973 resultados para Retained airway secretions
Resumo:
There is currently no validated scoring system for quantification of airway secretions in children. A user friendly, valid scoring system of airway secretions during flexible bronchoscopy (FB) would be useful for comparative purposes in clinical medicine and research. The objective of this study was to validate our bronchoscopic secretion (BS) scoring system by examining the relationship between the amount of secretions seen at bronchoscopy with airway cellularity and microbiology. In 106 children undergoing FIB, the relationship of BS grades with bronchocalveolar lavage (BAL) cellularity and infective state (bacterial and viral infections) were examined using receptor operator curves (ROC). BAL was obtained according to European Respiratory Society guidelines; first lavage for microbiology and second lavage for cellularity Area under the ROC was significant for total cell count (TCC) and neutrophil % but not for lymphocyte %. BS grade significantly related to infection positive state (chi(2)(trend) = 5.85, P = 0,016). The area under the ROC for infection positive state versus BS grade was 0.645, 95% Cl 0.527-0.763. The BS scoring system is a valid method for quantifying airway secretions in children undergoing bronchoscopy The system related well to airway cellularity and neutrophilia, as well as to an airway infective state. However, the system is only complementary to cell counts and cultures and cannot replace these laboratory quantification techniques.
Resumo:
A retenção de secreções é um problema comum em pacientes sedados e ventilados invasivamente, estas são ponto de partida para o aparecimento de infecções, pneumonia nosocomial e agravamento geral do estado clínico do paciente. Apesar de estudos comprovarem a eficácia da fisioterapia respiratória convencional nestes doentes, outros demonstraram que é cara, operador dependente, de eficácia variada e por vezes causar desconforto e dor. Vários estudos que comprovaram a segurança e eficácia da Alta Frequência Oscilatória Extra Torácica serviram de base para a realização do estudo onde se avaliou os efeitos fisiológicos imediatos da aplicação da técnica e diferenças a médio e longo prazo na comparação entre dois grupos. O VestR força o ar para dentro e para fora dos pulmões aumentando a interacção fluxo/secreções reduzindo a sua viscosidade, ao libertar e mobilizar as secreções, estas são mais facilmente aspiradas, reduzindo o risco de infecção pulmonar. Dez pacientes que cumpriram critérios de inclusão entraram no estudo. Durante dois dias foi aplicado num dos grupos o VestR durante dez minutos, três vezes por dia. Foram registados os parâmetros ventilatórios, cardíacos e de oxigenação para avaliar efeitos fisiológicos imediatos. Para comparação de grupos foram efectuados registos durante as 48h dos parâmetros referidos anteriormente. No período de follow up foram registados os dias de internamento hospitalar na unidade de cuidados intensivos e os dias de ventilação mecânica invasiva. Pelo reduzido tamanho amostral foi usada a estatística descritiva para a análise dos dados. Não foram encontradas diferenças significativas entre os dois grupos, apesar de haver uma tendência de melhoria dos parâmetros fisiológicos imediatos durante a aplicação da técnica. Concluímos que, com a limitação do tamanho amostral, os efeitos positivos imediatos da aplicação da HFCWO neste grupo podem-se revelar um bom indício para a realização de estudos futuros, com tamanhos amostrais superiores e melhor controlados, que comprovem que é uma técnica mais vantajosa e eficaz para o tratamento dos doentes críticos.
Resumo:
BACKGROUND: Retention of airway secretions is a common and serious problem in ventilated patients. Treating or avoiding secretion retention with mucus thinning, patient-positioning, airway suctioning, or chest or airway vibration or percussion may provide short-term benefit. METHODS: In a series of laboratory experiments with a test-lung system we examined the role of ventilator settings and lung-impedance on secretion retention and expulsion. Known quantities of a synthetic dye-stained mucus simulant with clinically relevant properties were injected into a transparent tube the diameter of an adult trachea and exposed to various mechanical-ventilation conditions. Mucus-simulant movement was measured with a photodensitometric technique and examined with image-analysis software. We tested 2 mucus-simulant viscosities and various peak flows, inspiratory/ expiratory flow ratios, intrinsic positive end-expiratory pressures, ventilation waveforms, and impedance values. RESULTS: Ventilator settings that produced flow bias had a major effect on mucus movement. Expiratory How bias associated with intrinsic positive end-expiratory pressure generated by elevated minute ventilation moved mucus toward the airway opening, whereas intrinsic positive end-expiratory pressure generated by increased airway resistance moved the mucus toward the lungs. Inter-lung transfer of mucus simulant occurred rapidly across the ""carinal divider"" between interconnected test lungs set to radically different compliances; the mucus moved out of the low-compliance lung and into the high-compliance lung. CONCLUSIONS: The movement of mucus simulant was influenced by the ventilation pattern and lung impedance. Flow bias obtained with ventilator settings may clear or embed mucus during mechanical ventilation.
