997 resultados para Scanner intraoral


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre no Instituto Superior de Ciências da Saúde Egas Moniz

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tradicionalmente, los ortodoncistas han realizado las mediciones dentales en los modelos de yeso, pero los avances tecnológicos permiten ahora a los ortodoncistas realizar esas mediciones en los modelos digitales. El propósito de este estudio fue comparar la fiabilidad y reproducibilidad de las medidas de los tamaños dentarios y las arcadas dentarias entre el método manual y los métodos digitales 3D obtenidos por un escáner intraoral CEREC Omnicam (Sirona Dental Systems) y dos escáneres extraorales: inEos X5 (Sirona Dental Systems) y Dental Scanner SMART (Open Technologies). Un modelo de yeso, un escaneado intraoral y dos modelos digitales con un escáner extraoral fueron realizadas para cada uno de los 20 sujetos. Las medidas de los tamaños dentarios, la distancia intercanina y la distancia intermolar de los modelos digitales se compararon con los correspondientes modelos de yeso (estándar de oro) Se utilizó el test de ANOVA para establecer la fiabilidad entre los cuatro métodos y el coeficiente de correlación intraclase fue calculado para determinar la reproducibilidad intra- e inter-examinador. Los resultados encontrados fueron que no existieron diferencias estadísticamente significativas entre las medidas hechas directamente en los modelos de yeso y los modelos digitales. Los coeficientes de correlación intraclase tanto intra- e inter-examinador fue alto y considerado bueno para los cuatro métodos de medición. CCI> 0.90. Se concluyó que las mediciones en los modelos digitales obtenidos con un escáner extraoral e intraoral son fiables y reproducibles

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study ascertained whether under dental erosion models that closely mimics the real-life situation enamel and root dentin from bovine origin would be reliable substitutes for human counterparts. Through a 2x2 crossover design, in a first trial, 14 volunteers wore a palatal device containing slabs of bovine and human enamel. Half of the participants ingested (4x daily, for 10 days) orange juice first, crossing over to mineral water, while the remainder received the reverse sequence. In a second trial, volunteers wore devices with slabs of bovine and human root dentin. Except for the duration of each intraoral phase, which lasted 2 rather 10 days, the experiment with root dentin run exactly as for enamel. Dental substrates were analyzed for surface microhardness. Two-way ANOVAs (α=0.05) indicated no difference between the microhardness values recorded for human and bovine enamel (p=0.1350), but bovine root dentin had lower microhardness compared to its human counterpart (p=0.0432). While bovine enamel can reliably substitute its human counterpart in in situ dental erosion models, bovine root dentin does not seem to be a viable alternative to the corresponding human tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SKAN: Skin Scanner - System for Skin Cancer Detection Using Adaptive Techniques - combines computer engineering concepts with areas like dermatology and oncology. Its objective is to discern images of skin cancer, specifically melanoma, from others that show only common spots or other types of skin diseases, using image recognition. This work makes use of the ABCDE visual rule, which is often used by dermatologists for melanoma identification, to define which characteristics are analyzed by the software. It then applies various algorithms and techniques, including an ellipse-fitting algorithm, to extract and measure these characteristics and decide whether the spot is a melanoma or not. The achieved results are presented with special focus on the adaptive decision-making and its effect on the diagnosis. Finally, other applications of the software and its algorithms are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lead (Pb) contamination in the black paper that recovers intraoral films (BKP) has been investigated. BKP samples were collected from the Radiology Clinics of the Dental School of Ribeirao Preto, University of Sao Paulo, Brazil. For sake of comparison, four different methods were used. The results revealed the presence of high lead levels, well above the maximum limit allowed by the legislation. Pb contamination levels achieved after the following treatments: paper digestion in nitric acid, microwave treatment, DIN38414-54 method and TCLP method were 997 mu g g(-1), 189 mu g g(-1), 20.8 mu g g(-1), and 54.0 mu g g(-1), respectively. Flame atomic absorption spectrometry (FAAS) and inductively coupled plasma mass spectrometry (ICP-MS) were employed for lead determination according to the protocols of the applied methods. Lead contamination in used BKP was confirmed by scanning electron microscopy coupled with energy dispersive X-ray microanalysis (SEM-EDS). All the SEM imaging was carried out in the secondary electron mode (SE) and backscattered-electron mode (QBSD) following punctual X-ray fluorescence spectra. Soil contamination derived from this product revealed the urgent need of addressing this problem. These elevated Pb levels, show that a preliminary treatment of BKP is mandatory before it is disposed into the common trash. The high lead content of this material makes its direct dumping into the environment unwise. