966 resultados para SPINAL-ANESTHESIA
Resumo:
To evaluate the efficacy and side-effects of fentanyl and sufentanil combined with hyperbaric spinal bupivacaine in elective cesarean section. A prospective, randomized, double-blind study with 64 term parturients, distributed into 2 groups according to the opioid combined with hyperbaric bupivacaine 0.5% (10mg): GF - fentanyl (25 µg) and GS - sufentanil (5.0 µg). The latency and maximum sensory block level; degree and duration of motor block; duration and quality of analgesia; maternal-fetal repercussions were evaluated. This was an intention-to-treat analysis with a 5% significance level. The latency period, maximum sensory block level, motor block degree and perioperative analgesia were similar in both groups. Motor block and analgesia had a longer duration in the sufentanil group. Maternal adverse effects and neonatal repercussions were similar. The incidence of hypotension was higher in the fentanyl group. In both groups, there was a predominance of patients who were awake and either calm or sleepy. The addition of fentanyl and sufentanil to hyperbaric subarachnoid bupivacaine was shown to be effective for the performance of cesarean section, and safe for the mother and fetus. Analgesia was more prolonged with sufentanil.
Resumo:
Nani FS, Torres MLA - Correlation between the Body Mass Index (BMI) of Pregnant Women and the Development of Hypotension after Spinal Anesthesia for Cesarean Section. Background and objectives: Very few publications correlate hypotension in obese pregnant women, and especially morbidly obese, after spinal anesthesia for cesarean section. The objective of the present study was to evaluate the incidence of hypotension according to the BMI. Methods: Forty-nine patients with pregestational BMI below 25 kg.m(-2) were included in the Eutrophia group, and 51 patients with BMI >= 25 kg.m(-2) were included in the Overweight group. After spinal anesthesia, blood pressure, volume of crystalloid infused, and dose of vasopressors used until delivery were recorded. A fall in systolic blood pressure below 100 mmHg or 10% reduction of the initial systolic blood pressure (SBP) was considered as hypotension and it was corrected by the administration of vasopressors. Results: Episodes of hypotension were fewer in the Eutrophia group (5.89 +/- 0.53 vs. 7.80 +/- 0.66, p = 0.027), as well as the amount of crystalloid administered (1,298 +/- 413.6 mL vs. 1,539 +/- 460.0 mL; p = 0.007), and use of vasopressors (5.87 +/- 3.45 bolus vs. 7.70 +/- 4.46 bolus; p = 0.023). As for associated diseases, we observed higher incidence of diabetes among obese pregnant women (29.41% vs. 9.76%, RR 1.60, 95%CI: 1.15-2.22, p = 0.036), however, differences in the incidence of pregnancy-induced hypertension (PIN) were not observe between both groups (overweight: 21.57%, normal weight: 12.20%, RR 1.30, 95%CI: 0.88-1.94, p = 0.28). Conclusions: In the study sample, pregestational BMI >= 25 kg.m(-2) was a risk factor for hypotension after spinal anesthesia in patients undergoing cesarean section. The same group of patients required higher doses of vasopressors. Those results indicate that the anesthetic techniques in those patients should be improved to reduce the consequences of post-spinal anesthesia hypotension, both in pregnant women and fetuses.
Resumo:
Bliacheriene F, Carmona MJC, Barretti CFM, Haddad CMF, Mouchalwat ES, Bortlotto MRFL, Francisco RPV, Zugaib M - Use of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases. Background and Objectives: Hemodynamic changes are observed during cesarean section under spinal anesthesia. Non-invasive blood pressure (BP) and heart rate (HR) measurements are performed to diagnose these changes, but they are delayed and inaccurate. Other monitors such as filling pressure and cardiac output (CO) catheters with external calibration are very invasive or inaccurate. The objective of the present study was to report the cardiac output measurements obtained with a minimally invasive uncalibrated monitor (LiDCO rapid) in patients undergoing cesarean section under spinal anesthesia. Case report: After approval by the Ethics Commission, four patients agreed to participate in this study. They underwent cesarean section under spinal anesthesia while at the same time being connected to the LiDCO rapid by a radial artery line. Cardiac output, HR, and BP were recorded at baseline, after spinal anesthesia, after fetal and placental extraction, and after the infusion of oxytocin and metaraminol. We observed a fall in BP with an increase of HR and CO after spinal anesthesia and oxytocin infusion; and an increase in BP with a fall in HR and CO after bolus of the vasopressor. Conclusions: Although this monitor had not been calibrated, it showed a tendency for consistent hemodynamic data in obstetric patients and it may be used as a therapeutic guide or experimental tool.
