929 resultados para Reagent Kits, Diagnostic


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapid diagnostic tests (RDT) are sometimes recommended to improve the home-based management of malaria. The accuracy of an RDT for the detection of clinical malaria and the presence of malarial parasites has recently been evaluated in a high-transmission area of southern Mali. During the same study, the cost-effectiveness of a 'test-and-treat' strategy for the home-based management of malaria (based on an artemisinin-combination therapy) was compared with that of a 'treat-all' strategy. Overall, 301 patients, of all ages, each of whom had been considered a presumptive case of uncomplicated malaria by a village healthworker, were checked with a commercial RDT (Paracheck-Pf). The sensitivity, specificity, and positive and negative predictive values of this test, compared with the results of microscopy and two different definitions of clinical malaria, were then determined. The RDT was found to be 82.9% sensitive (with a 95% confidence interval of 78.0%-87.1%) and 78.9% (63.9%-89.7%) specific compared with the detection of parasites by microscopy. In the detection of clinical malaria, it was 95.2% (91.3%-97.6%) sensitive and 57.4% (48.2%-66.2%) specific compared with a general practitioner's diagnosis of the disease, and 100.0% (94.5%-100.0%) sensitive but only 30.2% (24.8%-36.2%) specific when compared against the fulfillment of the World Health Organization's (2003) research criteria for uncomplicated malaria. Among children aged 0-5 years, the cost of the 'test-and-treat' strategy, per episode, was about twice that of the 'treat-all' (U.S.$1.0. v. U.S.$0.5). In older subjects, however, the two strategies were equally costly (approximately U.S.$2/episode). In conclusion, for children aged 0-5 years in a high-transmission area of sub-Saharan Africa, use of the RDT was not cost-effective compared with the presumptive treatment of malaria with an ACT. In older patients, use of the RDT did not reduce costs. The question remains whether either of the strategies investigated can be made affordable for the affected population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The MRSA-Screen test (Denka Seiken Co., Ltd., Tokyo, Japan), consisting of a slide latex agglutination kit that detects PBP 2a with a monoclonal antibody, was blindly compared to the oxacillin disk diffusion test, the oxacillin-salt agar screen, and PCR of the mecA gene for the detection of methicillin resistance in Staphylococcus aureus. A total of 120 methicillin-susceptible S. aureus (MSSA) and 80 methicillin-resistant S. aureus (MRSA) isolates, defined by the absence or presence of the mecA gene, respectively, were tested. The MRSA-Screen test, the oxacillin disk diffusion test, and the oxacillin-salt agar screening test showed sensitivities of 100, 61.3, and 82.5% and specificities of 99.2, 96.7, and 98.3%, respectively. We conclude that the MRSA-Screen is a very accurate, reliable, and fast test (15 min) for differentiation of MRSA from MSSA colonies on agar plates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The gacA gene of the biocontrol strain Pseudomonas fluorescens CHA0 codes for a response regulator which, together with the sensor kinase GacS (=LemA), is required for the production of exoenzymes and secondary metabolites involved in biocontrol, including hydrogen cyanide (HCN). A gacA multicopy suppressor was isolated from a cosmid library of strain CHA0 and identified as the infC-rpmI-rplT operon, which encodes the translation initiation factor IF3 and the ribosomal proteins L35 and L20. The efficiency of suppression was about 30%, as determined by the use of a GacA-controlled reporter construct, i.e. a translational hcnA'-'lacZ fusion. Overexpression of the rsmA gene (coding for a global translational repressor) reversed the suppressive effect of the amplified infC operon. This finding suggests that some product(s) of the infC operon can compete with RsmA at the level of translation in P. fluorescens CHA0 and that important biocontrol traits can be regulated at this level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tuberculin skin test (TST) has been used for 100 years for the diagnosis of latent tuberculosis (TB) infection (LTBI). In recent years, increasing interest in the diagnosis of TB has led to the development of new assays. QuantiFERON-TB Gold (QFT-G) is an IFN-gamma-release assay that measures the release of interferon after stimulation in vitro by Mycobacterium tuberculosis antigens. The main advantage of this assay with respect to TST is the lack of crossreaction with bacillus Calmette-Guérin and most nontuberculous mycobacteria. QFT-G also eliminates the need for the patient to return for test reading in 48-72 h. In the immunocompromised host and in pediatric populations, studies suggest that the QFT-G better correlates with the risk of TB than the TST, but