917 resultados para Protese Total


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Immediate functioning of osseointegrated implants has been widely employed in edentulous patients due to its safety and high predictability. However, viability and success of immediate-loaded implants is defined by factors such as number of implants, distribution and splinting, as well as reduction of oblique loads and excessive occlusal contacts. The indirect composite resin-modified glass enable building of a highly aesthetic prosthesis, combining satisfactory resistance and better force dissipation on occlusal loading. This article describes a resin composite, mandibular fixed prosthesis on osseointegrated implants in immediate function.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: the oral rehabilitation in edentulous patients using removable complete dentures is a classic treatment, easily accessible, and presenting satisfactory results. However, to succeed in this type of treatment, stability is an extremely important factor. The neutral zone technique for the production of complete dentures determines the oral cavity space for the positioning of teeth and denture base that provide a neutralization of the forces delivered by lips, cheeks, and tongue, providing better stability and retention of prostheses, which is indicated in cases with history of difficulties in adapting the conventional mandibular denture. Objective and case report: this paper aimed to describe a clinical case report of the oral rehabilitation of a patient with paraprosthetic muscles hypertonicity through removable complete dentures produced by the neutral zone technique, using condensation silicone. Final considerations: the use of condensation silicone for the development of the neutral zone technique showed to be a good alternative for the development of this clinical case, providing satisfactory stability and retention of the complete mandibular denture.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective and Case report: The purpose of this paper is to describe the neutral zone technique in a patient with oral deformity on the right labial commissure due to the resection of an oral cancer, enhancing the difficulty resulting from mouth limited opening and the use of tissue conditioner material to determine the neutral zone. Complete denture was obtained through this technique, providing good retention and stability which made functional rehabilitation feasible to patient of his or her masticatory function. Final considerations: The neutral zone technique in complete dentures will determine a specific intraoral area for tooth position and denture base contour where the forces generated by lips, cheeks and tongue are neutralized. The objective of this technique is to provide an alternative approach for patients who presented an historic instability of lower complete denture: atrophic ridge, oral deformities and also with disorder problems. An oral rehabilitation using this technique improves comfort to the patient providing retention and stability of mandibular complete dentures.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It presented the main features so that the wax plan can be conveniently filling the aesthetic and functional requirement of a denture. The steps of face bow mounting and wax plan transfer form the mouth to the articulator, considering the necessary requirement for this purpose are shown. This sequence aims to instruct and warn those who work with dentures about the needs of using face bows for correct reproduction of the models positioning in the articulator

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este trabalho avaliou comparativamente, em laboratório, a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), um poliéter (Impregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Para isto foi usado como corpo de prova um modelo metálico que simula um maxilar edêntulo, onde foram colocados quatro postes em forma do pirâmide, três truncadas, colocadas na crista do rebordo para medições horizontais, e uma inteira, que servia de referência para uma medição vertical. Com cada material ou técnica foram feitos dez moldes do modelo padrão, que foram vazados com gesso tipo IV. Os sessenta modelos obtidos, bem como o modelo-padrão, foram submetidos às medições das distâncias entre as referências situadas nas pirâmides, três medidas no sentido horizontal e uma no sentido vertical. Isto foi feito numa máquina para medição por coordenadas (tridimensionai), BRT-M507 fabricada pela Mitutoyo, com software Cosmos/Geopak-Win. Os resultados foram submetidos à analise de variância e testes complementares (Post Hoc Tests, de Duncan). A análise dos resultados mostra que quase todas as medidas no plano horizontal foram menores nas réplicas que no padrão, e que na medida vertical a discrepância entre os resultados foi maior, sendo umas medidas maiores e outras menores que no padrão. Estatisticamente, apenas numa das três distâncias avaliadas, Dist. 2, não houve diferença significativa entre os materiais. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present work it was studied the behavior of four water bath curing cycles of heat activated acrylic resin considered as long duration (I – 65ºC for 30 min;50ºC for 23h and 30min; and 100º C for 1h; II- 50ºC for 24h and the rapid cycle), compared to the known long time curing cycle (9 hours for 72ºC) and short curing cycle (1 h for 65ºC; 30 min to elevate at 100º C and 1:00 to 100º C). Analysis consisted of observations and verification of the residual monomer, weight alterations, dimensional, dimensional lineal, porosity and hardness to determine material performance. The results pointed out that residual monomer presented statistical significant differences in the factor storage and interaction among the factors cycle X storage for weight alteration; statistical significant differences for the factor storage for lineal dimensional alterations, without significant differences for