959 resultados para RETINAL THICKNESS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conventional time-domain optical coherence tomography (OCT) has become an important tool for following dry or exudative age-related macular degeneration (AMD). Fourier-domain three-dimensional (3D) OCT was recently introduced. This study tested the reproducibility of 3D-OCT retinal thickness measurements in patients with dry and exudative AMD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Visual symptoms are common in Parkinson's disease with studies consistently demonstrating reductions in visual acuity, contrast sensitivity, colour and motion perception as well as alterations in electroretinogram latencies and amplitudes. Optical coherence tomography can examine retinal structure non-invasively and retinal thinning has been suggested as a potential biomarker for neurodegeneration in Parkinson's disease. Our aim was to examine the retinal thickness of a cohort of Parkinson's disease subjects (and age-matched controls) to establish the practical utility of optical coherence tomography in a representative older Parkinson's disease group. METHODS: Fifty-one established Parkinson's disease subjects and 25 healthy controls were subjected to ophthalmological assessment and optical coherence tomography (Zeiss Stratus 3000™) of macular thickness and volume and retinal nerve fibre thickness around the optic nerve head. Twenty four percent of control and 20% of Parkinson's disease subjects were excluded from final analysis due to co-morbid ocular pathology. Further data was excluded either due to poor tolerability of optical coherence tomography or poor quality scans. RESULTS: Despite a reduction in both visual acuity and contrast sensitivity in the residual evaluable Parkinson's disease cohort, we did not detect any differences between the two study groups for any measures of retinal thickness, in contrast to previously published work. CONCLUSIONS: In addition to technical problems inherent in the evaluation, the lack of difference between Parkinson's disease and healthy control subjects suggests longitudinal studies, employing newer techniques, will be required to define the role of optical coherence tomography as a potential diagnostic biomarker.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To test the reproducibility of retinal thickness measurements in healthy volunteers of a new Frequency-domain optical coherence tomography (OCT) device (Spectralis OCT; Heidelberg Engineering, Heidelberg, Germany). DESIGN: Prospective, observational study. METHODS: Forty-one eyes of 41 healthy subjects were included into the study. Intraobserver reproducibility was tested with 20 x 15 degree raster scans consisting of 37 high-resolution line scans that were repeated three times by one examiner (M.N.M.). Mean retinal thickness was calculated for nine areas corresponding to the Early Treatment Diabetic Retinopathy Study (ETDRS) areas. Coefficients of variation (COV) were calculated. RESULTS: Retinal thickness measurements were highly reproducible for all ETDRS areas. Mean total retinal thickness was 342 +/- 15 microm. Mean foveal thickness was 286 +/- 17 microm. COVs ranged from 0.38% to 0.86%. Lowest COV was found for the temporal outer ETDRS area (area 7; COV, 0.38%). Highest COV was found for the temporal inner ETDRS area (area 3; COV, 0.86%). Mean difference between measurement 1 and 2, measurement 1 and 3, and measurement 2 and 3 for all ETDRS areas was 1.01 microm, 0.98 microm, and 0.99 microm, respectively. CONCLUSION: Spectralis OCT retinal thickness measurements in healthy volunteers showed excellent intraobserver reproducibility with virtually identical results between retinal thickness measurements performed by one operator.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Poster Introduction: In neovascular age-related macular degeneration (nAMD), optical coherence tomography (OCT) is an important tool to determine when intravitreal injections of ranibizumab should be administered. Current guidelines recommend that patients should be reviewed four weekly and OCT indications for further treatment include subretinal fluid and intraretinal fluid or cysts. Purpose: We have reviewed the OCT scans of subjects who have successfully responded to ranibizumab to look for factors that might predict which patients will not require injection and could have extended appointments. Method: This was a prospective study in which we observed for 6 consecutive months the OCT images of 28 subjects who had received intravitreal ranibizumab for nAMD and were judged to be clinically inactive at recruitment to the study. Ratios between