Resumo:
Effet d'un bolus intraveineux de phénylephrine ou d'éphedríne sur le flux sanguin cutané lors d'une anesthésie rachidienne Introduction : La phénylephrine et l'éphedrine sont des substances vaso-actives utilisées de routine pour corriger des épisodes d'hypotension artérielle induits par l'anesthésie intrarachidienne. L'influence de ces deux vasopresseurs sur le flux sanguin cutané (FSC) dans ce contexte n'a jusqu'à maintenant pas été décrite. Cette étude évalue l'effet d'une injection intraveineuse de 75 µg de phénylephrine ou de 7.5 mg d'éphedrine sur le FSC mesuré par Laser Doppler, dans les zones concernées parle bloc sympathiqué induit par l'anesthésie intrarachidienne (membres inférieurs) et dans les zones non concernées (membres supérieurs). Méthode :Après acceptation par le Comité d'Éthique, et obtention de leur accord écrit, 20 patients devant subir une intervention chirurgicale élective en décubitus dorsal sous anesthésie. intrarachidienne ont été inclus dans cette étude randomisée en double insu. Le FSC a été mesuré en continu par deux sondes fixées l'une à la cuisse (zone avec bloc sympathique) et l'autre sur l'avantbras (zone sans bloc sympathique). Les valeurs de FSC ont été enregistrées après l'anesthésie rachidienne (valeur contrôle), puis après l'injection i.v. dè phénylephrine (10 patients) ou d'éphedrine (10 patients) pour corriger une hypotension définie comme une chute de 20 mmHg de la pression artérielle systolique. Les variations de FSC exprimées en pourcentage de la valeur contrôle moyenne (+/- écart type) ont été analysées par le test t de Student. Résultats :Les données démographiques des patients et le niveau sensitif induit par l'anesthésie rachidienne sont similaires dans les deux groupes. Aux doses utilisées, seule l'éphedrine restaure la pression artérielle aux valeurs précédant l'anesthésie rachidienne. La phénylephrine augmente le FSC de l'avant-bras de 44% (+/- 79%) et de la cuisse de 34% (+/-24%), alors que l'éphedrine diminue le débit sanguin cutané de l'avant-bras de 16% (+/- 15%) et de la cuisse de 22% (+/-11%). Conclusion : L'injection intraveineuse de phénylephrine et d'éphedrine ont des effets opposés sur le flux sanguin cutané, et cette réponse n'est pas modifiée par le bloc sympathique.. Cette différence peut s'expliquer par la distribution des sous-types de récepteurs adrénergiques alpha et leur prédominance relative dans les veines et les artères de différents diamètres perfusant le tissu sous-cutané et la peau. L'éphedrine, èn raison de sa meilleure efficacité pour traiter les épisodes d'hypotension artérielle après anesthésie intrarachidienne devrait être préféré à la phénylephrine, leurs effets opposés sur le flux sanguin cutané n'étant pas pertinents en pratique clinique. SUMMARY Background: Phenylephrine or ephedrine is routinely used to correct hypotensive episodes fallowing spinal anaesthesia (SA). The influence of these two vasopressors on skin blood flow (SBF) has not yet been described. We have therefore evaluated the effects of an i.v. bolus of 75 µg phenylephrine or 7.5 mg of ephedrine on SBF measured by laser Doppler flowmetry during sympathetic blockade induced by SA. Methods: With Ethical Committee approval and written consent, 20 patients scheduled for elective procedures in supine position under SA were enrolled in this double-blind randomized study. SBF was measured continuously by two probes fixed at the thigh (area with sympathic blockade) and forearm level (area without sympathic blockade) respectively. SBF values were recorded after SA (control values) and then after a bolus administration of phenylephriné (n=10) or ephedrine (n=10) when systolic blood pressure decreased by 20 mmHg. Changes were expressed as percentage of control SBF values and analysed by Student's paired t-test. Results: Patient characteristics and dermatomal sensory levels were similar in both groups. Phenylephrine increases mean SBF at the forearm level by 44% (79%) [mean (SD)j and at the thigh by 34% (24%). Ephedrine decreases SBF at the forearm level by 16% (15%) and at the thigh by 22% (il%). Ephedrine bolus restores arterial blood pressure to pre-anaesthesia values, whereas phenylephrine does not. Conclusion: Administratión of phenylephrine and ephedrine has opposite effects on skin blood flow and sympathetic blockade does not modify this response. These findings could be explained by the distribution of the alpha-adrenoréceptor subtypes and their relative predominance among veins and arteries of different size perfusing the subcutaneous tissue and the skin. Ephedrine, due to its better efficacy to correct hypotensive episodes following SA, should be preferred, to phenylephrine, their opposite effects on SBF being not relevant for clinical practice.
