982 resultados para Rb fountain frequency standard


Relevância:

100.00% 100.00%

Publicador:

Resumo:

It is the first time in China that the phase variations and phase shift of microwave cavity in a miniature Rb fountain frequency standard are studied, considering the effect of imperfect metallic walls. Wall losses in the microwave cavity lead to small traveling wave components that deliver power from the cavity feed to the walls of cavity. The small traveling wave components produce a microradian distribution of phase throughout the cavity ity, and therefore distributed cavity phase shifts need to be considered. The microwave cavity is a TE011 circular cylinder copper cavity, with round cut-hole of end plates (14mm in diameter) for access for the atomic flux and two small apertures in the center of the side wall for coupling in microwave power. After attenuation alpha is calculated, field variations in cavity are solved. The field variations of the cavity are given. At the same time, the influences of loaded quality factor QL and diameter/height (2a/d) of the microwave cavity on the phase variations and phase shift are considered. According to the phase variation and phase shift of microwave cavity we select the parameters of cavity, diameter 2a = 69.2mm, height d = 34.6mm, QL = 5000, which will result in an uncertainty delta(Delta f / f0 ) < 4.7 x 10(-17) and meets the requirement for the miniature Rb fountain frequency standard with accuracy 10(-15).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A compact direct digital frequency synthesizer (DDFS) for system-on-chip implementation of the high precision rubidium atomic frequency standard is developed. For small chip size and low power consumption, the phase to sine mapping data is compressed using sine symmetry technique, sine-phase difference technique, quad line approximation technique,and quantization and error read only memory (QE-ROM) technique. The ROM size is reduced by 98% using these techniques. A compact DDFS chip with 32bit phase storage depth and a 10bit on-chip digital to analog converter has been successfully implemented using a standard 0.35μm CMOS process. The core area of the DDFS is 1.6mm^2. It consumes 167mW at 3.3V,and its spurious free dynamic range is 61dB.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have investigated the spectra of the electromagnetically induced transparency (EIT) when a cell is filled with a buffer gas. Our theoretical results show that the buffer gas can induce a narrower spectra line and steeper dispersion than those of the usual EIT case in a homogeneous and Doppler broadened system. The linewidth decreases with the increase of the buffer gas pressure. This narrow spectra may be applied to quantum information processing, nonlinear optics and atomic frequency standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

对自行研制的激光冷却铷原子喷泉钟的微波谐振腔进行了分析和设计,确定了需要的微波谐振腔基本参数。对影响微波谐振腔共振频率的因素进行了分析和研究,得到了共振频率随环境因素的变化规律。这些对调节微波腔共振频率和提高原子钟的准确度有重要意义。还对研制的微波谐振腔进行了测试,结果表明微波谐振腔的性能满足激光冷却铷原子喷泉钟的要求。由测试结果进一步估算了微波谐振腔引起的横向腔相移。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the absorptive spectral lines of four-level atomic system driven by a coupling, probe and microwave fields. Due to the perturbation of the microwave field, the original electromagnetically induced transparency is changed to electromagnetically induced absorption and the absorptive spectral line can be very narrow. This ultranarrow spectral line has potential applications to the microwave atomic frequency standard and the measurement of very weak magnetic field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

