997 resultados para SI units
Resumo:
Visible photoluminescence (PL) and Raman spectra of Ge clusters embedded in porous silicon (PS) have been studied. The as-prepared sample shows redshifted and enhanced room temperature PL relative to reference PS. This result can be explained by the quantum confinement effect on excitons in Ge clusters and tunnel of excitons from Si units of the PS skeleton to Ge clusters. One year storage in dry air results in a pronounced decrease in PL intensity but blue-shifted in contrast to reference PS. This phenomenon correlates to the size decrease of macerated Ce clusters and occurrence of "quantum depletion" in Ge clusters. Consequently, only excitons in Si units contribute to PL. (C) 1998 American Institute of Physics.
Resumo:
Some aspects of the use and misuse of scientific language are discussed, particularly in relation to quantity calculus, the names and symbols for quantities and units, and the choice of units – including the possible use of non-SI units. The discussion is intended to be constructive, and to suggest ways in which common usage can be improved.
Resumo:
Integrated Ocean Drilling Program (IODP) Expedition 320 recovered high-quality paleomagnetic records with over 800 dated reversals and decimeter-scale cyclic sediments which provide an outstanding framework to inter-calibrate major fossil groups and refine magnetic polarity chrons for the early Miocene, the entire Oligocene and the late Eocene Epoch. In order to reconstruct the climate history of the Equatorial Pacific one of the major objectives of the Pacific Equatorial Age Transect (PEAT) is the compilation of a Cenozoic Megasplice which integrates all available bio-, chemo-, and magnetostratigraphic data including key records from Ocean Drilling Program (ODP) Leg 199. Here we present extended post-cruise refinements of the shipboard composite depth scales and composite records of IODP Expedition 320 Sites U1331, U1332, U1333, U1334 as well as ODP Leg 199 Sites 1218, 1219 and 1220. The revised composite records were used to perform a site-to-site correlation and integration of Leg 199 and Exp. 320 sites. Based on this decimeter scale correlation a high resolution integrated paleomagnetic and biostratigraphic framework for the Equatorial Pacific is established covering the time from 20 to 40 Ma. This unprecedented sedimentary compendium from the Equatorial Pacific will be the backbone for paleoceanographic reconstructions for the late Paleogene.
Resumo:
Die Rekonstruktion des Einflusses von Strömungen und glazialmarinen Prozessen auf das Sedimentationsgeschehen am Kontinentalhang der Antarktischen Halbinsel im westlichen Weddellmeer basiert auf sedimentologischen und geophysikalischen Daten eines Kolbenlotkerns. Der Sedimentkern wurde während des Fahrtabschnitts ANT-XIV/3 mit dem FS "Polarstern" aus einer mächtigen Levee-Struktur eines Rinnen-Rückensystems gewonnen. Es wurden sedimentologische sowie sedimentphysikalische Untersuchungen an dem Kernmaterial durchgeführt. Die texturellen Änderungen im Kern und die Variationen der gemessenen Parameter ermöglichen eine lithofazielle Gliederung und stratigraphische Einstufung der Sedimentabfolge. Die untersuchten Sedimente umfassen den Zeitraum der vier letzten Klimazyklen bis heute und repräsentieren die Ablagerungsbedingungen von mehr als 340 000 Jahren. Vier Faziestypen wurden unterschieden, die sowohl glaziale als auch interglaziale Ablagerungsräume charakterisieren. (1) Die überwiegend groblaminierten Sedimentabfolgen wurden der Laminitfazies zugeordnet. Unter glazialen Umweltbedingungen kam es infolge schwacher Bodenströmungen zur Ablagerung feinkörniger, laminierter, strömungsbetonter Sedimente. (2) Strukturlose, sehr homogene Sedimentabfolgen des Kems beschreiben einen weiteren, den Kaltzeiten zugeordneten, Faziestyp, der durch geringe Variationen in den Sedimenteigenschaften charakterisiert ist. (3) Kernabschnitte, die weitgehend strukturlos sind bzw. leichte Bioturbationen und relativ viel eistransportiertes Material aufweisen, wurden als IRD-Fazies bezeichnet. Sie repräsentiert den Übergang vom Glazial zum Interglazial, in dem sich das Schelfeis und die Meereisbeckung zurückzogen. In den Sedimenten kam es infolge der gesteigerten Kalbungsrate zur Anreicherung der Eisfracht. (4) Die relativ biogenreichen, hellen Ablagerungen wurden der interglazialzeitlichen Karbonatfazies zugeteilt. Der signifikant erhöhte Anteil planktischer Foraminiferen weist auf eine gesteigerte Bioproduktivität im Oberflächenwasser hin, die aus verstärkten jahreszeitlichen Schwankungen der Meereisbedeckung resultiert. Die betrachteten Sedimentationsprozesse, wie biologische Produktivität, Umlagerungsprozesse durch Meeresströmungen, gravitativer Sedimenttransport und Eistransport, sind das Abbild komplexer Wechselwirkungen aus Meeresspiegelschwankungen, Änderungen ozeanographischer Bedingungen und der Vereisungsdynamik. Das Sedimentationsgeschehen im Untersuchungsgebiet wurde folglich durch die Variationen der vorherrschenden Umweltbedingungen bestimmt. Im Glazial kam es unter einer geschlossenen Meereisbedeckung zur Ablagerung feinkörniger, geschichteter Sedimente. Vorwiegend Turbiditströmungen kontrollierten das Sedimentationsgeschehen innerhalb des betrachteten Rinnen-Rückensystems. Unter dem Einfluß der Coriolis-Kraft und wahrscheinlich einer Konturströmung wurden die suspendierten, feinkörnigen Partikel aus dem zentralen Bereich der Rinne verdriftet und über dem nördlichen Uferwall abgelagert. Höherenergetische gravitative Prozesse