945 resultados para Scanning electronic microscope (SEM)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate, through scanning electronic microscopy, the effect of sharpening with different sharpening stones on the cutting angle of periodontal curettes (Gracey 5-6), and the influence on root surfaces after debridement and planing. The experimental model consisted of two different phases. In the first, the cutting angles of fifteen stainless steel Gracey 5-6 curettes were analyzed under a scanning electronic microscope after being sharpened with different types of stones. In the second phase, the root surfaces of 25 newly extracted teeth were evaluated with a scanning electronic microscope after being debrided with curettes sharpened with different stones. Analysis of the results showed that the synthetic stones (aluminum oxide and carborundum) are more abrasive and produce more irregular cutting angles, whereas Arkansas stones are less abrasive and produce smoother and more defined cutting angles. There was no significant statistical differences among the five groups tested with regard to the degree of irregularity of the root surfaces after instrumentation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Ultrasonic excitation (US) was applied to glass ionomer cement (GIC) during early set time to increase the advantageous properties of this material. Purpose: The aim of this in vitro study was to assess the inner porosity of GIC after US. Study design: A total of 16 specimens, for each material, were prepared from high-viscosity GIC Fuji IX GP, Ketac Molar, and Ketac Molar Easymix. Half of these specimens (n = 8) received 30 s of US during the initial cement setting. After completion of the material setting, specimens were fractured and observed by scanning electronic microscopy to quantitatively assay porosity inside the material using Image J software. Results: Statistical data analysis revealed that US reduced the porosity for all tested materials (P <= 0.05). The following reductions (expressed in percentages) were achieved: Fuji IX-from 3.9% to 2.8%; Ketac Molar Easy Mix-from 4.4% to 2.6%, and Ketac Molar-from 2.4% to 1.6%. Conclusion: Under the tested conditions, US was an effective method for porosity reduction inside the material. Microsc. Res. Tech. 74:54-57, 2011. (C) 2010 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate, by scanning electronic microscopy (SEM), the cleaning of the root canal walls after instrumentation and irrigation with 2.5% sodium hypochlorite (NaOCl) associated with 2% chlorhexidine (CHX) gel or liquid, combined or not with 17% ethylenediamine tetra-acetic acid (EDTA).Study design. Sixty single-root human teeth were subjected to standardized root canal instrumentation with different irrigants (n = 10): G1) NaOCl + CHX liquid; G2) NaOCl + CHX liquid + EDTA + saline solution; G3) NaOCl + CHX gel; G4) NaOCl + CHX gel + EDTA + saline solution; G5) saline solution; G6) saline solution + EDTA. After instrumentation, the teeth were prepared for SEM analysis (x500 and x2,000) to evaluate the cleaning of the cervical, middle, and apical thirds. The area analyzed was quantified according to the percentage of open and closed tubules, and data were statistically analyzed by analysis of variance and Tukey tests (P = .05).Results. The number of open tubules was highest in G4 in all root thirds, showing statistically significant difference from G1, G2, and G5 (P < .05). G1 presented higher quantity of closed tubules significant than G2.Conclusion. Irrigation with NaOCl and CHX gel followed by EDTA and saline solution produced greater cleaning of the root canal walls. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e82-e87)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We theoretically investigate spin-polarized transport in a system composed of a ferromagnetic scanning-tunneling-microscope (STM) tip coupled to an adsorbed atom (adatom) on a host surface. Electrons can tunnel directly from the tip to the surface or via the adatom. Since the tip is ferromagnetic and the host surface (metal or semiconductor) is nonmagnetic we obtain a spin-diode effect when the adatom is in the regime of single occupancy. This effect leads to an unpolarized current for direct bias (V > 0) and polarized current for reverse (V < 0) bias voltages, if the tip is nearby the adatom. Within the nonequilibrium Keldysh technique we analyze the interplay between the lateral displacement of the tip and the intra adatom Coulomb interaction on the spin-diode effect. As the tip moves away from the adatom the spin-diode effect vanishes and the currents become polarized for both V > 0 and V < 0. We also find an imbalance between the up and down spin populations in the adatom, which can be tuned by the tip position and the bias. Finally, due to the presence of the adsorbate on the surface, we observe spin-resolved Friedel oscillations in the current, which reflects the oscillations in the calculated local density of states (LDOS) of the subsystem surface + adatom.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The objective of this study was to compare the superficial morphology of bovine and human sclerotic dentine. Design: For the morphological analysis, bovine (n = 3) and human (n = 3) incisors exhibiting exposed dentine were used. Dentine presented characteristics of sclerosis: brownish, smooth and shiny-the vitreous appearance. The teeth were prepared for assessment on a scanning electron microscope (SEM). Three pre-determined areas of each sample were submitted to SEM. The number of open tubules per area was obtained from the electron micrographs (n = 9 per group) for comparison purposes. Results: The number of open tubules in both species compared were similar (p > 0.05). Human dentine presented 31.89 +/- 23.94 open tubules per area, whereas bovine dentine showed 30.33 +/- 18.14 open tubules per area. Conclusion: Based on the results, we concluded that dentine exposed at the incisal surface of human and bovine teeth presented similar clinical and micro-morphological aspects, represented by surfaces with equivalent numbers of open dentinal tubules. