941 resultados para RAPID ANALYSIS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Office of Special Investigations at Iowa Department of Transportation (DOT) collects FWD data on regular basis to evaluate pavement structural conditions. The primary objective of this study was to develop a fully-automated software system for rapid processing of the FWD data along with a user manual. The software system automatically reads the FWD raw data collected by the JILS-20 type FWD machine that Iowa DOT owns, processes and analyzes the collected data with the rapid prediction algorithms developed during the phase I study. This system smoothly integrates the FWD data analysis algorithms and the computer program being used to collect the pavement deflection data. This system can be used to assess pavement condition, estimate remaining pavement life, and eventually help assess pavement rehabilitation strategies by the Iowa DOT pavement management team. This report describes the developed software in detail and can also be used as a user-manual for conducting simulation studies and detailed analyses. *********************** Large File ***********************

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC–QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Paspalum dilatatum is a valuable forage grass in the subtropics. This species consists of several sexual (tetraploid) and apomict (penta- and hexaploid) biotypes. It has been proposed that the presence of a genome of unknown origin, the X genome, is responsible for apomixis in penta- and hexaploid biotypes. Here we evaluated the utility of random amplified polymorphic DNA (RAPD) markers for discriminating sexual and apomictic P dilatatum biotypes. DNA samples from nine accessions, including P. intermedium, P. juergensh, and P dilatatum (ssp. flavescens, and the common and Uruguayan biotypes) were analyzed with 86 RAPID primers. Three hundred sixty-two fragments were scored and genetic similarity estimates revealed that the penta- and hexaploid biotypes were highly similar (S,, greater than or equal to 0.913). Forty RAPDs were unique to the penta- and hexaploid biotypes. Overall RAPID markers were useful for assessing genetic variation among closely related P dilatatum genotypes as well as generating putative X genome markers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Centrifuge is a user-friendly system to simultaneously access Arabidopsis gene annotations and intra- and inter-organism sequence comparison data. The tool allows rapid retrieval of user-selected data for each annotated Arabidopsis gene providing, in any combination, data on the following features: predicted protein properties such as mass, pI, cellular location and transmembrane domains; SWISS-PROT annotations; Interpro domains; Gene Ontology records; verified transcription; BLAST matches to the proteomes of A.thaliana, Oryza sativa (rice), Caenorhabditis elegans, Drosophila melanogaster and Homo sapiens. The tool lends itself particularly well to the rapid analysis of contigs or of tens or hundreds of genes identified by high-throughput gene expression experiments. In these cases, a summary table of principal predicted protein features for all genes is given followed by more detailed reports for each individual gene. Centrifuge can also be used for single gene analysis or in a word search mode. AVAILABILITY: http://centrifuge.unil.ch/ CONTACT: edward.farmer@unil.ch.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. RESULTS: The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. CONCLUSION: The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Trichophyton rubrum is the most common pathogen causing dermatophytosis. Molecular strain-typing methods have recently been developed to tackle epidemiological questions and the problem of relapse following treatment. A total of 67 strains of T rubrum were screened for genetic variation by randomly amplified polymorphic DNA (RAPD) analysis, with two primers, 5'-d[GGTGCGGGAA]-3' and 5'-d[CCCGTCAGCA]-3', as well as by subrepeat element analysis of the nontranscribed spacer of rDNA, using the repetitive subelements TRS-1 and TRS-2. A total of 12 individual patterns were recognized with the first primer and 11 with the second. Phylogenetic analysis of the RAPID products showed a high degree of similarity (> 90 %) among the epidemiologically related clinical isolates, while the other strains possessed 60% similarity. Specific amplification of TRS-1 produced three strain-characteristic banding patterns (PCR types); simple patterns representing one copy of TRS-1 and two copies of TRS-2 accounted for around 85 % of all isolates. It is concluded that molecular analysis has important implications for epidemiological studies, and RAPID analysis is especially suitable for molecular typing in T. rubrum.