Resumo:
BACKGROUND: A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter.
METHODS: Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies.
RESULTS: There was a reduction in saturation values of 87-90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions.
CONCLUSIONS: A characteristic of the software algorithm reduces the frequency of saturations of 87-90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability.
Resumo:
OBJECTIVE: To test the accuracy of a new pulse oximeter sensor based on transmittance and reflectance. This sensor makes transillumination of tissue unnecessary and allows measurements on the hand, forearm, foot, and lower limb. DESIGN: Prospective, open, nonrandomized criterion standard study. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 54 critically ill neonates (gestational age 27 to 42 wks; postnatal age 1 to 28 days) with arterial catheters in place. MEASUREMENTS AND MAIN RESULTS: A total of 99 comparisons between pulse oximetry and arterial saturation were obtained. Comparison of femoral or umbilical arterial blood with transcutaneous measurements on the lower limb (n = 66) demonstrated an excellent correlation (r2 = .96). The mean difference was +1.44% +/- 3.51 (SD) % (range -11% to +8%). Comparison of the transcutaneous values with the radial artery saturation from the corresponding upper limb (n = 33) revealed a correlation coefficient of 0.94 with a mean error of +0.66% +/- 3.34% (range -6% to +7%). The mean difference between noninvasive and invasive measurements was least with the test sensor on the hand, intermediate on the calf and arm, and greatest on the foot. The mean error and its standard deviation were slightly larger for arterial saturation values < 90% than for values > or = 90%. CONCLUSION: Accurate pulse oximetry saturation can be acquired from the hand, forearm, foot, and calf of critically ill newborns using this new sensor.
Resumo:
We evaluated a new pulse oximeter designed to monitor beat-to-beat arterial oxygen saturation (SaO2) and compared the monitored SaO2 with arterial samples measured by co-oximetry. In 40 critically ill children (112 data sets) with a mean age of 3.9 years (range 1 day to 19 years), SaO2 ranged from 57% to 100%, and PaO2 from 27 to 128 mm Hg, heart rates from 85 to 210 beats per minute, hematocrit from 20% to 67%, and fetal hemoglobin levels from 1.3% to 60%; peripheral temperatures varied between 26.5 degrees and 36.5 degrees C. Linear correlation analysis revealed a good agreement between simultaneous pulse oximeter values and both directly measured SaO2 (r = 0.95) and that calculated from measured arterial PaO2 (r = 0.95). The device detected several otherwise unrecognized drops in SaO2 but failed to function in four patients with poor peripheral perfusion secondary to low cardiac output. Simultaneous measurements with a tcPO2 electrode showed a similarly good correlation with PaO22 (r = 0.91), but the differences between the two measurements were much wider (mean 7.1 +/- 10.3 mm Hg, range -14 to +49 mm Hg) than the differences between pulse oximeter SaO2 and measured SaO2 (1.5% +/- 3.5%, range -7.5% to -9%) and were not predictable. We conclude that pulse oximetry is a reliable and accurate noninvasive device for measuring saturation, which because of its rapid response time may be an important advance in monitoring changes in oxygenation and guiding oxygen therapy.
Resumo:
Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.
Resumo:
This is a participant study, quasi-experimental, of a before and after type. A quantitative approach of biophysiological measures was used, represented by the saturation of oxygen measured by pulse oximeter (SpO2), and recorded on three occasions: before, during and after the bedbath in critically ill patients hospitalized at the ICU of a University Hospital in Brazil. Objective: to compare the SpO2 in various stages of the bath, with and without control of water temperature. Data collection was performed between December 2007 and April 2008 on a convenience sample consisting of 30 patients aged over 18 who had classification in TISS-28 from level II. Results show that water temperature control means a lower variation of SpO2 (p<0.05). No marked differences in variation of saturation between men and women or between age groups were established. In conclusion, heated and constant water temperature during the bedbath is able to minimize the fall of SpO2 that occurs while handling patients during procedures.
Resumo:
Pulse oximetry represents a major advance in patient monitoring, but measurement below 70 to 80% saturation has important limitations. Several authors have tested pulse oximetry at low saturations with conflicting results. A review of these data indicates that every patient with a pulse oximeter value below 75 to 80% SaO2 should have one or more invasive measurements of the arterial SaO2 in order to avoid undetected severe hypoxemia.
Resumo:
We tested the hypothesis that hyperoxemia defined as arterial PO2 above 12 kPa can be detected by pulse oximetry using 95% oxygen saturation as the upper limit. Thirty artificially ventilated neonates with an indwelling arterial catheter were studied registrating transcutaneous oxygen saturation (Ohmeda Biox 3700 Pulse Oximeter) and transcutaneous PO2 continuously during a 4-hour period and measuring arterial oxygen saturation and PO2 intermittently. 46 episodes of arterial hyperoxemia were observed. Pulse oximetry had a sensitivity of 30%, detecting 14 of these 46 hyperoxemic episodes, and a specificity of 93%. The accuracy for separating hyperoxemia from normoxemia by pulse oximetry could be improved by shifting the cut-off point from 95% to 92%. With this optimal cut-off point sensitivity was 70% and specificity 62%. We conclude that pulse oximetry is not reliable for detection of hyperoxemia.