Resumo:
BACKGROUND: Recurrent airway obstruction (RAO) is a severe chronic respiratory disease affecting horses worldwide, though mostly in the Northern hemisphere. Environmental as well as genetic factors strongly influence the course and prognosis of the disease. Research has been focused on characterization of immunologic factors contributing to inflammatory responses, on genetic linkage analysis, and, more recently, on proteomic analysis of airway secretions from affected horses. The goal of this study was to investigate the interactions between eight candidate genes previously identified in a genetic linkage study and proteins expressed in bronchoalveolar lavage fluid (BALF) collected from healthy and RAO-affected horses. The analysis was carried out with Ingenuity Pathway Analysis(R) bioinformatics software. RESULTS: The gene with the greatest number of indirect interactions with the set of proteins identified is Interleukin 4 Receptor (IL-4R), whose protein has also been detected in BALF. Interleukin 21 receptor and chemokine (C-C motif) ligand 24 also showed a large number of interactions with the group of detected proteins. Protein products of other genes like that of SOCS5, revealed direct interactions with the IL-4R protein. The interacting proteins NOD2, RPS6KA5 and FOXP3 found in several pathways are reported regulators of the NFkappaB pathway. CONCLUSIONS: The pathways generated with IL-4R highlight possible important intracellular signaling cascades implicating, for instance, NFkappaB. Furthermore, the proposed interaction between SOCS5 and IL-4R could explain how different genes can lead to identical clinical RAO phenotypes, as observed in two Swiss Warmblood half sibling families because these proteins interact upstream of an important cascade where they may act as a functional unit.
Resumo:
Although premature infants are increasingly surviving the neonatal period, up to one-third develop bronchopulmonary dysplasia (BPD). Despite evidence that bacterial colonization of the neonatal respiratory tract by certain bacteria may be a risk factor in BPD development, little is known about the role these bacteria play. The aim of this study was to investigate the use of culture-independent molecular profiling methodologies to identify potential etiological agents in neonatal airway secretions. This study used terminal restriction fragment length polymorphism (T-RFLP) and clone sequence analyses to characterize bacterial species in endo-tracheal (ET) aspirates from eight intubated pre-term infants. A wide range of different bacteria was identified in the samples. Forty-seven T-RF band lengths were resolved in the sample set, with a range of 0-15 separate species in each patient. Clone sequence analyses confirmed the identity of individual species detected by T-RFLP. We speculate that the identification of known opportunistic pathogens including S. aureus, Enterobacter sp., Moraxella catarrhalis, Pseudomonas aeruginosa and Streptococcus sp., within the airways of pre-term infants, might be causally related to the subsequent development of BPD. Further, we suggest that culture-independent techniques, such as T-RFLP, hold important potential for the characterization of neonatal conditions, such as BPD.
Resumo:
Pós-graduação em Anestesiologia - FMB
Resumo:
The rate removal of nickel from the airway was measured in vivo. Removal in vivo was studied by intratracheal injection of nickel chloride solutions. Regardless of time after injection, the lungs and heart retained the greatest concentration of nickel and 40 days after 1.68 mumol administration they were the organs where nickel was still significantly measurable. The slow removal of nickel may indicate the presence of high affinity binding sites in the lung. Nickel can interact with others metals, such as copper and zinc, so that nickel exposure may have public health implications.