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to identify novel biomarkers for thyroid carcinoma diagnosis and prognosis. We have constructed a human single-chain variable fragment (scFv) antibody library that was selected against tumour thyroid cells using the BRASIL method (biopanning and rapid analysis of selective interactive ligands) and phage display technology. One highly reactive clone, scFv-C1, with specific binding to papillary thyroid tumour proteins was confirmed by ELISA, which was further tested against a tissue microarray that comprised of 229 thyroid tissues, including: 110 carcinomas (38 papillary thyroid carcinomas (PTCs), 42 follicular carcinomas, 30 follicular variants of PTC), 18 normal thyroid tissues, 49 nodular goitres (NG) and 52 follicular adenomas. The scFv-C1 was able to distinguish carcinomas from benign lesions (P=0.0001) and reacted preferentially against T1 and T2 tumour stages (P=0.0108). We have further identified an OTU domain-containing protein 1, DUBA-7 deubiquitinating enzyme as the scFv-binding antigen using two-dimensional polyacrylamide gel electrophoresis and mass spectrometry. The strategy of screening and identifying a cell-surface-binding antibody against thyroid tissues was highly effective and resulted in a useful biomarker that recognises malignancy among thyroid nodules and may help identify lower-risk cases that can benefit from less-aggressive management.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Paraquat is a broad-spectrum contact herbicide that has been encountered worldwide in several cases of accidental, homicidal, and suicidal poisonings. The pulmonary toxicity of this compound is related to the depletion of NADPH in the pneumocytes, which is continuously consumed by the reduction/oxidation of paraquat and reductase enzyme systems in the presence of O(2) (redox cycling). Based on this mechanism, an enzymatic-spectrophotometric method was developed for the determination of paraquat in urine samples. The velocity of NADPH consumption was monitored at 340 nm, every 10 s during 15 min. The velocity of NADPH oxidation correlated with the paraquat levels found in samples. The enzymatic-spectrophotometric method showed to be sensitive, making possible the detection of paraquat in urine samples at concentrations as low as 0.05 mg/L.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

გეორადიოლოკაციური მეთოდით კვლევის ობიექტს წარმოადგენს ჩაქვი-ბათუმის ავტოსაგზაო გვირაბის თაღის ზედა ნაწილი. სამუშაოს მიზანს წარმოადგენდა გვირაბის ბეტონის საფარის ხარისხის დადგენა. კერძოდ ჰაერის სიღრუვეების აღმოჩენა ბეტონის ფენაში. ჰაერის შემცველი სიღრუვეების არსებობის დამადასტურებელი ნიშნები ამ ერთ პროფილზე, 2 გჰც. ანტენით არ შეინიშნება, რაც მეტყველებს საკვლევ მონაკვეთებზე შესრულებული ბეტონის სამუშაოების კარგ ხარისხზე.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A transportable Raman spectrometer was tested for the detection of illicit drugs seized during border controls. In a first step, the analysis methodology was optimized using reference substances such as diacetylmorphine (heroin), cocaine and amphetamine (as powder or liquid forms). Adequate focalisation distance and times of analysis, influence of daylight and artificial light sources, repeatability and limits of detection were studied. In a second step the applications and limitations of the technique to detect the illicit substances in different mixtures and containers was evaluated. Transportable Raman spectroscopy was found to be adequate for a rapid screen of liquids and powders for the detection and identification of controlled substances. Additionally, it had the advantage over other portable techniques, such as ion mobility spectrometry, of being non-destructive and capable of rapid analysis of large quantities of substances through containers such as plastic bags and glass bottles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Paper-based analytical technologies enable quantitative and rapid analysis of analytes from various application areas including healthcare, environmental monitoring and food safety. Because paper is a planar, flexible and light weight substrate, the devices can be transported and disposed easily. Diagnostic devices are especially valuable in resourcelimited environments where diagnosis as well as monitoring of therapy can be made even without electricity by using e.g. colorimetric assays. On the other hand, platforms including printed electrodes can be coupled with hand-held readers. They enable electrochemical detection with improved