Resumo:
CONTEXTO E OBJETIVO: Hipotermia inadvertida no perioperatório é freqüente durante anestesia subaracnóidea e após a administração de midazolam. O objetivo foi avaliar os efeitos do aquecimento da pele no intra-operatório, associado ou não ao aquecimento da pele durante o período de 45 minutos no pré-operatório, na prevenção de hipotermia intra- e pós-operatória determinada pela anestesia subaracnóidea em pacientes com medicação pré-anestésica com midazolam. TIPO DE ETUDO E LOCAL: Estudo prospectivo e aleatório, realizado no Hospital das Clínicas, Universidade Estadual Paulista (Unesp), Botucatu, SP. MÉTODOS: O estudo foi realizado em 30 pacientes com estado físico ASA (da Sociedade Norte-americana de Anestesiologistas) I e II submetidos à cirurgia eletiva do abdômen. Como medicação pré-anestésica, utilizou-se o midazolam, 7,5 mg via intramuscular (IM) e anestesia subaracnóidea padrão. em 10 pacientes (Gcontrole) utilizou-se isolamento térmico passivo; 10 pacientes (Gpré+intra) foram submetidos a aquecimento ativo no pré- e intra-operatório; e 10 pacientes (Gintra) foram aquecidos ativamente somente no intra-operatório. RESULTADOS: Após 45 minutos de aquecimento no pré-operatório, os pacientes do Gpré+intra apresentaram temperatura central mais elevada em relação aos dos grupos não aquecidos antes da anestesia (p < 0,05) mas não no início da cirurgia (p > 0,05). Os pacientes que receberam aquecimento no intra-operatório apresentaram temperatura central mais elevada no final da cirurgia em relação aos de Gcontrole (p < 0,05). Todos os pacientes estavam hipotérmicos na admissão da sala de recuperação pós-anestésica (temperatura central < 36º C). CONCLUSÕES: 45 minutos de aquecimento no pré-operatório combinado com aquecimento no intra- operatório não evita, mas minimiza a ocorrência de hipotermia determinada pela anestesia subaracnóidea em pacientes que receberam midazolam como medicação pré-anestésica.
Resumo:
Introduction. The postoperative acute renal failure (ARF) incidence in different kinds of surgery has rarely been studied. Age, cardiac dysfunction, previous renal dysfunction, intraoperative hypoperfusion, and use of nephrotoxic medications are mentioned as risk factors for ARF at the postoperative period. The postoperative ARF definition was based on the creatinine increase by the RIFLE classification (R = risk, I = injury, F = failure, L = loss, E = end stage), which corresponds to a 1.5 creatinine increase, two to three times, respectively, above the basal value. This study aimed to evaluate the postoperative ARF incidence in elderly patients who underwent femur fracture surgery under subarachnoid anesthesia and stratify it by the RIFLE criteria. Methods. Ninety patients older than 65 years under spinal anesthesia with fixed dosage of 15 mg of 0.5% isobaric bupivacaine associated with morphine 50 g were studied. Immediate postoperative creatinine was considered basal and compared with maximal creatinine evaluated at 24, 48, and 72 postoperative hours. Results. The mean age of the patients was 80.27 years. ARF incidence was 24.44% and stratified this way: R = 21.11% and I = 3.33%. Conclusions. In conclusion, the postoperative ARF incidence after femur fracture surgery in patients over 65 years was 24.44%. By analyzing the stratification based on the RIFLE classification, the incidence was categorized as Risk (R) = 21.11% and Injury (I) = 3.33%.
