931 resultados para REPEATED TORQUE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We assessed knee extensor neuromuscular adjustments following repeated treadmill sprints in different normobaric hypoxia conditions, with special reference to rapid muscle torque production capacity. Thirteen team- and racquet-sport athletes undertook 8 × 5-s "all-out" sprints (passive recovery = 25 s) on a non-motorized treadmill in normoxia (NM; FiO2 = 20.9%), at low (LA; FiO2 = 16.8%) and high (HA; FiO2 = 13.3%) normobaric hypoxia (simulated altitudes of ~1800 m and ~3600 m, respectively). Explosive (~1 s; "fast" instruction) and maximal (~5 s; "hard" instruction) voluntary isometric contractions (MVC) of the knee extensors (KE), with concurrent electromyographic (EMG) activity recordings of the vastus lateralis (VL) and rectus femoris (RF) muscles, were performed before and 1-min post-exercise. Rate of torque development (RTD) and EMG (i.e., Root Mean Square or RMS) rise from 0 to 30, -50, -100, and -200 ms were recorded, and were also normalized to maximal torque and EMG values, respectively. Distance covered during the first 5-s sprint was similar (P > 0.05) in all conditions. A larger (P < 0.05) sprint decrement score and a shorter (P < 0.05) cumulated distance covered over the eight sprints occurred in HA (-8 ± 4% and 178 ± 11 m) but not in LA (-7 ± 3% and 181 ± 10 m) compared to NM (-5 ± 2% and 183 ± 9 m). Compared to NM (-9 ± 7%), a larger (P < 0.05) reduction in MVC torque occurred post-exercise in HA (-14 ± 9%) but not in LA (-12 ± 7%), with no difference between NM and LA (P > 0.05). Irrespectively of condition (P > 0.05), peak RTD (-6 ± 11%; P < 0.05), and normalized peak RMS activity for VL (-8 ± 11%; P = 0.07) and RF (-14 ± 11%; P < 0.01) muscles were reduced post-exercise, whereas reductions (P < 0.05) in absolute RTD occurred within the 0-100 (-8 ± 9%) and 0-200 ms (-10 ± 8%) epochs after contraction onset. After normalization to MVC torque, there was no difference in RTD values. Additionally, the EMG rise for VL muscle was similar (P > 0.05), whereas it increased (P < 0.05) for RF muscle during all epochs post-exercise, independently of the conditions. In summary, alteration in repeated-sprint ability and post-exercise MVC decrease were greater at high altitude than in normoxia or at low altitude. However, the post-exercise alterations in RTD were similar between normoxia and low-to-high hypoxia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives Bacterial penetration along the implant-abutment interface as a consequence of abutment screw loosening has been reported in a number of recent studies. The aim of this in vitro study was to investigate the influence of repeated tightening of the abutment screw on leakage of Streptococcus mutans along the interface between implants and pre-machined abutments. Materials and methods Twenty pre-machined abutments with a plastic sleeve were used. The abutment screws were tightened to 32 N cm in group 1 (n=10 - control) and to 32 N cm, loosened and re-tightened with the same torque twice in group 2 (n=10). The assemblies were completely immersed in 5 ml of Tryptic Soy Broth medium inoculated with S. mutans and incubated for 14 days. After this period, contamination of the implant internal threaded chamber was evaluated using the DNA Checkerboard method. Results Microorganisms were found on the internal surfaces of both groups evaluated. However, bacterial counts in group 2 were significantly higher than that in the control group (P < 0.05). Conclusion These results suggest that bacterial leakage between implants and abutments occurs even under unloaded conditions and at a higher intensity when the abutment screw is tightened and loosened repeatedly. To cite this article:do Nascimento C, Pedrazzi V, Kirsten Miani P, Daher Moreira L, de Albuquerque Junior RF. Influence of repeated screw tightening on bacterial leakage along the implant-abutment interface.Clin. Oral Impl. Res. 20, 2009; 1394-1397.doi: 10.1111/j.1600-0501.2009.01769.x.