reliability, sensitivity and selectivity compared with colorimetric assays. In this thesis, different roll-to-roll compatible printing technologies were utilized for the fabrication of low-cost paper-based sensor platforms. The platforms intended for colorimetric assays and microfluidics were fabricated by patterning the paper substrates with hydrophobic vinyl substituted polydimethylsiloxane (PDMS) -based ink. Depending on the barrier properties of the substrate, the ink either penetrates into the paper structure creating e.g. microfluidic channel structures or remains on the surface creating a 2D analog of a microplate. The printed PDMS can be cured by a roll-ro-roll compatible infrared (IR) sintering method. The performance of these platforms was studied by printing glucose oxidase-based ink on the PDMS-free reaction areas. The subsequent application of the glucose analyte changed the colour of the white reaction area to purple with the colour density and intensity depending on the concentration of the glucose solution. Printed electrochemical cell platforms were fabricated on paper substrates with appropriate barrier properties by inkjet-printing metal nanoparticle based inks and by IR sintering them into conducting electrodes. Printed PDMS arrays were used for directing the liquid analyte onto the predetermined spots on the electrodes. Various electrochemical measurements were carried out both with the bare electrodes and electrodes functionalized with e.g. self assembled monolayers. Electrochemical glucose sensor was selected as a proof-of-concept device to demonstrate the potential of the printed electronic platforms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Les cyanobactéries ont une place très importante dans les écosystèmes aquatiques et un nombre important d’espèces considéré comme nuisible de par leur production de métabolites toxiques. Ces cyanotoxines possèdent des propriétés très variées et ont souvent été associées à des épisodes d’empoisonnement. L’augmentation des épisodes d’efflorescence d’origine cyanobactériennes et le potentiel qu’ils augmentent avec les changements climatiques a renchéri l’intérêt de l’étude des cyanobactéries et de leurs toxines. Considérant la complexité chimique des cyanotoxines, le développement de méthodes de détection simples, sensibles et rapides est toujours considéré comme étant un défi analytique. Considérant ces défis, le développement de nouvelles approches analytiques pour la détection de cyanotoxines dans l’eau et les poissons ayant été contaminés par des efflorescences cyanobactériennes nuisibles a été proposé. Une première approche consiste en l’utilisation d’une extraction sur phase solide en ligne couplée à une chromatographie liquide et à une détection en spectrométrie de masse en tandem (SPE-LC-MS/MS) permettant l’analyse de six analogues de microcystines (MC), de l’anatoxine (ANA-a) et de la cylindrospermopsine (CYN). La méthode permet une analyse simple et rapide et ainsi que la séparation chromatographique d’ANA-a et de son interférence isobare, la phénylalanine. Les limites de détection obtenues se trouvaient entre 0,01 et 0,02 μg L-1 et des concentrations retrouvées dans des eaux de lacs du Québec se trouvaient entre 0,024 et 36 μg L-1. Une deuxième méthode a permis l’analyse du b-N-méthylamino-L-alanine (BMAA), d’ANA-a, de CYN et de la saxitoxine (STX) dans les eaux de lac contaminés. L’analyse de deux isomères de conformation du BMAA a été effectuée afin d’améliorer la sélectivité de la détection. L’utilisation d’une SPE manuelle permet la purification et préconcentration des échantillons et une dérivatisation à base de chlorure de dansyle permet une chromatographie simplifiée. L’analyse effectuée par LC couplée à la spectrométrie de masse à haute résolution (HRMS) et des limites de détections ont été obtenues entre 0,007 et 0,01 µg L-1. Des échantillons réels ont été analysés avec des concentrations entre 0,01 et 0,3 µg L-1 permettant ainsi la confirmation de la présence du BMAA dans les efflorescences de cyanobactéries au Québec. Un deuxième volet du projet consiste en l’utilisation d’une technologie d’introduction d’échantillon permettant des analyses ultra-rapides (< 15 secondes/échantillons) sans étape chromatographique, la désorption thermique à diode laser (LDTD) couplée à l’ionisation chimique à pression atmosphérique (APCI) et à la spectrométrie de masse (MS). Un premier projet consiste en l’analyse des MC totales par l’intermédiaire d’une oxydation de Lemieux permettant un bris de la molécule et obtenant une fraction commune aux multiples congénères existants des MC. Cette fraction, le MMPB, est analysée, après une extraction liquide-liquide, par