858 resultados para Skull fracture


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Scanning electronmicroscopy (SEM) has been used in forensic science in many ways. The reports of cases in which SEM has been used as an auxiliary method in the investigation of exhumed bones are rare. In this article, we report an exhumation that was made to determine if a seized weapon could have been used in a homicide. We used SEM to analyze a fracture in the interior of the skull of the victim. The findings described in this article showed us that it is possible to develop new researches in this field. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coming Into Focus presents a needs assessment related to Iowans with brain injury, and a state action plan to improve Iowa’s ability to meet those needs. Support for this project came from a grant from the Office of Maternal and Child Health to the Iowa Department of Public Health, Iowa’s lead agency for brain injury. The report is a description of the needs of people with brain injuries in Iowa, the status of services to meet those needs and a plan for improving Iowa’s system of supports. Brain injury can result from a skull fracture or penetration of the brain, a disease process such as tumor or infection, or a closed head injury, such as shaken baby syndrome. Traumatic brain injury is a leading cause of death and disability in children and young adults (Fick, 1997). In the United States there are as many as 2 million brain injuries per year, with 300,000 severe enough to require hospitalization. Some 50,000 lives are lost every year to TBI. Eighty to 90 thousand people have moderate to acute brain injuries that result in disabling conditions which can last a lifetime. These conditions can include physical impairments, memory defects, limited concentration, communication deficits, emotional problems and deficits in social abilities. In addition to the personal pain and challenges to survivors and their families, the financial cost of brain injuries is enormous. With traumatic brain injuries, it is estimated that in 1995 Iowa hospitals charged some $38 million for acute care for injured persons. National estimates offer a lifetime cost of $4 million for one person with brain injury (Schootman and Harlan, 1997). With this estimate, new injuries in 1995 could eventually cost over $7 billion dollars. Dramatic improvements in medicine, and the development of emergency response systems, means that more people sustaining brain injuries are being saved. How can we insure that supports are available to this emerging population? We have called the report Coming into Focus, because, despite the prevalence and the personal and financial costs to society, brain injury is poorly understood. The Iowa Department of Public Health, the Iowa Advisory Council on Head Injuries State Plan Task Force, the Brain Injury Association of Iowa and the Iowa University Affiliated Program have worked together to begin answering this question. A great deal of good information already existed. This project brought this information together, gathered new information where it was needed, and carried out a process for identifying what needs to be done in Iowa, and what the priorities will be.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Deir el-Bachit is the largest known Coptic monastery complex in Thebes-West. It dates to the Late Antiquity period between the 6th and the beginning of the 10th century AD. So far, at least 26 individuals from the site were analysed anthropologically. 22 of them were excavated directly at the necropolis, the other 4 are special burials that were found at other locations nearby.Most individuals from the necropolis are male adults. There are two categories of human remains: “mummified” and “skeletonised”. The differences are probably due to social stratification. A substance similar to bitumen was found at the mummies. At that time, resin containing oils and bitumen were normally not used any more. One of the Special burials was an approximately three years old child which was found enclosed within a wall. Another special burial was a juvenile or young adult female who was found in the vault of an abandoned granary. The female was most likely pregnant and fell victim to a violent crime. This is indicated by the bones of a six months old foetus and an intravital skull fracture. She was no contemporary from the time the monastery was cultivated but was later deposited in this area.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: The characteristic findings in accidental head injury consist of linear skull fracture, epidural haematoma, localized subdural haematoma, or cortical contusion because of a linear or translational impact force. Retinal haemorrhages have been found, although uncommon, in accidental head trauma. METHODS: We performed a retrospective study of 24 consecutive cases of children with severe head injuries caused by falls. Inclusion criteria were skull fractures and/or intracranial haemorrhages documented by computerized tomography. All patients underwent a careful ophthalmic examination including dilated indirect fundoscopy within the first 48 h following admission. RESULTS: No retinal haemorrhages could be found in patients whose accidents were plausible and physical and imaging findings were compatible with reported histories. Excessive bilateral retinal haemorrhages were found in only three children with the typical signs of shaken baby syndrome. In eight children, trauma had led to orbital roof fractures. CONCLUSIONS: Retinal haemorrhages were not found in any of the patients with accidental trauma despite the severity of their head injuries. Hence, we add more evidence that there are strong differences between the ocular involvement in accidental translational trauma and those in victims of non-accidental trauma. Fall-related injuries carry a very low risk of retinal haemorrhages.