798 resultados para Prosthesis protocol
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Implant-supported prosthesis following Branemark protocol on electromyography of masticatory muscles
Resumo:
This research evaluated the effects of Branemark protocol on electromyography of the masseter and temporal muscles. The patients were divided into two groups: Group 1: patients who wore an implant-supported prosthesis in the mandibular arch following Branemark protocol, and maxillary removable complete dentures; Group II: dentate individuals (control). Electromyography was carried out at rest, right (RL) and left (LL) laterality, protrusion and maximum voluntary contraction (MVC). Data were compared by t-test. At rest, a higher electromyographic (EMG) activity was observed in Group I, and the values were significant in the right masseter and left temporal muscles. In RL, there were statistically significant differences for right masseter (P < 0.01), left masseter and temporal muscles and for the left temporal muscle in LL (P < 0.05). In protrusion, Group I presented a higher EMG activity, and there was a statistically significant difference for the right masseter muscle (RM) (P < 0.05). In MVC, the EMG values were higher in Group II (control), but significant just for the right temporal muscle (P < 0.05). In conclusion, individuals with mandibular fixed dentures supported according to the Branemark protocol and maxillary removable complete dentures showed a higher activity of masticatory muscles during the mandibular postural clinical conditions examined; however, in the MVC, Group I presented lower values when compared to dentate group. Despite presenting different EMG values in all of the clinical conditions, both groups showed similar EMG patterns of muscle activation which demonstrates that the proposed treatment can be considered as a good option for oral rehabilitation.
Resumo:
Currently, there are several techniques for the rehabilitation of atrophic maxillary ridges in literature. The grafting procedure using autogenous bone is considered ideal by many researchers, as it shows osteogenic capability and causes no antigenic reaction. However, this type of bone graft has some shortcomings, mainly the restricted availability of donor sites. In recent years, several alternatives have been investigated to supply the disadvantages of autogenous bone grafts. In such studies, allogeneic bone grafts, which are obtained from individuals with different genetic load, but from the same species, have been extensively used. They can be indicated in cases of arthroplasty, surgical knee reconstruction, large bone defects, and in oral and maxillofacial reconstruction. Besides showing great applicability and biocompatibility, this type of bone is available in unlimited quantities. on the other hand, allogeneic bone may have the disadvantage of transmitting infectious diseases. Atrophic maxillae can be treated with bone grafts followed by osseointegrated implants to obtain aesthetic and functional oral rehabilitation. This study aimed to show the viability of allogeneic bone grafting in an atrophic maxilla, followed by oral rehabilitation with dental implant and protocol-type prosthesis within a 3-year follow-up period by means of a clinical case report.
Resumo:
The aim of this article is to describe a successful clinical protocol for prosthodontic rehabilitation of a patient with a skeletal Class III malocclusion using a fixed-detachable maxillary prosthesis supported by 6 implants and the MK1 attachment system. The patient was followed up for 8 years. A 46-year-old edentulous woman with a skeletal Class III malocclusion expressed dissatisfaction with her old existing maxillary denture from an esthetic point of view and frustration regarding its function. A fixed-detachable maxillary prosthesis using the MK1 attachment system was made. The patient was followed up clinically and radiographically for 8 years. No bone loss, fracture of prosthetic components, or fracture of the prosthesis was detected in that period. A fixed detachable maxillary prosthesis using the MK1 attachment system is a treatment option for patients with Class III malocclusions who opt not to undergo orthognathic surgery.
Resumo:
A proper cast is essential for a successful rehabilitation with implant prostheses, in order to produce better structures and induce less strain on the implants. The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. A total of 40 casts were obtained from a metallic matrix simulating three unit implant-retained prostheses. The molds were filled using four different techniques in four groups (n = 10): Group 1 - Single-portion filling technique; Group 2 - Two-step filling technique; Group 3 - Latex cylinder technique; Group 4 - Joining the implant analogs previously to the mold filling. A titanium framework was obtained and used as a reference to evaluate the marginal misfit and tension forces in each cast. Vertical misfit was measured with an optical microscope with an increase of 120 times following the single-screw test protocol. Strain was quantified using strain gauges. Data were analyzed using one-way ANOVA (Tukey's test) (α =0.05). The correlation between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistical difference (P = 0.979), while the strain results showed statistical difference between Groups 3 and 4 (P = 0.027). The splinting technique was considered to be as efficient as the conventional technique. The strain gauge methodology was accurate for strain measurements and cast distortion evaluation. There was no correlation between strain and marginal misfit.