full retinal thickness (FRT = neurosensory retina + outer reflective band) and outer reflective band (ORB) thickness at the fovea were calculated for each subject at the moment of entering the study and at each successive visit for 6 consecutive months. Results: Patients with lower FRT/ORB ratios were found to be less likely to require an additional injection of ranibizumab and no subject with a ratio of 1.75 or less needed further injections. Conclusion: This small pilot study suggests that on macular OCT, the FRT/ORB ratio, and in particular values of 1.75 or less, may prove to be a useful, practical tool when deciding the follow up period for subjects undergoing treatment with intravitreal ranibizumab for nAMD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Poster section Design. Retrospective study. Purpose. To assess whether there are changes in foveal thickness (FT) and total macular volume (TMV) in pregnancy in diabetic subjects. Methods. The audit consisted of pregnant women with diabetes, with no maculopathy, who completed their antenatal care at Birmingham Heartlands Hospital. The Zeiss Stratus Optical coherence tomography (OCT) was performed on patients attending diabetic retinopathy (DR) screening at intervals throughout their pregnancy. To be included in the audit patients had to have at least one OCT scan during their pregnancy. Results. Altogether there were 8 type 1 and 22 type 2 patients with mean diabetes duration of 6 years (range 1-20). Mean gestation at DR screening with OCT during the first trimester was 9.7 weeks (6-13) (n=22). The mean and standard deviation for FT for the right was 179.1 µm ± 21.49 and for the left eye was 187.3 µm ± 23.55. The mean TMV was right 6.43 µm ± 0.35 and left 6.50 µm ± 0.39. The mean gestation at DR screening with OCT during the second trimester was 23.4 weeks (18-26) (n=25). The mean FT for the right was 191.4 µm ± 22.70 and the left 195.6 µm ± 24.77. The mean TMV was right 6.74 µm ± 0.45 and left 6.91 µm ± 0.35. The gestation of DR screening with OCT during the third trimester was 31.1 weeks (27-36) (n=15). The mean FT for the right was 181.5 µm ± 24.84 and for the left 193.1 µm ± 28.55. The mean TMV was right 6.80 µm ± 0.40 and left 6.84 µm ± 0.31. There were no significant differences in FT over the 3 trimesters. The TMV showed a significant difference when comparing the first and second trimesters (p<0.05). However, there was no significant statistical difference in TMV in the second and third trimesters. None of the patients showed any macula edema on the OCT. Conclusions. The results suggest there is no significant change in foveal thickness in pregnancy in diabetic subjects. There was a significant statistical difference in total macular volume in the second trimester; however, this would not be clinically significant. This is an important observation proven by the OCT which has not been previously studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate whether eyes with diabetic macular edema (DME) and central retinal thickness (CRT) >400 μm had better visual and anatomical outcomes compared to eyes with a CRT <400 μm when treated with intravitreal bevacizumab in a real-world setting. Patients and methods: Patients undergoing intravitreal bevacizumab therapy for DME were identified from the departmental database of a tertiary referral unit. Following the initial injection, a retreatment was performed for any persistent macular edema, unless there had been no previous response to repeated doses. Recorded parameters included visual acuity, CRT on optical coherence tomography (spectral domain optical coherence tomography [SD-OCT]), and SD-OCT characteristics. Comparisons were made between data at baseline and 12 months after the first injection, and differences were tested for statistical significance using the Student's t-test. Results: In all, 175 eyes of 142 patients were analyzed. Patients in group 2 (CRT >400 μm) had significantly more injections than group 1 (CRT <400 μm) (4.0 versus 3.3; P=0.003). Both groups had similar numbers of eyes with preexisting epiretinal membrane and/or vitreomacular traction at baseline. The reduction in CRT was significantly greater in group 2 when compared to group 1 (P<0.0001). In terms of visual gain between baseline and month 12, each gained significantly by a mean of 0.12 logarithm of the minimum angle of resolution units (P=0.0001), but there was no difference between groups 1 and 2 (P=0.99). Conclusion: These results do not support a 400 μm baseline CRT cut-off for treating DME with bevacizumab, in contrast to published data on ranibizumab. Our results also indicate that patients with a thicker CRT require more bevacizumab injections, making treatment less cost-effective for these patients. Our results could be used by practitioners to support the use of bevacizumab in DME without applying a CRT cut-off. © 2014 Mushtaq et al.