996 resultados para Sample losses


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The tissue microarray (TMA) technique allows multiple tissue samples in a single block. Commercial adhesive tape is used to avoid the loss of tissue samples during the immunostaining process. Few reports exist in the literature comparing the use of these adhesive tapes to other adhesive techniques. The objective of this study was to compare loss of sections adhered to slides using commercial adhesive tapes versus using silanized only slides. TMA was constructed with varying tissues using a fixed-base device (Beecher Instruments), placing 108 cylinders of 1 mm diameter in duplicate, spaced 1.2 mm apart. Section of 4 mu m were cut from the TMA block and adhered to 30 silanized slides and 30 commercial glass slides using adhesive tape, according to manufacturer's recommendations. Vimentin immunoexpression was evaluated by immunohistochemistry. Antigenic recovery was realized in citrate buffer using a microwave oven. Cylinder loss in the immunohistochemical process was quantified and expressed as: total (>80%), almost complete (75-79%), or partial (50-74%). The commercial adhesive tape group presented lesser total loss (1.1 versus 6.4%), almost complete loss (2.2 versus 3.5%), and partial loss (2.1 versus 3.8%) than the silanized slide group (ANOVA, P < 0.05). The sum of total and almost complete losses in the silanized slide group was 9.9%, greater than the losses in slides using commercial adhesive tapes (3.3%) and less than reported and considered acceptable in the literature (10-30%). In conclusion, the use of silanized only slides presents very satisfactory results, requires less training, and reduces costs significantly, thus justifying their use in research.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die pneumatische Zerstäubung ist die häufigste Methode der Probenzuführung von Flüssigkeiten in der Plasmaspektrometrie. Trotz der bekannten Limitierungen dieser Systeme, wie die hohen Probenverluste, finden diese Zerstäuber aufgrund ihrer guten Robustheit eine breite Anwendung. Die flussratenabhängige Aerosolcharakteristik und pumpenbasierte Signalschwankungen limitieren bisher Weiterentwicklungen. Diese Probleme werden umso gravierender, je weiter die notwendige Miniaturisierung dieser Systeme fortschreitet. Der neuartige Ansatz dieser Arbeit basiert auf dem Einsatz modifizierter Inkjet-Druckerpatronen für die Dosierung von pL-Tropfen. Ein selbst entwickelter Mikrokontroller ermöglicht den Betrieb von matrixkodierten Patronen des Typs HP45 mit vollem Zugriff auf alle essentiellen Betriebsparameter. Durch die neuartige Aerosoltransportkammer gelang die effiziente Kopplung des Tropfenerzeugungssystems an ein ICP-MS. Das so aufgebaute drop-on-demand-System (DOD) zeigt im Vergleich zu herkömmlichen und miniaturisierten Zerstäubern eine deutlich gesteigerte Empfindlichkeit (8 - 18x, elementabhängig) bei leicht erhöhtem, aber im Grunde vergleichbarem Signalrauschen. Darüber hinaus ist die Flexibilität durch die große Zahl an Freiheitsgraden des Systems überragend. So ist die Flussrate über einen großen Bereich variabel (5 nL - 12,5 µL min-1), ohne dabei die primäre Aerosolcharakteristik zu beeinflussen, welche vom Nutzer durch Wahl der elektrischen Parameter bestimmt wird. Das entwickelte Probenzuführungssystem ist verglichen mit dem pneumatischen Referenzsystem weniger anfällig gegenüber Matrixeffekten beim Einsatz von realen Proben mit hohen Anteilen gelöster Substanzen. So gelingt die richtige Quantifizierung von fünf Metallen im Spurenkonzentrationsbereich (Li, Sr, Mo, Sb und Cs) in nur 12 µL Urin-Referenzmaterial mittels externer Kalibrierung ohne Matrixanpassung. Wohingegen beim pneumatischen Referenzsystem die aufwändigere Standardadditionsmethode sowie über 250 µL Probenvolumen für eine akkurate Bestimmung der Analyten nötig sind. Darüber hinaus wird basierend auf der Dosierfrequenz eines dualen DOD-Systems eine neuartige Kalibrierstrategie vorgestellt. Bei diesem Ansatz werden nur eine Standard- und eine Blindlösung anstelle einer Reihe unterschiedlich konzentrierter Standards benötigt, um eine lineare Kalibrierfunktion zu erzeugen. Zusätzlich wurde mittels selbst entwickelter, zeitlich aufgelöster ICP-MS umfangreiche Rauschspektren aufgenommen. Aus diesen gelang die Ermittlung der Ursache des erhöhten Signalrauschens des DOD, welches maßgeblich durch das zeitlich nicht äquidistante Eintreffen der Tropfen am Detektor verursacht wird. Diese Messtechnik erlaubt auch die Detektion einzeln zugeführter Tropfen, wodurch ein Vergleich der Volumenverteilung der mittels ICP-MS detektierten, gegenüber den generierten und auf optischem Wege charakterisierten Tropfen möglich wurde. Dieses Werkzeug ist für diagnostische Untersuchungen äußerst hilfreich. So konnte aus diesen Studien neben der Aufklärung von Aerosoltransportprozessen die Transporteffizienz des DOD ermittelt werden, welche bis zu 94 Vol.