1000 resultados para Raman imaging


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rhodium phthalocyanine (RhPc) was synthesized and ultra thin Langmuir-Blodgett (LB) films of RhPc were successfully fabricated. The LB film characterization was carried out using both UV-vis absorption spectra and Raman scattering. The Raman spectroscopy was carried out using 633 and 780 nm laser lines. LB films were deposited onto Ag nanoparticles to achieve the surface-enhanced pre-resonance Raman scattering (pre-SERRS) and surface-enhanced Raman scattering (SERS) for both laser lines, respectively, which allowed the characterization of the RhPc ultra thin films. The morphology of the LB RhPc neat film is extracted from micro-Raman imaging. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Raman imaging spectroscopy is a highly useful analytical tool that provides spatial and spectral information on a sample. However, CCD detectors used in dispersive instruments present the drawback of being sensitive to cosmic rays, giving rise to spikes in Raman spectra. Spikes influence variance structures and must be removed prior to the use of multivariate techniques. A new algorithm for correction of spikes in Raman imaging was developed using an approach based on comparison of nearest neighbor pixels. The algorithm showed characteristics including simplicity, rapidity, selectivity and high quality in spike removal from hyperspectral images.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Raman imaging spectroscopy is a highly useful analytical tool that provides spatial and spectral information on a sample. However, CCD detectors used in dispersive instruments present the drawback of being sensitive to cosmic rays, giving rise to spikes in Raman spectra. Spikes influence variance structures and must be removed prior to the use of multivariate techniques. A new algorithm for correction of spikes in Raman imaging was developed using an approach based on comparison of nearest neighbor pixels. The algorithm showed characteristics including simplicity, rapidity, selectivity and high quality in spike removal from hyperspectral images.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Surface-enhanced resonance Raman scattering (SERRS) is used for single-molecule detection from spatially resolved 1-mum(2) sections of a Langmuir-Blodgett (LB) monolayer deposited onto a Ag film. The target molecule, his (benzimidazo) thioperylene (BZP), is dispersed in an arachidic acid monomolecular layer containing one BZP molecule per mum(2) which is also the probing area of the Raman microscope. For concentrated samples (attomole quantities in the field of view), average SERRS, surface-enhanced fluorescence (SEF), and Raman imaging, including line mapping and global images at different temperatures, were recorded. Single-molecule SERRS spectra, obtained using an LB monolayer, present changes in bandwidth and relative intensities, highlighting the properties of single-molecule SERRS that are lost in average SERRS measurements of mixed LB monolayers obtained at the same temperatures. Also, the dilute system phenomenon of blinking is discussed with regard to results obtained from LB monolayers. The dilution process used in the single-molecule LB SERRS work is independently supported by fluorescence results obtained from very dilute solutions with monomer concentrations down to 10(-12) M.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cette thèse caractérise les propriétés optiques des matériaux plasmoniques microstructurés et procède à l’évaluation des paramètres analytiques afin de les employer comme plateforme de biodétection en spectroscopie de résonance des plasmons de surface (SPR). Aux dimensions micrométriques, les matériaux plasmoniques présentent des caractéristiques optiques propres aux nano- et macromatériaux. La cartographie physicooptiques en SPR de matériaux méso- et microscopiques s’est effectuée à l’aide de films structurés de motifs périodiques triangulaires et circulaires fabriqués par une technique modifiée de lithographie par nanosphères (nanosphere lithography, NSL). À partir de cette vue d’ensemble, quelques films structurés ont été sélectionné en fonction d’aspects analytiques tels que la sensibilité et la résolution face aux variations d’indice de réfraction (RI) pour déterminer le potentiel de ces matériaux comme plateforme de biodetection. Les propriétés optiques distinctes des films microstructurés proviennent d’interactions résonantes entre les modes de plasmons de surface (SP) localisé et délocalisé identifiés par la relation de dispersion en SPR ainsi que l’imagerie Raman. Les conditions de résonance des modes SP dépendant de paramètres expérimentaux (λ, θ, η) tel qu’observés numériquement par rigorous coupled wave analysis (RCWA) et empiriquement. Ces travaux démontrent la nature plasmonique distincte des micro-matériaux et leur potentiel d’intégration aux techniques analytiques SPR existantes. Les matériaux plasmoniques micrométriques furent également étudiés pour l’implémentation de la SPR à une pointe de microscopie à force atomique (atomic force microscopy, AFM) combinant ainsi la spectroscopie à l’imagerie topographique. Des travaux préliminaires se sont concentrés sur la signature spectroscopique de leviers en silicium (Si) et en nitrure de silicium (Si3N4), l’impact d’un revêtement d’or sur les pointes et l’influence de milieu environnant. Une image d’origine plasmonique a été obtenue avec des leviers en Si3N4 revêtus d’or en transmission dans un environnement aqueux, indiquant ainsi le potentiel de ces pointes comme micro-biocapteur SPR. Ces résultats préliminaires servent de fondement pour orienter les prochaines investigations dans ce projet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to develop a methodology using Raman hyperspectral imaging and chemometric methods for identification of pre- and post-blast explosive residues on banknote surfaces. The explosives studied were of military, commercial and propellant uses. After the acquisition of the hyperspectral imaging, independent component analysis (ICA) was applied to extract the pure spectra and the distribution of the corresponding image constituents. The performance of the methodology was evaluated by the explained variance and the lack of fit of the models, by comparing the ICA recovered spectra with the reference spectra using correlation coefficients and by the presence of rotational ambiguity in the ICA solutions. The methodology was applied to forensic samples to solve an automated teller machine explosion case. Independent component analysis proved to be a suitable method of resolving curves, achieving equivalent performance with the multivariate curve resolution with alternating least squares (MCR-ALS) method. At low concentrations, MCR-ALS presents some limitations, as it did not provide the correct solution. The detection limit of the methodology presented in this study was 50μgcm(-2).