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: To describe the evolution of retinal thickness in eyes affected with acute anterior uveitis (AAU) in the course of follow-up and to assess its correlation with severity of inflammatory activity in the anterior chamber. Methods: Design: Prospective, cohort study Setting: Institutional study Patient population: 72 eyes (affected and fellow eyes) of 36 patients Observation procedure: Patients were followed daily until beginning of resolution of inflammatory activity and weekly thereafter. Optical coherence tomography and laser flare photometry were performed at each visit. Treatment consisted of topical corticosteroids Main outcome measures: Retinal thickness of affected eyes, difference in retinal thickness between affected and fellow eyes and their evolution in time, association between maximal retinal thickness and initial laser flare photometry. Results: Difference in retinal thickness between affected and fellow eyes became significant on average seven days from baseline and remained so through-out follow-up (p<0.001). There was a steep increase in retinal thickness of affected eyes followed by a progressive decrease after reaching a peak value. Maximal difference in retinal thickness between affected and fellow eyes was observed between 17 and 25 days from baseline and exhibited a strong, positive correlation with initial laser flare photometry values (p=0.015). Conclusions: Retinal thickness in eyes affected with AAU presents a steep increase over 3 to 4 weeks and then gradually decreases. Severity of inflammation at baseline predicts the amount of retinal thickening in affected eyes. A characteristic pattern of temporal response of retinal anatomy to inflammatory stimuli seems to arise.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: To study the influence of retinal structural changes on oxygen saturation in retinitis pigmentosa (RP) patients. METHODS: Oximetry measurements were performed on 21 eyes of 11 RP patients and compared to 24 eyes of 12 controls. Retinal oxygen saturation was measured in all major retinal arterioles (A-SO₂) and venules (V-SO₂) with an oximetry unit of the retinal vessel analyser (IMEDOS Systems UG, Jena, Germany). Oximetry data were compared with morphological changes measured by Cirrus optical coherence tomography (OCT) (Carl Zeiss Meditec, Dublin, CA, USA, macular thickness protocol). RESULTS: In RP patients, the retinal A-SO₂ and V-SO₂ levels were higher at 99.3% (p = 0.001, anova based on mixed-effects model) and 66.8% (p < 0.001), respectively, and the difference between the two (A-V SO₂) was lower at 32.5% (p < 0.001), when compared to the control group (92.4%; 54.0%; 38.4%, respectively). With the RP group, the A-V SO₂ correlated positively, not only with central macular thickness, but also with retinal thickness, in zones 2 and 3 (p = 0.006, p = 0.007, p = 0.014). CONCLUSION: These data indicate that oxygen metabolism was altered in RP patients. Based on our preliminary results, retinal vessel saturation correlated with structural alterations in RP. This method could be valuable in monitoring disease progression and evaluating a potential therapeutic response.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Connexin (Cx) channels and hemichannels are involved in essential processes during nervous system development such as apoptosis, propagation of spontaneous activity and interkinetic nuclear movement. In the first part of this study, we extensively characterized Cx gene and protein expression during retinal histogenesis. We observed distinct spatio-temporal patterns among Studied Cx and an overriding, ubiquitous presence of Cx45 in progenitor cells. The role of Cx-mediated communication was assessed by using broad-spectrum (carbenoxotone, CBX) and Cx36/Cx50 channel-specific (quinine) blockers. In vivo application of CBX, but not quinine, caused remarkable reduction in retinal thickness, suggesting changes in cell proliferation/apoptosis ratio. Indeed, we observed a decreased number of mitotic cells in CBX-injected retinas, with no significant changes in the expression of PCNA, a marker for cells in proliferative state. Taken together, Our results pointed a pivotal role of Cx45 in the developing retina. Moreover, this study revealed that Cx-mediated Communication is essential in retinal histogenesis, particularly in the control of cell proliferation. (C) 2009 ISDN. Published by Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To compare central retinal thickness (CRT) measurements in healthy eyes by different commercially available OCT instruments and to compare the intersession reproducibility of such measurements.