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The literature reports that the eccentric muscular action produces greater force and lower myoelectric activity than the concentric muscular action, while the heart rate (HR) responses are bigger during concentric contraction. Objectives: To investigate the maximum average torque (MAT), surface electromyographic (SEMG) and the heart rate (HR) responses during different types of muscular contraction and angular velocities in older men. Methods: Twelve healthy men (61.7 +/- 1.6years) performed concentric (C) and eccentric (E) isokinetic knee extension-flexion at 60 degrees/s and 120 degrees/s. SEMG activity was recorded from vastus lateralis muscle and normalized by Root Mean Square-RMS (mu V) of maximal isometric knee extension at 60 degrees. HR (beats/min) and was recorded at rest and throughout each contraction. The data were analyzed by the Friedman test for repeated measures with post hoc Dunn's test (p<0.05). Results: The median values of MAT (N.m/kg) was smaller and the RMS (mu V) was larger during concentric contraction (C60 degrees/s=2.80 and 0.99; C120 degrees/s=2.46 and 1.0) than eccentric (E60 degrees/s=3.94 and 0.85; E120 degrees/s=4.08 and 0.89), respectively. The HR variation was similar in the four conditions studied. Conclusion: The magnitude of MAT and RMS responses in older men were dependent of the nature of the muscular action and independent of the angular velocity, whereas HR response was not influenced by these factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ankle sprains represent the most common injuries in sports and basketball. In this sense, the use of ankle bracing and strength capacity analysis of the ankle evertor and invertor muscles, have been suggested as preventive measures and important tools for identifying risk factors associated with ankle sprains. However, questions still persist as to effect of the use ankle bracing on biomechanical variables related to the stability of the ankle. For this reason, this study aims to analyze the effect of the use of ankle bracing on peak torque (PT) of ankle evertor and invertor muscles and on eccentric evertor/concentric invertor torque ratio (EVEECC/INVCON), during the basketball match-play simulation. Ten healthy college basketball players, without mechanics or functional ankle instability performed a laboratory-based protocol representative of work rates observed during basketball match-play, in two different situations, with and without use of ankle bracing. The test was composed of a succession of intermittent physical effort equally distributed in four periods of 10 minutes each, considering the mechanical and physiological demands of a basketball match-play. Prior to the start of the trial (Evaluation 1) and after 2° (Evaluation 2) and 4° (Evaluation 3) periods, the subjects performed five maximal isokinetic concentric and eccentric contractions of ankle invertor and evertor muscles, separated by two minutes rest, at 60 °/s and 120 °/s. After testing for normality of data distribution with the Shapiro-Wilk test, was used the ANOVA repeated measures for two factors and post-hoc Bonferroni test for comparison of variables between assessments. Was adopted p < 0.05. There was no significant difference for PT and EVEECC/INVCON torque ratio between assessments. There was a decrease in PT EVEECC at 60º/s and 120º/s for the ...(Complete abstract click electronic access below)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to investigate the influence of previous active static stretch on the isometric peak torque (PT) and rate of force development (RFD) measured from different time intervals from the beginning of muscle contraction. Participated of this study 15 male individuals, apparently healthy, with ages between 18 and 25 years, without regular physical activity practice. The individuals were submitted in different days to the following tests: 1) Familiarization session to the isokinetic dynamometer; 2) Two maximal isometric concentric contractions for knee extensors in isokinetic dynamometer to determine PT and RFD (Control), and; 3) Two active static stretching exercises for the dominant leg extensors (10 x 30 s for each exercise, with 20 s of rest). After the stretching, the isokinetic test was repeated (Post-Stretching). The conditions 2 and 3 were performed in random order. The RFD was considered as the mean slope of the moment-time curve at time intervals of 0-30, 0-50 and 0-100ms relative to the beginning of muscle contraction. It was verified significant reduction for both maximal RFD and PT after the stretching (p < 0.05). At intervals of 0- 30ms, 0-50ms and 0-100ms, the RFD at the conditions with stretching was similar to the RFD without stretching (p > 0.05). At intervals of 0-150ms and 0-200ms, the RFD obtained at the contraction without stretching was significantly higher that that obtained at the contraction with stretching (p < 0.05). It can be concluded that the static stretching, performed with duration of 600 s diminish isometric PT, maximal RFD and RFD measured at late phase (> 100 ms) of muscle