Resumo:
A 78 year old man with tetraparesis, reduced forced vital capacity, and neurogenic bladder dysfunction due to Guillain-Barré syndrome was admitted for elective transurethral prostate resection and percutaneous lithotripsy of a bladder stone. On the sixth postoperative day, he was readmitted for emergency evacuation of a clot in the bladder. Both operations were performed with spinal anesthesia (hyperbaric bupivacaine + fentanyl) without neurologic sequelae.
Resumo:
BACKGROUND: There are limited data about spinal dosing for cesarean delivery in preterm parturients. We investigated the hypothesis that preterm gestation is associated with an increased incidence of inadequate spinal anesthesia for cesarean delivery compared with term gestation. METHODS: We searched our perioperative database for women who underwent cesarean delivery under spinal or combined spinal-epidural anesthesia with hyperbaric bupivacaine ⩾10.5mg. The primary outcome was the incidence of inadequate surgical anesthesia needing conversion to general anesthesia or repetition or supplementation of the block. We divided patients into four categories: <28, 28 to <32, 32 to <37 and ⩾37weeks of gestation. The chi-square test was used to compare failure rates and a multivariable regression analysis was performed to investigate potential confounders of the relationship between gestational age and failure. RESULTS: A total of 5015 patients (3387 term and 1628 preterm) were included. There were 278 failures (5.5%). The incidence of failure was higher in preterm versus term patients (6.4% vs. 5.1%, P=0.02). Failure rates were 10.8%, 7.7%, 5.3% and 5% for <28, 28 to <32, 32 to <37 and ⩾37weeks of gestation, respectively. In the multivariable model, low birth weight (P<0.0001), gestational age (P=0.03), ethnicity (P=0.02) and use of combined spinal-epidural anesthesia (P<0.0001) were significantly associated with failure. CONCLUSIONS: At standard spinal doses of hyperbaric bupivacaine used in our practice (⩾10.5mg), there were higher odds of inadequate surgical anesthesia in preterm parturients. When adjusting for potential confounders, low birth weight was the main factor associated with failure.
Resumo:
Abrao J, Bianco MP, Roma W, Krippa JAS, Hallak JE - Spinal Myoclonus after Subarachnoid Anesthesia with Bupivacaine. Background and objectives: It is presented in this case report a very rare complication after spinal anesthesia to provide subsidies to the management and therapeutic conduct. Case report: This is a 63-year old African-Brazilian patient, ASA I, scheduled for transurethral resection of the prostate (TURP). He underwent subarachnoid anesthesia with bupivacaine (15 mg) without adrenaline. Intercurrences were not observed during puncture, and the patient was positioned for surgery. Soon after positioning the patient, he complained of severe pain in the perineum region followed by involuntary tonic-clonic movements of the lower limbs. The patient was treated with a benzodiazepine to control the myoclonus without response. This episode was followed by significant agitation and the patient was intubated. He was maintained in controlled ventilation and transferred to the Intensive Care Unit. Despite all biochemical and imaging tests performed, an apparent cause was not detected. The medication was not changed and the same batch of anesthetic had been used in other patients that same day without intercurrences. Conclusions: After ruling out all possible causes, the diagnosis of spinal myoclonus after spinal anesthesia with bupivacaine was made by exclusion.
Resumo:
The nerve supply of the human prostate is very abundant, and knowledge of the anatomy contributes to successful administration of local anesthesia. However, the exact anatomy of extrinsic neuronal cell bodies of the autonomic and sensory innervation of the prostate is not clear, except in other animals. Branches of pelvic ganglia composed of pelvic (parasympathetic) and hypogastric (sympathetic) nerves innervate the prostate. The autonomic nervous system plays an important role in the growth, maturation, and secretory function of this gland. Prostate procedures under local anesthesia, such as transurethral prostatic resections or transrectal ultrasound-guided prostatic biopsy, are safe, simple, and effective. Local anesthesia can be feasible for many special conditions including uncomplicated prostate surgery and may be particularly useful for the high-risk group of patients for whom inhalation or spinal anesthesia is inadvisable.