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Retinal vein occlusion is a leading cause of visual impairment. Experimental models of this condition based on laser photocoagulation of retinal veins have been described and extensively exploited in mammals and larger rodents such as the rat. However, few reports exist on the use of this paradigm in the mouse. The objective of this study was to investigate a model of branch and central retinal vein occlusion in the mouse and characterize in vivo longitudinal retinal morphology alterations using spectral domain optical coherence tomography. Retinal veins were experimentally occluded using laser photocoagulation after intravenous application of Rose Bengal, a photo-activator dye enhancing thrombus formation. Depending on the number of veins occluded, variable amounts of capillary dropout were seen on fluorescein angiography. Vascular endothelial growth factor levels were markedly elevated early and peaked at day one. Retinal thickness measurements with spectral domain optical coherence tomography showed significant swelling (p<0.001) compared to baseline, followed by gradual thinning plateauing two weeks after the experimental intervention (p<0.001). Histological findings at day seven correlated with spectral domain optical coherence tomography imaging. The inner layers were predominantly affected by degeneration with the outer nuclear layer and the photoreceptor outer segments largely preserved. The application of this retinal vein occlusion model in the mouse carries several advantages over its use in other larger species, such as access to a vast range of genetically modified animals. Retinal changes after experimental retinal vein occlusion in this mouse model can be non-invasively quantified by spectral domain optical coherence tomography, and may be used to monitor effects of potential therapeutic interventions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE Quantification of retinal layers using automated segmentation of optical coherence tomography (OCT) images allows for longitudinal studies of retinal and neurological disorders in mice. The purpose of this study was to compare the performance of automated retinal layer segmentation algorithms with data from manual segmentation in mice using the Spectralis OCT. METHODS Spectral domain OCT images from 55 mice from three different mouse strains were analyzed in total. The OCT scans from 22 C57Bl/6, 22 BALBc, and 11 C3A.Cg-Pde6b(+)Prph2(Rd2) /J mice were automatically segmented using three commercially available automated retinal segmentation algorithms and compared to manual segmentation. RESULTS Fully automated segmentation performed well in mice and showed coefficients of variation (CV) of below 5% for the total retinal volume. However, all three automated segmentation algorithms yielded much thicker total retinal thickness values compared to manual segmentation data (P < 0.0001) due to segmentation errors in the basement membrane. CONCLUSIONS Whereas the automated retinal segmentation algorithms performed well for the inner layers, the retinal pigmentation epithelium (RPE) was delineated within the sclera, leading to consistently thicker measurements of the photoreceptor layer and the total retina. TRANSLATIONAL RELEVANCE The introduction of spectral domain OCT allows for accurate imaging of the mouse retina. Exact quantification of retinal layer thicknesses in mice is important to study layers of interest under various pathological conditions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE To assess the effect of a bimonthly treatment regimen with intravitreal aflibercept on retinal fluid and pigment epithelial detachment (PED) in patients with neovascular age-related macular degeneration (AMD). METHODS Twenty-six treatment-naive eyes of 26 patients with choroidal neovascularisation secondary to AMD were included. The patients received three initial monthly (mean 30 days) intravitreal injections of aflibercept followed by a bimonthly (mean 62 days) fixed regimen for a total of 1 year. Best-corrected visual acuity (BCVA) and optical coherence tomography (OCT) measurements were recorded at monthly intervals. In addition, the presence of intraretinal fluid (IRF) or subretinal fluid (SRF) or a combination of both as well as serous and fibrovascular PEDs were assessed. RESULTS The mean patient age was 80 years (range 54-93). There were 