-% beträgt.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The mechanical harvesting is an important stage in the production process of soybeans and, in this process; the loss of a significant number of grains is common. Despite the existence of mechanisms to monitor these losses, it is still essential to use sampling methods to quantify them. Assuming that the size of the sample area affects the reliability and variability between samples in quantifying losses, this paper aimed to analyze the variability and feasibility of using different sizes of sample area (1, 2 and 3 m²) in quantifying losses in the mechanical harvesting of soybeans. Were sampled 36 sites and the cutting losses, losses by other mechanisms of the combine and total losses were evaluated, as well as the water content in seeds, straw distribution and crop productivity. Data were subjected to statistical analysis (descriptive statistics and analysis of variance) and Statistical Control Process (SCP). The coefficients of variation were similar for the three frames available. Combine losses showed stable behavior, whereas cutting losses and total losses showed unstable behavior. The frame size did not affect the quantification and variability of losses in the mechanical harvesting of soybeans, thus a frame of 1 m² can be used for determining losses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper presents a method for transmission loss charge allocation in deregulated power systems based on Relative Electrical Distance (RED) concept. Based on RED between the generator and load nodes and the predefined bilateral power contracts, charge evaluation is carried out. Generally through some power exchange mechanism a set of bilateral contracts are determined that facilitate bilateral agreements between the generation and distribution entities. In this paper the possible charges incurred in meeting loads like generation charge, transmission charge and charge due to losses are evaluated. Case studies have been carried out on a few practical equivalent systems. Due to space limitation results for a sample 5 bus system are presented considering ideal load/generation power contracts and deviated load/generation power contracts. Extensive numerical testing indicates that the proposed allocation scheme produces loss allocations that are appropriate and that behave in a physically reasonable manner.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper provides a description of a methodology used for quantitative assessment of post harvest losses in the Kainji Lake Fishery (Nigeria). The sample population was made up of 314 fisherfolk, 115 processors, 125 fish buyers and 111 fish sellers. For the determination of handling losses, 24,839 fishes weighing 2,389.31 kg belonging to 43 species were examined of which 10% by number and 9% by weight deteriorated at checking and 4% by number and 3% by weight at landing. Processing losses recorded 22% by number and 16% by weight deteriorated prior to and during smoking with the traditional 'Banda' kiln. During marketing, 16% of fish sold had deteriorated and 6% by weight of fish bought also deteriorated, mainly due to insect infestation during storage. Based on the 1995 yield estimate for Kainji Lake fishery, approximately 1000 tons of fish estimated at 80 million Naira were lost during handling alone. This figure would be much higher if the level of losses during processing and marketing are included. This assessment technique is recommended for use in obtaining quantifiable data on post harvest losses from other water bodies in Nigeria

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prawn meat which was never in contact with ice or water prior to freezing was frozen at -30°C and was studied up to six months of storage at -23°C for thawing losses and cooked characteristics of the thawed material. Thawing loss was nil in unwashed samples after three days of storage and it gradually increased to 6.6% after 6 months compared to 6.0 and 18.2% in the washed samples during the same periods. It is inferred that the high thawing losses observed in commercial frozen prawn meat immediately after freezing may be mainly an after effect of the water imbibed during the pre-freezing stages. During frozen storage, the changes in texture observed by sensory methods on the cooked product were more in the washed sample indicating that the imbibed water or constituents washed out of the tissue play an important role in textural changes in prawn meat during frozen storage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis examines the relationship between initial loss events and the corporate governance and earnings management behaviour of these firms. This is done using four years of corporate governance information spanning the report of an initial loss for companies listed on the UK Stock Exchange. An industry- and sizematched control sample is used in a