针对多普勒激光雷达激光源短期频率漂移低于1 MHz的要求,设计了一种共焦干涉仪作为频率标准进行稳频。通过对三种不同材料制成的共焦法布里-珀罗(Fabry-Perot)干涉仪中心频率随温度漂移情况进行分析对比,选用零膨胀微晶玻璃材料制作共焦法布里-珀罗干涉仪,腔镜和隔离器通过光胶的方式进行组合,并且置于温控精度优于0.01 K的双层密封温控箱中。经过实验测量,共焦法布里-珀罗干涉仪的自由光谱范围为370 MHz,透射谱半峰全宽(FWHM)为1.7 MHz,精细度为220。采用该共焦干涉仪进行稳频,理论稳频精度可达0.15 MHz,满足激光多普勒雷达单频激光源的稳频要求。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bird vocalisations are often essential for sex recognition, especially in species that show little morphological sex dimorphism. Brown skuas (Catharacta antarctica lonnbergi), which exhibit uniform plumage across both sexes, emit three main calls: the long call, the alarm call and the contact call. We tested the potential for sex recognition in brown skua calls of 42 genetically sexed individuals by analysing 8-12 acoustic parameters in the temporal and frequency domains of each call type. For every call type, we failed to find sex differences in any of the acoustic parameters measured. Stepwise discriminant function analysis (DFA) revealed that sexes cannot be unambiguously classified, with increasing uncertainty of correct classification from contact calls to long calls to alarm calls. Consequently, acoustic signalling is probably not the key mechanism for sex recognition in brown skuas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Observations of egg production rates (EPR) for female Calanus finmarchicus were compared from different regions of the North Atlantic. The regions were diverse in size and sampling frequency, ranging from a fixed time series station in the Lower St Lawrence Estuary, off Rimouski, where nearly 200 experiments were carried out between May and December from 1994 to 2006, to a large-scale survey in the Northern Norwegian Sea, where about 50 experiments were carried out between April and June from 2002 to 2004. For this analysis the stations were grouped mostly along geographic lines, with only limited attention being paid to oceanographic features. There is some overlap between regions, however, where stations were sometimes kept together when they were sampled on the same cruise. As well some stations other than off Rimouski were occupied more than once during different years and/or in different seasons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the industrial revolution, [CO2]atm has increased from 280 µatm to levels now exceeding 380 µatm and is expected to rise to 730-1,020 µatm by the end of this century. The consequent changes in the ocean's chemistry (e.g., lower pH and availability of the carbonate ions) are expected to pose particular problems for marine organisms, especially in the more vulnerable early life stages. The aim of this study was to investigate how the future predictions of ocean acidification may compromise the metabolism and swimming capabilities of the recently hatched larvae of the tropical dolphinfish (Coryphaena hippurus). Here, we show that the future environmental hypercapnia (delta pH 0.5; 0.16 % CO2, ~1,600 µatm) significantly (p < 0.05) reduced oxygen consumption rate up to 17 %. Moreover, the swimming duration and orientation frequency also decreased with increasing pCO2 (50 and 62.5 %, respectively). We argue that these hypercapnia-driven metabolic and locomotory challenges may potentially influence recruitment, dispersal success, and the population dynamics of this circumtropical oceanic top predator.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have developed a technique to measure the absolute frequencies of optical transitions by using an evacuated Rb-stabilized ring-cavity resonator as a transfer cavity. The absolute frequency of the Rb D-2 line (at 780 nm) used to stabilize the cavity is known and allows us to determine the absolute value of the unknown frequency. We study wavelength-dependent errors due to dispersion at the cavity mirrors by measuring the frequency of the same transition in the Cs D-2 line (at 852 nm) at three cavity lengths. The spread in the values shows that dispersion errors are below 30 kHz, corresponding to a relative precision of 10(-10). We give an explanation for reduced dispersion errors in the ring-cavity geometry by calculating errors due to the lateral shift and the phase shift at the mirrors, and show that they are roughly equal but occur with opposite signs. We have earlier shown that diffraction errors (due to Guoy phase) are negligible in the ring-cavity geometry compared to a linear cavity; the reduced dispersion error is another advantage. Our values are consistent with measurements of the same transition using the more expensive frequency-comb technique. Our simpler method is ideally suited for measuring hyperfine structure, fine structure, and isotope shifts, up to several hundreds of gigahertz.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The southern industrial rivers (Aire, Calder, Don and Trent) feeding the Humber estuary were routinely monitored for a range of chlorinated micro- organic contaminants at least once a week over a 1.5-year period. Environmental Quality Standards (EQSs) for inland waters were set under the European Economic Community for a limited number of problematic contaminants (18). The results of the monitoring program for seven classes of chlorinated pollutants on the EQS list are presented in this study. All compounds were detected frequently with the exception of hexachlorobutadiene (where only one detectable measurement out of 280 individual samples occurred). In general, the rivers fell into two classes with respect to their contamination patterns. The Aire and Calder carried higher concentrations of micro- pollutants than the Don and Trent, with the exception of hexachlorobenzene (HCB). For Σ hexachlorocyclohexane (HCH) isomers (α + γ) and for dieldrin, a number of samples (~ 5%) exceeded their EQS for both the Aire and Calder. Often, ΣHCH concentrations were just below the EQS level. Levels of p,p'- DDT on occasions approached the EQS for these two rivers, but only one sample (out of 140) exceeded the EQS. No compounds exceeded their EQS levels on the Don and Trent. Analysis of the ratio of γ HCH/αHCH indicated that the source of HCH for the Don and Trent catchments was primarily lindane (γHCH) and, to a lesser extent, technical HCH (mixture of HCH isomers, dominated by α HCH), while the source(s) for the Aire and Calder had a much higher contribution from technical HCH.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: To compare a customized imaging guide and a standard film holder for obtaining optimally projected intraoral radiographs of dental implants.Material and methods: Intraoral radiographs of four screw-type implants with different inclination placed in an upper or lower dental phantom model were recorded by 32 groups of examiners after a short instruction in the use of the RB-RB/LB-LB mnemonic rule. Half of the examiners recorded the images using a standard film holder and the other half used a customized imaging guide. Each radiograph was assessed under blinded conditions with regard to rendering of the implant threads and was assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable, and (4) hopeless.Results: For the upper jaw, the same number of exposures per implant were made to achieve an acceptable image (P = 0.86) by the standard film holder method (median = 2) and the imaging guide method (median = 2). For the lower jaw, medians for the imaging guide method and the film holder method were 1 and 2, respectively (P = 0.004). For the imaging guide method, the first exposure was rated as perfect/acceptable in 62% of the cases and for the film holder method in 41% of the cases (P = 0.013). After <= 2 exposures, 78% (imaging guide method) and 69% (film holder method) of the implant images were perfect/acceptable (P=0.23). The implant inclination did not have a major influence on the outcomes.Conclusion: Perfect or acceptable images were achieved after two exposures with the same frequency either using a customized imaging guide method or a standard film holder method. However, the use of a customized imaging guide method was overall significantly superior to a standard film holder method in terms of obtaining perfect or acceptable images with only one exposure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We aimed to investigate the naturally occurring horizontal plane movements of a head stabilized in a standard ophthalmic headrest and to analyze their magnitude, velocity, spectral characteristics, and correlation to the cardio pulmonary system. Two custom-made air-coupled highly accurate (±2 μm)ultrasound transducers were used to measure the displacements of the head in different horizontal directions with a sampling frequency of 100 Hz. Synchronously to the head movements, an electrocardiogram (ECG) signal was recorded. Three healthy subjects participated in the study. Frequency analysis of the recorded head movements and their velocities was carried out, and functions of coherence between the two displacements and the ECG signal were calculated. Frequency of respiration and the heartbeat were clearly visible in all recorded head movements. The amplitude of head displacements was typically in the range of ±100 μm. The first harmonic of the heartbeat (in the range of 2–3 Hz), rather than its principal frequency, was found to be the dominant frequency of both head movements and their velocities. Coherence analysis showed high interdependence between the considered signals for frequencies of up to 20 Hz. These findings may contribute to the design of better ophthalmic headrests and should help other studies in the decision making of whether to use a heavy headrest or a bite bar.