883 resultados para Proteção radiológica
Resumo:
After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course
Resumo:
O objetivo deste trabalho foi efetuar um estudo de otimização dos parâmetros de exposição do mamógrafo digital da marca GE, modelo Senographe DS instalado no Instituto Português de Oncologia de Coimbra (IPOC) baseado numa análise contraste detalhe e avaliar o impacto do resultado obtido na melhoria da capacidade de detecção clínica das estruturas da mama. O mamógrafo em estudo dispõe de um sistema de controle automático da exposição designado por sistema AOP (Automatic Optimization of Parameters) que foi otimizado pelo fabricante a partir da razão contraste ruído. O sistema AOP é usado na prática clínica na quase totalidade dos exames de mamografia realizados no IPOC. Tendo em conta o tipo de estrutura que se pretende visualizar na mamografia, nomeadamente estruturas de baixo contraste como as massas e estruturas de dimensão submilimétrica como as microcalcificações, a análise contraste detalhe poderia constituir uma abordagem mais adequada para o estudo de otimização dos parâmetros de exposição uma vez que permitiria uma avaliação conjunta do contraste, da resolução espacial e do ruído da imagem. Numa primeira fase do trabalho foi efetuada a caracterização da prática clínica realizada no mamógrafo em estudo em termos de espessura de mama comprimida “típica”, dos parâmetros técnicos de exposição e das opções de processamento das imagens aplicadas pelo sistema AOP (combinação alvo/filtro, tensão aplicada na ampola - kVp e produto corrente-tempo da ampola - mAs). Numa segunda fase foi realizado um estudo de otimização da qualidade da imagem versus dose na perspectiva dos parâmetros físicos. Para tal foi efetuada uma análise contrastedetalhe no objeto simulador de mama CDMAM e usada uma figura de mérito definida a partir do IQFinv (inverted image quality figure) e da dose glandular média. Os resultados apontaram para uma diferença entre o ponto ótimo resultante do estudo de otimização e o ponto associado aos parâmetros de exposição escolhidos pelo sistema AOP, designadamente no caso da mama pequena. Sendo a qualidade da imagem na perspectiva clínica um conceito mais complexo cujo resultado da apreciação de uma imagem de boa qualidade deve ter em conta as diferenças entre observadores, foi efetuado na última parte deste trabalho um estudo do impacto clínico da proposta de otimização da qualidade de imagem. A partir das imagens realizadas com o objeto simulador antropomórfico TOR MAM simulando uma mama pequena, seis médicos(as) radiologistas com mais de 5 anos de experiência em mamografia avaliaram as imagens “otimizadas” obtidas utilizando-se os parâmetros técnicos de exposição resultantes do estudo de otimização e a imagem resultante da escolha do sistema AOP. A análise estatística das avaliações feitas pelos médicos indica que a imagem “otimizada” da mama pequena apresenta uma melhor visualização das microcalcificações sem perda da qualidade da imagem na deteção de fibras e de massas em comparação com a imagem “standard”. Este trabalho permitiu introduzir uma nova definição da figura de mérito para o estudo de otimização da qualidade da imagem versus dose em mamografia. Permitiu também estabelecer uma metodologia consistente que pode facilmente ser aplicada a qualquer outro mamógrafo, contribuindo para a área da otimização em mamografia digital que é uma das áreas mais relevantes no que toca à proteção radiológica do paciente.
Resumo:
Dimensão: 9,5x15,5 cm (fita) / 11x17 cm (caixa)
Resumo:
Os estudos da deglutição por videofluoroscopia (EDVF) são considerados uma avaliação de referência por diversos centros de estudos da deglutição. É um método radiológico que permite observar a dinâmica das estruturas envolvidas na deglutição nas fases preparatória oral, faríngea e esofágica. Este trabalho pretende descrever o contributo do terapeuta da fala (TF) na realização de EDVF em casos de alterações orofaríngeas. Para tal foi efetuada uma revisão de literatura sobre o tema, tendo por base diferentes guidelines publicadas e artigos científicos na área, assim como a experiência clínica adquirida neste domínio no Hospital Privado da Trofa SA. Será enquadrado o papel do TF na realização dos EDVF, descrita a metodologia da avaliação (técnica, materiais e métodos), segurança e proteção radiológica, indicações, limitações e contra indicações desta avaliação instrumental, aspetos fisiológicos e fisiopatológicos analisados. O TF desempenha um papel fundamental na avaliação e intervenção nas alterações orofaríngeas da deglutição. O conhecimento dos procedimentos, metodologias de realização e análise dos resultados da avaliação videofluoroscópica é fulcral para a capacitação e desenvolvimento de competências neste domínio dos Terapeutas da Fala (TFs) assim como para a divulgação do papel do TF na realização dos EDVF.