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Connectivity of the glycocalyx covering of small communities of Acidithiobacillus ferrooxidans bacteria deposited on hydrophilic mica plates was imaged by atomic force microscopy. When part of the coverage was removed by water rinsing, an insoluble structure formed by corrals surrounding each individual bacterium was observed. A collective ring structure with clustered bacteria (>= 3) was observed, which indicates that the bacteria perceived the neighborhood in order to grow a protective structure that results in smaller production of exopolysaccharides material. The most surprising aspect of these collective corral structures was that they occur at a low bacterial cell density. The deposited layers were also analyzed by confocal Raman microscopy and shown to contain polysaccharides, protein, and glucoronic acid.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

H-1- and C-13-NMR spectroscopy and FT-Raman spectroscopy are used to investigate the properties of a polymer gel dosimeter post-irradiation. The polymer gel (PACT) is composed of acrylamide, N,N'-methylene-bisacrylamide, gelatin, and water. The formation of a polyacrylamide network within the gelatin matrix follows a dose dependence nonlinearly correlated to the disappearance of the double bonds from the dissolved monomers within the absorbed dose range of 0-50 Gy. The signal from the gelatin remains constant with irradiation. We show that the NMR spin-spin relaxation times (T-2) of PAGs irradiated to up to 50 Gy measured in a NMR spectrometer and a clinical magnetic resonance imaging scanner can be modeled using the spectroscopic intensity of the growing polymer network. More specifically, we show that the nonlinear T-2 dependence against dose can be understood in terms of the fraction of protons in three different proton pools. (C) 2000 John Wiley & Sons, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acryl ate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo read-out with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study presents the results of Raman spectroscopy applied to the classification of arterial tissue based on a simplified model using basal morphological and biochemical information extracted from the Raman spectra of arteries. The Raman spectrograph uses an 830-nm diode laser, imaging spectrograph, and a CCD camera. A total of 111 Raman spectra from arterial fragments were used to develop the model, and those spectra were compared to the spectra of collagen, fat cells, smooth muscle cells, calcification, and cholesterol in a linear fit model. Non-atherosclerotic (NA), fatty and fibrous-fatty atherosclerotic plaques (A) and calcified (C) arteries exhibited different spectral signatures related to different morphological structures presented in each tissue type. Discriminant analysis based on Mahalanobis distance was employed to classify the tissue type with respect to the relative intensity of each compound. This model was subsequently tested prospectively in a set of 55 spectra. The simplified diagnostic model showed that cholesterol, collagen, and adipocytes were the tissue constituents that gave the best classification capability and that those changes were correlated to histopathology. The simplified model, using spectra obtained from a few tissue morphological and biochemical constituents, showed feasibility by using a small amount of variables, easily extracted from gross samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La concentration locale des messagers chimiques sécrétés par les cellules peut être mesurée afin de mieux comprendre les mécanismes moléculaires liés à diverses maladies, dont les métastases du cancer. De nouvelles techniques analytiques sont requises pour effectuer ces mesures locales de marqueurs biologiques à proximité des cellules. Ce mémoire présentera le développement d’une nouvelle technique basée sur la réponse plasmonique sur des leviers AFM, permettant d’étudier les réactions chimiques et biologiques à la surface des leviers grâce au phénomène de résonance des plasmons de surface (SPR), ainsi qu’à la diffusion Raman exaltée par effet de pointe (TERS). En effet, il est possible de localiser l’amplification du signal Raman à la pointe d’un levier AFM, tout comme le principe de la diffusion Raman exaltée par effet de surface (SERS) basée sur la diffusion de la lumière par des nanoparticules métalliques, et permettant une large amplification du signal Raman. La surface du levier est recouverte d’une nano-couche métallique d’or, suivi par des réactions biologiques pour l’immobilisation d’un récepteur moléculaire, créant ainsi un biocapteur sur la pointe du levier. Une détection secondaire utilisant des nanoparticules d’or conjuguées à un anticorps secondaire permet également une amplification du signal SPR et Raman lors de la détection d’antigène. Ce mémoire démontrera le développement et la validation de la détection de l’immunoglobuline G (IgG) sur la pointe du levier AFM.Dans des projets futurs, cette nouvelle technique d’instrumentation et d’imagerie sera optimisée grâce à la création d’un micro-détecteur protéique généralement adapté pour l’étude de la communication cellulaire. En intégrant le signal SPR à la microscopie AFM, il sera alors possible de développer des biocapteurs SPR couplés à une sonde à balayage, ce qui permettra d’effectuer une analyse topographique et de l’environnement chimique d’échantillons cellulaires en temps réel, pour la mesure des messagers moléculaires sécrétés dans la matrice extracellulaire, lors de la communication cellulaire.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The presence of anatase and rutile domains on nanocrystalline films of P25 TiO(2), as well as the distinct coordination modes of carboxylates on those phases, were revealed by confocal Raman microscopy, a technique that showed to be suitable for imaging the chemical morphology down to submicrometric size.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The add protection effect promoted by traces of PdCl2 in [Ni(dmgH)(2)] spot tests was elucidated from confocal Raman microscopy imaging, which revealed the formation of protecting layers of [Pd(dmgH)(2)] closing the extremities of the [Ni(dmgH)(2)] filaments.