972 resultados para Retenção em prótese total
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
The modalities of treatment with prostheses over implants for total edentulous patients can be divided in fixed and removable prostheses (overdentures). The fixed prostheses modality has proven to offer better results as to the functional aspects and, results in higher longevity. Overdentures are considered as a modality of rehabilitation utilized to compensate the need for better retention, aside from augmenting chewing efficiency. Its use is justified by its facilitated hygiene, reduced surgical and prosthetic costs, reestablishment of labial support and elimination of the possibility of air escape. However, this option presents psychosocial downside, since the fact that it is considered a removable rehabilitation modality does not please the majority of patients. Although many patients prefer a fixed implant-supported prosthesis to a removable overdenture, frequently it is necessary to utilize an implant retained overdenture as an alternative to the treatment, due to anatomical, physiological, aesthetic, hygienic, and financial limitations regarding the patient. The objective of this study was to discuss a clinical case of a partially edentulous patient treated in the Implantodontic Surgery Post-Graduation Course from the Kenedy Dentistry Institute Mozarteum/Famosp Unit – Goiânia-Brazil), and submitted to osseointegrated implants surgical fixation techniques. A modality of differential diagnosis was established after osseointegration period, it aimed at facilitating the choice of a rehabilitation model that could favor the patient’s and professional`s expectations. Therefore the appreciated aspects were function, comfort, aesthetics, and especially the patient satisfaction.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Estudo do desempenho em fadiga do componente tibial metálico de um modelo de prótese total de joelho
Resumo:
A substituição total de uma articulação de joelho é uma técnica amplamente usada para corrigir os danos irreversíveis na juntas originais, causadas por patologias como osteoartrite e artrite reumatóide. Com o aumento número de pacientes jovens e mais ativos, a evolução na técnica da substituição da articulação total de joelho visando desempenho de longo prazo passa a ser uma demanda crítica. Portanto, na tentativa de evitar as falhas prematuras e prolongar a vida em serviço como um todo, as modificações na bandeja tibial podem produzir erros fundamentais. O design da bandeja tibial é um importante fator, porque a sua fratura pode ocorrer em função de elementos geométricos da mesma, como raios de concordância e cantos vivos. A escolha do material e do processo de fabricação também são importantes. No tocante a rota de fabricação, pode ser visto que as ligas forjadas tem o maior limite de fadiga, se comparado com as obtidas pelo processo de fundição. Entretanto, a combinação das técnicas de desenho assistido por computador (CAD), engenharia assistida por computador (CAE) e manufatura assistida por computador (CAM) podem ser uma solução rápida e barata para alcançar melhores características das bandejas tibiais. Contudo, testes pré-clínicos devem ser executados para garantir que as bandejas tibiais não falharão prematuramente devido à fadiga. As técnicas de metalografia, microdureza e espectrometria foram empregadas neste trabalho com o objetivo de caracterizar metalurgicamente a liga de aço inoxidável atualmente empregada. A rugosidade superficial foi avaliada, assim como o número de ciclos para a iniciação das trincas. Com a utilização do método de elementos finitos, verificou-se o ponto de maior tensão e, aliado ao estudo de fractografia, foi determinado o modo de falha Os resultados indicaram que o material atualmente empregado não está em conformidade com todos os requisitos das normas vigentes, de forma que um material alternativo é sugerido. Com o objetivo de melhorar a resistência à fadiga sem apresentar problemas de ordem clínica, cinco geometrias foram propostas e os resultados da análise de tensões pelo método de elementos finitos indicaram um grande potencial de aumento da vida em fadiga.
Resumo:
Este trabalho avaliou comparativamente, em laboratório, a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), um poliéter (Impregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Para isto foi usado como corpo de prova um modelo metálico que simula um maxilar edêntulo, onde foram colocados quatro postes em forma do pirâmide, três truncadas, colocadas na crista do rebordo para medições horizontais, e uma inteira, que servia de referência para uma medição vertical. Com cada material ou técnica foram feitos dez moldes do modelo padrão, que foram vazados com gesso tipo IV. Os sessenta modelos obtidos, bem como o modelo-padrão, foram submetidos às medições das distâncias entre as referências situadas nas pirâmides, três medidas no sentido horizontal e uma no sentido vertical. Isto foi feito numa máquina para medição por coordenadas (tridimensionai), BRT-M507 fabricada pela Mitutoyo, com software Cosmos/Geopak-Win. Os resultados foram submetidos à analise de variância e testes complementares (Post Hoc Tests, de Duncan). A análise dos resultados mostra que quase todas as medidas no plano horizontal foram menores nas réplicas que no padrão, e que na medida vertical a discrepância entre os resultados foi maior, sendo umas medidas maiores e outras menores que no padrão. Estatisticamente, apenas numa das três distâncias avaliadas, Dist. 2, não houve diferença significativa entre os materiais. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo.
Resumo:
The maintenance of masticatory function is especially important for patients who wear complete dentures due to the limitations of this type of prosthesis. Thus, the bilateral balanced occlusion (BBO) is used to achieve, besides other advantages, greater masticatory efficiency. However, analyzing critically the literature, it is observed that there is not enough scientific evidence that support the BBO as the most appropriate occlusal concept in complete dentures. This way, the purpose of the present study was to verify if complete dentures wearers with BBO present better masticatory efficiency and capacity than those with canine guidance (CG). A double-blind controlled crossover clinical trial was conducted. The sample was made of 24 completely edentulous patients. The subjects wore sets of complete dentures with both occlusal concepts for equal periods of 3 months. Objective data were collected through the masticatory efficiency test, performed by the colorimetric method, in which capsules of a synthetic material enclosing fuchsine- containing granules were used. Subjective data were recorded by patient´s ratings of their chewing function, which is the masticatory ability. No significant statistical difference was found for masticatory efficiency (p=0,0952) and masticatory ability (x2=0,5711/ p=0,4498) between the two occlusal concepts studied, as well as there was no correlation between these two variables (p=0,2985). Based on these results, it seems reasonable to use CG for the setup of complete dentures, since it is an easier and quicker technical procedure, until that future researches can come to complement this question
Resumo:
The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.
Resumo:
The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In the present work it was studied the behavior of four water bath curing cycles of heat activated acrylic resin considered as long duration (I – 65ºC for 30 min;50ºC for 23h and 30min; and 100º C for 1h; II- 50ºC for 24h and the rapid cycle), compared to the known long time curing cycle (9 hours for 72ºC) and short curing cycle (1 h for 65ºC; 30 min to elevate at 100º C and 1:00 to 100º C). Analysis consisted of observations and verification of the residual monomer, weight alterations, dimensional, dimensional lineal, porosity and hardness to determine material performance. The results pointed out that residual monomer presented statistical significant differences in the factor storage and interaction among the factors cycle X storage for weight alteration; statistical significant differences for the factor storage for lineal dimensional alterations, without significant differences for hardness. Porosity was verified in minimum degree in the cycle III and in appreciable amount in the cycle IV
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
This paper presents a case report with the use of short dental implants and immediate prosthesis placement. After 13 months of follow-up, peri-implant probing values are near 1.87 mm and ISQ values around 78.56.