999 resultados para Size Analysis


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent advances in psychosocial treatments for schizophrenia have targeted social cognitive deficits. A critical literature review and effect-size (ES) analysis was conducted to investigate the efficacy of comprehensive programs of social cognitive training in schizophrenia. Results revealed 16 controlled studies consisting of seven models of comprehensive treatment with only three of these treatment models investigated in more than one study. The effects of social cognitive training were reported in 11/15 studies that included facial affect recognition skills (ES=.84) and 10/13 studies that included theory-of-mind (ES=.70) as outcomes. Less than half (4/9) of studies that measured attributional style as an outcome reported effects of treatment, but effect sizes across studies were significant (ESs=.30-.52). The effect sizes for symptoms were modest, but, with the exception of positive symptoms, significant (ESs=.32-.40). The majority of trials were randomized (13/16), selected active control conditions (11/16) and included at least 30 participants (12/16). Concerns for this area of research include the absence of blinded outcome raters in more than 50% of trials and low rates of utilization of procedures for maintaining treatment fidelity. These findings provide preliminary support for the broader use of comprehensive social cognitive training procedures as a psychosocial intervention for schizophrenia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dispersion of the samples in soil particle-size analysis is a fundamental step, which is commonly achieved with a combination of chemical agents and mechanical agitation. The purpose of this study was to evaluate the efficiency of a low-speed reciprocal shaker for the mechanical dispersion of soil samples of different textural classes. The particle size of 61 soil samples was analyzed in four replications, using the pipette method to determine the clay fraction and sieving to determine coarse, fine and total sand fractions. The silt content was obtained by difference. To evaluate the performance, the results of the reciprocal shaker (RSh) were compared with data of the same soil samples available in reports of the Proficiency testing for Soil Analysis Laboratories of the Agronomic Institute of Campinas (Prolab/IAC). The accuracy was analyzed based on the maximum and minimum values defining the confidence intervals for the particle-size fractions of each soil sample. Graphical indicators were also used for data comparison, based on dispersion and linear adjustment. The descriptive statistics indicated predominantly low variability in more than 90 % of the results for sand, medium-textured and clay samples, and for 68 % of the results for heavy clay samples, indicating satisfactory repeatability of measurements with the RSh. Medium variability was frequently associated with silt, followed by the fine sand fraction. The sensitivity analyses indicated an accuracy of 100 % for the three main separates (total sand, silt and clay), in all 52 samples of the textural classes heavy clay, clay and medium. For the nine sand soil samples, the average accuracy was 85.2 %; highest deviations were observed for the silt fraction. In relation to the linear adjustments, the correlation coefficients of 0.93 (silt) or > 0.93 (total sand and clay), as well as the differences between the angular coefficients and the unit < 0.16, indicated a high correlation between the reference data (Prolab/IAC) and results obtained with the RSh. In conclusion, the mechanical dispersion by the reciprocal shaker of soil samples of different textural classes was satisfactory. The results allowed recommending the use of the equipment at low agitation for particle size- analysis. The advantages of this Brazilian apparatus are its low cost, the possibility to simultaneously analyze a great number of samples using ordinary, easily replaceable glass or plastic bottles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Raaka-aineen hiukkaskoko on lääkekehityksessä keskeinen materiaaliparametri. Lääkeaineen partikkelikoko vaikuttaa moneen lääketuotteen tärkeään ominaisuuteen, esimerkiksi lääkkeen biologiseen hyväksikäytettävyyteen. Tässä diplomityössä keskityttiin jauhemaisten lääkeaineiden hiukkaskoon määrittämiseen laserdiffraktiomenetelmällä. Menetelmä perustuu siihen, että partikkeleista sironneen valon intensiteetin sirontakulmajakauma on riippuvainen partikkelien kokojakaumasta. Työn kirjallisuusosassa esiteltiin laserdiffraktiomenetelmän teoriaa. PIDS (Polarization Intensity Differential Scattering) tekniikka, jota voidaan käyttää laserdiffraktion yhteydessä, on myös kuvattu kirjallisuusosassa. Muihin menetelmiin perustuvista analyysimenetelmistä tutustuttiin mikroskopiaan sekä aerodynaamisen lentoajan määrittämiseen perustuvaan menetelmään. Kirjallisuusosassa esiteltiin myös partikkelikoon yleisimpiä esitystapoja. Työn kokeellisen osan tarkoituksena oli kehittää ja validoida laserdiffraktioon perustuva partikkelikoon määritysmenetelmä tietylle lääkeaineelle. Menetelmäkehitys tehtiin käyttäen Beckman Coulter LS 13 320 laserdiffraktoria. Laite mahdollistaa PIDS-tekniikan käytön laserdiffraktiotekniikan ohella. Menetelmäkehitys aloitettiin arvioimalla, että kyseinen lääkeaine soveltuu parhaiten määritettäväksi nesteeseen dispergoituna. Liukoisuuden perusteella väliaineeksi valittiin tällä lääkeaineella kyllästetty vesiliuos. Dispergointiaineen sekä ultraäänihauteen käyttö havaittiin tarpeelliseksi dispergoidessa kyseistä lääkeainetta kylläiseen vesiliuokseen. Lopuksi sekoitusnopeus näytteensyöttöyksikössä säädettiin sopivaksi. Validointivaiheessa kehitetyn menetelmän todettiin soveltuvan hyvin kyseiselle lääkeaineelle ja tulosten todettiin olevan oikeellisia sekä toistettavia. Menetelmä ei myöskään ollut herkkä pienille häiriöille.