Resumo:
As evidências indicam que os sistemas de digitalização de imagem deveriam possibilitar uma redução da dose de radiação utilizada na execução de um determinado exame radiológico mas, na prática, nem sempre a dose utilizada é menor que em sistemas convencionais, por um lado, devido às características inerentes dos detectores utilizados e, por outro, ao papel preponderante da intervenção do Técnico de Radiologia. Pretendeu-se comparar a dose à entrada da pele (DEP) em crianças dos 0-5 anos, submetidas a radiografia do tórax, em Incidência Antero-Posterior (AP), em dois hospitais com diferentes sistemas de aquisição de imagem, comparando, também, os valores obtidos, com os níveis de referência de diagnóstico regulamentados pela ICRP. A média da dose à entrada da pele, no hospital que utiliza sistema de digitalização de imagem é de 26,64 Gy, enquanto que no hospital que utiliza sistema convencionail de películas é de 6,85 Gy. Observou-se que a média da dose à entrada da pele, nos sistemas de digitalização de imagem foram superiores à média das doses à entrada da pele nos sistemas convencionais de películas. Em ambos os hospitais a média da dose para as respectivas faixas etárias dos pacientes, não ultrapassou os limites estipulados por lei.
Resumo:
O uso de radiações ionizantes (R.I.), nas mais variadas atividades tem aumentado nas últimas décadas. Com o avanço tecnológico, novos e sofisticados equipamentos emissores de R.I. tem surgido no cenário nacional, o que torna imperativo a difusão do conhecimento sobre os conceitos de proteção radiológica junto à comunidade em geral, e neste sentido, o curso de física médica desenvolve um importante papel, quer seja no aspecto informativo quanto formativo de cidadãos e profissionais críticos e politicamente corretos, que possam contribuir com as Políticas Públicos dos órgãos normatizadores e fiscalizadores das atividades de vigilância sanitária. Conforme a legislação atual (Resolução SS-625 de 14/12/1994, da Secretaria de Estado da Saúde, e Portaria 453 de 01/06/1998 da Vigilância Sanitária do Ministério da Saúde), todos os serviços que utilizam radiações ionizantes devem realizar testes de avaliação dos parâmetros radiométricos dos equipamentos emissores de R.I., sendo exigidos as medidas de Levantamento Radiométrico das instalações, o Teste de Radiação de Fuga do cabeçote emissor e a implementação de Programa de Garantia de Qualidade dos equipamentos e dos procedimentos radiológicos. Este procedimento tem como objetivo principal a obtenção de imagens radiográficas com qualidade e a segurança de pacientes e profissionais, evitando a exposição desnecessária à radiação de pacientes e profissionais. A correta realização de procedimentos radiológicos além de reduzir a dose nos pacientes também promove significativa diminuição nos custos, por não haver necessidade da repetição dos exames. No Brasil, conforme dados da Secretaria de Atenção à Saúde SAS/MS, atualmente existem instalados 4.469 mamógrafos, 25.930 aparelhos de raios-x médicos, 39.438 aparelhos de raios-x odontológicos e...(Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
The Nuclear Medicine is a medical specialty which uses different radioisotopes for diagnostic and therapeutic purposes. The isotopes are radioactive elements which are administered in vivo and present distribution to specific organs or cell types. The knowledge of radioactivity and notions related to ionizing radiation allow to contextualize the radiological protection measures to be taken in Nuclear Medicine. So it is possible to minimize unnecessary exposure to patients, the public, and individuals occupationally exposed and the environmental. For this it is necessary to relate the physical and technological bases apply to this mode with the standards established by regulatory agencies, including the CNEN (National Nuclear Energy Commission) and ANVISA (National Agency for Sanitary Vigilance). In this scenario, it is important that the theoretical endorse the activities which are periodically audited for verification of compliance with the standards that aim to radioprotection. One role of the Medical Physicist in these services is, therefore, act as Radiation Protection Supervisor exerting numerous activities and ensuring compliance with these standards. In this context the stage in the area of Nuclear Medicine was developed in many customers of the enterprise Rad Dimenstein & Associados LTDA, among them the hospitals Israelita Albert Einstein (HIAE), Nossa Senhora de Lourdes (HNSL), Santa Paula (HSP), Cruz Azul (CRAZ), Grupo Fleury, among other clinics. Following the routine and then carrying out various activities pertaining to the Medical Physicist in the area, it was noted that the measures and actions are extremely effective and fundamental in terms of radiological protection