hardness. Porosity was verified in minimum degree in the cycle III and in appreciable amount in the cycle IV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary X-ray spectra were measured in the range of 80-150kV in order to validate a computer program based on a semiempirical model. The ratio between the characteristic and total air Kerma was considered to compare computed results and experimental data. Results show that the experimental spectra have higher first HVL and mean energy than the calculated ones. The ratios between the characteristic and total air Kerma for calculated spectra are in good agreement with experimental results for all filtrations used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A stereoselective total synthesis of (-)-cryptocaryol A () is described. Key features of the 17-step route include the use of three boron-mediated aldol reaction-reduction sequences to control all stereocenters and an Ando modification of the Horner-Wadsworth-Emmons olefination that permitted the installation of the Z double bond of the α-pyrone ring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a fast method for the determination of the total sugar levels in samples of raw coffee was developed using the near infrared spectroscopy technique and multivariate regression. The sugar levels were initially obtained using gravimety as the reference method. Later on, the regression models were built from the near infrared spectra of the coffee samples. The original spectra were pre-treated according to the Kubelka-Munk transformation and multiplicative signal correction. The proposed analytical method made possible the direct determination of the total sugar levels in the samples with an error lower by 8% with respect to the conventional methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the dentin shear bond strength of four adhesive systems (Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond) in regards to buccal and lingual surfaces and dentin depth. Forty extracted third molars had roots removed and crowns bisected in the mesiodistal direction. The buccal and lingual surfaces were fixed in a PVC/acrylic resin ring and were divided into buccal and lingual groups assigned to each selected adhesive. The same specimens prepared for the evaluation of superficial dentin shear resistance were used to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0 mm. Each depth was evaluated by ISO TR 11405 using an EMIC-2000 machine regulated at 0.5 mm/min with a 200 Kgf load cell. We performed statistical analyses on the results (ANOVA, Tukey and Scheffé tests). Data revealed statistical differences (p < 0.01) in the adhesive and depth variation as well as adhesive/depth interactions. The Adper Single Bond 2 demonstrated the highest mean values of shear bond strength. The Prompt L-Pop product, a self-etching adhesive, revealed higher mean values compared with Magic Bond DE and Self Etch Bond adhesives, a total and self-etching adhesive respectively. It may be concluded that the shear bond strength of dentin is dependent on material (adhesive system), substrate depth and adhesive/depth interaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: avaliar e mensurar a sutura palatina mediana por meio de radiografias oclusais totais de maxila digitalizadas, antes e depois da sua disjunção. MÉTODOS: a amostra constou de 17 pacientes, com idades entre 7 e 22 anos. Radiografias oclusais totais da maxila foram executadas antes e depois da abertura da sutura palatina mediana, e digitalizadas em scanner HP Scanjet 6110 C com adaptador de transparências HPC 6261 6100 C, utilizando-se o programa Deskscan II. Para a avaliação e medição, foi utilizado o programa Radioimp® (Radiomemory, MG/Brasil). Na análise estatística, foram utilizados a média, o desvio-padrão, o coeficiente de variação e os testes "t" e ANOVA. CONCLUSÕES: após os resultados, foi possível concluir que (1) na região dos incisivos, houve uma abertura palatina mediana estatisticamente significativa; (2) houve abertura de diastema entre os incisivos centrais superiores em torno de 69,37% dos casos; (3) houve uma maior abertura da sutura palatina mediana na região a 10mm a partir da crista para posterior, em comparação com a região a 3mm para posterior do parafuso expansor; (4) na região a 3mm para posterior do parafuso expansor houve uma abertura de 35,97%, e na região a 10mm para posterior da crista uma abertura de 69,37%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to estimate the additional cost of treatment of a group of nosocomial infections in a tertiary public hospital. A retrospective observational cohort study was conducted by means of analyzing the medical records of 34 patients with infection after total knee arthroplasty, diagnosed in 2006 and 2007, who met the criteria for nosocomial infection according to the Centers for Disease Control and Prevention. To estimate the direct costs of treatment for these patients, the following data were gathered: length of hospital stay, laboratory tests, imaging examinations, and surgical procedures performed. Their costs were estimated from the minimum values according to the Brazilian Medical Association. The estimated cost of the antibiotics used was also obtained. The total length of stay in the ward was 976 days, at a cost of US$ 18,994.63, and, in the intensive care unit, it was 34 days at a cost of US$ 5,031.37. Forty-two debridement procedures were performed, at a cost of US$ 5,798.06, and 1965 tests (laboratory and imaging) were also performed, at a cost of US$ 15,359.25. US$ 20,845.01 was spent on antibiotics and US$ 1,735.16 on vacuum assisted closure therapy, microsurgical flaps, implant removal, spacer use, and surgical revision. The total additional cost of these cases of hospital infection in 2006 and 2007 was of US$ 91,843.75. Based on that, we demonstrate that the high cost of treatment for hospital infections emphasizes the importance of taking measures to prevent and control hospital infection.