Resumo:
Introduction: The last twenty years has witnessed important changes in the field of obstetric analgesia and anesthesia. In 2007, we conducted a survey to obtain information regarding the clinical practice of obstetric anesthesia in our country. The main objective was to ascertain whether recent developments in obstetric anesthesia had been adequately implemented into current clinical practice. Methodology: A confidential questionnaire was sent to 391 identified wiss obstetric anesthetists. The questionnaire included 58 questions on 5 main topics: activity and organization of the obstetric unit, practice of labor analgesia, practice of anesthesia for caesarean section, prevention of aspiration syndrome, and pain treatment after cesarean section. Results: The response rate was 80% (311/391). 66% of the surveyed anesthetists worked in intermediate size obstetric units (500-1500 deliveries per year). An anesthetist was on site 24/24 hours in only 53% of the obstetric units. Epidural labor analgesia with low dose local anesthetics combined with opioids was used by 87% but only 30% used patient controlled epidural analgesia (PCEA). Spinal anesthesia was the first choice for elective and urgent cesarean section for 95% of the responders. Adequate prevention of aspiration syndrome was prescribed by 78%. After cesarean section, a multimodal analgesic regimen was prescribed by 74%. Conclusion: When comparing these results with those of the two previous Swiss surveys [1, 2], it clearly appears that Swiss obstetric anesthetists have progressively adapted their practice to current clinical recommendations. But this survey also revealed some insufficiencies: 1. Of the public health system: a. Insufficient number of obstetric anesthetists on site 24 hours/24. b. Lack of budget in some hospitals to purchase PCEA pumps. 2. Of individual medical practice: a. Frequent excessive dosage of hyperbaric bupivacaine during spinal anesthesia for cesarean section. b. Frequent use of cristalloid preload before spinal anesthesia for cesarean section. c. Frequent systematic use of opioids when inducing general anesthesia for cesarean section. d. Fentanyl as the first choice opioid during induction of general anesthesia for severe preeclampsia. In the future, wider and more systematic information campaigns by the mean of the Swiss Association of Obstetric Anesthesia (SAOA) should be able to correct these points.
Resumo:
CAUDA equina syndrome (CES) has long been recognized as a rare complication of spinal anesthesia.(1) CES has been described after administration of spinal anesthetics with lidocaine(2) and bupivacaine.(3) In 1991,(4) CES was reported after continuous spinal anesthesia with 1% tetracaine. In 1980, at our university hospital, six adult female patients underwent perineal gynecologic surgery using a spinal anesthetic of 2 ml tetracaine, 1.2%, in 10% glucose. The concentration of the injected tetracaine was unknown by the anesthetists. In all cases, lumbar puncture was performed at the L3-L4 interspace with a disposable spinal needle while the patients were in the sitting position. CES was first diagnosed 72 h or later postoperatively; previous diagnosis was not possible because patients had an indwelling urethral catheter. The diagnosis of CES was confirmed in all patients. During the past year, after institutional approval and informed consent, clinical, magnetic resonance imaging, electromyographic examinations, and conduction studies were performed in three of the above patients. Examinations were not possible on the other three patients because one had recently died, another could not be located, and the third refused to participate. T1 and T2 magnetic resonance image readings were obtained with Gadolinium contrast from a 0.5 Tesla General Electric apparatus (General Electric, Tokyo, Japan). Bilateral sensory and motor conduction studies of the sciatic nerve branches were obtained using a two-channel Nihon-Kohden Neuropack 2 (Nihom-Kohden Corporation, Tokyo, Japan). Electromyography was performed in accordance with conventional techniques.(5,6)
Resumo:
Background: Spinal anaesthesia is the standard of care for elective caesarean delivery. It has advantages over general anaesthesia. However the sympathetic blockade induced by spinal anaesthesia results in an 80 percent incidence of hypotension without prophylactic management. Current evidence supports co-loading with intravenous fluids in conjunction with the use of vasopressors as the most effective way to prevent and treat the hypotension. Phenylephrine is the accepted vasopressor of choice in the parturient. A prophylactic phenylephrine infusion combined with a fluid co-load is proven to be an effective and safe method of maintaining maternal hemodynamic stability. While most published studies have assessed the effectiveness of a prophylactic phenylephrine fixed dose infusion, few studies have assessed the effect of a prophylactic phenylephrine weight adjusted dose infusion on maintaining maternal