difference-in-difference analysis to isolate the impact of the initial loss event during the period. It is reported that, in general, an initial loss motivates an improvement in corporate governance in those loss firms where a relative weakness existed prior to the loss and that these changes mainly occur before the initial loss is announced. Firms with stronger (i.e. better quality) corporate governance have less need to alter it in response to the loss. It is also reported that initial loss firms use positive abnormal accruals in the year before the loss in an attempt to defer/avoid the loss — the weaker corporate governance the more likely is it that loss firms manage earnings in this manner. Abnormal accruals are also found to be predictive of an initial loss and when used as a conditioning variable, the quality of corporate governance is an important mitigating factor in this regard. Once the loss is reported, loss firms unwind these abnormal accruals although no evidence of big-bath behaviour is found. The extent to which these abnormal accruals are subsequently unwound are also found to be a function of both the quality of corporate governance as well as the severity of the initial loss.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Malaysian Financial Reporting Standard (FRS) No. 136, Impairment of Assets, was issued in 2005. The standard requires public listed companies to report their non-current assets at no more than their recoverable amount. When the value of impaired assets is recovered, or partly recovered, FRS 136 requires the impairment charges to be reversed to its new recoverable amount. This study tests whether the reversal of impairment losses by Malaysian firms is more closely associated with economic reasons or reporting incentives. The sample of this study consists of 182 public companies listed on Bursa Malaysia (formerly known as the Kuala Lumpur Stock Exchange) that reported reversals of their impairment charges during the period 2006-2009. These firms are matched with firms which do not reverse impairment on the basis of industrial classification and size. In the year of reversal, this study finds that the reversal firms are more profitable (before reversals) than their matched firms. On average, the Malaysian stock market values the reversals of impairment losses positively. These results suggest that the reversals generally reflect increases in the value of the previously impaired assets. After partitioning firms that are likely to manage earnings and those that are not, this study finds that there are some Malaysian firms which reverse the impairment charges to manage earnings. Their reversals are not value-relevant, and are negatively associated with future firm performance. On the other hand, the reversals of firms which are deemed not to be earnings managers are positively associated with both future firm performance and current stock price performance, and this is the dominant motivation for the reversal of impairment charges in Malaysia. In further analysis, this study provides evidence that the opportunistic reversals are also associated with other earnings management manifestations, namely abnormal working capital accruals and the motivation to avoid earnings declines. In general, the findings suggest that the fair value measurement in impairment standard provides useful information to the users of financial statements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tests are described showing the results obtained for the determination of REE and the trace elements Rb, Y, Zr, Nb, Cs, Ba, Hf, Ta, Pb, Th and U with ICP-MS methodology for nine basaltic reference materials, and thirteen basalts and amphibolites from the mafic-ultramafic Niquelandia Complex, central Brazil. Sample decomposition for the reference materials was performed by microwave oven digestion (HF and HNO(3), 100 mg of sample), and that for the Niquelandia samples also by Parr bomb treatment (5 days at 200 degrees C, 40 mg of sample). Results for the reference materials were similar to published values, thus showing that the microwave technique can be used with confidence for basaltic rocks. No fluoride precipitates were observed in the microwave-digested solutions. Total recovery of elements, including Zr and Hf, was obtained for the Niquelandia samples, with the exception of an amphibolite. For this latter sample, the Parr method achieved a total digestion, but not so the microwave decomposition; losses, however, were observed only for Zr and Hf, indicating difficulty in dissolving Zr-bearing minerals by microwave acid attack.