995 resultados para Side pump


Relevância:

70.00% 70.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

实验研究了激光二极管阵列(LDA)侧向抽运国产Nd∶YAG陶瓷棒的准连续及被动调Q激光输出特性。该陶瓷激光器采用LDA侧面紧密环绕均匀排布的抽运结构,陶瓷棒抽运区域长度为20 mm,其总尺寸为3 mm×35 mm,掺杂原子数分数为~1%。在千赫兹准连续运转条件下,当平-平谐振腔的输出耦合镜透过率为47.3%时,获得最大平均功率23 W的1064 nm激光输出,光束发散角为4.5 mrad,斜率效率达12%。在谐振腔内插入Cr4+∶YAG晶体作为被动调Q开关,成功地实现了陶瓷激光器千赫兹重复频率调Q激光脉冲输出,当Cr4+∶YAG晶体初始透过率为60%时,输出激光脉冲宽度(半峰全宽)可窄至14.5 ns,调Q动静比约为40%。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

激光二极管抽运的全固态激光器中,除了激光介质的温度分布和热透镜效应以外,抽运、冷却结构对获得高光束质量、高功率激光输出至关重要。基于热传导方程,在相同的抽运功率和传导冷却边界条件下,对单侧面抽运锯齿形(zigzag)板条、单侧面键合锯齿形板条、部分抽运板条三种不同抽运结构的温度分布、热致应力、温度导致的折射率变化进行了详细的分析,并通过光线追迹方法,比较了光束在锯齿形面内和垂直于锯齿形面内的光程差,由光程差曲线分析了激光束的热透镜效应。对三种抽运结构的端面温度、端面变形和端面变形导致的光程差也进行了对比分