Resumo:
Ionizing radiation is used nowadays in various sectors such as agriculture, industry and medicine. The main specialties of medicine which use radiation are the diagnostic radiology, nuclear medicine and radiotherapy. Radiotherapy is a therapeutic modality that is a well established feature for the treatment of malignant disease or not. However, the inadvertent use of ionizing radiation can produce deleterious effects that result in sequels that compromise the welfare of the people involved. The analysis of radiological protection emphasizes the importance of avoiding inappropriate exhibitions aimed at protecting the health of patients, the professionals involved and the general public. The basic principles of radioprotection are justification, optimization and restriction for individual dosage. The departments of radiotherapy are regulated in accordance with specific technical standards of the National Commission of Nuclear Energy (CNEN), which during the inspection for issue and renewal of the authorization of operation requires the submission of a radioprotection plan, this document that requires great demand of time, and has generated much debate among professionals in medical physics, given the difficulties encountered in their preparation. After examining the radioprotection plan of some radiotherapy services, as suggested in order to guide those responsible for drawing up these plans, especially beginners in the career of the physics of radiation, this paper presents a model plan that is in line radioprotection it requires the Technical Standards of CNEN and can easily be the reality of appropriate services
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology
Resumo:
This work presents a brief historical about the use of ionizing radiations in Veterinary Medicine, instructing the physical beginnings and techniques wrapped in the realization of the proceedings of radiotherapy in animals, illustrating some treated cases, highlighting the difficulties and pointing to the perspectives and importance of the acting of the medical physics in this kind of therapeutic still little used in the national scenery.
Resumo:
O Ipen/Cnen-SP possui um Reator de Pesquisa(IEA-R1) em operação desde 1957. Ele utiliza água leve como blindagem, moderador e como fluido refrigerante, o volume desta piscina é de 273m3. Até 1995 a operação do Reator era descontinua, ou seja, operava diariamente sendo desligado no final do dia, a uma potência de 2,0 MW. A partir daquele ano, após algumas modificações de segurança, o Reator passou a operar de forma continua, ou seja, de segunda-feira a quarta-feira sem ser desligado, totalizando 64 horas semanais. A potência também foi aumentando até 4,5 MW em 2012. Em virtude dessas alterações, a saber, operação contínua e do aumento da potência, as doses dos trabalhadores aumentaram e por isso foram realizados vários estudos para diminui-las. Estudos demonstraram que uma das principais limitações para operação de um reator em potência elevada, provém das radiações gama emitidas pelo sódio-24. Outros elementos como magnésio-27, Alumínio-28, Argônio-51, contribuem de forma considerável para a atividade da água da piscina. A introdução de uma camada de água quente em sua superfície, estável e isenta de elementos radioativos com 1,5m a 2m de espessura constituiria uma blindagem às radiações provenientes dos elementos radioativos dissolvidos na água. Estudos de otimização provaram que a instalação da camada quente não era necessária para o regime e potência atual de operação do Reator, pois outros procedimentos adotados eram mais eficazes. A partir desta decisão o serviço de Proteção Radiológica do Reator IEA-R1, montou um programa de avaliação das doses para certificar-se de que elas se mantinham em valores razoáveis baseados em princípios estabelecidos em normas nacionais e internacionais. O intuito deste trabalho é realizar uma análise das doses individuais dos IOE (Individuo Ocupacionalmente Expostos), considerando as mudanças no regime de operação do Reator e sugerir opções de proteção e segurança, viáveis em primeira instância, para reduzir as doses analisadas, visando se chegar aos níveis de referencia de 3 mSv/ano adotados pela instalação em apreço.