LDTD-APCI-MS/MS. Une limite de détection de 0,2 µg L-1 a été obtenue et des concentrations entre 1 et 425 µg L-1 ont été trouvées dans des échantillons d’eau de lac contaminés du Québec. De plus, une analyse en parallèle avec des étalons pour divers congénères des MC a permis de suggérer la possible présence de congénères ou d’isomères non détectés. Un deuxième projet consiste en l’analyse directe d’ANA-a par LDTD-APCI-HRMS pour résoudre son interférence isobare, la phénylalanine, grâce à la détection à haute résolution. La LDTD n’offre pas de séparation chromatographique et l’utilisation de la HRMS permet de distinguer les signaux d’ANA-a de ceux de la phénylalanine. Une limite de détection de 0,2 µg L-1 a été obtenue et la méthode a été appliquée sur des échantillons réels d’eau avec un échantillon positif en ANA-a avec une concentration de 0,21 µg L-1. Finalement, à l’aide de la LDTD-APCI-HRMS, l’analyse des MC totales a été adaptée pour la chair de poisson afin de déterminer la fraction libre et liée des MC et comparer les résultats avec des analyses conventionnelles. L’utilisation d’une digestion par hydroxyde de sodium précédant l’oxydation de Lemieux suivi d’une purification par SPE a permis d’obtenir une limite de détection de 2,7 µg kg-1. Des échantillons de poissons contaminés ont été analysés, on a retrouvé des concentrations en MC totales de 2,9 et 13,2 µg kg-1 comparativement aux analyses usuelles qui avaient démontré un seul échantillon positif à 2 µg kg-1, indiquant la possible présence de MC non détectés en utilisant les méthodes conventionnelles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La protéomique est un sujet d'intérêt puisque l'étude des fonctions et des structures de protéines est essentiel à la compréhension du fonctionnement d'un organisme donné. Ce projet se situe dans la catégorie des études structurales, ou plus précisément, la séquence primaire en acides aminés pour l’identification d’une protéine. La détermination des protéines commence par l'extraction d'un mélange protéique issu d'un tissu ou d'un fluide biologique pouvant contenir plus de 1000 protéines différentes. Ensuite, des techniques analytiques comme l’électrophorèse en gel polyacrylamide en deux dimensions (2D-SDS-PAGE), qui visent à séparer ce mélange en fonction du point isoélectrique et de la masse molaire des protéines, sont utilisées pour isoler les protéines et pour permettre leur identification par chromatographie liquide and spectrométrie de masse (MS), typiquement. Ce projet s'inspire de ce processus et propose que l'étape de fractionnement de l'extrait protéique avec la 2D-SDS-PAGE soit remplacé ou supporté par de multiples fractionnements en parallèle par électrophorèse capillaire (CE) quasi-multidimensionnelle. Les fractions obtenues, contenant une protéine seule ou un mélange de protéines moins complexe que l’extrait du départ, pourraient ensuite être soumises à des identifications de protéines par cartographie peptidique et cartographie protéique à l’aide des techniques de séparations analytiques et de la MS. Pour obtenir la carte peptidique d'un échantillon, il est nécessaire de procéder à la protéolyse enzymatique ou chimique des protéines purifiées et de séparer les fragments peptidiques issus de cette digestion. Les cartes peptidiques ainsi générées peuvent ensuite être comparées à des échantillons témoins ou les masses exactes des peptides enzymatiques sont soumises à des moteurs de recherche comme MASCOT™, ce qui permet l’identification des protéines en interrogeant les bases de données génomiques. Les avantages exploitables de la CE, par rapport à la 2D-SDS-PAGE, sont sa haute efficacité de séparation, sa rapidité d'analyse et sa facilité d'automatisation. L’un des défis à surmonter est la faible quantité de masse de protéines disponible après analyses en CE, due partiellement à l'adsorption des protéines sur la paroi du capillaire, mais due majoritairement au faible volume d'échantillon en CE. Pour augmenter ce volume, un capillaire de 75 µm était utilisé. Aussi, le volume de la fraction collectée était diminué de 1000 à 100 µL et les fractions étaient accumulées 10 fois; c’est-à-dire que 10 produits de séparations étaient contenu dans chaque fraction. D'un autre côté, l'adsorption de protéines se traduit par la variation de l'aire d'un pic et du temps de migration d'une protéine donnée ce qui influence la reproductibilité de la séparation, un aspect très important puisque 10 séparations cumulatives sont nécessaires pour la collecte de fractions. De nombreuses approches existent pour diminuer ce problème (e.g. les extrêmes de pH de l’électrolyte de fond, les revêtements dynamique ou permanent du