Monitoring of sedation during neuroaxial blockade.


Autoria(s): Guerrero Orriach, José Luis; Matute, Emilio; Alsina, Estíbaliz; Blanco, Brezo del; Gilsanz, Fernando
Data(s)

18/11/2013

18/11/2013

01/06/2013

Resumo

Abstract Study objective: The arousal state changes during spinal anesthesia. It is not clear if BIS and others devices could monitor the induced neuroaxial blockade sedation. Our objective was evaluate BIS and entropy values when spinal anesthesia is done. Design: We developed a prospective study. Patients: 40 patients were included in this study, ASA I-III, over 60 years old, undergoing spinal anesthesia, without premedication scheduled for orthopedics procedures. Intervention: Spinal anesthesia was performed with the unseated volunteer in the lateral decubitus position with a 25-gauge Whitacre needle at L2-L3 space, andanesthesia was done with 12 mg of 0.5% hyperbaric bupivacaine. Patients were positioned supine for 5 min after spinal anesthesia. Measurements: Observer’s Assessment of Alertness/Sedation OAA/S, response (RE) and state entropy (SE) and BIS, and standard hemodynamic measures. Main results: Statistical analysis were performed by Wilcoxon test or ANOVA, p<0.05 was considered statistically significant.RE and BIS showed a better correlation with the OAA/S scale values (Pk 0.81 and 0.82) than SE (Pk 0.69). The OAA/S, RE and SE showed significative differences from basal values after 30 min of neuroaxial anesthesia (ANOVA p<0.05). BIS showed differences after 40 min (ANOVA p<0.05). There were no differences between BIS and RE values along the study (ANOVA p>0.05). Conclusions: The spinal anesthesia decreased the cortical activity and these were founded by OAA/S scale and depth anesthetics monitors. OAA/S was a more sensitive value of this induced sedation. BIS and RE showed a better correlation with OAA/S scale than SE.

Errores del documento original. Autores: Guerrero OrriachJose Luis. Afiliación: PostgraduateResearch, Universidad Autónoma de Madrid, Facultad de Medicina, Spain. HospitalInfanta Leonor, Madrid, Spain. Citation: Luis GO, Emilio M, Estibaliz A, Brezo DB, Fernando G (2013) Monitoring of Sedation during Neuroaxial Blockade. J Anesthe Clinic Res 4: 324.

Identificador

Guerrero Orriach, Jose Luis; Matute, Emilio; Alsina, Estibaliz; Del Blanco, Brezo and Gilsanz, Fernando. Monitoring of sedation during neuroaxial blockade. Journal of Anesthesia and Clinical Research. 2013;4(6):4-6

2155-6148

http://hdl.handle.net/10668/1384

10.4172/2155-6148.10003324

Idioma(s)

en

Publicador

OMICS Publishing Group

Relação

Journal of Anesthesia and Clinical Research

http://www.omicsonline.org/monitoring-of-sedation-during-neuroaxial-blockade-2155-6148.10003324.php?aid=15484

Direitos

Acceso abierto

Palavras-Chave #Entropy #BIS #Neuroaxial #Hypnosis #Entropía #Hipnosis #Anestesia Epidural #Sedación Consciente #Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Anesthesia and Analgesia::Anesthesia::Anesthesia, Conduction::Anesthesia, Epidural #Medical Subject Headings::Analytical, Diagnostic and Therapeutic Techniques and Equipment::Anesthesia and Analgesia::Conscious Sedation #Medical Subject Headings::Psychiatry and Psychology::Behavioral Disciplines and Activities::Psychotherapy::Hypnosis #Medical Subject Headings::Phenomena and Processes::Physical Phenomena::Thermodynamics::Entropy #Medical Subject Headings::Organisms::Eukaryota::Animals::Chordata::Vertebrates::Mammals::Primates::Haplorhini::Catarrhini::Hominidae::Humans
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/published

Artículo