999 resultados para Radiographic caries diagnosis
Resumo:
The aim of this in vitro study was to assess the influence of varying examiner's clinical experience on the reproducibility and accuracy of radiographic examination for occlusal caries detection. Standardized bitewing radiographs were obtained from 166 permanent molars. Radiographic examination was performed by final-year dental students from two universities (A, n=5; B, n=5) and by dentists with 5 to 7 years of experience who work in two different countries (C, n=5; D, n=5). All examinations were repeated after 1-week interval. The teeth were histologically prepared and assessed for caries extension. For intraexaminer reproducibility, the unweighted kappa values were: A (0.11-0.40), B (0.12-0.33), C (0.47-0.58), and D (0.42-0.71). Interexaminer reproducibility statistics were computed based on means +/- SD of unweighted kappa values: A (0.07 +/- 0.05), B (0.12 +/- 0.09), C (0.24 +/- 0.08), and D (0.33 +/- 0.10). Sensitivity, specificity, and accuracy were calculated at D(1) and D(3) thresholds and compared by performing McNemar test (p=0.05). D(1) sensitivity ranged between 0.29 and 0.75 and specificity between 0.24 and 0.85. D(3) specificity was moderate to high (between 0.62 and 0.95) for all groups, with statistically significant difference between the dentists groups (C and D). Sensitivity was low to moderate (between 0.21 and 0.57) with statistically significant difference for groups B and D. Accuracy was similar for all groups (0.55). Spearman's correlations were: A (0.12), B (0.24), C (0.30), and D (0.38). In conclusion, the reproducibility of radiographic examination was influenced by the examiner's clinical experience, training, and dental education as well as the accuracy in detecting occlusal caries.
Resumo:
Objective: The aim of this study was to evaluate the performances of observers in diagnosing proximal caries in digital images obtained from digital bitewing radiographs using two scanners and four digital cameras in Joint Photographic Experts Group (JPEG) and tagged image file format (TIFF) files, and comparing them with the original conventional radiographs. Method: In total, 56 extracted teeth were radiographed with Kodak Insight film (Eastman Kodak, Rochester, NY) in a Kaycor Yoshida X-ray device (Kaycor X-707;Yoshida Dental Manufacturing Co., Tokyo, Japan) operating at 70 kV and 7 mA with an exposure time of 0.40 s. The radiographs were obtained and scanned by CanonScan D646U (Canon USA Inc., Newport News, VA) and Genius ColorPage HR7X (KYE Systems Corp. America, Doral, FL) scanners, and by Canon Powershot G2 (Canon USA Inc.), Canon RebelXT (Canon USA Inc.), Nikon Coolpix 8700 (Nikon Inc., Melville, NY), and Nikon D70s (Nikon Inc.) digital cameras in JPEG and TIFF formats. Three observers evaluated the images. The teeth were then observed under the microscope in polarized light for the verification of the presence and depth of the carious lesions. Results: The probability of no diagnosis ranged from 1.34% (Insight film) to 52.83% (CanonScan/JPEG). The sensitivity ranged from 0.24 (Canon RebelXT/JPEG) to 0.53 (Insight film), the specificity ranged from 0.93 (Nikon Coolpix/JPEG, Canon Powershot/TIFF, Canon RebelXT/JPEG and TIFF) to 0.97 (CanonScan/TIFF and JPEG) and the accuracy ranged from 0.82 (Canon RebelXT/JPEG) to 0.91 (CanonScan/JPEG). Conclusion: The carious lesion diagnosis did not change in either of the file formats (JPEG and TIFF) in which the images were saved for any of the equipment used. Only the CanonScan scanner did not have adequate performance in radiography digitalization for caries diagnosis and it is not recommended for this purpose. Dentomaxillofacial Radiology (2011) 40, 338-343. doi: 10.1259/dmfr/67185962
Resumo:
Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872
Resumo:
OBJECTIVES: To determine the clinical performance of a laser fluorescence device (DIAGNOdent pen, KaVo) to discriminate between different occlusal caries depths (D(0)-D(1-4); D(0-2)-D(3,4)) in permanent molars. METHODS: In this prospective, randomized two-centre-study 120 sound/uncavitated carious sites in 120 patients were measured after visual and radiographic caries assessment. In cases of operative intervention (n=86), the lesion depths after caries removal were recorded (reference). In cases of preventive intervention (n=34), the sites were reassessed visually/radiographically after 12 months to verify the status assessed before (reference). The discrimination performance was determined statistically (Mann-Whitney test, Spearman's rho coefficient, and areas under the receiver operating characteristic curves (AUCs)). Sensitivities (SE) and specificities (SP) were plotted as a function of the measured values and cut-off values for the mentioned thresholds suggested. RESULTS: Sound sites (n=13) had significantly minor fluorescence values than carious sites (n=107) (P<0.0001) as had sites with no/enamel caries (n=63) compared to dentinal caries (n=57). The AUCs for the same discriminations were 0.92 and 0.78 (P<0.001). For the D(0)-D(1-4) threshold, a cut-off at a value of 12 (SE: 0.88, SP: 0.85) and for the D(0-2)-D(3,4) threshold at 25 (SE: 0.67, SP: 0.79) can be suggested. A moderate positive correlation between the measurements and the caries depths was calculated (rho=+0.57, P=0.01). CONCLUSION: Within this study, the device's discrimination performance for different caries depths was moderate to very good and it may be recommended as adjunct tool in the diagnosis of occlusal caries.
