorescent immunoassay (DELFIA), was developed to measure Norwalk virus (NV)-specific IgA and IgG antibodies simultaneously. The duplex assay showed superior performance by detecting seroconversion following experimental NV infection at an earlier time point than a reference total immunoglobulin enzyme-linked immunosorbent assay (ELISA).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have resolved the solid-liquid phase transition of carbon at pressures around 150GPa. High-pressure samples of different temperatures were created by laser-driven shock compression of graphite and varying the initial density from 1.30g/cm3 to 2.25g/cm3. In this way, temperatures from 5700K to 14,500K could be achieved for relatively constant pressure according to hydrodynamic simulations. From measuring the elastic X-ray scattering intensity of vanadium K-alpha radiation at 4.95keVat a scattering angle of 126°, which is very sensitive to the solid-liquid transition, we can determine whether the sample had transitioned to the fluid phase. We find that samples of initial density 1.3g/cm3 and 1.85g/cm3 are liquid in the compressed states, whereas samples close to the ideal graphite crystal density of 2.25g/cm3 remain solid, probably in a diamond-like state.