data remain inconclusive. In contrast to TST, there are no prospective studies regarding the association of the QFT-G result and the risk for development of TB. Given its advantages, the QFT-G may become the standard test for the diagnosis of LTBI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: Reactivation of latent tuberculosis (TB) in inflammatory bowel disease (IBD) patients treated with antitumor necrosis factor-alpha medication is a serious problem. Currently, TB screening includes chest x-rays and a tuberculin skin test (TST). The interferon-gamma release assay (IGRA) QuantiFERON-TB Gold In-Tube (QFT-G-IT) shows better specificity for diagnosing TB than the skin test. This study evaluates the two test methods among IBD patients. METHODS: Both TST and IGRA were performed on 212 subjects (114 Crohn's disease, 44 ulcerative colitis, 10 indeterminate colitis, 44 controls). RESULTS: Eighty-one percent of IBD patients were under immunosuppressive therapy; 71% of all subjects were vaccinated with Bacille Calmette Guérin; 18% of IBD patients and 43% of controls tested positive with the skin test (P < 0.0001). Vaccinated controls tested positive more often with the skin test (52%) than did vaccinated IBD patients (23%) (P = 0.011). Significantly fewer immunosuppressed patients tested positive with the skin test than did patients not receiving therapy (P = 0.007); 8% of patients tested positive with the QFT-G-IT test (14/168) compared to 9% (4/44) of controls. Test agreement was significantly higher in the controls (P = 0.044) compared to the IBD group. CONCLUSIONS: Agreement between the two test methods is poor in IBD patients. In contrast to the QFT-G-IT test, the TST is negatively influenced by immunosuppressive medication and vaccination status, and should thus be replaced by the IGRA for TB screening in immunosuppressed patients having IBD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interferon-gamma release assays for the diagnosis of tuberculosis (TB) can give indeterminate results. The prevalence of indeterminate test results (ITRs) among T-SPOT.TB tests was assessed. A retrospective analysis of samples processed in 2005 was performed. ITRs were assessed by age, sex, immunosuppression, distance to the laboratory and season. A subgroup of tests performed for specific indications (contact tracing, migrants with positive tuberculin skin test, TB suspects and immunosuppression) were analysed separately. Of a total of 1,429 tests, 49 (3.4%) were indeterminate. ITRs were significantly associated with old age (>75 versus 5-75 yrs; odds ratio (OR) 7.97, 95% confidence interval (CI) 3.968-15.438) and the season during which samples were transported (autumn and winter versus spring and summer; OR 3.47, 95% CI 1.753-7.514). The incidence of ITR was 302 (2.0%) among TB contacts, 75 (1.6%) among immigrants, 156 (3.0%) in TB suspects and 32 (3.0%) among immunosuppressed patients. Sex, young age and distance to the laboratory were not associated with the rate of ITR. Of the 13 tests with ITR that were repeated, 10 gave a clear positive or negative result. Indeterminate test results with T-SPOT.TB under routine conditions were infrequent and more common in individuals aged >75 yrs than in children and younger adults. The incidence of indeterminate test results was low and similar among healthy tuberculosis contacts, immigrants with a positive tuberculin skin test, tuberculosis suspects and the immunosuppressed. The conditions of transportation may influence the incidence of indeterminate test results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Increased intracranial pressure (ICP) is a serious, life-threatening, secondary event following traumatic brain injury (TBI). In many cases, ICP rises in a delayed fashion, reaching a maximal level 48-96 hours after the initial insult. While pressure catheters can be implanted to monitor ICP, there is no clinically proven method for determining a patient's risk for developing this pathology. METHODS: In the present study, we employed antibody array and Luminex-based screening methods to interrogate the levels of inflammatory cytokines in the serum of healthy volunteers and in severe TBI patients (GCS RESULTS: Consistent with previous reports, we observed sustained increases in IL-6 levels in TBI patients irrespective of their ICP status. However, the group of patients who subsequently experienced ICP >or= 25 mm Hg had significantly higher IL-6 levels within the first 17 hours of injury as compared to the patients whose ICP remained 128 pg/ml correctly identified 85% of isolated TBI patients who subsequently developed elevated ICP, and values between these cut-off values correctly identified 75% of all patients whose ICP remained CONCLUSIONS: Our results suggest that serum IL-6 can be used for the differential diagnosis of elevated ICP in isolated TBI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional karyotyping