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analysis of the performance of six major methods of loss allocation for generators and demands was conducted, based on pro-rata (two), on incremental factors (two), on proportional sharing (PS) (one), and on electric circuit theory (one). Using relatively simple examples which can easily be checked, the advantages and disadvantages of each were ascertained and the results confirmed using a larger sample system (IEEE-118). The discussion considers the location and size of generators and demands, as well as the merits of the location of these agents for each configuration based on an analysis of the effect of various network modifications. Furthermore, an application in the South-Southeastern Brazilian Systems is performed. Conclusions and recommendations are presented. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aufbau einer kontinuierlichen, mehrdimensionalen Hochleistungs-flüssigchromatographie-Anlage für die Trennung von Proteinen und Peptiden mit integrierter größenselektiver ProbenfraktionierungEs wurde eine mehrdimensionale HPLC-Trennmethode für Proteine und Peptide mit einem Molekulargewicht von <15 kDa entwickelt.Im ersten Schritt werden die Zielanalyte von höhermolekularen sowie nicht ionischen Bestandteilen mit Hilfe von 'Restricted Access Materialien' (RAM) mit Ionenaustauscher-Funktionalität getrennt. Anschließend werden die Proteine auf einer analytischen Ionenaustauscher-Säule sowie auf Reversed-Phase-Säulen getrennt. Zur Vermeidung von Probenverlusten wurde ein kontinuierlich arbeitendes, voll automatisiertes System auf Basis unterschiedlicher Trenngeschwindigkeiten und vier parallelen RP-Säulen aufgebaut.Es werden jeweils zwei RP-Säulen gleichzeitig, jedoch mit zeitlich versetztem Beginn eluiert, um durch flache Gradienten ausreichende Trennleistungen zu erhalten. Während die dritte Säule regeneriert wird, erfolgt das Beladen der vierte Säule durch Anreicherung der Proteine und Peptide am Säulenkopf. Während der Gesamtanalysenzeit von 96 Minuten werden in Intervallen von 4 Minuten Fraktionen aus der 1. Dimension auf die RP-Säulen überführt und innerhalb von 8 Minuten getrennt, wobei 24 RP-Chromatogramme resultieren.Als Testsubstanzen wurden u.a. Standardproteine, Proteine und Peptide aus humanem Hämofiltrat sowie aus Lungenfibroblast-Zellkulturüberständen eingesetzt. Weiterhin wurden Fraktionen gesammelt und mittels MALDI-TOF Massenspektrometrie untersucht. Bei einer Injektion wurden in den 24 RP-Chromatogrammen mehr als 1000 Peaks aufgelöst. Der theoretische Wert der Peakkapazität liegt bei ungefähr 3000.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sample size calculations are advocated by the CONSORT group to justify sample sizes in randomized controlled trials (RCTs). The aim of this study was primarily to evaluate the reporting of sample size calculations, to establish the accuracy of these calculations in dental RCTs and to explore potential predictors associated with adequate reporting. Electronic searching was undertaken in eight leading specific and general dental journals. Replication of sample size calculations was undertaken where possible. Assumed variances or odds for control and intervention groups were also compared against those observed. The relationship between parameters including journal type, number of authors, trial design, involvement of methodologist, single-/multi-center study and region and year of publication, and the accuracy of sample size reporting was assessed using univariable and multivariable logistic regression. Of 413 RCTs identified, sufficient information to allow replication of sample size calculations was provided in only 121 studies (29.3%). Recalculations demonstrated an overall median overestimation of sample size of 15.2% after provisions for losses to follow-up. There was evidence that journal, methodologist involvement (OR = 1.97, CI: 1.10, 3.53), multi-center settings (OR = 1.86, CI: 1.01, 3.43) and time since publication (OR = 1.24, CI: 1.12, 1.38) were significant predictors of adequate description of sample size assumptions. Among journals JCP had the highest odds of adequately reporting sufficient data to permit sample size recalculation, followed by AJODO and JDR, with 61% (OR = 0.39, CI: 0.19, 0.80) and 66% (OR = 0.34, CI: 0.15, 0.75) lower odds, respectively. Both assumed variances and odds were found to underestimate the observed values. Presentation of sample size calculations in the dental literature is suboptimal; incorrect assumptions may have a bearing on the power of RCTs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines investors' reactions to dividend reductions or omissions conditional on past earnings and dividend patterns for a sample of eighty-two U.S. firms that incurred an annual loss. We document that the market reaction for firms with long patterns of past earnings and dividend payouts is significantly more negative than for firms with lessestablished past earnings and dividends records. Our results can be explained by the following line of reasoning. First, consistent with DeAngelo, DeAngelo, and Skinner (1992), a loss following a long stream of earnings and dividend payments represents an unreliable indicator of future earnings. Thus, established firms have higher loss reliability than less-established firms. Second, because current earnings and dividend policy are a substitute source of means of forecasting future earnings, lower loss reliability increases the information content of dividend reductions. Therefore, given the presence of a loss, the longer the stream of prior earnings and dividend payments, (1) the lower the loss reliability and (2) the more reliably dividend cuts are perceived as an indication that earnings difficulties will persist in the future.