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dispersão da amostra de solo é uma etapa fundamental da análise granulométrica, sendo realizada mediante o uso de dispersantes químicos e agitação mecânica. O objetivo deste trabalho foi avaliar a eficiência de mesa agitadora reciprocante de baixa rotação na dispersão mecânica de amostras de solos de diferentes classes texturais. Foram realizadas análises granulométricas em 61 amostras com quatro repetições, empregando o método da pipeta para determinação da fração argila e tamisagem para determinação das frações areia grossa, areia fina e areia total, sendo o silte determinado por diferença. Na avaliação de desempenho, os resultados obtidos com uso da mesa agitadora reciprocante (MAR) foram comparados com dados disponíveis para as mesmas amostras oriundos de relatórios do Ensaio de Proficiência IAC para Laboratórios de Análises de Solos - Prolab/IAC. Análises de acurácia foram realizadas com base nos valores dos intervalos de confiança definidos para cada fração granulométrica componente de cada amostra ensaiada. Indicadores gráficos também foram utilizados na comparação de dados, por meio de dispersão e ajuste linear. A estatística descritiva indicou preponderância de baixa variabilidade em mais de 90 % dos resultados obtidos para as amostras de texturas arenosa, média e argilosa e em 68 % dos obtidos para as amostras de textura muito argilosa, indicando boa repetibilidade dos resultados obtidos com a MAR. Média variabilidade foi mais frequentemente associada à fração silte, seguida da fração areia fina. Os resultados das análises de sensibilidade indicam acurácia de 100 % nas três frações granulométricas - areia total, silte e argila - para todas as amostras analisadas pertencentes às classes texturais muito argilosa, argilosa e média. Para as nove amostras de textura arenosa, a acurácia média foi de 85,2 %, e os maiores desvios ocorreram em relação à fração silte. Nas aproximações lineares, coeficientes de correlação igual (silte) ou superiores (areia total e argila) a 0,93, bem como diferenças menores do que 0,16 entre os coeficientes angulares das retas e o valor unitário, indicam alta correlação entre os resultados de referência (Prolab/IAC) e os obtidos nos ensaios com a MAR. Conclui-se pelo desempenho satisfatório da mesa agitadora reciprocante de baixa rotação para dispersão mecânica de amostras de solo de diferentes classes texturais para fins de análise granulométrica, permitindo recomendar o uso alternativo do equipamento quando se emprega agitação lenta. As vantagens do uso do equipamento nacional incluem o baixo custo, a possibilidade de análise simultânea de grande número de amostras e o uso de frascos comuns, de vidro ou de plástico, baratos e de fácil reposição.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. Methods: One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab(US Patent). A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE<0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Results: Bio-Optics: sample size, 97 +/- 22 cells; RE, 6.52 +/- 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 162 +/- 34 cells. CSO: sample size, 110 +/- 20 cells; RE, 5.98 +/- 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 157 +/- 45 cells. Konan: sample size, 80 +/- 27 cells; RE, 10.6 +/- 3.67; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 336 +/- 131 cells. Topcon: sample size, 87 +/- 17 cells; RE, 10.1 +/- 2.52; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 382 +/- 159 cells. Conclusions: A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nanotechnologies are rapidly expanding because of the opportunities that the new materials offer in many areas such as the manufacturing industry, food production, processing and preservation, and in the pharmaceutical and cosmetic industry. Size distribution of the nanoparticles determines their properties and is a fundamental parameter that needs to be monitored from the small-scale synthesis up to the bulk production and quality control of nanotech products on the market. A consequence of the increasing number of applications of nanomaterial is that the EU regulatory authorities are introducing the obligation for companies that make use of nanomaterials to acquire analytical platforms for the assessment of the size parameters of the nanomaterials. In this work, Asymmetrical Flow Field-Flow Fractionation (AF4) and Hollow Fiber F4 (HF5), hyphenated with Multiangle Light Scattering (MALS) are presented as tools for a deep functional