Resumo:
The objective of this study was to evaluate the effectiveness of a therapeutic sealant to arrest non-cavitated proximal carious lesion progression. The study population comprised 44 adolescents who had bitewing radiographs taken for caries diagnosis. Non-cavitated lesions extending up to half of dentin thickness were included in the sample. In the experimental group (n = 33), the proximal caries-lesion surfaces were sealed with an adhesive (OptiBond Solo, Kerr) after tooth separation. The control group (n = 11) received no treatment, except for oral hygiene instructions including use of dental floss. Follow-up radiographs were taken after one year and were analyzed in comparison with baseline radiographs. In a blind study setting, visual readings were performed by two examiners, blinded to whether the examined radiograph was baseline or follow-up, and whether it concerned a test or control lesion. The efficacy of sealing treatment was evaluated by the McNemar test (0.05). About 22% of the sealed lesions showed reduction, 61% showed no change and 16% showed progression. For the control lesions, the corresponding values were 27%, 36% and 36% respectively. The number of lesions that showed reduction and no changes were merged and therefore 83.3% of the sealed lesions and 63.6% of the control lesions were considered clinically successful. No statistical significance was detected (p > 0.05). In the course of 1 year, sealing proximal caries lesions was not shown to be superior to lesion monitoring.
Resumo:
The objective is to differentiate noncavitated caries enamel through time-resolved fluorescence and to find excitation and emission parameters that can be applied in future clinical practice for detection of caries lesions that are not clearly visible to the professional. Sixteen human teeth with noncavitiated white-spot caries were selected for this work. Fluorescence intensity decay was measured by using an apparatus based on the time-correlated single-photon counting method. An optical fiber bundle was employed for sample excitation (440 nm), and the fluorescence collected by the same bundle (500 nm) was registered. The average lifetime for sound enamel was 7: 93 +/- 0: 09, 2: 46 +/- 0: 04, and 0: 51 +/- 0: 02 ns, whereas for the carious enamel the lifetimes were 4: 84 +/- 0: 06, 1: 35 +/- 0: 02, and 0: 16 +/- 0: 01 ns. It was concluded that it is possible to differentiate between carious and sound regions by time-resolved fluorescence and that, although the origin of enamel fluorescence is still uncertain, the lifetime values seem to be typical of fluorophores like collagen I. (C) 2010 Optical Society of America
Resumo:
The aim of this study was to determine the effectiveness and reliability of laser fluorescence measurements in relation to occlusal caries diagnosis. DIAGNOdent 2095 (Kavo, Biberach, Germany), which has been developed especially for caries diagnosis, was utilized. Five (5) teeth were examined in the pilot test; after that, ten (10) teeth were examined in order to calibrate both examiners. Data were obtained from 66 teeth (36 molars and 30 premolars), totalizing 144 sites identified through photographs of the occlusal surfaces. Reproducibility was evaluated in 10 teeth. The interexaminer Spearman correlation (r) was 0.89 and the intra-examiner, 0.93 and 0.97 (examiner A and B, respectively). Validation was carried out by histological examination (stereomicroscope). For the two examiners the sensitivity of the device was relatively high, varying from 0.81 to 1.00, while specificity varied according to which validation criterion was used (0.77 - 0.86: enamel lesion / 0.52 - 0.59: dentin lesion). It was concluded that DIAGNodent presented good capacity of identifying any alteration of the dental surface, nevertheless it presents the disadvantage of accomplishing many false-positive diagnosis when the validation criterion is dentin lesion.
Resumo:
The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device. Copyright (C) 2008 S. Karger AG, Basel.