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A significant loss in electron probe current can occur before the electron beam enters the specimen chamber of an environmental scanning electron microscope (ESEM). This loss results from electron scattering in a gaseous jet formed inside and downstream (above) the pressure-limiting aperture (PLA), which separates the high-pressure and high-vacuum regions of the microscope. The electron beam loss above the PLA has been calculated for three different ESEMs, each with a different PLA geometry: an ElectroScan E3, a Philips XL30 ESEM, and a prototype instrument. The mass thickness of gas above the PLA in each case has been determined by Monte Carlo simulation of the gas density variation in the gas jet. It has been found that the PLA configurations used in the commercial instruments produce considerable loss in the electron probe current that dramatically degrades their performance at high chamber pressure and low accelerating voltage. These detrimental effects are minimized in the prototype instrument, which has an optimized thin-foil PLA design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Comparative morphometric and morphological studies of eggs under scanning electron microscope (SEM) were undertaken in the three strains of two karyotypic forms of Anopheles aconitus, i.e., Form B (Chiang Mai and Phet Buri strains) and Form C (Chiang Mai and Mae Hong Son strains). Morphometric examination revealed the intraspecific variation with respect to the float width [36.77 ± 2.30 µm (Form C: Chiang Mai strain) = 38.49 ± 2.78 µm (Form B: Chiang Mai strain) = 39.06 ± 2.37 µm (Form B: Phet Buri strain) > 32.40 ± 3.52 µm (Form C: Mae Hong Son strain)] and number of posterior tubercles on deck [2.40 ± 0.52 (Form B: Phet Buri strain) = 2.70 ± 0.82 (Form B: Chiang Mai strain) < 3.10 ± 0.32 (Form C: Chiang Mai strain) = 3.20 ± 0.42 (Form C: Mae Hong Son strain)], whereas the surface topography of eggs among the three strains of two karyotypic forms were morphologically similar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three species of Siphomycetes: Rhizopus arhizus, Rhizopus equinus and Rhizopus nigricans, as well as a Septomycete: Emericella nidulans, have been examined by means of a scanning electron microscope. Among the difjerent Rhizopus, this technique showed differences in the appearance of the sporangia. In Emericella nidulans, scanning microscopy enábled one to ascertain that the "Hull cells" were completely hollow and also demonstrated the ornemented aspect of the ascospores.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

First and second instar larvae of some Sarcophagidae (Diptera) of the tribe Raviniini are described on observations with a scanning electron microscope.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L1, L2 and L3 of Oxysarcodexia paulistanensis (Mattos), L3 of O. confusa Lopes, L2 of Ravinia belforti (Prado & Fonseca) and L2 of Oxyvinia excisa (Lopes) were described and figured using scanning electron microscope.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Male genitalia of Oxyvinia exicisa (Lopes), Oxysarcodexia thomax (Walker), O. fluminensis Lopes, Sarcodexia lambens (Wiedemann), Peckia chrysostoma (Wiedemann) and Liopygia ruficornis (Fabricius) were studied based on scanning electron microscope photography. Some important details were evidentiated with this method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coating and filler pigments have strong influence to the properties of the paper. Filler content can be even over 30 % and pigment content in coating is about 85-95 weight percent. The physical and chemical properties of the pigments are different and the knowledge of these properties is important for optimising of optical and printing properties of the paper. The size and shape of pigment particles can be measured by different analysers which can be based on sedimentation, laser diffraction, changes in electric field etc. In this master's thesis was researched particle properties especially by scanning electron microscope (SEM) and image analysis programs. Research included nine pigments with different particle size and shape. Pigments were analysed by two image analysis programs (INCA Feature and Poikki), Coulter LS230 (laser diffraction) and SediGraph 5100 (sedimentation). The results were compared to perceive the effect of particle shape to the performance of the analysers. Only image analysis programs gave parameters of the particle shape. One part of research was also the sample preparation for SEM. Individual particles should be separated and distinct in ideal sample. Analysing methods gave different results but results from image analysis programs corresponded even to sedimentation or to laser diffraction depending on the particle shape. Detailed analysis of the particle shape required high magnification in SEM, but measured parameters described very well the shape of the particles. Large particles (ecd~1 µm) could be used also in 3D-modelling which enabled the measurement of the thickness of the particles. Scanning electron microscope and image analysis programs were effective and multifunctional tools for particle analyses. Development and experience will devise the usability of analysing method in routine use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a calibration method which can be utilized for the analysis of SEM images. The field of application of the developed method is a calculation of surface potential distribution of biased silicon edgeless detector. The suggested processing of the data collected by SEM consists of several stages and takes into account different aspects affecting the SEM image. The calibration method doesn’t pretend to be precise but at the same time it gives the basics of potential distribution when the different biasing voltages applied to the detector.