Resumo:
A radioatividade natural presente em solos, rochas e materiais de construção, devida ao 40K e às séries radioativas do 232Th e 238U é a principal contribuição à exposição externa aos seres humanos. Neste trabalho, determinou-se as concentrações de atividade de 226Ra (da série do 238U), 232Th e 40K presentes em 50 amostras de tintas látex de cor branca comercializadas no Brasil, especificamente, 15 do tipo econômico, 15 do tipo standard, 20 do tipo premium e em uma amostra de dióxido de titânio. As amostras foram seladas e armazenadas por um período mínimo de 30 dias para se alcançar o equilíbrio radioativo secular nas séries do 238U e do 232Th e medidas pela técnica analítica de espectrometria gama de alta resolução. As concentrações de atividade foram calculadas utilizando-se as médias ponderadas pelas incertezas do 214Pb e 214Bi para o 226Ra e médias ponderadas pelas incertezas do 228Ac, 212Pb e 212Bi para o 232Th. A concentração de atividade do 40K foi determinada pela sua transição única de 1460,8 keV. Fatores de autoatenuação gama foram calculados e utilizados para correção da concentração de atividade das amostras com densidade maior que 1,0 g.cm-3. Os índices radiológicos equivalente em rádio (Raeq), índice de concentração de atividade (Iγ), índice de risco à exposição gama interna (Hin), o índice de risco à exposição gama externa (Hex) e a taxa de dose (D) e dose efetiva anual (Def) foram calculados a partir das concentrações de atividade do 226Ra, 232Th e 40K. As concentrações de atividade de 226Ra das tintas variaram entre valores abaixo da atividade mínima detectável e 38,7 Bq.kg-1, as de 232Th variaram entre valores abaixo da atividade mínima detectável e 101,2 Bq.kg-1 e as de 40K variaram entre valores abaixo da atividade mínima detectável e 256 Bq.kg-1. O Raeq variou entre 1,41 Bq.kg-1 e 203 Bq.kg-1, o Iγ variou entre 0,0047 e 0,720, o Hin variou entre 0,0076 e 0,653 e o Hex variou entre 0,0038 e 0,549. A taxa de dose variou de 0,170 nGy.h-1 a 21,3 nGy.h-1 e a dose efetiva anual variou entre 0,83 μSv.a-1 e 104,2 μSv.a-1. Estes resultados mostram que as concentrações de atividades das tintas utilizadas neste estudo estão abaixo dos limites recomendados por Hassan et al. para Raeq (370 Bq.kg-1), pela Comissão Européia para o Iγ (limite de 2 para materiais superficiais) e pela Organização para Cooperação Econômica e Desenvolvimento para Hin e para Hex (ambos com limite de 1), para todas as 50 amostras estudadas, mostrando assim a segurança destas tintas com relação a proteção radiológica.
Resumo:
O sistema microPET/CT é um importante equipamento utilizado nas pesquisas de imagem diagnóstica em pequenos animais. O radiofármaco mais usado nesta tecnologia é o fluordeoxiglicose marcado com flúor-18. Este estudo tem como objetivo efetuar o controle radiológico no laboratório de pesquisa microPET/CT do Centro de Radiofarmácia do IPEN-CNEN/SP, de forma a satisfazer tanto as normas nacionais como as recomendações internacionais. O laboratório está classificado pela equipe de radioproteção da instalação como área supervisionada, nas quais embora não seja obrigatória a adoção de medidas específicas de proteção e segurança, devem ser submetidas reavaliações regulares das condições do ambiente de trabalho. Visando assegurar a proteção radiológica dos trabalhadores diretamente envolvidos no manuseio do equipamento, realizou-se o monitoramento do local de trabalho e a avaliação do controle de dose individual. Inicialmente foi feito o monitoramento pré-operacional, isto é, o levantamento radiométrico no laboratório. Além disso, mediu-se nível de radiação externa nas instalações do laboratório e suas adjacências, por meio da colocação de nove dosímetros termoluminescentes (TL) de CaSO4:Dy, em locais previamente selecionados. Os indivíduos ocupacionalmente expostos foram avaliados mensalmente por meio do uso de dosímetros TL posicionados no tórax e por medidas de corpo inteiro, tomadas a cada seis meses. O período do estudo foi de dois anos, com início em abril de 2014. Para o controle do microPET/CT realizou-se testes de desempenho de acordo com o protocolo padrão do equipamento e em conformidade com a norma desenvolvida pela força tarefa para estudos com PET em animais Animal PET Standard Task Force. O presente estudo permitiu demonstrar que os níveis de radiação das áreas (estimativas de dose ambiente e dose efetiva), assim como a blindagem do equipamento estão adequados de acordo com os limites da exposição ocupacional. Ressalta-se a importância de se seguir rigorosamente os princípios de radioproteção, já que se trata de pesquisas com fontes radioativas não seladas.