capillaire, etc.), mais dans ce mémoire, les études de revêtement portaient sur le bromure de N,N-didodecyl-N,N-dimethylammonium (DDAB), un surfactant qui forme un revêtement semi-permanent sur la paroi du capillaire. La grande majorité du mémoire visait à obtenir une séparation reproductible d'un mélange protéique standard préparé en laboratoire (contenant l’albumine de sérum de bovin, l'anhydrase carbonique, l’α-lactalbumine et la β-lactoglobulin) par CE avec le revêtement DDAB. Les études portées sur le revêtement montraient qu'il était nécessaire de régénérer le revêtement entre chaque injection du mélange de protéines dans les conditions étudiées : la collecte de 5 fractions de 6 min chacune à travers une séparation de 30 min, suivant le processus de régénération du DDAB, et tout ça répété 10 fois. Cependant, l’analyse en CE-UV et en HPLC-MS des fractions collectées ne montraient pas les protéines attendues puisqu'elles semblaient être en-dessous de la limite de détection. De plus, une analyse en MS montrait que le DDAB s’accumule dans les fractions collectées dû à sa désorption de la paroi du capillaire. Pour confirmer que les efforts pour recueillir une quantité de masse de protéine étaient suffisants, la méthode de CE avec détection par fluorescence induite par laser (CE-LIF) était utilisée pour séparer et collecter la protéine, albumine marquée de fluorescéine isothiocyanate (FITC), sans l'utilisation du revêtement DDAB. Ces analyses montraient que l'albumine-FITC était, en fait, présente dans la fraction collecté. La cartographie peptidique a été ensuite réalisée avec succès en employant l’enzyme chymotrypsine pour la digestion et CE-LIF pour obtenir la carte peptidique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chemical sensors have growing interest in the determination of food additives, which are creating toxicity and may cause serious health concern, drugs and metal ions. A chemical sensor can be defined as a device that transforms chemical information, ranging from the concentration of a specific sample component to total composition analysis, into an analytically useful signal. The chemical information may be generated from a chemical reaction of the analyte or from a physical property of the system investigated. Two main steps involved in the functioning of a chemical sensor are recognition and transduction. Chemical sensors employ specific transduction techniques to yield analyte information. The most widely used techniques employed in chemical sensors are optical absorption, luminescence, redox potential etc. According to the operating principle of the transducer, chemical sensors may be classified as electrochemical sensors, optical sensors, mass sensitive sensors, heat sensitive sensors etc. Electrochemical sensors are devices that transform the effect of the electrochemical interaction between analyte and electrode into a useful signal. They are very widespread as they use simple instrumentation, very good sensitivity with wide linear concentration ranges, rapid analysis time and simultaneous determination of several analytes. These include voltammetric, potentiometric and amperometric sensors. Fluorescence sensing of chemical and biochemical analytes is an active area of research. Any phenomenon that results in a change of fluorescence intensity, anisotropy or lifetime can be used for sensing. The fluorophores are mixed with the analyte solution and excited at its corresponding wavelength. The change in fluorescence intensity (enhancement or quenching) is directly related to the concentration of the analyte. Fluorescence quenching refers to any process that decreases the fluorescence intensity of a sample. A variety of molecular rearrangements, energy transfer, ground-state complex formation and collisional quenching. Generally, fluorescence quenching can occur by two different mechanisms, dynamic quenching and static quenching. The thesis presents the development of voltammetric and fluorescent sensors for the analysis of pharmaceuticals, food additives metal ions. The developed sensors were successfully applied for the determination of analytes in real samples. Chemical sensors have multidisciplinary applications. The development and application of voltammetric and optical sensors continue to be an exciting and expanding area of research in analytical chemistry. The synthesis of biocompatible fluorophores and their use in clinical analysis, and the development of disposable sensors for clinical analysis is still a challenging task. The ability to make sensitive and selective measurements and the requirement of less expensive equipment make electrochemical and fluorescence based sensors attractive.