Resumo:
The aim of the study was to determine the reproducibility and validity of DIAGNOdent in detecting active and arrested caries lesions on free smooth surfaces. Volunteers were selected from state schools of Piracicaba, São Paulo, Brazil. Overall, 220 lesions were clinically examined. Two specially trained ('calibrated') examiners performed both clinical and laser evaluations independently, and after a 1-week interval, the examinations were repeated, the intra-examiner agreement for the laser evaluation was substantial (kappa(ex1) = 0.79, kappa(ex2) = 0.71). There was almost perfect agreement between the two examiners for the clinical examination (kappa(ex1) = 0.95, kappa(ex2) = 0.85). The inter-examiner agreement showed substantial reproducibility (kappa = 0.77) for the laser examination and almost perfect agreement (kappa = 0.85) for the clinical evaluation. The validation criterion was the clinical examination of white spots, recorded as active or arrested. The sensitivity was 0.72 and the specificity was 0.73, which indicates that the DIAGNOdent was a good auxiliary method for detecting incipient caries lesions on free smooth surfaces. The utilization of both methods can improve the efficacy of caries diagnosis. Copyright (C) 2002 S. Karger AG, Basel.
Resumo:
Objectives: The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. Methods: 257 non-filled approximal surfaces from human permanent premolars and molars were recorded by two intraoral digital receptors, a storage phosphor plate (Digora Optime, Soredex) and a solid-state CMOS sensor (Digora Toto, Soredex), and scanned in a cone beam CT unit (3D Accuitomo FPD80, Morita) with a FOV of 4 cm and a voxel size of 0.08 mm. Image sections were carried out in the axial and mesiodistal tooth planes. Six observers recorded surface cavitation in all images. Validation of the true absence or presence of surface cavitation was performed by inspecting the surfaces under strong light with the naked eye. Differences in sensitivity, specificity and agreement were estimated by analysing the binary data in a generalized linear model using an identity link function. Results: A significantly higher sensitivity was obtained by all observers with CBCT (p,0.001), which was not compromised by a lower specificity. Therefore, a significantly higher overall agreement was obtained with CBCT (p,0.001). There were no significant differences between the Digora Optime phosphor plate system and the Digora Toto CMOS sensor for any parameter. Conclusions: CBCT was much more accurate in the detection of surface cavitation in approximal surfaces than intraoral receptors. The differences are interpreted as clinically significant. A CBCT examination performed for other reasons should also be assessed for approximal surface cavities in teeth without restorations. © 2013 The British Institute of Radiology.
Resumo:
Objetivo: Revisar os casos de enfisema lobar congênito (ELC) operados nos últimos 30 anos em dois hospitais universitários. Métodos: Foram revistos os prontuários médicos das crianças com ELC operadas no Hospital das Clínicas da Faculdade de Medicina de Botucatu e no Hospital da Universidade de Mogi das Cruzes entre 1979 e 2009. Dados sobre sintomas, exame físico, achados radiológicos, diagnóstico, tratamento cirúrgico e seguimento pós-operatório mediato e tardio foram analisados. Resultados: Durante o período estudado, 20 crianças com ELC foram submetidas a tratamento cirúrgico. A média de idade dos pacientes no momento da cirurgia foi 6,9 meses (variação, 9 dias a 4 anos). Todos os casos apresentaram sintomas ao nascimento ou nos primeiros meses de vida. Em todos os casos, a radiografia simples de tórax foi importante na definição do diagnóstico. Em casos de dificuldade respiratória moderada, a TC de tórax auxiliou no diagnóstico. Um paciente com desconforto respiratório grave foi diagnosticado erroneamente com pneumotórax hipertensivo e submetido a drenagem torácica. A broncoscopia só foi realizada nos pacientes com dificuldade respiratória moderada e não foram encontrados sinais de anomalias traqueobrônquicas. A abordagem cirúrgica foi realizada através de toracotomia lateral poupadora de músculo. O lobo superior esquerdo e o lobo médio foram os mais afetados, seguidos pelo lobo superior direito. A lobectomia foi realizada em 18 casos, enquanto a bilobectomia foi realizada em 2 casos (com ressecção de cisto broncogênico em 1 desses). Complicações pós-operatórias não foram observadas. O acompanhamento pós-operatório foi de pelo menos 24 meses (média, 60 meses) e não foram observadas complicações tardias nesta série. Conclusões: O ELC é uma doença pouco comum, ainda negligenciada, de etiologia incerta, mas de fácil diagnóstico radiológico e tratamento cirúrgico eficaz.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência Odontólogica - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)