Resumo:
Abstract Background Medical oncologists continue to use performance status as a proxy for quality of life (QOL) measures, as completion of QOL instruments is perceived as time consuming, may measure aspects of QOL not affected by cancer therapy, and interpretation may be unclear. The pulse oximeter is widely used in clinical practice to predict cardiopulmonary morbidity after lung resection in cancer patients, but little is known on its role outside the surgical setting. We evaluated whether the Lung Cancer Symptom Scale and pulse oximetry may contribute to the evaluation of lung cancer patients who received standard anticancer therapy. Methods We enrolled forty-one consecutive, newly diagnosed, patients with locally advanced or metastatic lung cancer in this study. We developed a survival model with the variables gender, age, histology, clinical stage, Karnofsky performance status, wasting, LCSS symptom scores, average symptom burden index, and pulse oximetry (SpO2). Results Patient and observer-rated scores were correlated, except for the fatigue subscale. The median SpO2 was 95% (range: 86 to 98), was unrelated to symptom scores, and was weakly correlated with observer cough scores. In a multivariate survival model, SpO2 > 90% and patient scores on the LCSS appetite and fatigue subscales were independent predictors of survival. Conclusion LCSS fatigue and appetite rating, and pulse oximetry should be studied further as prognostic factors in lung cancer patients.
Resumo:
BACKGROUND: Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. METHODS: Ninety-five patients, ASA I or II, were randomly assigned to five groups [Group 1: bispectral index (BIS) (range) 40-50, effect site remifentanil concentration 1 ng ml(-1);Group 2: BIS 40-50, remifentanil 2 ng ml(-1); Group 3: BIS 40-50, remifentanil 4 ng ml(-1); Group 4: BIS 25-35, remifentanil 2 ng ml(-1); Group 5: BIS 55-65, remifentanil 2 ng ml(-1)]. A 60 mA tetanic stimulus was applied for 5 s on the ulnar nerve. From the digitized pulse oximeter wave recorded on a laptop computer, linear and non-linear parameters of PPG variation during the 60 s period after stimulation were computed. The haemodynamic response to subsequent orotracheal intubation was recorded. The PPG variation was compared between groups and between responders and non-responders to intubation (anova). Variables independently predicting the response were determined by logistic regression. RESULTS: The probability of a response to tracheal intubation was 0.77, 0.47, 0.05, 0.18 and 0.52 in Groups 1-5, respectively (P<0.03). The PPG variability was significantly higher in responders than in non-responders but it did not improve the prediction of the response to tracheal intubation based on BIS level and effect site remifentanil concentration. CONCLUSION: Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesia.
Resumo:
Pulse oximetry is commonly used as an arterial blood oxygen saturation (SaO(2)) measure. However, its other serial output, the photoplethysmography (PPG) signal, is not as well studied. Raw PPG signals can be used to estimate cardiovascular measures like pulse transit time (PTT) and possibly heart rate (HR). These timing-related measurements are heavily dependent on the minimal variability in phase delay of the PPG signals. Masimo SET (R) Rad-9 (TM) and Novametrix Oxypleth oximeters were investigated for their PPG phase characteristics on nine healthy adults. To facilitate comparison, PPG signals were acquired from fingers on the same hand in a random fashion. Results showed that mean PTT variations acquired from the Masimo oximeter (37.89 ms) were much greater than the Novametrix (5.66 ms). Documented evidence suggests that I ms variation in PTT is equivalent to I mmHg change in blood pressure. Moreover, the PTT trend derived from the Masimo oximeter can be mistaken as obstructive sleep apnoeas based on the known criteria. HR comparison was evaluated against estimates attained from an electrocardiogram (ECG). Novametrix differed from ECG by 0.71 +/- 0.58% (p < 0.05) while Masimo differed by 4.51 +/- 3.66% (p > 0.05). Modem oximeters can be attractive for their improved SaO(2) measurement. However, using raw PPG signals obtained directly from these oximeters for timing-related measurements warrants further investigations.
