860 resultados para Socialisation and performance assessment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper describes a model for a 6-phase induction motor driven by an inverter operating in a 6-pulse (square wave) mode. The model is implemented and performance, in terms of torque, current, efficiency and pulsating torque, compared to the performance of a 3-phase motor (both sine and 6-pulse supplied). The models are verified experimentally, in particular the efficiency performance, and it is illustrated that the improvement in inverter efficiency when in 6-pulse operating mode may improve the performance of the overall system. © 2005 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction : Décrire les patients d'une structure gériatrique offrant des hospitalisations de courte durée, dans un contexte ambulatoire, pour des situations gériatriques courantes dans le canton de Genève (Suisse). Mesurer les performances de cette structure en termes de qualité des soins et de coûts. Méthodes : Des données relatives au profil des 100 premiers patients ont été collectées (huit mois), ainsi qu'aux prestations, aux ressources et aux effets (réadmissions, décès, satisfaction, complications) de manière à mesurer différents indicateurs de qualité et de coûts. Les valeurs observées ont été systématiquement comparées aux valeurs attendues, calculées à partir du profil des patients. Résultats : Des critères d'admission ont été fixés pour exclure les situations dans lesquelles d'autres structures offrent des soins mieux adaptés. La spécificité de cette structure intermédiaire a été d'assurer une continuité des soins et d'organiser d'emblée le retour à domicile par des prestations de liaison ambulatoire. La faible occurrence des réadmissions potentiellement évitables, une bonne satisfaction des patients, l'absence de décès prématurés et le faible nombre de complications suggèrent que les soins médicaux et infirmiers ont été délivrés avec une bonne qualité. Le coût s'est révélé nettement plus économique que des séjours hospitaliers après ajustement pour la lourdeur des cas. Conclusion : L'expérience-pilote a démontré la faisabilité et l'utilité d'une unité d'hébergement et d'hospitalisation de court séjour en toute sécurité. Le suivi du patient par le médecin traitant assure une continuité des soins et évite la perte d'information lors des transitions ainsi que les examens non pertinents. INTRODUCTION: To describe patients admitted to a geriatric institution, providing short-term hospitalizations in the context of ambulatory care in the canton of Geneva. To measure the performances of this structure in terms of quality ofcare and costs. METHOD: Data related to the clinical,functioning and participation profiles of the first 100 patients were collected. Data related to effects (readmission, deaths, satisfaction, complications), services and resources were also documented over an 8-month period to measure various quality and costindicators. Observed values were systematically compared to expected values, adjusted for case mix. RESULTS: Explicit criteria were proposed to focus on the suitable patients, excluding situations in which other structures were considered to be more appropriate. The specificity of this intermediate structure was to immediately organize, upon discharge, outpatient services at home. The low rate of potentially avoidable readmissions, the high patient satisfaction scores, the absence of premature death and the low number of iatrogenic complications suggest that medical and nursing care delivered reflect a good quality of services. The cost was significantly lower than expected, after adjusting for case mix. CONCLUSION: The pilot experience showed that a short-stay hospitalization unit was feasible with acceptable security conditions. The attending physician's knowledge of the patients allowed this system tofocus on essential issues without proposing inappropriate services.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Plasma Focus is a device designed to generate a plasma sheet between two coaxial electrodes by means of a high voltage difference. The plasma is then driven to collapse into a “pinch”, where thermonuclear conditions prevail. During the “pinch phase” charged particles are emitted, with two main components: an ion beam peaked forward and an electron beam directed backward. The electron beam emitted backward by Plasma Focus devices is being investigated as a radiation source for medical applications, using it to produce x-rays by interaction with appropriate targets (through bremsstrahlung and characteristic emission). A dedicated Plasma Focus device, named PFMA-3 (Plasma Focus for Medical Applications number 3), has been designed, put in operation and tested by the research groups of the Universities of Bologna and Ferrara. The very high dose rate (several gray per discharge, in less than 1 µs) is a peculiarity of this device that has to be investigated, as it might modify the relative biological effectiveness (RBE). Aim of this Ph.D. project was to investigate the main physical properties of the low-energy x-ray beams produced by a Plasma Focus device and their potential medical applications to IORT treatments. It was necessary to develop the optimal geometrical configuration; to evaluate the x-rays produced and their dose deposited; to estimate the energy electron spectrum produced in the “pinch phase”; to study an optimal target for the conversion of the x-rays; to conduct simulations to study the physics involved; and in order to evaluate the radio-biological features of the beam, cell holders had to be developed for both irradiations and cell growth conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current artificial heart valves are classified as mechanical and bioprosthetic. An appealing pathway that promises to overcome the shortcomings of commercially available heart valves is offered by the interdisciplinary approach of cardiovascular tissue engineering. However, the mechanical properties of the Tissue Engineering Heart Valves (TEHV) are limited and generally fail in the long-term use. To meet this performance challenge novel biodegradable triblock copolymer poly(ethylene oxide)-polypropylene oxide)-poly(ethylene oxide) (PEO-PPO-PEO or F108) crosslinked to Silk Fibroin (F108-SilkC) to be used as tri-leaflet heart valve material was investigated. ^ Synthesis of ten polymers with varying concentration and thickness (55 µm, 75 µm and 100 µm) was achieved via a covalent crosslinking scheme using bifunctional polyethylene glycol diglycidyl ether (PEGDE). Static and fatigue testing were used to assess mechanical properties of films, and hydrodynamic testing was performed to determine performance under a simulated left ventricular flow regime. The crosslinked copolymer (F108-Silk C) showed greater flexibility and resilience, but inferior ultimate tensile strength, by increasing concentration of PEGDE. Concentration molar ratio of 80:1 (F108: Silk) and thickness of 75 µm showed longer fatigue life for both tension-tension and bending fatigue tests. Four valves out of twelve designed satisfactorily complied with minimum performance requirement ISO 5840, 2005. ^ In conclusion, it was demonstrated that the applicability of a degradable polymer in conjugation with silk fibroin for tissue engineering cardiovascular use, specifically for aortic valve leaflet design, met the performance demands. Thinner thicknesses (t<75 µm) in conjunction with stiffness lower than 320 MPa (80:1, F108: Silk) are essential for the correct functionality of proposed heart valve biomaterial F108-SilkC. Fatigue tests were demonstrated to be a useful tool to characterize biomaterials that undergo cyclic loading. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de Mestrado, Gestão de Recursos Humanos, Escola Superior de Gestão, Hotelaria e Turismo, Faculdade de Ciências Humanas e Sociais, Universidade do Algarve, 2016

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current research in secure messaging for Vehicular Ad hoc Networks (VANETs) appears to focus on employing a digital certificate-based Public Key Cryptosystem (PKC) to support security. The security overhead of such a scheme, however, creates a transmission delay and introduces a time-consuming verification process to VANET communications. This paper proposes a non-certificate-based public key management for VANETs. A comprehensive evaluation of performance and scalability of the proposed public key management regime is presented, which is compared to a certificate-based PKC by employing a number of quantified analyses and simulations. Not only does this paper demonstrate that the proposal can maintain security, but it also asserts that it can improve overall performance and scalability at a lower cost, compared to the certificate-based PKC. It is believed that the proposed scheme will add a new dimension to the key management and verification services for VANETs.