detects anomalies in 3-15% of patients with multiple congenital anomalies and mental retardation (MCA/MR). Whole-genome array screening (WGAS) has been consistently suggested as the first choice diagnostic test for this group of patients, but it is very costly for large-scale use in developing countries. We evaluated the use of a combination of Multiplex Ligation-dependent Probe Amplification (MLPA) kits to increase the detection rate of chromosomal abnormalities in MCA/MR patients. We screened 261 MCA/MR patients with two subtelomeric and one microdeletion kits. This would theoretically detect up to 70% of all submicroscopic abnormalities. Additionally we scored the de Vries score for 209 patients in an effort to find a suitable cut-off for MLPA screening. Our results reveal that chromosomal abnormalities were present in 87 (33.3%) patients, but only 57 (21.8%) were considered causative. Karyotyping detected 15 abnormalities (6.9%), while MLPA identified 54 (20.7%). Our combined MLPA screening raised the total detection number of pathogenic imbalances more than three times when compared to conventional karyotyping. We also show that using the de Vries score as a cutoff for this screening would only be suitable under financial restrictions. A decision analytic model was constructed with three possible strategies: karyotype, karyotype + MLPA and karyotype + WGAS. Karyotype + MLPA strategy detected anomalies in 19.8% of cases which account for 76.45% of the expected yield for karyotype + WGAS. Incremental Cost Effectiveness Ratio (ICER) of MLPA is three times lower than that of WGAS, which means that, for the same costs, we have three additional diagnoses with MLPA but only one with WGAS. We list all causative alterations found, including rare findings, such as reciprocal duplications of regions deleted in Sotos and Williams-Beuren syndromes. We also describe imbalances that were considered polymorphisms or rare variants, such as the new SNP that confounded the analysis of the 22q13.3 deletion syndrome. (C) 2011 Elsevier Masson SAS. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Serum samples from 150 NS1-negative (Platelia ELISA) patients presumptively diagnosed with dengue were analyzed by the TaqMan probed real-time reverse transcription PCR (TaqMan qRT-PCR) method. The qRT-PCR positive samples were tested for serotype by semi-nested RT-PCR and a qualitative immunochromatographic assay for IgG and IgM. Molecular detection methods showed 33 (22%) positive samples out of 150 NS1-antigen negative samples. Of these, 72% were collected up to day 2 after the onset of symptoms, when diagnostic sensitivity of NS1-antigen test assays is significantly enhanced. Most of the cases were not characterized as secondary infection. Twenty-eight samples were successfully serotyped, 75% of which for DENV-4, 14% for DENV-2, 7% for DENV-3 and 4% for DENV-1. These findings reaffirm the hyperendemic situation of the state of Roraima and suggest a lower sensitivity of the NS1 test, mainly when DENV-4 is the predominant serotype. Health care providers should therefore be aware of samples tested negative by NS1 antigen assays, especially when clinical symptoms and other laboratory data results show evidence of dengue infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Activin A is a growth factor, produced by the endometrium, whose actions are modulated by the binding protein follistatin. Both proteins are detectable in the peripheral serum and their concentrations may be increased in women with endometriosis. The present study was designed to evaluate whether serum levels of activin A and follistatin are altered, and therefore have a potential diagnostic value, in women with peritoneal, ovarian and deep infiltrating endometriosis. We performed a multicenter controlled study evaluating simultaneously serum activin A and follistatin concentrations in women with and without endometriosis. Women with endometriosis (n 139) were subdivided into three groups: peritoneal endometriosis (n 28); ovarian endometrioma (n 61) and deep infiltrating endometriosis (n 50). The control group (n 75) consisted of healthy women with regular menstrual cycles. Blood samples were collected from a peripheral vein and assayed for activin A and follistatin using commercially available enzyme immunoassay kits. The ovarian endometrioma group had serum activin A levels significantly higher than healthy controls (0.22 0.01 ng/ml versus 0.17 0.01 ng/ml, P 0.01). None of the endometriosis groups had serum follistatin levels which were significantly altered compared with healthy controls; however, levels found in the endometrioma group (2.34 0.32 ng/ml) were higher than that in the deep endometriosis group (1.50 0.17 ng/ml, P 0.05). The area under the receiver operating characteristic curve of activin A was 0.700 (95 confidence interval: 0.6050.794), while that of follistatin was 0.620 (95 confidence