Resumo:
REASONS FOR PERFORMING STUDY: Although endoscopic scoring of the tracheal septum thickness is used as a diagnostic tool for evaluation of lower airway disease, its clinical relevance and reliability have never been critically assessed in the horse. OBJECTIVES: To investigate if septum thickness scores (STS) are reliable and serve as a clinically useful indicator of lower airway disease status and/or inflammation. METHODS: The variance of STS attributable to the horse, observer and changes over time was determined. The distribution of STS in a population of clinically normal horses and correlations of STS with age, gender, as well as mucus accumulation and cell differentials of tracheobronchial secretions and bronchoalveolar lavage fluid were investigated. Effects of altered pulmonary ventilation, induced by different drugs, on STS were assessed. Finally, STS of horses affected with recurrent airway obstruction (RAO) were compared to those of clinically normal horses. RESULTS: Recorded STS showed excellent intra- and satisfactory interobserver agreement Established clinical, endoscopic and cytological measures of lower airway inflammation, i.e. mucus accumulation scores and airway neutrophilia, did not correlate with STS. In horses age > or = 10 years, septum scores were significantly higher (P = 0.022) than in younger horses. Septum thickness scores did not differ significantly between clinically normal and RAO-affected horses both in exacerbation and in remission. Horses with markedly increased breathing effort (i.e. with metacholine- or lobeline hydrochloride-challenge), often differed markedly (up to 1.9 scores), but the average of end-inspiratory and end-expiratory STS did not differ from baseline STS. CONCLUSIONS AND CLINICAL RELEVANCE: Endoscopic STS are a reproducible measure, but STS did not correlate with clinical, endoscopic and cytological findings indicative of RAO or inflammatory airway disease.
Resumo:
Patients suffering from cystic fibrosis (CF) show thick secretions, mucus plugging and bronchiectasis in bronchial and alveolar ducts. This results in substantial structural changes of the airway morphology and heterogeneous ventilation. Disease progression and treatment effects are monitored by so-called gas washout tests, where the change in concentration of an inert gas is measured over a single or multiple breaths. The result of the tests based on the profile of the measured concentration is a marker for the severity of the ventilation inhomogeneity strongly affected by the airway morphology. However, it is hard to localize underlying obstructions to specific parts of the airways, especially if occurring in the lung periphery. In order to support the analysis of lung function tests (e.g. multi-breath washout), we developed a numerical model of the entire airway tree, coupling a lumped parameter model for the lung ventilation with a 4th-order accurate finite difference model of a 1D advection-diffusion equation for the transport of an inert gas. The boundary conditions for the flow problem comprise the pressure and flow profile at the mouth, which is typically known from clinical washout tests. The natural asymmetry of the lung morphology is approximated by a generic, fractal, asymmetric branching scheme which we applied for the conducting airways. A conducting airway ends when its dimension falls below a predefined limit. A model acinus is then connected to each terminal airway. The morphology of an acinus unit comprises a network of expandable cells. A regional, linear constitutive law describes the pressure-volume relation between the pleural gap and the acinus. The cyclic expansion (breathing) of each acinus unit depends on the resistance of the feeding airway and on the flow resistance and stiffness of the cells themselves. Special care was taken in the development of a conservative numerical scheme for the gas transport across bifurcations, handling spatially and temporally varying advective and diffusive fluxes over a wide range of scales. Implicit time integration was applied to account for the numerical stiffness resulting from the discretized transport equation. Local or regional modification of the airway dimension, resistance or tissue stiffness are introduced to mimic pathological airway restrictions typical for CF. This leads to a more heterogeneous ventilation of the model lung. As a result the concentration in some distal parts of the lung model remains increased for a longer duration. The inert gas concentration at the mouth towards the end of the expirations is composed of gas from regions with very different washout efficiency. This results in a steeper slope of the corresponding part of the washout profile.
Resumo:
Fluid and macromolecule secretion by submucosal glands in mammalian airways is believed to be important in normal airway physiology and in the pathophysiology of cystic fibrosis (CF). An in situ fluorescence method was applied to measure the ionic composition and viscosity of freshly secreted fluid from airway glands. Fragments of human large airways obtained at the time of lung transplantation were mounted in a humidified perfusion chamber and the mucosal surface was covered by a thin layer of oil. Individual droplets of secreted fluid were microinjected with fluorescent indicators for measurement of [Na+], [Cl−], and pH by ratio imaging fluorescence microscopy and viscosity by fluorescence recovery after photobleaching. After carbachol stimulation, 0.1–0.5 μl of fluid accumulated in spherical droplets at gland orifices in ≈3–5 min. In gland fluid from normal human airways, [Na+] was 94 ± 8 mM, [Cl−] was 92 ± 12 mM, and pH was 6.97 ± 0.06 (SE, n = 7 humans, more than five glands studied per sample). Apparent fluid viscosity was 2.7 ± 0.3-fold greater than that of saline. Neither [Na+] nor pH differed in gland fluid from CF airways, but viscosity was significantly elevated by ≈2-fold compared to normal airways. These results represent the first direct measurements of ionic composition and viscosity in uncontaminated human gland secretions and indicate similar [Na+], [Cl−], and pH to that in the airway surface liquid. The elevated gland fluid viscosity in CF may be an important factor promoting bacterial colonization and airway disease.