hemodynamic stability following spinal anesthesia for a cesarean delivery. Objective: To compare the incidence of hypotension between women undergoing elective caesarean section under spinal anaesthesia, receiving prophylactic phenylephrine infusion at a fixed dose of 37.5 micrograms per minute versus a weight adjusted dose of 0.5 micrograms per kilogram per minute. Methods: One hundred and eight patients scheduled for non-urgent caesarean section under spinal anaesthesia were randomized into 2 groups; control group and intervention group using a computer generated table of numbers. Control group; Received prophylactic phenylephrine fixed dose infusion at 37.5 micrograms per minute. Intervention group; Received prophylactic phenylephrine weight adjusted dose infusion at 0.5 micrograms per kilogram per minute Results: The two groups had similar baseline characteristics in terms of ; Age, sex, weight and height. There was a 35.2% incidence of hypotension in the fixed dose group and an 18.6% incidence of hypotension in the weight adjusted dose group. This difference was found to be of borderline statistical significance p-value 0.05, and the difference in the incidence rates between the two groups was found to be statistically significant p= 0.03. The difference in the incidence of reactive hypertension and bradycardia between the two groups was not statistically significant: p-value of 0.19 for reactive hypertension and p-value of 0.42 for the incidence of bradycardia. There was also no statistically significant difference in the use of phenylephrine boluses, use of atropine, intravenous fluid used and the number of times the infusion was stopped. Conclusion: Among this population, the incidence of hypotension was significantly less in the weight adjusted dose group than in the fixed dose group. There was no difference in the number of physician interventions required to keep the blood pressure within 20% of baseline, and no difference in the proportion of reactive hypertension or bradycardia between the two groups. Administering prophylactic phenylephrine infusion at a weight adjusted dose of 0.5 micrograms per kilogram per minute results in a lower incidence of hypotension compared to its administration at a fixed dose of 37.5 micrograms per minute.
Resumo:
Atelectasis after either vaginal or Caesarean delivery has not been adequately quantified. This study addresses the hypothesis that atelectasis may be worse in women who undergo Caesarean section when compared with vaginal delivery under regional anaesthesia. Twenty healthy non-smoking women submitted to a chest computed tomography (CT) 2 h after delivery in a University Hospital, who had experienced vaginal delivery (n=10) under combined spinal-epidural analgesia or a Caesarean section (n=10) under spinal anaesthesia, were evaluated. The percentage cross-sectional area of atelectasis in dependent lung regions were measured from the CT images obtained at cross-section of the xiphoid process and the top of the diaphragm. The percentage cross-sectional area of atelectasis was 3.95% in the vaginal delivery group and 14.1% in the Caesarean group (P < 0.001, Mann-Whitney rank sum test). These results suggested that pulmonary atelectasis is greater after Caesarean section delivery under spinal anaesthesia than after vaginal delivery with combined spinal-epidural analgesia.
Resumo:
Abstract Study objective: The arousal state changes during spinal anesthesia. It is not clear if BIS and others devices could monitor the induced neuroaxial blockade sedation. Our objective was evaluate BIS and entropy values when spinal anesthesia is done. Design: We developed a prospective study. Patients: 40 patients were included in this study, ASA I-III, over 60 years old, undergoing spinal anesthesia, without premedication scheduled for orthopedics procedures. Intervention: Spinal anesthesia was performed with the unseated volunteer in the lateral decubitus position with a 25-gauge Whitacre needle at L2-L3 space, andanesthesia was done with 12 mg of 0.5% hyperbaric bupivacaine. Patients were positioned supine for 5 min after spinal anesthesia. Measurements: Observer’s Assessment of Alertness/Sedation OAA/S, response (RE) and state entropy (SE) and BIS, and standard hemodynamic measures. Main results: Statistical analysis were performed by Wilcoxon test or ANOVA, p<0.05 was considered statistically significant.RE and BIS showed a better correlation with the OAA/S scale values (Pk 0.81 and 0.82) than SE (Pk 0.69). The OAA/S, RE and SE showed significative differences from basal values after 30 min of neuroaxial anesthesia (ANOVA p<0.05). BIS showed differences after 40 min (ANOVA p<0.05). There were no differences between BIS and RE values along the study (ANOVA p>0.05). Conclusions: The spinal anesthesia decreased the cortical activity and these were founded by OAA/S scale and depth anesthetics monitors. OAA/S was a more sensitive value of this induced sedation. BIS and RE showed a better correlation with OAA/S scale than SE.