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study presents the findings of applying a Discrete Demand Side Control (DDSC) approach to the space heating of two case study buildings. High and low tolerance scenarios are implemented on the space heating controller to assess the impact of DDSC upon buildings with different thermal capacitances, light-weight and heavy-weight construction. Space heating is provided by an electric heat pump powered from a wind turbine, with a back-up electrical network connection in the event of insufficient wind being available when a demand occurs. Findings highlight that thermal comfort is maintained within an acceptable range while the DDSC controller maintains the demand/supply balance. Whilst it is noted that energy demand increases slightly, as this is mostly supplied from the wind turbine, this is of little significance and hence a reduction in operating costs and carbon emissions is still attained.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The current work compares some slurry pump lab wear results with the wear found across different field applications with d85 particle size ranging from 100 to 4000mm. Side-liner wear life data has been collected for two different impeller geometries and two different material classes (cast iron and natural rubber). Different field wear patterns have been photographed and categorised on the basis of particle size. The field wear patterns showed close similarity to the lab wear patterns particularly in the areas of localised gouging. Wear rates are also compared for the different geometries. Overall trend of wear with particle size for the white iron parts was similar to the grey iron lab tests albeit at significantly lower wear rates. In general, the wear with the rubber side-liner was less at smaller particle sizes but greater for particles larger than d8The current work compares some slurry pump lab wear results with the wear found across different field applications with d85 particle 10 size ranging from 100 to 4000mm. Side-liner wear life data has been collected for two different impeller geometries and two different 11 material classes (cast iron and natural rubber). Different field wear patterns have been photographed and categorised on the basis of particle 12 size. The field wear patterns showed close similarity to the lab wear patterns particularly in the areas of localised gouging. Wear rates are 13 also compared for the different geometries. Overall trend of wear with particle size for the white iron parts was similar to the grey iron lab 14 tests albeit at significantly lower wear rates. In general, the wear with the rubber side-liner was less at smaller particle sizes but greater for 15 particles larger than d85 of about 700mm. © 2001 Elsevier Science B.Y. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The low temperature operation of a heat pump makes it an excellent match for the use of solar energy. At the National University of Singapore, a solar assisted heat pump system has been designed, fabricated and installed to provide water heating and drying. The system also utilizes the air con waste heat, which would normally be released to atmosphere adding to global warming. Experimental results show that the twophase unglazed solar evaporator-collector, instead of losing energy to the ambient, gained a significant amount due to low operating temperature of the collector. As a result, the collector efficiency attains a value greater than 1, when conventional collector equations are used. With this evaporator-collector, the system can be operated even in the absence of solar irradiation. The waste heat was collected from an air-con system, which maintained a room at 20-22 oC. In the condenser side, water at 60 oC was produced at a rate of 3 liter/minute and the drying capacity was 2.2kg/hour. Maximum COP of the system was found to be about 5.5.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We developed a highly efficient diode side-pumped Nd:YAG ceramic laser with a diffusive reflector as an optical pump cavity. A maximum output power of 211.6W was obtained with an optical -to- optical conversion efficiency of 48.7%. This corresponds to the highest conversion efficiency in the side-pumped ceramic rod. Thermal effects of the Nd:YAG ceramic rod were analyzed in detail through the measurements of laser output powers and beam profiles near the critically unstable region. A M-2 beam quality factor of 18.7 was obtained at the maximum laser output power. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A fundamental mode Nd YAG laser is experimentally demonstrated with a stagger pumped laser module and a special resonator. The rod is pumped symmetrically by staggered bar modules. A dynamic fundamental mode is achieved with the special resonator under different pump levels. A maximal continuous wave output of 61 W (M-2 = 1.4) is achieved with a single rod. An average output of 47 W, pulse width of 54 ns, pulse energy of 4.7 mJ and peak power of 87 kW are obtained under the Q-switched operation of 10 kHz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a new technique, called SAP, for side pumping of double-clad, rare-earth-doped fiber lasers using fiber-coupled pump sources. The highest coupling efficiency can even exceed 92% in theory with this structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a LD side-pumped fundamental-mode (Mx(2) = 1.35 and My(2) = 1.27) passive Q-switched and mode-locked Nd:YAG laser based on a semiconductor saturable absorber mirror (SESAM). At a pump current of 12.5 A, the average output power of 5.68 W with 80 kHz repetition rate and 2 mu s pulse width of the Q-switched envelope was generated. The repetition rate of the mode-locked pulse within the Q-switched envelope of 88 MHz was achieved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Design of the typical laser diode side-pumped Nd:YAG rod system has been discussed using the conventional ray tracing method in this paper. Firstly introduce two basic matrices, refractional and translational matrix, described the transmission of nonparaxial light ray in the medium without concerning the absorption of light. And then, using those matrices, analyze the distribution of pump light in the crystal respectively under the condition of directly pumped system and indirectly pumped system with a cylindrical quartz rod as focusing lens. From the result of simulation, we compare the advantage and disadvantage of the two pumped method, and mainly consider how to select the diameter of the focus lens and cooling tube, indicate the effect of deionized water and cooling tube have on the pump light distribution in the active material. At last, make some conclusions about the side-pumped Nd:YAG laser system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A number of tight urinary epithelia, as exemplified by the turtle bladder, acidify the luminal solution by active transport of H+ across the luminal cell membrane. The rate of active H+ transport (JH) decreases as the electrochemical potential difference for H+ [delta mu H = mu H(lumen) - mu H(serosa)] across the epithelium is increased. The luminal cell membrane has a low permeability for H+ equivalents and a high electrical resistance compared with the basolateral cell membrane. Changes in JH thus reflect changes in active H+ transport across the luminal membrane. To examine the control of JH by delta mu H in the turtle bladder, transepithelial electrical potential differences (delta psi) were imposed at constant acid-base conditions or the luminal pH was varied at delta psi = 0 and constant serosal PCO2 and pH. When the luminal compartment was acidified from pH 7 to 4 or was made electrically positive, JH decreased as a linear function of delta mu H as previously described. When the luminal compartment was made alkaline from pH 7 to 9 or was made electrically negative, JH reached a maximal value, which was the same whether the delta mu H was imposed as a delta pH or a delta psi. The nonlinear JH vs. delta mu H relation does not result from changes in the number of pumps in the luminal membrane or from changes in the intracellular pH, but is a characteristic of the H+ pumps themselves. We propose a general scheme, which, because of its structural features, can account for the nonlinearity of the JH vs. delta mu H relations and, more specifically, for the kinetic equivalence of the effects of the chemical and electrical components of delta mu H. According to this model, the pump complex consists of two components: a catalytic unit at the cytoplasmic side of the luminal membrane, which mediates the ATP-driven H+ translocation, and a transmembrane channel, which mediates the transfer of H+ from the catalytic unit to the luminal solution. These two components may be linked through a buffer compartment for H+ (an antechamber).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Unidirectional proton transport in bacteriorhodopsin is enforced by the switching machinery of the active site. Threonine 89 is located in this region, with its O—H group forming a hydrogen bond with Asp-85, the acceptor for proton transfer from the Schiff base of the retinal chromophore. Previous IR spectroscopy of [3-18O]threonine-labeled bacteriorhodopsin showed that the hydrogen bond of the O—D group of Thr-89 in D2O is strengthened in the K photocycle intermediate. Here, we show that the strength and orientation of this hydrogen bond remains unchanged in the L intermediate and through the M intermediate. Furthermore, a strong interaction between Asp-85 and the O—H (O—D) group of Thr-89 in M is indicated by a shift in the C⩵O stretching vibration of the former because of 18O substitution in the latter. Thus, the strong hydrogen bond between Asp-85 and Thr-89 in K persists through M, contrary to structural models based on x-ray crystallography of the photocycle intermediates. We propose that, upon photoisomerization of the chromophore, Thr-89 forms a tight, persistent complex with one of the side-chain oxygens of Asp-85 and is thereby precluded from participating in the switching process. On the other hand, the loss of hydrogen bonding at the other oxygen of Asp-85 in M may be related to the switching event.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis records the design and development of an electrically driven, air to water, vapour compression heat pump of nominally 6kW heat output, for residential space heating. The study was carried out on behalf of GEC Research Ltd through the Interdisciplinary Higher Degrees Scheme at Aston University. A computer based mathematical model of the vapour compression cycle was produced as a design aid, to enable the effects of component design changes or variations in operating conditions to be predicted. This model is supported by performance testing of the major components, which revealed that improvements in the compressor isentropic efficiency offer the greatest potential for further increases in cycle COPh. The evaporator was designed from first principles, and is based on wire-wound heat transfer tubing. Two evaporators, of air side area 10.27 and 16.24m2, were tested in a temperature and humidity controlled environment, demonstrating that the benefits of the large coil are greater heat pump heat output and lower noise levels. A systematic study of frost growth rates suggested that this problem is most severe at the conditions of saturated air at 0oC combined with low condenser water temperature. A dynamic simulation model was developed to predict the in-service performance of the heat pump. This study confirmed the importance of an adequate radiator area for heat pump installations. A prototype heat pump was designed and manufactured, consisting of a hermetic reciprocating compressor, a coaxial tube condenser and a helically coiled evaporator, using Refrigerant 22. The prototype was field tested in a domestic environment for one and a half years. The installation included a comprehensive monitoring system. Initial problems were encountered with defrosting and compressor noise, both of which were solved. The unit then operated throughout the 1985/86 heating season without further attention, producing a COPh of 2.34.