contraction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to investigate the influence of previous active static stretch on the peak torque (PT) and rate of force development (TDF) during isokinetic concentric contractions at 60 and 180.s-1 in active individuals. Twelve active subjects with ages between 18 and 30 years participated of this study. The individuals were submitted in different days to the following tests: 1) Familiarization session to the isokinetic dynamometer; 2) Five maximal isokinetic concentric contractions for knee extensors at each angular velocity (60 and 180.s-1) to determine PT and TDF (Control), and; 3) Two active static stretching exercises for the dominant leg extensors (10 x 30 s for each exercise, with 20 s of rest). After the stretching, the isokinetic test was repeated (Post-Stretching). The conditions 2 and 3 were performed in random order. There was no significant modification after the stretch exercises on the PT, angle and time at which the PT was attained, at 60 and 180º.s-1. In the same way, there was no significant modification on the TDF and angle at which the maximal TDF was attained in both angular speeds. In other way, the time to attain maximal TDF (TTDF) at 180º.s-1 was significantly lower after the stretching (Pre - 98.3 ± 27.5 ms and Post - 86.6 ± 30.2 ms). There was significant modification on the torque (60 and 180º.s-1) and time (60º.s-1) at different delta of angle variations, obtained at 60º.s-1 at Control and Post-Stretching conditions. However, there was significant reduction of time after the stretching exercises on delta of angle variations of 90-88º (Pre - 46.6 ± 6.5 ms and Post - 44.1 ± 5.1 ms), 88-85º (Pre - 65.8 ± 7.9 ms and Post - 63.3 ± 4.9 ms) and 85-80º (Pre - 93.3 ± 7.7 ms and Post - 90.0 ± 4.2 ms) at 180º.s-1. With base on these data, it is possible to conclude that PT and TDF do not modify after static stretching, irrespectively on the speed...(Complete abstract click electronic access below)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the variation in removal torque of implant prosthetic abutment screws after successive tightening and loosening cycles, in addition to evaluating the influence of the hexagon at the abutment base on screw removal torque. Material and methods: Twenty hexagonal abutments were tightened to 20 regular external hex implants with a titanium alloy screw, with an insertion torque of 32 N cm, measured with a digital torque gauge. The implant/abutment/screw assemblies were divided into two groups: ( 1) abutments without hexagon at the base and ( 2) abutments with a hexagon at the base. Each assembly received a provisional restoration and was submitted to mechanical loading cycles. After this, the screws were removed and the removal torque was measured. This sequence was repeated 10 times, then the screw was replaced by a new one, and another cycle was performed. Linear regression analysis was performed. Results: Removal torque values tended to decrease as the number of insertion/removal cycles increased, for both groups. Comparisons of the slopes and the intercepts between groups showed no statistical difference. There was no significant difference between the mean values of last five cycles and the 11th cycle. Within the limitations of this in vitro study, it was concluded that ( 1) repeated insertion/removal cycles promoted gradual reduction in removal torque of screws, ( 2) replacing the screw with a new one after 10 cycles did not increase resistance to loosening, and ( 3) removal of the hexagon from the abutment base had no effect on the removal torque of the screws.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study Design. Ex vivo study of the mechanical performance of cylindrical and dual-core pedicle screws after insertion, removal, and reinsertion in the same hole. Objective. To evaluate the effect of repeated use of same screw hole on the insertion torque and the retentive strength of the cylindrical and dual-core screws. Summary of Background Data. Insertion and removal of pedicle screws is sometimes necessary during surgical procedure to assess the integrity of the pilot-hole wall. However, this maneuver may compromise the implant-holding capacity. Methods. Sixty thoracolombar vertebrae (T13-L5), harvested from 10 healthy calves, were used to insert 2 different designs of pedicle screws: cylindrical (5.0-mm outer diameter) and dual-core screws (5.2-mm outer diameter). Three experimental groups were created on the basis of the number of insertions of the screws and 2 subgroups were established according