Resumo:
Excessive occlusal surface wear can result in occlusal disharmony, functional and esthetic impairment. As a therapeutic approach, conventional single crowns have been proposed, but this kind of treatment is complex, highly invasive and expensive. This case report describes the clinical outcomes of an alternative minimally invasive treatment based on direct adhesive-pin retained restorations. A 64-year-old woman with severely worn dentition, eating problems related to missing teeth and generalized tooth hypersensitivity was referred for treatment. Proper treatment planning based on the diagnostic wax-up simulation was used to guide the reconstruction of maxillary anterior teeth with direct composite resin over self-threading dentin pins. As the mandibular remaining teeth were extremely worn, a tooth-supported overdenture was installed. A stabilization splint was also used to protect the restorations. This treatment was a less expensive alternative to full-mouth rehabilitation with positive esthetic and functional outcomes after 1.5 years of follow-up.
Resumo:
A proper cast is essential for a successful rehabilitation with implant prostheses, in order to produce better structures and induce less strain on the implants. The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. A total of 40 casts were obtained from a metallic matrix simulating three unit implant-retained prostheses. The molds were filled using four different techniques in four groups (n = 10): Group 1 - Single-portion filling technique; Group 2 - Two-step filling technique; Group 3 - Latex cylinder technique; Group 4 - Joining the implant analogs previously to the mold filling. A titanium framework was obtained and used as a reference to evaluate the marginal misfit and tension forces in each cast. Vertical misfit was measured with an optical microscope with an increase of 120 times following the single-screw test protocol. Strain was quantified using strain gauges. Data were analyzed using one-way ANOVA (Tukey's test) (α =0.05). The correlation between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistical difference (P = 0.979), while the strain results showed statistical difference between Groups 3 and 4 (P = 0.027). The splinting technique was considered to be as efficient as the conventional technique. The strain gauge methodology was accurate for strain measurements and cast distortion evaluation. There was no correlation between strain and marginal misfit.
Resumo:
This study was designed to evaluate the correlation between computed tomography findings and data from the physical examination and the Friedman Staging System (FSS) in patients with obstructive sleep apnea (OSA). We performed a retrospective evaluation by reviewing the medical records of 33 patients (19 male and 14 female patients) with a mean body mass index of 30.38 kg/m(2) and mean age of 49.35 years. Among these patients, 14 presented with severe OSA, 7 had moderate OSA, 7 had mild OSA, and 5 were healthy. The patients were divided into 2 groups according to the FSS: Group A comprised patients with FSS stage I or II, and group B comprised patients with FSS stage III. By use of the Fisher exact test, a positive relationship between the FSS stage and apnea-hypopnea index (P = .011) and between the FSS stage and body mass index (P = .012) was found. There was no correlation between age (P = .55) and gender (P = .53) with the FSS stage. The analysis of variance test comparing the upper airway volume between the 2 groups showed P = .018. In this sample the FSS and upper airway volume showed an inverse correlation and were useful in analyzing the mechanisms of airway collapse in patients with OSA.
Resumo:
This article reports the case of a 55-year-old female patient who presented with unsatisfactory temporary crowns in the right mandibular premolars and molars, and a premolar-to-molar fixed partial denture in the left side. The clinical and radiographic examinations revealed a fracture of the left first premolar that was a retainer of the fixed partial denture and required extraction. Initially, the acrylic resin crowns were replaced by new ones, and a provisional RPD was made using acrylic resin and orthodontic wire clasps to resolve the problem arising from the loss of the fixed partial denture. Considering the patient's high esthetic demands, the treatment options for the definitive prosthetic treatment were discussed with her and rehabilitation with implant-supported dentures was proposed because the clinical conditions of the residual alveolar ridge were suitable for implant installation, and the patient's general health was excellent. However, the patient did not agree because she knew of a failed case of implant-retained denture in a diabetic individual and was concerned. The patient was fully informed that implant installation was the best indication for her case, but the arguments were not sufficient to change her decision. The treatment possibilities were presented and the patient opted for a clasp-retained removable partial denture (RPD) associated with the placement of crowns in the pillar teeth. The temporary RPD was replaced by the definitive RPD constructed subsequently. Although RPD was not the first choice, satisfactory esthetic and functional outcomes were achieved, overcaming the patient's expectations. This case report illustrates that the dentist must be prepared to deal with situations where, for reasons that cannot be managed, the patient does not accept the treatment considered as the most indicated for his/her case. Alternatives must be proposed and the functional and esthetic requirements must be fulfilled in the best possible manner.