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Beer bottles are often used in physical disputes. If the bottles break, they may give rise to sharp trauma. However, if the bottles remain intact, they may cause blunt injuries. In order to investigate whether full or empty standard half-litre beer bottles are sturdier and if the necessary breaking energy surpasses the minimum fracture-threshold of the human skull, we tested the fracture properties of such beer bottles in a drop-tower. Full bottles broke at 30 J impact energy, empty bottles at 40 J. These breaking energies surpass the minimum fracture-threshold of the human neurocranium. Beer bottles may therefore fracture the human skull and therefore serve as dangerous instruments in a physical dispute.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 14-year-old patient had a low-energy facial blunt trauma that evolved to right facial paralysis caused by parotid hematoma with parotid salivary gland lesion. Computed tomography and angiography demonstrated intraparotid collection without pseudoaneurysm and without radiologic signs of fracture in the face. The patient was treated with serial punctures for hematoma deflation, resolving with regression and complete remission of facial paralysis, with no late sequela. The authors discuss the relationship between facial nerve traumatic injuries associated or not with the presence of facial fractures, emphasizing the importance of early recognition and appropriate treatment of such cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To investigate the facial symmetry of high and low dose methotrexate (MTX) treated rats submitted to experimentally displaced mandibular condyle fracture through the recording of cephalometric measurements. METHODS: One hundred male Wistar rats underwent surgery using an experimental model of right condylar fracture. Animals were divided into four groups: A - saline solution (1mL/week); B - dexamethasone (DEX) (0,15mg/Kg); C - MTX low dose (3 mg/Kg/week); D - MTX high dose (30 mg/Kg). Animals were sacrificed at 1, 7, 15, 30 and 90 days postoperatively (n=5). Body weight was recorded. Specimens were submitted to axial radiographic incidence, and cephalometric mensurations were made using a computer system. Linear measurements of skull and mandible, as well as angular measurements of mandibular deviation were taken. Data were subjected to statistical analyses among the groups, periods of sacrifice and between the sides in each group (alpha=0.05). RESULTS: Animals regained body weight over time, except in group D. There was reduction in the mandibular length and also changes in the maxilla as well as progressive deviation in the mandible in relation to the skull basis in group D. CONCLUSION: Treatment with high dose methotrexate had deleterious effect on facial symmetry of rats submitted to experimentally displaced condylar process fracture.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Open skull fractures have been traditionally managed in 2 stages: urgent craniotomy and elevation of the fracture with removal of contaminated bone, debridement, and delayed cranioplasty. Primary, single-stage repair of these injures has been said to entail risks such as infections. Recent experience, however, disproved these concerns.We used a primary single-stage reconstruction for patients presenting with open depressed skull fractures. All patients received antibiotic prophylaxis. The patients underwent elevation of the compound fracture and craniotomy if necessary. Debridement was performed, followed by skull reconstruction using a 0.6-mm titanium mesh.We present 5 consecutive male patients (age, 32.2 +/- 15.6 years) who underwent primary reconstruction of open depressed skull fractures. Clinical and radiologic follow-up was performed 2 months after surgery. The duration of the surgery was 2 +/- 1.6 hours. The size of the implanted mesh was 13 +/- 13.1 cm. No infection was detected in our series, with a follow-up period of 22 +/- 6.5 months (range, 16-29 months). The cosmetic result was defined in 4 patients as "excellent" and in 1 patient as "good."Primary reconstruction of open skull fractures with titanium mesh is feasible, safe, and cosmetically preferable than the conventional staged approach. The introduction into clinical practice can be warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To determine the mechanisms predisposing penile fracture as well as the rate of long-term penile deformity and erectile and voiding functions. Methods. All fractures were repaired on an emergency basis via subcoronal incision and absorbable suture with simultaneous repair of eventual urethral lesion. Patients' status before fracture and voiding and erectile functions at long term were assessed by periodic follow-up and phone call. Detailed history included cause, symptoms, and single-question self-report of erectile and voiding functions. Results. Among the 44 suspicious cases, 42 (95.4%) were confirmed, mean age was 34.5 years (range: 18-60), mean follow-up 59.3 months (range 9-155). Half presented the classical triad of audible crack, detumescence, and pain. Heterosexual intercourse was the most common