interval: 0.5100.730) for the diagnosis of ovarian endometrioma. The combination of both markers into a duo marker index did not improve significantly their diagnostic accuracy. The present study demonstrated that serum activin A and follistatin are not significantly altered in peritoneal or deep infiltrating endometriosis and have limited diagnostic accuracy in the diagnosis of ovarian endometrioma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Medical microbiology and virology laboratories use nucleic acid tests (NAT) to detect genomic material of infectious organisms in clinical samples. Laboratories choose to perform assembled (or in-house) NAT if commercial assays are not available or if assembled NAT are more economical or accurate. One reason commercial assays are more expensive is because extensive validation is necessary before the kit is marketed, as manufacturers must accept liability for the performance of their assays, assuming their instructions are followed. On the other hand, it is a particular laboratory's responsibility to validate an assembled NAT prior to using it for testing and reporting results on human samples. There are few published guidelines for the validation of assembled NAT. One procedure that laboratories can use to establish a validation process for an assay is detailed in this document. Before validating a method, laboratories must optimise it and then document the protocol. All instruments must be calibrated and maintained throughout the testing process. The validation process involves a series of steps including: (i) testing of dilution series of positive samples to determine the limits of detection of the assay and their linearity over concentrations to be measured in quantitative NAT; (ii) establishing the day-to-day variation of the assay's performance; (iii) evaluating the sensitivity and specificity of the assay as far as practicable, along with the extent of cross-reactivity with other genomic material; and (iv) assuring the quality of assembled assays using quality control procedures that monitor the performance of reagent batches before introducing new lots of reagent for testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oomycete diseases cause significant losses across a broad range of crop and aquaculture commodities worldwide. These losses can be greatly reduced by disease management practices steered by accurate and early diagnoses of pathogen presence. Determinations of disease potential can help guide optimal crop rotation regimes, varietal selections, targeted control measures, harvest timings and crop post-harvest handling. Pathogen detection prior to infection can also reduce the incidence of disease epidemics. Classical methods for the isolation of oomycete pathogens are normally deployed only after disease symptom appearance. These processes are often-time consuming, relying on culturing the putative pathogen(s) and the availability of expert taxonomic skills for accurate identification; a situation that frequently results in either delayed application, or routine ‘blanket’ over-application of control measures. Increasing concerns about pesticides in the environment and the food chain, removal or restriction of their usage combined with rising costs have focussed interest in the development and improvement of disease management systems. To be effective, these require timely, accurate and preferably quantitatve diagnoses. A wide range of rapid diagnostic tools, from point of care immunodiagnostic kits to next generation nucleotide sequencing have potential application in oomycete disease management. Here we review currently-available as well as promising new technologies in the context of commercial agricultural production systems, considering the impacts of specific biotic and abiotic and other important factors such as speed and ease of access to information and cost effectiveness

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the efficacy and reproducibility of the cytologic diagnosis of salivary gland tumors (SGTs) using fine-needle aspiration cytology (FNAC). The study aimed to determine diagnostic accuracy, sensitivity, and specificity and to evaluate the extent of interobserver agreement. We retrospectively evaluated SGTs from the files of the Division of Pathology at the Clinics Hospital of São Paulo and Piracicaba Dental School between 2000 and 2006. We performed cytohistologic correlation in 182 SGTs. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 94%, 100%, 100%, 100%, and 99%, respectively. The interobserver cytologic reproducibility showed significant statistical concordance (P < .0001). FNAC is an effective tool for performing a reliable preoperative diagnosis in SGTs and shows high diagnostic accuracy and consistent interobserver reproducibility. Further FNAC studies analyzing large samples of malignant SGTs and reactive salivary lesions are needed to confirm their accuracy.