to the core pedicle screw design (dual-core and cylindrical). The insertion torque was measured during initial insertion, second insertion, and third insertion. Pullout screw tests were performed using a universal testing machine to evaluate the pullout strength after initial insertion, second insertion, and third insertion. Results. Significant reductions of 38% in mean insertion torque and 30% in mean pullout strength of dual-core screw were observed between the initial insertion and the third insertion. The cylindrical screw observed significant reductions of 52.5% in mean insertion torque and 42.3% in mean pullout strength between the initial insertion and the third insertion. A reduction of mean insertion torque and pullout strength between the first insertion and the second insertion but without significance was also observed for both types of screws. Conclusion. Insertions and reinsertion of either cylindrical or dual-core pedicle screws have compromised insertion torque and pullout strength of the implants as measured by mechanical tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets generated the highest moments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study we attempted to identify the principles that govern the changes in neural control that occur during repeated performance of a multiarticular coordination task. Eight participants produced isometric flexion/extension and pronation/supination torques at the radiohumeral joint, either in isolation (e.g., flexion) or in combination (e.g., flexion - supination), to acquire targets presented by a visual display. A cursor superimposed on the display provided feedback of the applied torques. During pre- and postpractice tests, the participants acquired targets in eight directions located either 3.6 cm (20% maximal voluntary contraction [MVC]) or 7.2 cm (40% MVC) from a neutral cursor position. On each of five consecutive days of practice the participants acquired targets located 5.4 cm (30% MVC) from the neutral position. EMG was recorded from eight muscles contributing to torque production about the radiohumeral joint during the pre- and posttests. Target-acquisition time decreased significantly with practice in most target directions and at both target torque levels. These performance improvements were primarily associated with increases in the peak rate of torque development after practice. At a muscular level, these changes were brought about by increases in the rates of recruitment of all agonist muscles. The spatiotemporal organization of muscle synergies was not significantly altered after practice. The observed adaptations appear to lead to performances that are generalizable to actions that require both greater and smaller joint torques than that practiced, and may be successfully recalled after a substantial period without practice. These results suggest that tasks in which performance is improved by increasing the rate of muscle activation, and thus the rate of joint torque development, may benefit in terms of the extent to which acquired levels of performance are maintained over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recently-proposed Bethesda reporting system has offered clinical recommendations for each category of reported thyroid cytology, including repeated fine-needle aspiration (FNA) for non-diagnostic and atypia/follicular lesions of undetermined significance, but there are no sound indications for repeated examination after an initial benign exam. To investigate the clinical validity of repeated FNA in the management of patients with thyroid nodules. The present study evaluated 412 consecutive patients who had repeated aspiration biopsies of thyroid nodules after an initial non-diagnostic, atypia/follicular lesion of undetermined significance, or benign cytology. The majority of patients were female (93.5%) ranging from 13 to 83 years. Non-diagnostic cytology was the most common indication for a repeated examination in 237 patients (57.5%), followed by benign (36.8%), and A/FLUS (5.6%) cytology. A repeated examination altered the initial diagnosis in 70.5% and 78.3% of the non-diagnostic and A/FLUS patients, respectively, whereas only 28.9% of patients with a benign cytology presented with a different diagnosis on a sequential FNA. Repeat FNA is a valuable procedure in cases with initial non-diagnostic or A/FLUS cytology, but its routine use for patients with an initial benign examination appears to not increase the expected likelihood of a malignant finding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física