cause (28 patients, 66.7%), followed by penile manipulation (6 patients, 14.3%), and homosexual intercourse (4 patients, 9.5%). Woman on top was the most common heterosexual position (n = 14, 50%), followed by doggy style (n = 8, 28.6%). Four patients (9.5%) maintained the cause unclear. Six (14.3%) patients had urethral injury and two (4.8%) had erectile dysfunction, treated by penile prosthesis and PDE-5i. No patient showed urethral fistula, voiding deterioration, penile nodule/curve or pain. Conclusions. Woman on top was the potentially riskiest sexual position (50%). Immediate surgical treatment warrants long-term very low morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As graphene has become one of the most important materials, there is renewed interest in other similar structures. One example is silicene, the silicon analogue of graphene. It shares some of the remarkable graphene properties, such as the Dirac cone, but presents some distinct ones, such as a pronounced structural buckling. We have investigated, through density functional based tight-binding (DFTB), as well as reactive molecular dynamics (using ReaxFF), the mechanical properties of suspended single-layer silicene. We calculated the elastic constants, analyzed the fracture patterns and edge reconstructions. We also addressed the stress distributions, unbuckling mechanisms and the fracture dependence on the temperature. We analysed the differences due to distinct edge morphologies, namely zigzag and armchair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the outcomes in patients treated for humerus distal third fractures with MIPO technique and visualization of the radial nerve by an accessory approach, in those without radial palsy before surgery. The patients were treated with MIPO technique. The visualization and isolation of the radial nerve was done by an approach between the brachialis and the brachiorradialis, with an oblique incision, in the lateral side of the arm. MEPS was used to evaluate the elbow function. Seven patients were evaluated with a mean age of 29.8 years old. The average follow up was 29.85 months. The radial neuropraxis after surgery occurred in three patients. The sensorial recovery occurred after 3.16 months on average and also of the motor function, after 5.33 months on average, in all patients. We achieved fracture consolidation in all patients (M=4.22 months). The averages for flexion-extension and prono-supination were 112.85° and 145°, respectively. The MEPS average score was 86.42. There was no case of infection. This approach allowed excluding a radial nerve interposition on site of the fracture and/or under the plate, showing a high level of consolidation of the fracture and a good evolution of the range of movement of the elbow. Level of Evidence IV, Case Series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to correlate the pre-operative imaging, vascularity of the proximal pole, and histology of the proximal pole bone of established scaphoid fracture non-union. This was a prospective non-controlled experimental study. Patients were evaluated pre-operatively for necrosis of the proximal scaphoid fragment by radiography, computed tomography (CT) and magnetic resonance imaging (MRI). Vascular status of the proximal scaphoid was determined intra-operatively, demonstrating the presence or absence of puncate bone bleeding. Samples were harvested from the proximal scaphoid fragment and sent for pathological examination. We determined the association between the imaging and intra-operative examination and histological findings. We evaluated 19 male patients diagnosed with scaphoid nonunion. CT evaluation showed no correlation to scaphoid proximal fragment necrosis. MRI showed marked low signal intensity on T1-weighted images that confirmed the histological diagnosis of necrosis in the proximal scaphoid fragment in all patients. Intra-operative assessment showed that 90% of bones had absence of intra-operative puncate bone bleeding, which was confirmed necrosis by microscopic examination. In scaphoid nonunion MRI images with marked low signal intensity on T1-weighted images and the absence of intra-operative puncate bone bleeding are strong indicatives of osteonecrosis of the proximal fragment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the fracture strength of endodontically treated teeth restored with different posts and variable ferrule heights. Sixty freshly extracted human canines were treated endodontically and randomly assigned to 6 groups (n=10), being restored with custom-made cast post-and-core (CP0 and CP3 groups), prefabricated post and composite resin core (PF0 and PF3 groups), and composite resin (CR0 and CR3 groups). The CP0, PF0 and CR0 groups presented no ferrule and the CP3, PF3 and CR3 presented 3 mm of coronal structure. All teeth were restored with full metal crowns. The fracture strength was measured in a universal testing machine at 45o to the long axis of the tooth until failure. Data were analyzed statistically by 2-way ANOVA and Tukey's test (?=0.05). When the mean fracture strength values were compared (CP0 group - 820.20 N, CP3 group - 1179.12 N; PF0 group - 561.05 N; PF3 group - 906.79 N; CR0 group - 297.84 N; and CR3 group - 1135.15 N) there was statistically significant among the groups (p<0.05), except for the three groups with 3 mm of coronal remaining, which were similar to each other. The results of this study showed that the ferrule in crowns promoted significantly higher fracture strength in the endodontically treated teeth.