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the usefulness of intraoral ultrasonography (IOUS) as a tool for predicting neck metastasis. Squamous cell carcinoma (SCC) of the tongue is aggressive and has a great propensity to metastasize to cervical lymph nodes. SCC of the oral cavity has a worse prognosis when associated with metastatic cervical nodes. Therefore, the metastatic potential of tongue carcinoma should be graded preoperatively to help determine the requirement for neck dissection. Nineteen patients (11 men, 8 women) between 36 and 79 years of age (mean age 60) with T1 to T4a TNM-stage tongue carcinomas were evaluated preoperatively with IOUS. Clinical and pathological TNM classifications were performed. The average tumor thicknesses measured using histological sections were significantly (p < 0.01) lower than those with IOUS (1.3 vs. 1.6 cm, respectively). A significant correlation was observed between the tumor thickness measured using ultrasonography and that measured using histological sections (pathology). Based on this greater accuracy, the cutoff point of tumor thickness based on IOUS evaluation for predicting neck metastasis was determined to be 1.8 cm. Some factors may influence neck metastasis. A knowledge of these would help to avoid unnecessary surgical intervention for N0 patients. The results of this study indicates that there is a significant correlation between neck metastasis and tumor thickness. Intraoral ultrasonography is useful tool for identifying tongue tumors and measuring their thickness, with the thickness measured by IOUS showing a very good correlation with histological measurements. Moreover, IOUS provides prognostic information prior to surgical treatment since tumor thickness can predict the chance of recognizing metastatic cervical nodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The Gow-Gates technique is said to have several advantages over traditional techniques to achieve mandibular nerve anesthesia; however, its routine use is quite limited, mainly due to complications during visual alignment of reference landmarks. The purpose of this study was to verify the validity and accuracy of a new method to reach the injection site. Material and Methods: Fifteen magnetic resonance images were captured. Distances from the ideal injection point in the condylar neck (puncture ideal) to the injection points located in the a and 0 plane intersection (Puncture Gow-Gates and puncture modified) were measured and compared. Results: Positive and significant (P <= .003) Pearson correlations between landmarks and injection points confirmed the validity of the modified technique. Paired t test showed that the segment line puncture ideal-puncture modified, 5.17 mm, was 3 times shorter (P < .001) than the segment line puncture ideal-puncture Gow-Gates, 17.91 mm. As calculated by linear regression, establishing the injection point of the modified technique depended only on the anteroposterior and lateromedial condyle positions. Conclusions: The modified technique proved to be valid and precise and has a determined and an effective injection site. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:2609-2616, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate pulp oxygenation levels (%SpO(2)) in patients with malignant intraoral and oropharyngeal tumors treated by radiotherapy (RT). Methods: Pulp oxygenation levels were measured by pulse oximetry. Twenty patients were selected, and two teeth of each participant (n = 40) were analyzed, regardless of the quadrant and the area irradiated, at four different time points: TP1, before RI; TP2, at the beginning of RI with radiation doses between 30 and 35 Gy; TP3, at the end of RI with radiation dose! between 60 and 70 Gy; and TP4, 4 to 5 months after the beginning of cancer treatment. Results: Mean %SpO(2) at the different time points were 93% (TP1), 83% (TP2), 77% (TP3), and 85% (TP4). The Student`s t test showed statistically significant differences between TP1 and TP2 (P < .01), TP3 (P <.01), and TP4 (P <.01). TP3 was also statistically significantly different when compared with TP2 (P <.01) and TP4 (P <.01). No statistically significant difference could be observed between TP2 and TP4. Conclusion`s: Because the mean %SpO(2) before RI was greater than during and after therapy and values obtained 4 to 5 months after the beginning of RI were close to the initiation of RI, pulp tissue may be able to regain normal blood flow after