beeinflußten das Sedimentationsgeschehen episodisch und sind durch gut sortierte Ablagerungen mit erhöhten Gehalten im Mittel- bis Grobsiltbereich dokumentiert. Höhere Sedimentationsraten in den Glazialen trugen verstärkt zur Bildung des Uferwalls bei. Die Ablagerungen der ebenfalls glazialzeitlichen homogenen Fazies belegen unterschiedliche Ablagerungsbedingungen und eine Verschiebung der dominierenden Prozesse. Während des Übergangs vom Glazial zum Interglazial nahm die Bodenwasserbildungsrate durch das Aufschwimmen des Schelfeises zu, wodurch die Strömungsintensität gesteigert wurde. Eine verstärkte Eisbergaktivität wird durch die Anreichung des IRD-Materials dokumentiert. Während interglazialer Zeiten ermöglichten offen-marine Bedingungen im Südsommer eine leicht erhöhte biologische Produktivität, so daß der Ablagerungsraum durch die Sedimentation biogener Komponenten verstärkt beeinflußt wurde.
Resumo:
During Ocean Drilling Program Leg 134 (Vanuatu), geological high sensitivity magnetic tools (GHMT) developed by CEA-LETI and TOTAL were used at two drill sites. GHMT combine two sensors, a proton magnetometer for total magnetic field measurements with an operational accuracy of 0.1 nanoteslas (nT), and a highly sensitive induction tool to measure the magnetic susceptibility with an operational accuracy of a few 10**-6 SI units. Hole 829A was drilled through an accretionary prism and the downhole measurements of susceptibility correlate well with other well-log physical properties. Sharp susceptibility contrasts between chalk and volcanic silt sediment provide complementary data that help define the lithostratigraphic units. At Hole 831B magnetic susceptibility and total field measurements were performed through a 700-m reef carbonate sequence of a guyot deposited on top of an andesitic volcano. The downhole magnetic susceptibility is very low and the amplitude of peak-to-peak anomalies is less than a few 10**-5 SI units. Based on the repeatability of the measurements, the accuracy of the magnetic logging measurements was demonstrated to be excellent. Total magnetic field data at Hole 831B reveal low magnetic anomalies of 0.5 to 5 nT and the measurement of a complete repeat section indicates an accuracy of 0.1 to 0.2 nT. Due to the inclination of the earth's magnetic field in this area (~-40°) and the very low magnetic susceptibility of the carbonate, the contribution of the induced magnetization to the total field measured in the hole is negligible. Unfortunately, because the core recovery was extremely poor (<5%) no detailed comparison between the core measurements and the downhole magnetic data could be made. Most samples have a diamagnetic susceptibility and very low intensity of remanent magnetization (< 10**-4 A/m), but a few samples have a stable remanent magnetization up to 0.005 A/m. These variations of the intensity of the remanent magnetization suggest a very heterogeneous distribution of the magnetization in the carbonate sequence that could explain the magnetic field anomalies measured in these weakly magnetized rocks.
Resumo:
This collection of 359 data sets represents raw data of physical properties measurements on Polarstern sediment cores from both polar oceans, sampled and measured between 1985 and 1995.
Resumo:
During the expeditions ARK-VII/1, ARK-VII/3 and ARK-Xl2 sediment cores were taken by "RV Polarstern" from the shelf and the fjords of East Greenland and the Greenland Sea. The magnetic susceptibility and heavy mineral were determined at 48 surface sediment samples from undisturbed box cores. The main objective of this study was the identification of source areas and transport processes of terrigenous sediments at the East Greenland continental margin. The results can be summarized as lollows: 1a) Magnetic susceptibility in the North Atlantic is useful to detect delivery regions of the material transported by currents. b) The magnetic susceptibility is controlled by the ferromagnetic particles of the silt fraction. c) There are four important source areas: . The ferromagnetic particles of the box core PS2644-2 are transported from the Iceland Archipelago. . The material from the Geiki-Plateau effects the magnetic susceptibility in the Scoresby Sund Basin. . The magnetic susceptibility in the shelf regions in the North are produced by material from the fjords. . The ferromagnetic particles in the Greenland Sea are derived from the Mid Atlantic Ridges in the east. d) It is possible to determine the rock type, which delivers the ferromagnetic material because of differences in magnetic susceptibility of different intensity. . The erosion of the basalts of the Geiki-Plateau and the basalts of the Mid Atlantic ridges produce the high magnetic susceptibility in the south. . The magnetic susceptibility on the shelf in the north are probably produced by erosionproducts of the gneises of East Greenland. (2a) Heavy mineral assemblages show a significant difference between material transported by the Transpolar Drift from the Eurasian shelf regions (amphiboles, clinopyroxene, orthopyroxene) and material derived from East Greenland (garnets and opaque minerals). Transport via ice is dominant. b) lt is also possible to show different petrographic provenances (volcanic and metamorphic provenances). These associations verify the source areas. c) The information of heavy mineral composition gives no more detailed hint on the rock type or rock formation in the source area, due to mixing processes, large area of investigation and the sample quantity.