Resumo:
Mestrado em Fisioterapia.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia de Eletrónica e Computadores
Resumo:
This study analyzed the feasibility and efficacy of surgical therapies in patients with sleep-disordered breathing ranging from partial upper airway obstruction during sleep to severe obstructive sleep apnea syndrome. The surgical procedures evaluated were tracheostomy, laser-assisted uvulopalatoplasty (LUPP) and uvulopalatopharyngoplasty (UPPP) with laser or ultrasound scalpel. Obstructive sleep apnea and partial upper airway obstruction during sleep were measured with the static charge-sensitive bed (SCSB) and pulse oximeter. The patients with severe obstructive sleep apnea syndrome were treated with tracheostomy. Palatal surgery was performed only if the upper airway narrowing occurred exclusively at the soft palate level in patients with partial upper airway obstruction during sleep. The ultrasound scalpel technique was compared to laser-assisted UPPP. The efficacy of LUPP to reduce partial upper airway obstruction during sleep was assessed and histology of uvulopalatal specimen was compared to body fat distributional parameters and sleep study findings. Tracheostomy was effective therapy in severe obstructive sleep apnea. Partial upper airway obstruction and arterial oxyhemoglobin desaturation index during sleep decreased significantly after LUPP. The minimal retropalatal airway dimension increased and soft palate collapsibility decreased at the level where the velopharyngeal obstruction had occurred before the surgery. Ultrasound scalpel did not offer any significant benefits over the laser-assisted technique, except fewer postoperative haemorrhage events. The loose connective tissue as a manifestation of edema was the only histological finding showing correlation with partial upper airway obstruction parameters of SCSB. Tracheostomy remains a life-saving therapy and also long-term option when adherence to CPAP fails in patients with obstructive sleep apnea syndrome. LUPP effectively reduces partial upper airway obstruction during sleep provided that obstruction at the other levels than the soft palate and uvula were preoperatively excluded. Technically the ultrasound scalpel or laser surgeries are equal. In patients with partial upper airway obstruction the loose connective tissue is more important than fat accumulation in the soft palate. This supports the hypothesis that edema is a primary trigger for aggravation of upper airway narrowing during sleep at the soft palate level and evolution towards partial or complete upper airway obstruction during sleep.
Resumo:
Introducción: Se ha conocido la necesidad de la monitoria del estado hemodinámico de los pacientes quirúrgicos de forma dinámica, que permita realizar una valoración rápida, menos invasiva y confiable para un diagnóstico acertado y evaluar la respuesta a las conductas tomadas. El delta de pletismografía es una herramienta confiable, no invasiva y dinámica que logra cumplir con las características antes mencionadas y que además puede llegar a tener un papel preponderante en la terapia hídrica dirigida. Metodología: Estudio de correlación, se realizaron evaluaciones sistemáticas de la onda de pletismografía y las variables del paciente desde la inducción anestésica hasta el inicio del procedimiento quirúrgico, se determinó la correlación entre la variabilidad de la onda de pletismografía, el delta de pletismografía y el requerimiento de líquidos intraoperatorios. Se incluyeron pacientes adultos en el rango de 18 a 80 años, que cumplían los criterios de inclusión, programados para cirugía bajo anestesia general en la Fundación Cardioinfantil Instituto de Cardiología, hasta lograr la muestra calculada de 31 pacientes. Siguiendo los principios éticos de la declaración de Helsinki y la normatividad colombiana, este estudio no consideró la realización de ningún tipo de intervención en los pacientes lo que lo cataloga de bajo riesgo. Resultados: El 80.6% presentó variabilidad aumentada, con correlación entre la variabilidad de la onda del pulso, el delta POP y la cantidad de líquidos intraoperatorios (0.245 IC 95%). Disminución del delta POP en T3, sugiriendo respuesta a líquidos, correlación entre uso de vasopresores, analgesia y náuseas y vómito postoperatorio. Conclusión: Existe correlación entre la variabilidad de la onda de pletismografía, el delta de pletismografía y la reposición de líquidos endovenosos en los pacientes ventilados mecánicamente durante anestesia general. Además se encuentra asociación entre uso de vasopresores, analgesia y náuseas y vómito postoperatorio.
Resumo:
Introducción: La simpatectomía es el tratamiento de la hiperhidrosis palmar y consiste en denervación simpática de miembros superiores que produce un efecto en el flujo sanguíneo al impactar la respuesta vasoconstrictora. El cambio en el flujo sanguíneo se puede evaluar a través de la onda fotopletismográfica. Metodología: Se realizaron 2 sesiones (presimpatectomía y postsimpatectomía) de 10 minutos en cada miembro superior en 28 pacientes obteniendo 79 señales fotopletismográficas distribuidas así: 37 presimpatectomía y 42 señales postsimpatectomía. De cada señal se analizó 1.5 minutos donde se tienen 80 ondas de fotopletismografía y se miden 6 variables: 1. Componente AC (componente pulsátil), 2. Componente DC (componente no pulsátil), 3. Relación entre AC/DC (índice de perfusión), 4. Area bajo la curva (AUC), 5. Tiempo entre el inicio de la onda y pico sistólico (T_DA) y 6. Tiempo entre cada onda de pulso (T_DD). Resultados: Aumentó 120% el componente AC y disminuyó 78% en DC del miembro superior derecho (MSD) con 99% de confiabilidad (p<0.001) entre presimpatectomía (n=18) y postsimpatectomía (n=21). AC/DC aumentó 55% con 95% de confiabilidad entre presimpatectomía (n=19) y postsimpatectomía (n=21) en el miembro superior izquierdo (p<0.05). No se encontró diferencia para T_DA, T_DD ni AUC. Discusión y Conclusión: La simpatectomía en pacientes con hiperhidrosis palmar produce un cambio en el flujo sanguíneo de los miembros superiores evidenciado por los cambios en el componente no pulsátil (DC) y pulsátil (AC) que es secundario a la vasodilatación consecuencia del bloqueo simpático por la denervación quirúrgica de los ganglios simpáticos torácicos.