characterization of nanoparticles. In particular, it is demonstrated the applicability of AF4-MALS for the characterization of liposomes in a wide series of mediums. Afterwards the technique is used to explore the functional features of a liposomal drug vector in terms of its biological and physical interaction with blood serum components: a comprehensive approach to understand the behavior of lipid vesicles in terms of drug release and fusion/interaction with other biological species is described, together with weaknesses and strength of the method. Afterwards the size characterization, size stability, and conjugation of azidothymidine drug molecules with a new generation of metastable drug vectors, the Metal Organic Frameworks, is discussed. Lastly, it is shown the applicability of HF5-ICP-MS for the rapid screening of samples of relevant nanorisk: rather than a deep and comprehensive characterization it this time shown a quick and smart methodology that within few steps provides qualitative information on the content of metallic nanoparticles in tattoo ink samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The upper 1200 m of pre-Pliocene sediment recovered by Cape Roberts Project (CRP) drilling off the Victoria Land coast of Antarctica between 1997-1999 has been subdivided into 54 unconformity-bound stratigraphic sequences, spanning the period c. 32 to 17 Ma. The sequences are recognised on the basis of the cyclical vertical stacking of their constituent lithofacies, which are enclosed by erosion surfaces produced during the grounding of the advancing ice margin onto the sea floor. Each sequence represents deposition in a range of offshore shelf to coastal glacimarine sedimentary environments during oscillations in the ice margin across the Western Ross Sea shelf, and coeval fluctuations in water depth. This paper applies spectral analysis techniques to depth- and time-series of sediment grain size (500 samples) for intervals of the core with adequate chronological data. Time series analysis of 0.5-l.0m-spaced grainsize data spanning sequences 9-11 (CRP-2/2A) and sequences 1-7 (CRP-3) suggests that the length of individual sequences correspond to Milankovitch frequencies, probably 41 k.y., but possibly as low as 100 k.y. Higher frequency periodic components at 23 k.y. (orbital precession) and 15-10 k.y. (sub-orbital) are recognised at the intrasequence-scale, and may represent climatic cycles akin to the ice rafting episodes described in the North Atlantic Ocean during the Quaternary. The cyclicity recorded by glacimarine sequences in CRP core provides direct evidence from the periphery of Antarctica for orbital oscillations in the size of the Oligocene-Early Miocene East Antarctic Ice Sheet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Grain-size analyses by sieve and Sedigraph are presented for 115 samples of core from CRP-3, 12 km off the coast of south Victoria Land. The data provide a useful check on visual core descriptions. The geographic setting for the strata sampled, some 790 m of early Oligocene nearshore marine sediments with a persistent glacial influence, is reviewed, and sediment textures interpreted in that context. Sand textures from the CRP-3 samples in the lower part of the core suggest that deposition was initially primarily wave-dominated, but that at times the influence of the waves was over-ridden by episodes of rapid sedimentation. Sedimentary cycles, recognised in the visual description of the core above 485 mbsf, show an increasing proportion of mudstone in the middle of each cycle above 330 mbsf that is interpreted to record periodic sedimentation in deeper water. Sandstone textures in the lower and upper parts of each cycle are interpreted to record departure from and return to shoreface deposition with changes in sea level. Mudstone textures above 176 mbsf indicate sedimentation below wave base. Many of the textures in both sand and mud samples show the coarse 'tail' characteristic of ice-rafted debris, but others do not, indicating ice-free periods. Many sandstones below c. 200 mbsf have virtually no silt, but significant amounts of clay (6 to 17%) that is thought to be of post-depositional origin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this note is to present results of grain size analyses from 118 samples of the CRP-2/2A core using sieve and Sedigraph techniques. The samples were selected to represent the range of facies encountered, and tend to become more widely spaced with depth. Fifteen came from the upper 27 m of Quaternary and Pliocene sediments, 62 from the early Miocene-late Oligocene strata (27 to 307 mbsf), and 41 from the early Oligocene strata beneath (307 to 624 mbsf). The results are intended to provide reference data for lithological descriptions in the core logs (Cape Roberts Science Team, 1999), and to help with facies interpretation. The analytical technique used for determining size frequency of the sand fraction in our samples (sieving) is simple, physical and widely practised for over a century. Thus it provides a useful reference point for analyses produced by other faster and more sophisticated techniques, such as the Malvern laser particle size analysis system (Woolfe et al., 2000), and estimates derived from measurements taken with down-hole logging tools (Bücker, pers. com., 1999).