Resumo:
The Bureau International des Poids et Mesures, the BIPM, was established by Article 1 of the Convention du Mètre, on 20 May 1875, and is charged with providing the basis for a single, coherent system of measurements to be used throughout the world. The decimal metric system, dating from the time of the French Revolution, was based on the metre and the kilogram. Under the terms of the 1875 Convention, new international prototypes of the metre and kilogram were made and formally adopted by the first Conférence Générale des Poids et Mesures (CGPM) in 1889. Over time this system developed, so that it now includes seven base units. In 1960 it was decided at the 11th CGPM that it should be called the Système International d’Unités, the SI (in English: the International System of Units). The SI is not static but evolves to match the world’s increasingly demanding requirements for measurements at all levels of precision and in all areas of science, technology, and human endeavour. This document is a summary of the SI Brochure, a publication of the BIPM which is a statement of the current status of the SI. The seven base units of the SI, listed in Table 1, provide the reference used to define all the measurement units of the International System. As science advances, and methods of measurement are refined, their definitions have to be revised. The more accurate the measurements, the greater the care required in the realization of the units of measurement.
Resumo:
1974 ed. edited by C. H. Page and P. Vigoureux.
Resumo:
The mineral harmotome (Ba,Na,K)1-2(Si,Al)8O16⋅6H2O is a crystalline sodium calcium silicate which has the potential to be used in plaster boards and other industrial applications. It is a natural zeolite with catalytic potential. Raman bands at 1020 and 1102 cm−1 are assigned to the SiO stretching vibrations of three dimensional siloxane units. Raman bands at 428, 470 and 491 cm−1 are assigned to OSiO bending modes. The broad Raman bands at around 699, 728, 768 cm−1 are attributed to water librational modes. Intense Raman bands in the 3100 to 3800 cm−1 spectral range are assigned to OH stretching vibrations of water in harmotome. Infrared spectra are in harmony with the Raman spectra. A sharp infrared band at 3731 cm−1 is assigned to the OH stretching vibration of SiOH units. Raman spectroscopy with complimentary infrared spectroscopy enables the characterization of the silicate mineral harmotome.
Resumo:
The mineral meliphanite (Ca,Na)2Be[(Si,Al)2O6(F,OH)] is a crystalline sodium calcium beryllium silicate which has the potential to be used as piezoelectric material and for other ferroelectric applications. The mineral has been characterized by a combination of scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS) and vibrational spectroscopy. EDS analysis shows a material with high concentrations of Si and Ca and low amounts of Na, Al and F. Beryllium was not detected. Raman bands at 1016 and 1050 cm−1 are assigned to the SiO and AlOH stretching vibrations of three dimensional siloxane units. The infrared spectrum of meliphanite is very broad in comparison with the Raman spectrum. Raman bands at 472 and 510 cm−1 are assigned to OSiO bending modes. Raman spectroscopy identifies bands in the OH stretching region. Raman spectroscopy with complimentary infrared spectroscopy enables the characterization of the silicate mineral meliphanite.
Resumo:
The structure and operation of CdTe, CdZnTe and Si pixel detectors based on crystalline semiconductors, bump bonding and CMOS technology and developed mainly at Oy Simage Ltd. And Oy Ajat Ltd., Finland for X- and gamma ray imaging are presented. This detector technology evolved from the development of Si strip detectors at the Finnish Research Institute for High Energy Physics (SEFT) which later merged with other physics research units to form the Helsinki Institute of Physics (HIP). General issues of X-ray imaging such as the benefits of the method of direct conversion of X-rays to signal charge in comparison to the indirect method and the pros and cons of photon counting vs. charge integration are discussed. A novel design of Si and CdTe pixel detectors and the analysis of their imaging performance in terms of SNR, MTF, DQE and dynamic range are presented in detail. The analysis shows that directly converting crystalline semiconductor pixel detectors operated in the charge integration mode can be used in X-ray imaging very close to the theoretical performance limits in terms of efficiency and resolution. Examples of the application of the developed imaging technology to dental intra oral and panoramic and to real time X-ray imaging are given. A CdTe photon counting gamma imager is introduced. A physical model to calculate the photo peak efficiency of photon counting CdTe pixel detectors is developed and described in detail. Simulation results indicates that the charge sharing phenomenon due to diffusion of signal charge carriers limits the pixel size of photon counting detectors to about 250 μm. Radiation hardness issues related to gamma and X-ray imaging detectors are discussed.