14 male and 12 female patients. The mean gain in BCVA at 1 year was 9.3 letters (SEM ±3) with a mean reduction of the central retinal thickness of 154 µm (SEM ±50). After 3 monthly injections of aflibercept, there was resolution of IRF and SRF in 80% of the treated eyes; the amount of fluid increased at months 4, 6 and 8 with troughs in between. Whereas fibrovascular PEDs remained stable after the loading phase, serous PEDs displayed a seesaw pattern. Patients without retinal pigment epithelium (RPE) atrophy at the end of the 1-year period had significantly better BCVA compared to patients with RPE atrophy (p = 0.03). CONCLUSION Despite significant overall BCVA gain, bimonthly intervals seem insufficient to maintain the morphological improvements after the initial loading dose with intravitreal aflibercept.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE To identify individual retinal layer thickness changes associated with visual acuity gain in diabetic macular edema treated with ranibizumab using layer segmentation on high-resolution optical coherence tomography scans. METHODS Retrospective observational case series. Thirty-three treatment-naive eyes with diabetic macular edema were imaged by spectral domain optical coherence tomography at monthly visits while receiving intravitreal ranibizumab treatment as needed, guided by visual acuity. Thickness changes of individual layers after 1 year were quantitatively analyzed and correlated with visual acuity gain. RESULTS The mean best-corrected visual acuity improvement at 1 year was 6.2 (SEM ± 1.5) Early Treatment Diabetic Retinopathy Study letters, and central retinal thickness decreased by 66 ± 18 μm. In the central subfield, there was a significant decrease of thickness for all layers (P < 0.05) except the outer nuclear layer. Multiple linear regression analysis revealed that thickness decrease of the inner retina was associated with better visual acuity, whereas for the outer retina the opposite was true. The best estimate of final visual acuity (R = 0.817, P < 0.001) was obtained, by including baseline visual acuity and thickness change of the inner and outer plexiform layers in the model. CONCLUSION Whereas thickness decrease of the inner retina was positively associated with visual acuity gain, the opposite was found for the outer retina. This might be indirect evidence for recovery of the outer retina during ranibizumab treatment.This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License 4.0 (CC BY-NC-ND), which permits downloading and sharing the work provided it is properly cited. The work cannot be changed in any way or used commercially.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Purpose: The P23H rhodopsin mutation is an autosomal dominant cause of retinitis pigmentosa (RP). The degeneration can be tracked using different anatomical and functional methods. In our case, we evaluated the anatomical changes using Spectral-Domain Optical Coherence Tomography (SD-OCT) and correlated the findings with retinal thickness values determined by immunocytochemistry.Methods: Pigmented rats heterozygous for the P23H mutation, with ages between P18 and P180 were studied. Function was assessed by means of optomotor testing and ERGs. Retinal thicknesses measurements, autofluorescence and fluorescein angiography were performed using Spectralis OCT. Retinas were studied by means of immunohistochemistry. Results: Between P30 and P180, visual acuity decreased from 0.500 to 0.182 cycles per degree (cyc/deg) and contrast sensitivity decreased from 54.56 to 2.98 for a spatial frequency of 0.089 cyc/deg. Only cone-driven b-wave responses reached developmental maturity. Flicker fusions were also comparable at P29 (42 Hz). Double flash-isolated rod-driven responses were already affected at P29. Photopic responses revealed deterioration after P29.A reduction in retinal thicknesses and morphological modifications were seen in OCT sections. Statistically significant differences were found in all evaluated thicknesses. Autofluorescence was seen in P23H rats as sparse dots. Immunocytochemistry showed a progressive decrease in the outer nuclear layer (ONL), and morphological changes. Although anatomical thickness measures were significantly lower than OCT values, there was a very strong correlation between the values measured by both techniques.Conclusions: In pigmented P23H rats, a progressive deterioration occurs in both retinal function and anatomy. Anatomical changes can be effectively evaluated using SD-OCT and immunocytochemistry, with a good correlation between their values, thus making SD-OCT an important tool for research in retinal degeneration.