RT. If the changes in the microcirculation of the dental pulp were indeed transitory, preventive endodontic treatment or extraction in patients who are currently undergoing or recently received RI and who show negative signs of pulp sensitivity may rot be necessary for pulpal reasons. (J Endod 2011;37:1197-1200)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the performances of observers in diagnosing proximal caries in digital images obtained from digital bitewing radiographs using two scanners and four digital cameras in Joint Photographic Experts Group (JPEG) and tagged image file format (TIFF) files, and comparing them with the original conventional radiographs. Method: In total, 56 extracted teeth were radiographed with Kodak Insight film (Eastman Kodak, Rochester, NY) in a Kaycor Yoshida X-ray device (Kaycor X-707;Yoshida Dental Manufacturing Co., Tokyo, Japan) operating at 70 kV and 7 mA with an exposure time of 0.40 s. The radiographs were obtained and scanned by CanonScan D646U (Canon USA Inc., Newport News, VA) and Genius ColorPage HR7X (KYE Systems Corp. America, Doral, FL) scanners, and by Canon Powershot G2 (Canon USA Inc.), Canon RebelXT (Canon USA Inc.), Nikon Coolpix 8700 (Nikon Inc., Melville, NY), and Nikon D70s (Nikon Inc.) digital cameras in JPEG and TIFF formats. Three observers evaluated the images. The teeth were then observed under the microscope in polarized light for the verification of the presence and depth of the carious lesions. Results: The probability of no diagnosis ranged from 1.34% (Insight film) to 52.83% (CanonScan/JPEG). The sensitivity ranged from 0.24 (Canon RebelXT/JPEG) to 0.53 (Insight film), the specificity ranged from 0.93 (Nikon Coolpix/JPEG, Canon Powershot/TIFF, Canon RebelXT/JPEG and TIFF) to 0.97 (CanonScan/TIFF and JPEG) and the accuracy ranged from 0.82 (Canon RebelXT/JPEG) to 0.91 (CanonScan/JPEG). Conclusion: The carious lesion diagnosis did not change in either of the file formats (JPEG and TIFF) in which the images were saved for any of the equipment used. Only the CanonScan scanner did not have adequate performance in radiography digitalization for caries diagnosis and it is not recommended for this purpose. Dentomaxillofacial Radiology (2011) 40, 338-343. doi: 10.1259/dmfr/67185962

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ao longo dos últimos anos, os scanners 3D têm tido uma utilização crescente nas mais variadas áreas. Desde a Medicina à Arqueologia, passando pelos vários tipos de indústria, ´e possível identificar aplicações destes sistemas. Essa crescente utilização deve-se, entre vários factores, ao aumento dos recursos computacionais, à simplicidade e `a diversidade das técnicas existentes, e `as vantagens dos scanners 3D comparativamente com outros sistemas. Estas vantagens são evidentes em áreas como a Medicina Forense, onde a fotografia, tradicionalmente utilizada para documentar objectos e provas, reduz a informação adquirida a duas dimensões. Apesar das vantagens associadas aos scanners 3D, um factor negativo é o preço elevado. No âmbito deste trabalho pretendeu-se desenvolver um scanner 3D de luz estruturada económico e eficaz, e um conjunto de algoritmos para o controlo do scanner, para a reconstrução de superfícies de estruturas analisadas, e para a validação dos resultados obtidos. O scanner 3D implementado ´e constituído por uma câmara e por um projector de vídeo ”off-the-shelf”, e por uma plataforma rotativa desenvolvida neste trabalho. A função da plataforma rotativa consiste em automatizar o scanner de modo a diminuir a interação dos utilizadores. Os algoritmos foram desenvolvidos recorrendo a pacotes de software open-source e a ferramentas gratuitas. O scanner 3D foi utilizado para adquirir informação 3D de um crânio, e o algoritmo para reconstrução de superfícies permitiu obter superfícies virtuais do crânio. Através do algoritmo de validação, as superfícies obtidas foram comparadas com uma superfície do mesmo crânio, obtida por tomografia computorizada (TC). O algoritmo de validação forneceu um mapa de distâncias entre regiões correspondentes nas duas superfícies, que permitiu quantificar a qualidade das superfícies obtidas. Com base no trabalho desenvolvido e nos resultados obtidos, é possível afirmar que foi criada uma base funcional para o varrimento de superfícies 3D de estruturas, apta para desenvolvimento futuro, mostrando que é possível obter alternativas aos métodos comerciais usando poucos recursos financeiros.