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contourites in the Gulf of Cádiz preserve a unique archive of Mediterranean Outflow Water (MOW) variability over the past 5.3 Ma. In our study we investigate the potential of geochemical data obtained by XRF scanning to decipher bottom current processes and paleoclimatic evolution at two different sites drilled through contourite deposits in the northern Gulf of Cadiz: Site U1387, which is bathed by the upper MOW core, and Site U1389, located more proximal to the Straits of Gibraltar. The lack of major downslope transport at both locations during the Pleistocene makes them ideal locations for the purpose of our study. The results indicate that the Zr/Al ratio, representing the relative enrichment of heavy minerals (zircon) over less dense alumosilicates under strong bottom current flow, is the most useful indicator for a semi-quantitative assessment of current strength. While most elements are biased by current-related processes, the bromine record, representing organic content, preserves the most pristine climate signal rather independent of grain size changes. Hence, Br can be used for chronostratigraphy and site-to-site correlation in addition to stable isotope stratigraphy. Based on these findings we reconstructed MOW variability for Marine Isotope Stages 1-5 using the Zr/Al ratio from Site U1387. The results reveal abrupt, millennial-scale variations of MOW strength during Greenland Stadials (GS) and Interstadials (GI) with strong MOW during GS and glacial Terminations and a complex behavior during Heinrich Stadials. Millennial-scale variability persisting during periods of poorly expressed GS/GI cyclicities implies a strong internal oscillation of the Mediterranean/North Atlantic climate system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Grain-size, terrigenous element and rock magnetic remanence data of Quaternary marine sediments retrieved at the NW African continental margin off Gambia (gravity core GeoB 13602-1, 13°32.71' N, 17°50.96'W) were jointly analyzed by end-member (EM) unmixing methods to distinguish and budget past terrigenous fluxes. We compare and cross-validate the identified single-parameter EM systems and develop a numerical strategy to calculate associated multi-parameter EM properties. One aeolian and two fluvial EMs were found. The aeolian EM is much coarser than the fluvial EMs and is associated with a lower goethite/hematite ratio, a higher relative concentration of magnetite and lower Al/Si and Fe/K ratios. Accumulation rates and grain sizes of the fluvial sediment appear to be primarily constrained by shore distance (i.e., sea-level fluctuations) and to a lesser extent by changes in hinterland precipitation. High dust fluxes occurred during the Last Glacial Maximum (LGM) and during Heinrich Stadials (HS) while the fluvial input remained unchanged. Our approach reveals that the LGM dust fluxes were ~7 times higher than today's. However, by far the highest dust accumulation occurred during HS 1 (~300 g m**-2 yr** -1), when dust fluxes were ~80 fold higher than today. Such numbers have not yet been reported for NW Africa, and emphasize strikingly different environmental conditions during HSs. They suggest that deflation rate and areal extent of HSs dust sources were much larger due to retreating vegetation covers. Beyond its regional and temporal scope, this study develops new, in principle, generally applicable strategies for multi-method end-member interpretation, validation and flux budgeting calibration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The upper Miocene to Pleistocene sediments recovered at ODP Sites 745 and 746 in the Australian-Antarctic Basin are characterized by cyclic facies changes. Sedimentological investigations of a detailed Quaternary section reveal that facies A is dominated by a high content of siliceous microfossils, a relatively low terrigenous sediment content, an ice-rafted component, low concentrations of fine sediment particles, and a relatively high smectite content. This facies corresponds to interglacial sedimentary conditions. Facies B, in contrast, is characteristic of glacial conditions and is dominated by a large amount of terrigenous material and a smaller opaline component. There is also a prominent ice-rafted component. The microfossils commonly are reworked and broken. The clay mineral assemblages show higher proportions of glacially derived illite and chlorite. A combination of four different processes, attributed to glacial-interglacial cycles, was responsible for the cyclic facies changes during Quaternary time: transport by gravity, ice, and current and changes in primary productivity. Of great importance was the movement of the grounding line of the ice shelves, which directly influenced the intensity of ice rafting and of gravitational sediment transport to the deep sea. The extension of the ice shelves was also responsible for the generation of cold and erosive Antarctic Bottom Water, which controlled the grain-size distribution, particularly of the fine fraction, in the investigated area.