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pesticides applications have been described by many researches as a very inefficient process. In some cases, there are reports that only 0.02% of the applied products are used for the effective control of the problem. The main factor that influences pesticides applications is the droplet size formed on spraying nozzles. Many parameters affects the dynamic of the droplets, like wind, temperature, relative humidity, and others. Small droplets are biologically more active, but they are affected by evaporation and drift. On the other hand, the great droplets do not promote a good distribution of the product on the target. In this sense, associated with the risk of non target areas contamination and with the high costs involved in applications, the knowledge of the droplet size is of fundamental importance in the application technology. When sophisticated technology for droplets analysis is unavailable, is common the use of artificial targets like water-sensitive paper to sample droplets. On field sampling, water-sensitive papers are placed on the trials where product will be applied. When droplets impinging on it, the yellow surface of this paper will be stained dark blue, making easy their recognition. Collected droplets on this papers have different kinds of sizes. In this sense, the determination of the droplet size distribution gives a mass distribution of the material and so, the efficience of the application of the product. The stains produced by droplets shows a spread factor proportional to their respectives initial sizes. One of methodologies to analyse the droplets is a counting and measure of the droplets made in microscope. The Porton N-G12 graticule, that shows equaly spaces class intervals on geometric progression of square 2, are coulpled to the lens of the microscope. The droplet size parameters frequently used are the Volumetric Median Diameter (VMD) and the Numeric Median Diameter. On VMD value, a representative droplets sample is divided in two equal parts of volume, in such away one part contains droplets of sizes smaller than VMD and the other part contains droplets of sizes greater that VMD. The same process is done to obtaining the NMD, which divide the sample in two equal parts in relation to the droplets size. The ratio between VMD and NMD allows the droplets uniformity evaluation. After that, the graphics of accumulated probability of the volume and size droplets are plotted on log scale paper (accumulated probability versus median diameter of each size class). The graphics provides the NMD on the x-axes point corresponding to the value of 50% founded on the y-axes. All this process is very slow and subjected to operator error. So, in order to decrease the difficulty envolved with droplets measuring it was developed a numeric model, implemented on easy and accessfull computational language, which allows approximate VMD and NMD values, with good precision. The inputs to this model are the frequences of the droplets sizes colected on the water-sensitive paper, observed on the Porton N-G12 graticule fitted on microscope. With these data, the accumulated distribution of the droplet medium volumes and sizes are evaluated. The graphics obtained by plotting this distributions allow to obtain the VMD and NMD using linear interpolation, seen that on the middle of the distributions the shape of the curves are linear. These values are essential to evaluate the uniformity of droplets and to estimate the volume deposited on the observed paper by the density (droplets/cm2). This methodology to estimate the droplets volume was developed by 11.0.94.224 Project of the CNPMA/EMBRAPA. Observed data of herbicides aerial spraying samples, realized by Project on Pelotas/RS county, were used to compare values obtained manual graphic method and with those obtained by model has shown, with great precision, the values of VMD and NMD on each sampled collector, allowing to estimate a quantities of deposited product and, by consequence, the quantities losses by drifty. The graphics of variability of VMD and NMD showed that the quantity of droplets that reachs the collectors had a short dispersion, while the deposited volume shows a great interval of variation, probably because the strong action of air turbulence on the droplets distribution, enfasizing the necessity of a deeper study to verify this influences on drift.