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Connaître les derniers développements techniques dans l'exploration de l'embolie pulmonaire aigue en imagerie (scanner et IRM). Connaître l'intérêt de la probabilité clinique pré-test dans l'indication de l'imagerie. Savoir faire une interprétation intégrée du scanner dans de l'embolie pulmonaire aiguë. Connaître chez les particularités de réalisation d'un examen chez la femme enceinte. Messages à retenir: Le scanner reste indiqué si les D-dimers sont négatifs et la probabilité clinique pré-test d'une embolie pulmonaire aiguë est élevée. Le scanner a une valeur diagnostique mais aussi une valeur pronostique dans la stratification du risque d'événement fatal chez les patients porteurs d'une embolie pulmonaire aiguë. Résumé: Durant la dernière décennie, l'imagerie en coupe s'est imposée comme moyen diagnostique incontournable dans l'embolie pulmonaire aiguë (EPA). Les nouveaux développements techniques ainsi que les récentes études ont contribué à mieux définir la valeur diagnostique du scanner et de l'IRM. En particulier, trois questions méritent d'être discutées : La probabilité clinique pré-test a-t-elle une importance dans l'indication de l'imagerie? ; (2) Faut-il synchroniser le scanner au rythme cardiaque devant une suspicion d'EPA ? ; (3) Quelles précautions faut-il prendre chez la femme enceinte ? Par ailleurs, La valeur pronostique du scanner mérite d'être connue et utilisée à bon escient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multidetector row computed tomography (MDCT) is the imaging modality of reference for the diagnosis of bronchiectasis. MDCT may also detect a focal stenosis, a tumor or multiple morphologic abnormalities of the bronchial tree. It may orient the endoscopist towards the abnormal bronchi, and in all cases assess the extent of the bronchial lesions. The CT findings of bronchial abnormalities include anomalies of bronchial division and origin, bronchial stenosis, bronchial wall thickening, lumen dilatation, and mucoid impaction. The main CT features of bronchiectasis are increased bronchoarterial ratio, lack of bronchial tapering, and visibility of peripheral airways. Other bronchial abnormalities include excessive bronchial collapse at expiration, outpouchings and diverticula, dehiscence, fistulas, and calcifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La radiologie post-­‐mortem a suivi les développements de la radiologie conventionnelle depuis ses débuts. De nos jours, ce sont les dernières techniques de radiologie qui prennent de plus en plus de place en médecine légale, avec les nouveaux outils que sont le scanner et l'imagerie par résonance magnétique. Le centre universitaire romand de médecine légal (CURML) à Lausanne réalise ainsi de façon systématique un examen tomodensitométrique (TDM) complet de chaque corps avant l'autopsie depuis 2008. Cette étude cherche à éprouver l'utilité de la nouvelle méthode de l'imagerie tomodensitométrique dans la détection des fractures de la face par rapport à l'autopsie, méthode traditionnelle. Pour ce faire, les constatations des rapports d'autopsie ont été comparées à celles des rapports de radiologie tomodensitométrique si ces derniers existaient. Ces rapports d'autopsie ont d'abord été sélectionnés s'ils présentaient une forte suspicion de traumatisme facial. Les causes de décès non traumatiques pour la face ont d'abord été exclues (noyade, strangulation volontaire, intoxication, etc.). Les causes les plus traumatiques (accidents de la voie publique, arme à feu, hétéro-­‐agression, etc.) ont été retenues dans un premier temps. Par la suite, les dossiers n'ont pas été retenus si l'autopsie faisait état de lésions traumatiques ne concernant pas la face ou de lésions bénignes de la face. Les constatations des rapports d'autopsie ont finalement été comparées avec ces rapports de radiologie tomodensitométriques s'ils existaient, soit 69 dossiers. Dans un deuxième temps, une seconde lecture des images radiologiques a été effectuée par un radiologue formé. Sur les 146 fractures répertoriées parmi les 69 dossiers restant, 62 (42,4%) ont été décrites à l'autopsie et à la radiologie. 42 (28,8%) ont été décrites dans le rapport d'autopsie uniquement et 42 (28,8%) par la radiologie uniquement. Parmi toutes les fractures de la face détectées uniquement à l'autopsie, toutes sauf une seule ont été retrouvées sur les images d'archive par un radiologue formé. La contribution dans le processus diagnostique de chacune de ces fractures, notée sur une échelle de 1 à 6 par deux médecins-­‐légistes expérimentés, est légère (notes de 1 à 2 dans 98% des cas) concernant la cause du décès. En revanche, concernant les circonstances du décès, on observe une différence entre les deux examinateurs avec des notes de 5 à 6 dans 77% des cas chez l'un, et 19% chez l'autre examinateur. Les deux examinateurs ne sont pas d'accord au sujet de l'importance des fractures dans les cas de traumatismes à haute énergie, l'un jugeant qu'elles sont alors évidentes et l'autre qu'elles permettent d'en savoir plus sur la force exacte de l'impact considéré. Cependant, bien que les fractures de la face ne contribuent que modestement au processus judiciaire suivant un décès, notre étude permet de démontrer la performance de la méthode de l'imagerie tomodensitométrique dans la détection desdites fractures par rapport à l'autopsie avec un taux de détection supérieur.