Resumo:
Objectives: The aim of this study was to determine the precision of the measurements of 2 craniometric anatomic points-glabella and anterior nasal spine-in order to verify their possibility as potential locations for placing implants aimed at nasal prostheses retention. Methods: Twenty-six dry human skulls were scanned in a high-resolution spiral tomography with 1-mm axial slice thickness and 1-mm interval reconstruction using a bone tissue filter. Images obtained were stored and transferred to an independent workstation containing e-film imaging software. The measurements (in the glabella and anterior nasal fossa) were made independently by 2 observers twice for each measurement. Data were submitted to statistical analysis (parametric t test). Results: The results demonstrated no statistically significant difference between interobserver and intraobserver measurements (P > .05). The standard error was found to be between 0.49 mm and 0.84 mrn for measurements in bone protocol, indicating a high /eve/ of precision. Conclusions: The measurements obtained in anterior nasal spine and glabella were considered precise and reproducible. Mean values of such measurements pointed to the possibility of implant placement in these regions, particularly in the anterior nasal spine.
Resumo:
A 41-year-old man with cleft palate presented with a wide dehiscence and missing teeth. Six implants had been placed for fabrication of an overdenture, which was unsatisfactory. A bar was waxed and cast for connection to the implants; precision attachments were placed laterally for retention. A fixed partial denture was fabricated, and milled crowns were fabricated at the molar region to provide a guiding plane for insertion of a removable palatal obturator. Good swallowing and speech outcomes were achieved. This technique provided functional and esthetic benefits, enhanced oral hygiene, and improved the psychological condition of the patient.
Resumo:
Mestrado em Gestão e Avaliação de Tecnologias em Saúde
Resumo:
Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.
Resumo:
To date, transapical aortic valve implantation has required a balloon-expandable stented valve prosthesis. More recently, a novel self-expanding sutureless stented bovine pericardial prosthesis has been developed which allows rapid aortic valve replacement via an open transaortic approach in humans. The aim of this animal study was to develop a reliable protocol to facilitate the transapical implantation of this self-expanding valve in a porcine model.
Resumo:
BACKGROUND Periprosthetic infections remain a devastating problem in the field of joint arthroplasty. In the following study, the results of a two-stage treatment protocol for chronic periprosthetic infections using an intraoperatively molded cement prosthesis-like spacer (CPLS) are presented. METHODS Seventy-five patients with chronically infected knee prosthesis received a two-stage revision procedure with the newly developed CPLS between June 2006 and June 2011. Based on the microorganism involved, patients were grouped into either easy to treat (ETT) or difficult to treat (DTT) and treated accordingly. Range of motion (ROM) and the knee society score (KSS) were utilized for functional assessment. RESULTS Mean duration of the CPLS implant in the DTT group was 3.6 months (range 3-5 months) and in the ETT group 1.3 months (range 0.7-2.5 months). Reinfection rates of the final prosthesis were 9.6% in the ETT and 8.3% in the DTT group with no significant difference between both groups regarding ROM or KSS (P = 0.87, 0.64, resp.). CONCLUSION The results show that ETT patients do not necessitate the same treatment protocol as DTT patients to achieve the same goal, emphasizing the need to differentiate between therapeutic regimes. We also highlight the feasibility of CLPS in two-stage protocols.
Resumo:
Protocols for the generation of dendritic cells (DCs) using serum as a supplementation of culture media leads to reactions due to animal proteins and disease transmissions. Several types of serum-free media (SFM), based on good manufacture practices (GMP), have recently been used and seem to be a viable option. The aim of this study was to evaluate the results of the differentiation, maturation, and function of DCs from Acute Myeloid Leukemia patients (AML), generated in SFM and medium supplemented with autologous serum (AS). DCs were analyzed by phenotype characteristics, viability, and functionality. The results showed the possibility of generating viable DCs in all the conditions tested. In patients, the X-VIVO 15 medium was more efficient than the other media tested in the generation of DCs producing IL-12p70 (p=0.05). Moreover, the presence of AS led to a significant increase of IL-10 by DCs as compared with CellGro (p=0.05) and X-Vivo15 (p=0.05) media, both in patients and donors. We concluded that SFM was efficient in the production of DCs for immunotherapy in AML patients. However, the use of AS appears to interfere with the functional capacity of the generated DCs.
Resumo:
The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.
Resumo:
Introdution: The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients.